My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
505 E Central Ave #B - DEF 1 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Central Ave
>
505 E Central Ave Unit# B
>
505 E Central Ave #B - DEF 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:01:47 AM
Creation date
2/24/2026 5:00:42 AM
Metadata
Fields
Template:
Plan
Permit Number
20181754
30146722
40138703
101117766
101124090
Full Address
505 E Central Ave Unit# B
Street Number
505
Street Direction
E
Street Name
Central
Street Suffix
Ave
Unit Number
B
Document Relationships
101117766 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
101124090 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
20181754 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
30146722 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
40138703 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
994
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CITY OF SANTA ANA <br />SPECIFICATIONS <br />PROJECT NO.: XX-XXXX <br />PROJECT TITLE <br /> <br />182 <br />rubber, conical shape, pull on or wrap-around style with type 316 stainless steel <br />bands. <br />G. PREPARATION <br />Confirm location of all known existing utilities prior to start of jacking/receiving pit <br />excavation and pipe installation. The Contractor shall provide the detailed layout <br />required to keep the bore on grade. Notify the Engineer no less than (10) working <br />days before beginning shaft excavation. Before beginning construction of <br />jacking/receiving pit, adequately protect existing structures, utilities, trees, shrubs, <br />and other existing facilities. Place fencing, gates, lights, and signs, as necessary <br />around shafts and staging areas to provide for public safety. When preparing to <br />install casing pipe, verify casing pipe minimum wall thickness is adequate for <br />anticipated jacking loads. <br />H. INSTALLATION <br />Jacking and receiving pit construction shall be such as to ensure the safety of the <br />work, contractor’s employees, the public, existing utilities, and adjacent property and <br />improvements, whether public or private and shall comply with the State of <br />California requirements and Section 306 of the Standard Specifications and these <br />Special Provisions. Provide complete groundwater control for excavations at all <br />times. Perform jacking and receiving pit excavations using appropriate excavation or <br />large hole drilling methods, as required. Inspect shaft and pit excavations daily to <br />check the safety of excavation and structural integrity of support system. Open <br />excavations shall conform to all federal, state, and local requirements. Once initiated <br />jacking operations shall continue without interruption, to prevent the pipe from <br />becoming firmly set in the embankment. <br />I. LUBRICATION OF EXTERIOR OF PIPE AND/OR CASING <br />Bentonite slurry may be used to lubricate exterior of pipe and/or casing during <br />installation. Use of water to facilitate removal of spoil is permitted; however, water <br />jetting is not allowed. <br />J. JACKED AND BORED STEEL CASING <br />Bore hole diameter shall not exceed outside diameter of casing by more than one (1) <br />inch. When unstable soil conditions are found to exist, conduct boring operations in a <br />manner that will not be detrimental to facility being crossed. Horizontal line <br />tolerance is two (2) inches, maximum. Vertical line tolerance is two (2) inches, <br />maximum. A means of steering the pipe or casing must be provided to ensure <br />allowable tolerances will not be exceeded. The Contractor must measure and record <br />progress at all times to confirm that horizontal and vertical lines are within allowable <br />tolerances. <br />For casing: Weld sections of casing pipe together to provide water tight joints by <br />operators qualified in accordance with the American Welding Society Standard <br />505 E Central Ave <br />#B11/6/2024
The URL can be used to link to this page
Your browser does not support the video tag.