My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
505 E Central Ave #B - DEF 1 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Central Ave
>
505 E Central Ave Unit# B
>
505 E Central Ave #B - DEF 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:01:47 AM
Creation date
2/24/2026 5:00:42 AM
Metadata
Fields
Template:
Plan
Permit Number
20181754
30146722
40138703
101117766
101124090
Full Address
505 E Central Ave Unit# B
Street Number
505
Street Direction
E
Street Name
Central
Street Suffix
Ave
Unit Number
B
Document Relationships
101117766 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
101124090 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
20181754 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
30146722 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
40138703 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
994
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CITY OF SANTA ANA <br />SPECIFICATIONS <br />PROJECT NO.: XX-XXXX <br />PROJECT TITLE <br /> <br />149 <br />bypass piping for the effluent during the construction of the sewer main between <br />manholes. The inlet of the downstream manhole and the outlet of the upstream manhole <br />shall be plugged. A portable pump shall be installed in the upstream manhole to <br />discharge the effluent from the upstream manhole to the downstream manhole through <br />the bypass piping. Pump and bypass piping shall be of adequate size and capacity to <br />handle the flow without sewage backup occurring to facilities connected to the sewer. <br />For sewers 12-inches in diameter and larger, or where deemed necessary by the City, the <br />following shall apply: <br />All pumps used shall be fully automatic self-priming units. All pumps used must be <br />constructed to allow dry running for long periods of time to accommodate the cyclical <br />nature of effluent flows. The Contractor shall provide the necessary stop/start controls <br />for each pump. The Contractor shall have adequate standby equipment available and <br />ready for immediate operation and use in the event of an emergency or breakdown. One <br />standby pump for each size pump utilized shall be installed at the mainline flow <br />bypassing locations, ready for use in the event of primary pump failure. The Contractor <br />shall continually monitor all pumping equipment. The Contractor shall perform leakage <br />and pressure tests of the bypass pumping discharge piping suing clean water prior to the <br />actual operation. The Water Resources Division shall be given 24 hours notice prior to <br />testing. <br />The Contractor shall be required to flow monitor for a two week period to assist in sizing <br />the pumps necessary for the sewer work and shall be considered included as part of the <br />work. The Contractor shall prepare, with the vendor, a flow monitoring map for key <br />manholes that will provide adequate data for the work subject to review and approval <br />from the Water Resources Division. Flow monitoring shall capture accurate <br />instantaneous depth, velocity and flow data in 15-minute increments or less, or as <br />otherwise approved by the Water Resources Division. The Contractor shall prepare with <br />the vendor a specific, detailed description of the proposed pumping system and submit it <br />and the vendor’s references to the City. The Contractor shall submit to the City detailed <br />descriptions outlining all provisions and precautions to be taken by the Contractor <br />regarding handling of existing sewage flows. The submit tal must be specific and <br />complete, including such items as schedules, capacities of equipment, materials, and all <br />other incidental protection of the access and bypass pumping locations from damage due <br />to the discharge flows. <br />The submittal shall include but not be limited to the following: <br />1. Sewer plugging method and types of plug. <br />2. Number, size, material, location and method of installation of suction piping. <br />3. Number, size, material, location and method of installation of discharge piping. <br />4. Bypass pump sizes, capacity, number of each size to be on-site and power <br />requirements. <br />505 E Central Ave <br />#B11/6/2024
The URL can be used to link to this page
Your browser does not support the video tag.