My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
505 E Central Ave #B - DEF 1 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Central Ave
>
505 E Central Ave Unit# B
>
505 E Central Ave #B - DEF 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:01:47 AM
Creation date
2/24/2026 5:00:42 AM
Metadata
Fields
Template:
Plan
Permit Number
20181754
30146722
40138703
101117766
101124090
Full Address
505 E Central Ave Unit# B
Street Number
505
Street Direction
E
Street Name
Central
Street Suffix
Ave
Unit Number
B
Document Relationships
101117766 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
101124090 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
20181754 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
30146722 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
40138703 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
994
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
TEEN AREA <br />4 <br />GENERAL <br />STACKS <br />3 <br />275 SF <br />OFFICE <br />1 AC-1 <br />12"x8" <br />A -12"Ø <br />400 CFM <br />A -8"Ø <br />135 CFM <br />A -8"Ø <br />135 CFM <br />A -8"Ø <br />140 CFM <br />A -8"Ø <br />140 CFM <br />A -8"Ø <br />140 CFMA -8"Ø <br />140 CFM <br />8"ø <br />10"ø <br />8"ø <br />12"ø12"ø20"ø 20"ø <br />12"ø <br />8"ø <br />8"ø <br />A -8"Ø <br />140 CFM <br />A -8"Ø <br />140 CFM <br />10"ø <br />8"ø <br />8"ø <br />16"ø <br />8"ø 8"ø <br />14"ø <br />14"ø <br />8"ø 8"ø <br />14"ø <br />8"ø A -8"Ø <br />150 CFM <br />10"ø <br />8"ø 8"ø <br />A -8"Ø <br />150 CFM <br />A -8"Ø <br />150 CFM <br />A -8"Ø <br />150 CFM <br />A -8"Ø <br />150 CFM <br />12"x8" <br />(R) 18"x8" <br />(E) 8"ø <br />(E) 8"x6" <br />(E) 8"x6" <br />(E) 8"x6" <br />14 <br />" <br />x <br />8 <br />" <br />1 <br />4 <br />" <br />x <br />8 <br />" <br />B -26"x10" <br />705 CFM <br />B -14"x10" <br />710 CFM <br />12"ø <br />12"ø <br />B -14"x10" <br />330 CFM <br />(E) B - 24"x24" <br />330 CFM <br />(E) A - 8"Ø <br />135 CFM <br />(E) A - 8"Ø <br />130 CFM <br />(E) A - 8"Ø <br />135 CFM <br />(E) B - 24"x24" <br />640 CFM <br />(E) 12"ø <br />(E) 12"ø <br />EF-1 <br />6"ø <br />2 <br />1 <br />(R) 18"x8" <br />3 <br />3 <br />3 <br />4 <br />5 <br />6 <br />AC-1 <br />7 <br />(E) AC-13 <br />8 <br />(E) AC-148 <br />(E) 8"x6" <br />8"x6" <br />RESTROOM <br />2 <br />CHILDRENS AREA <br />5 <br />EXISTING <br />HALLWAY <br />6 <br />12"ø <br />12"ø <br />(E) 12"ø <br />A -8"Ø <br />140 CFM <br />9 <br />10 <br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS <br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF <br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY <br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR <br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA <br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018. <br />SCALE: <br />REVISIONS: <br />OW <br />N <br />E <br />R <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />CL <br />I <br />E <br />N <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707 <br />T 949.809.3380 WWW.SVA-ARCHITECTS.COM <br />DATE ISSUED: <br />PROJECT NO: <br />Consulting Engineer <br />www.alphamep.net <br />1/4" = 1'-0" <br />Issue Date <br />M101 <br />FLOOR PLAN - <br />MECHANICAL <br />23-020-01 <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />DE <br />L <br />H <br />I <br /> <br />C <br />O <br />M <br />M <br />U <br />N <br />I <br />T <br />Y <br /> <br />C <br />E <br />N <br />T <br />E <br />R <br />RE <br />N <br />O <br />V <br />A <br />T <br />I <br />O <br />N <br />50 <br />5 <br /> <br />E <br /> <br />C <br />e <br />n <br />t <br />r <br />a <br />l <br /> <br />A <br />v <br />e <br />, <br /> <br />U <br />n <br />i <br />t <br /> <br />B <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />Scale: <br />1/4" = 1'-0"1FLOOR PLAN - MECHANICAL <br />G E N E R A L N O T E S: <br />A. REFER SHEET M000 FOR GENERAL NOTES. <br />B. COORDINATE INSTALLATION OF NEW DUCT W/ STRUCTURE. <br />C. CONTRACTOR TO INSTALL ALL WORK IN STRICT COMPLIANCE WITH LOCAL CODES AND <br />ORDINANCES. <br />D. MECHANICAL CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND EQUIPMENT <br />SUBMITTAL PRIOR TO INSTALLING OR FABRICATING ANY DUCTWORK. <br />E. PROVIDE ADJUSTABLE VOLUME DAMPER AT ALL BRANCH DUCTWORK. <br />F. ALL EXHAUST DUCT TERMINATIONS SHALL BE MAINTAINED 10 FEET AWAY FROM ANY <br />FRESH AIR INTAKES AND 3 FEET AWAY FROM ANY OPENING INTO THE BUILDING. <br />G. MECHANICAL CONTRACTOR SHALL COORDINATE WITH OTHER TRADES TO RELOCATE <br />ANY PIPES, CONDUITS, DEVICES, OR THE STRUCTURES THAT CONFLICT WITH PROVIDING <br />A LARGER DUCT OPENING. <br />H. CONTRACTOR TO PROTECT EXISTING EQUIPMENT'S ASSOCIATED DUCTWORK, PIPING <br />AND VALVES DURING THE CONSTRUCTION. <br />I. SEQUENCE OF OPERATIONS: MECHANICAL CONTRACTOR SHALL HIRE A CONTROLS OR <br />SELF PERFORM. COORDINATE EXACT REQUIREMENTS WITH THE OWNER AND PROVIDE <br />A MINIMUM OF (2) 1 HOUR TRAINING SESSIONS. CONTRACTOR SHALL PROVIDE ALL <br />NECESSARY HARDWARE AND PROGRAMMING TO ACHIEVE THE SEQUENCE OF <br />OPERATIONS. <br />a. EXISTING RTU AC-13: EXISTING CONTROL SEQUENCE SHALL REMAIN, <br />REBALANCE AIRFLOW AS SHOWN ON PLANS. <br />b. EXISTING RTU AC-14: EXISTING CONTROL SEQUENCE SHALL REMAIN, <br />REBALANCE AIRFLOW AS SHOWN ON PLANS, WITH EXCEPTION TO ADDING AN <br />INTERFACE WITH THE OVERHEAD DOOR. WHEN THE OVERHEAD DOOR IS OPEN, <br />AC-14 SHALL NOT ENGAGE THE COOLING OR HEATING COIL. THE SUPPLY FAN <br />SHALL REMAIN ENGAGED DURING OCCUPIED HOURS. <br />c. AC-1: PROVIDED WITH A STANDALONE CONTROLLER WITH ABILITY TO OPERATE <br />COMPRESSOR, DXCOIL, HEAT PUMP OPERATION, FAN, AND INTERLOCK <br />OPERATIONS WITH AC-13 TO ENSURE THE UNIT DOES NOT PROVIDE <br />SIMULTANEOUS HEATING AND COOLING. <br />FAN OPERATION: FAN TO RUN CONTINUOUSLY DURING OCCUPIED MODE. <br />DURING UNOCCUPIED MODE FAN SHALL RUN ON CALL FOR HEAT/COOL. <br />COOLING OPERATION:ON RISE IN SPACE TEMPERATURE ABOVE COOLING <br />SETPOINT, CONTROLLER SHALL MODULATE COMPRESSOR(S) AS REQUIRED TO <br />MEET COOLING SETPOINT. <br />HEATING OPERATION:ON DROP IN SPACE TEMPERATURE BELOW HEATING <br />SETPOINT, CONTROLLER SHALL MODULATE HEAT PUMP AS REQUIRED TO MEET <br />HEATING SET POINT. <br />PROVIDE EACH RTU WITH SPACE MOUNTED, 7-DAY PROGRAMMABLE <br />THERMOSTAT, WITH COLOR TOUCH SCREEN, AND USER ACCESS CONTROL. <br />PROGRAM PER OWNER'S REQUEST. <br />SETPOINTS (OCCUPIED): <br />COOLING = 74 DEGREES F (ADJ.) <br />HEATING = 70 DEGREES F (ADJ.) <br />SETPOINTS (UNOCCUPIED): <br />COOLING = 80 DEGREES F (ADJ.) <br />HEATING = 66 DEGREES F (ADJ.) <br />C O D E D N O T E S: <br />1. FULL SIZE EXISTING SUPPLY AIR AND RETURN AIR DUCT DROPS FROM EXISTING ROOF <br />MOUNTED AIR CONDITIONER UNIT (E) AC-13. <br />2.FULL SIZE EXISTING SUPPLY AIR AND RETURN AIR DUCT DROPS FROM EXISTING ROOF <br />MOUNTED AIR CONDITIONER UNIT (E) AC-14. <br />3.EXISTING SUPPLY AIR DIFFUSER TO REMAIN, CONTRACTOR TO USE SAME EXISTING <br />DUCTWORK AND RE BALANCE AIR FLOW AS PER NEW WORK PLAN. <br />4.EXISTING RETURN AIR GRILLE TO REMAIN, CONTRACTOR TO CONNECT WITH NEW <br />DUCTWORK AND RE BALANCE AIR FLOW AS PER NEW WORK PLAN. <br />5.EXISTING RETURN AIR GRILLE TO REMAIN, CONTRACTOR TO USE SAME EXISTING <br />DUCTWORK AND RE BALANCE AIR FLOW AS PER NEW WORK PLAN. <br />6.6"Ø EXHAUST AIR DUCT UP TO ROOF, REFER SHEET M201 FOR EXACT DUCT UP <br />LOCATION. <br />7.PROVIDE NEW 7-DAY PROGRAMMABLE THERMOSTAT WITH LOCKING COVER. LOCATE <br />THERMOSTAT AS SHOWN IN FLOOR PLAN. PROVIDE REMOTE SENSOR LOCATED 48" <br />A.F.F. NEAR LOCATION INDICATED. <br />8.RELOCATED 7-DAY PROGRAMMABLE THERMOSTAT WITH LOCKING COVER. LOCATE <br />THERMOSTAT AS SHOWN IN NEW WORK PLAN. PROVIDE REMOTE SENSOR LOCATED 48" <br />A.F.F. NEAR LOCATION INDICATED. <br />9.UNDERCUT DOOR 1/2 INCH TO ALLOW AIR TRANSFER. <br />10.PROVIDE INTERLOCK WITH OVERHEAD DOOR SUCH THAT WHEN OPENED, AC-14'S <br />COOLING AND HEATING OPERATIONS ARE NOT ENGAGED. THE FAN SHALL REMAIN <br />OPERATIONAL DURING OCCUPIED HOURS. <br />N02'4'8' <br />DESCRIPTION DATE <br />7/08/24 <br />Consulting Engineer <br />www.alphamep.net <br />505 E Central Ave <br />#B11/6/2024
The URL can be used to link to this page
Your browser does not support the video tag.