My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
505 E Central Ave #B - DEF 1 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Central Ave
>
505 E Central Ave Unit# B
>
505 E Central Ave #B - DEF 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:01:47 AM
Creation date
2/24/2026 5:00:42 AM
Metadata
Fields
Template:
Plan
Permit Number
20181754
30146722
40138703
101117766
101124090
Full Address
505 E Central Ave Unit# B
Street Number
505
Street Direction
E
Street Name
Central
Street Suffix
Ave
Unit Number
B
Document Relationships
101117766 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
101124090 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
20181754 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
30146722 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
40138703 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
994
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CITY OF SANTA ANA <br />SPECIFICATIONS <br />PROJECT NO.: XX-XXXX <br />PROJECT TITLE <br /> <br />185 <br />The grounding anode wire shall be connected to the identified terminal on all access <br />boxes <br />B. CONNECTORS <br />Direct bury wire connectors shall be specifically manufactured for underground trace <br />wire installation. Connectors shall be dielectric and filled with silicon to seal out <br />moisture and corrosion. <br />All splices of the wire shall be made securely and covered thoroughly with a Direct <br />Bury Splice Kit, 3M DBY/DBR or approved equal. <br />All mainline trace wires must be interconnected at intersections and at fire hydrant <br />tees. At tees, the connections and splices shall be accomplished using a direct burial <br />connectors and splice kits with single 3-way lockable connector and or 4-way <br />lockable connector. <br />Non-locking friction fit, taped and twist on connectors are not allowed. <br />C. GROUNDING <br />At all dead-ends, trace wire shall go to ground using an approved connection to a <br />drive- in magnesium grounding anode rod with a minimum of 20ft of #14 red HDPE <br />insulated copper clad steel wire connected to the anode. In o ccurrences where trace <br />wire is encountered on an existing utility that is being extended or tied into, the new <br />trace wire and the existing wire shall be connected using approved splice connectors. <br />When grounding the trace wire, the grounding anode shall be installed in a direction <br />180 degrees opposite to the trace wire. Do not coil excess wire from grounding anode. <br />The grounding anode wire shall be trimmed to an appropriate length before <br />connecting to the trace wire with a mainline to lateral connector. <br />D. TESTING <br />The Contractor shall schedule and conduct a conductivity test on completion of the <br />water main installation and prior to placement final pavement. <br />All trace wire installations shall be located using low frequency line tracing <br />equipment. If the conductivity test fails, the Contractor shall be responsible for <br />making the necessary repairs, including but not limited to excavation, repair and re - <br />test passing results are achieved and satisfactory to the Engineer. <br />Continuity test in lieu of actual line testing will not be accepted. <br />505 E Central Ave <br />#B11/6/2024
The URL can be used to link to this page
Your browser does not support the video tag.