CITY OF SANTA ANA <br />SPECIFICATIONS <br />PROJECT NO.: XX-XXXX <br />PROJECT TITLE <br /> <br />96 <br />substrate up to and coincident with the cut edge of the sign panel shall be <br />sufficient basis for rejection of the entire sign panel. <br />All treatment tanks and/or spray-applied systems must be performed on the <br />contractor premises, to ensure proper adhesion of reflective sheeting materials. <br />All treatment tanks or spray-applied systems shall be charged with fresh <br />chemicals at least once a year. If pretreatment is performed by immersion <br />methods, the tanks must be sufficient size to accommodate the complete panel. <br />Titration equipment shall be available for the inspectors to check the solutions <br />strengths. The cleaned and coated base metal shall be handled only by a <br />mechanical device or by operators wearing clean cotton or rubber gloves. After <br />cleaning and coating operations, the panels shall be protected at all times from <br />contact or exposure to grease, oils, dust or other contaminates. <br />The front and back surfaces of the aluminum base metal shall be cleaned, <br />deoxidized, and coated with a light tightly adherent chromate conversion coating <br />free of any powdery residue. The base metal pretreatment process shall be in <br />conformance with Section 5, “Recommended Processing methods” of ASTM <br />Designation B-449. The coating weight shall be 30-100 mg/sq.ft. (285-950 <br />mg/sq.m.), A class 1 coating. <br />2. Sign Message and Reflectorized Material: <br />Sign panels with identical legends shall be displayed on both sides of the sign <br />frame unless otherwise indicated. <br />Letter size, style, spacing, arrows, and figures shall conform to the current <br />standards established by Caltrans. <br />a. The legends or street name shall be 8” (200 mm) upper case and 6” (150 mm) <br />lower case. Series D shall be used. <br />b. Street suffixes and block number will be 4” (100 mm). Series D shall be used. <br />c. 1” (27 mm) border. <br />d. Message layout shall be per attached drawing. Side margins and spacing may <br />be compressed when necessary to stay within sign length. <br />3M Diamond Grade DG3 Series 4000 or equivalent shall be used on both fore and <br />background. The standard color shall be white legends, letters, borders, etc., <br />on a screened green background. No cut out legends, letters or border shall be <br />used. <br />3. Sign Frame & Panel Construction: <br />The width or the sign shall be 18” (450 mm). Length to be determined by the text <br />and shall not be less than 48” (1200 mm) or more than 96” (2400 mm). <br />505 E Central Ave <br />#B11/6/2024