Laserfiche WebLink
CITY OF SANTA ANA <br />SPECIFICATIONS <br />PROJECT NO.: XX-XXXX <br />PROJECT TITLE <br /> <br />103 <br />installation, (3) after installation but prior to connection to any other portion <br />of the system, and (4) during final system testing. All active components shall <br />be tested after installation. The Contractor shall provide all personnel, <br />equipment, instrumentation and materials necessary to perform all testing. <br />The Engineer shall be notified in writing a minimum of two working days <br />prior to all field tests. The notification shall include the exact location or <br />portion of the system to be tested. <br />Documentation of all test results shall be provided to the Engineer for <br />approval within two working days after the test involved. The Contractors <br />attention is directed to "As-Builts" elsewhere in these special provisions, <br />regarding the requirements for recording test results. <br />Attenuation tests shall be performed with an OTDR capable of recording and <br />displaying anomalies of 0.2 dB as a minimum. Single mode fibers (SM) shall <br />be tested at 1310 nm and 1550 nm. <br />The OTDR shall have a printer capable of producing a verifying test trace <br />with fiber identification as shown in the sample "Link Loss Budget Work <br />Sheet", numerical loss values, the date and the operator's name. It shall also <br />have a DOS based 3.5 inch-disk recording capability that has associated <br />software to do comparisons and reproductions on 8.5 inch x 11 inch paper, via <br />a personal computer. <br />Prior to arrival of the cable, the Contractor shall provide detailed test procedures <br />for all field testing to the Engineer. The procedures shall include the tests <br />involved and how the tests are to be conducted. These test plans shall be subject <br />to the approval of the Engineer. The procedures shall include the tests involved <br />and how the tests are to be conducted. Included in the test procedures shall be <br />the model, manufacturer, configuration, calibration and alignment procedures for <br />all proposed test equipment. <br />b. Factory Testing <br />Verification of the fiber specifications as listed in the Fiber Characteristics <br />Table shall be supplied by the Manufacturer with the appropriate <br />documentation. After cabling, before shipment but while on the shipping reel, <br />100 percent of all fibers shall be tested for attenuation. Copies of the res ults <br />shall be (1) maintained on file at the Contractor's, Manufacturer's and Owner's <br />place of business with a file identification number for a minimum of 10 years, <br />(2) attached to the cable reel in a waterproof pouch, and (3) submitted to the <br />Contractor and to the Engineer prior to the delivery of the cable to the job site. <br />c. Arrival On Site <br />The cable and reel shall be physically inspected by the Contractor on delivery <br />and 100 percent of the fibers shall be tested with the OTDR for attenuation to <br />505 E Central Ave <br />#B11/6/2024