My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
505 E Central Ave #B - DEF 1 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Central Ave
>
505 E Central Ave Unit# B
>
505 E Central Ave #B - DEF 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:01:47 AM
Creation date
2/24/2026 5:00:42 AM
Metadata
Fields
Template:
Plan
Permit Number
20181754
30146722
40138703
101117766
101124090
Full Address
505 E Central Ave Unit# B
Street Number
505
Street Direction
E
Street Name
Central
Street Suffix
Ave
Unit Number
B
Document Relationships
101117766 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
101124090 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
20181754 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
30146722 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
40138703 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
994
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CITY OF SANTA ANA <br />SPECIFICATIONS <br />PROJECT NO.: XX-XXXX <br />PROJECT TITLE <br /> <br />96 <br />substrate up to and coincident with the cut edge of the sign panel shall be <br />sufficient basis for rejection of the entire sign panel. <br />All treatment tanks and/or spray-applied systems must be performed on the <br />contractor premises, to ensure proper adhesion of reflective sheeting materials. <br />All treatment tanks or spray-applied systems shall be charged with fresh <br />chemicals at least once a year. If pretreatment is performed by immersion <br />methods, the tanks must be sufficient size to accommodate the complete panel. <br />Titration equipment shall be available for the inspectors to check the solutions <br />strengths. The cleaned and coated base metal shall be handled only by a <br />mechanical device or by operators wearing clean cotton or rubber gloves. After <br />cleaning and coating operations, the panels shall be protected at all times from <br />contact or exposure to grease, oils, dust or other contaminates. <br />The front and back surfaces of the aluminum base metal shall be cleaned, <br />deoxidized, and coated with a light tightly adherent chromate conversion coating <br />free of any powdery residue. The base metal pretreatment process shall be in <br />conformance with Section 5, “Recommended Processing methods” of ASTM <br />Designation B-449. The coating weight shall be 30-100 mg/sq.ft. (285-950 <br />mg/sq.m.), A class 1 coating. <br />2. Sign Message and Reflectorized Material: <br />Sign panels with identical legends shall be displayed on both sides of the sign <br />frame unless otherwise indicated. <br />Letter size, style, spacing, arrows, and figures shall conform to the current <br />standards established by Caltrans. <br />a. The legends or street name shall be 8” (200 mm) upper case and 6” (150 mm) <br />lower case. Series D shall be used. <br />b. Street suffixes and block number will be 4” (100 mm). Series D shall be used. <br />c. 1” (27 mm) border. <br />d. Message layout shall be per attached drawing. Side margins and spacing may <br />be compressed when necessary to stay within sign length. <br />3M Diamond Grade DG3 Series 4000 or equivalent shall be used on both fore and <br />background. The standard color shall be white legends, letters, borders, etc., <br />on a screened green background. No cut out legends, letters or border shall be <br />used. <br />3. Sign Frame & Panel Construction: <br />The width or the sign shall be 18” (450 mm). Length to be determined by the text <br />and shall not be less than 48” (1200 mm) or more than 96” (2400 mm). <br />505 E Central Ave <br />#B11/6/2024
The URL can be used to link to this page
Your browser does not support the video tag.