SPLIT SYSTEM INDOOR FAN COIL UNIT SCHEDULE <br />SYSTEM <br />MARK SERVICE SYSTEM TYPE QUANTITY SYSTEM <br />TONNAGE <br />FAN DATA DX COOLING COIL DATA HEATING COIL DATA ELECTRICAL DATA <br />DIMESNSIONS INCH (L x W x H)AIR FILTER <br />RATING <br />WEIGHT <br />(LBS)MANUFACTURER MODEL NOTES <br />SUPPLY AIR <br />FLOW (CFM) <br />ESP <br />(IN.WC.) <br />TOTAL <br />COOLING <br />CAPACITY <br />(MBH) <br />SENSIBLE <br />COOLING <br />CAPACITY <br />(MBH) <br />HEATING CAPACITY <br />(MBH)VOLT / PH / HZ MCA (A)MOCP (A) <br />AC-1 WORK ROOM CEILING RECESSED <br />CASSETTE 1 1 TON 406 -10.8 8.43 13.5 208 / 1 / 60 POWERED FROM <br />OUTDOOR UNIT 22-5/8 x 22-5/8 x 10-1/4 MERV 13 36 DAIKIN FFQ12Q2VJU ALL <br /> NOTES : <br />1 PROVIDE EQUIPMENT WITH INTEGRAL STARTER / DISCONNECT. <br />2 ROUTE AND SIZE REFRIGERANT PIPING AS PER MANUFACTURER'S RECOMMENDATION. <br />SPLIT SYSTEM OUTDOOR HEAT PUMP CONDENSING UNIT SCHEDULE <br />SYSTEM <br />MARK <br />CONNECTED INDOOR <br />UNITS LOCATION CAPACITY (TON) <br />COOLING <br />CAPACITY <br />(MBH) <br />HEATING <br />CAPACITY <br />(MBH) <br />EER / SEER HSPF <br />ELECTRICAL DATA <br />WEIGHT <br />(LBS) <br />DIMENSIONS (INCH) <br />MANUFACTURER MODEL NOTES <br />V / PH / HZ MCA (A)MOCP (A)LENGTH WIDTH HEIGHT <br />HP-1 AC-1 REFER PLAN 1 TON 10.8 13.5 12.5 / 20.20 11.2 208 / 1 / 60 8.6 15.0 60 26-9/19 42677.00 21-5/8 DAIKIN RX12QMVJU ALL <br /> NOTES : <br />1 PROVIDE EQUIPMENT WITH INTEGRAL STARTER / DISCONNECT. <br />2 PROVIDE BRINMAR SBUHD UNIVERSAL-FIT AIR CONDITIONER COMPRESSOR SOUND BLANKET. <br />EXHAUST FAN SCHEDULE <br />SYSTEM <br />MARK SERVICE TYPE <br />PERFORMANCE <br />V / PH / HZ FLA (AMPS)WEIGHT (LBS)DIMESNSIONS INCH (L x <br />W x H)MANUFACTURER MODEL NUMBER NOTES <br />AIR FLOW <br />(CFM) <br />E.S.P. <br />(IN.W.G.)FAN (RPM) MOTOR (WATT) <br />EF-1 RESTROOM CEILING MOUNTED 70 0.5 779 80 115 / 1 / 60 1.15 11.0 14.93 x 13.37 x 7 GREENHECK SP-B110 ALL <br /> NOTES : <br />1 PROVIDE EQUIPMENT WITH INTEGRAL STARTER / DISCONNECT. <br />2 PROVIDE FACTORY MOUNTED SAFETY DISCONNECT SWITCH. <br />3 PROVIDE WITH FACTORY INSTALLED BACK DRAFT DAMPER. <br />AIR DISTRIBUTION SCHEDULE <br />MARK CFM NECK SIZE FACE SIZE <br />LENGTH MAKE MODEL DESCRIPTION NOTES <br />A <br />000-120 6"Ø <br />- PRICE RCDA <br />PRICE ROUND CONE DIFFUSER <br />1,2121-210 8"Ø FULLY ADJUSTABLE FLOW PATTERNS <br />211-330 10"Ø 4 CONE DIFFUSER WITH 360° AIR PATTERN <br />331-470 12"Ø ROUND NECK WITH ALUMINIUM FRAME <br />B <br />000-270 10"x8" <br />- PRICE 610Z <br />PRICE ALUMINIUM LOUVERED GRILLE <br />1,2271-480 14"x10"3/4 INCH BLADE SPACING <br />481-960 26"x10"ZERO DEGREE BLADE DEFLECTION <br />NOTES: <br />1. COORDINATE FINISH WITH ARCHITECTURAL. <br />2. COORDINATE BORDER TYPES WITH ARCHITECTURAL FLOOR PLAN AND REFLECTED CEILING PLAN. <br />DUCT INSULATION TABLE <br />DUCT SERVICES <br />MINIMUM <br />INSULATION <br />THICKNESS (IN) <br />DENSITTY <br />(LB/CU.FT.) <br />"R" VALUE <br />(HR.SQ.FT. ° <br />F/BTU) <br />MAXIMUM FLAME <br />SPREAD INDEX <br />MAXIMUM SMOKE <br />DEVELOPED INDEX <br />ALL DUCTWORK TYPES CONCEALED WITHIN A RETURN <br />PLENUM 1.5 1.5 4.2 25 50 <br />INDOOR CONCEALED SUPPLY AIR 1.5 1.5 4.2 25 450 <br />INDOOR CONCELAED RECOVERED EXHAUST AND OUTSIDE <br />AIR 1.5 1.5 4.2 25 450 <br />INDOOR CONCEALED EXHAUST DUCT BETWEEN BACKDRAFT <br />DAMPER AND PENETRATION OF BUILDING EXTERIOR 1.5 1.5 4.2 25 450 <br />OUTDOOR EXPOSED RECOVERED EXHAUST AND OUTSIDE AIR 3 3 8.3 25 450 <br />OUTDOOR EXPOSED DUCTING WILL REQUIRE FIELD APPLIED ALUMINUM JACKET. SEE SPECIFICATIONS FOR MORE INFORMATION. MAY USE MINERAL FIBER <br />BOARD/ FLEXIBLE ELASTOMERIC <br />COORDINATION <br />CONTRACTORS SHALL PROVIDE COORDINATION <br />DRAWINGS PRIOR TO DISTRIBUTION OF SUBMITTALS <br />AND ORDERING EQUIPMENT. COORDINATION <br />DRAWINGS SHALL SHOW CLEAR INDICATED OF <br />COORDINATION WITH OTHER TRADES, INCLUDING <br />STRUCTURAL, CEILINGS, AND FIRE PROTECTION. <br />ANY CONFLICTS SHALL BE BROUGHT TO THE <br />ATTENTION OF THE OWNER / ARCHITECT /ENGINEER <br />PRIOR TO ROUGH-IN OR ORDERING OF EQUIPMENT. <br />MAINTAIN MANUFACTURER RECOMMENCED <br />CLEARANCES AND ACCESS TO ALL REMOVABLE <br />PANELS AND DOORS. <br />ALL FILTERS SHALL BE FULL SIZE AND STANDARD <br />SIZE AND ACCESS SHALL ALLOW FOR EASY <br />REPLACEMENT OF FILTERS. <br />GENERAL EQUIPMENT NOTES <br />ALL EQUIPMENT REQUIRING VFD'S OR STARTERS SHALL BE PROVIDED <br />WITH THE <br />EQUIPMENT. VFD'S SHALL BE EQUIPPED WITH INTEGRAL DISCONNECTS. <br />ANY <br />OUTDOOR VFD'S SHALL BE PROVIDE WITH NEMA 3R ENCLOSURE, <br />COORDINATE WITH EC TO PROVIDE POWER FOR THE ENCLOSURE (IF <br />NEEDED). <br />UNLESS NOTED OTHERWISE, EQUIPMENT SHALL COME WITH INTEGRAL <br />DISCONNECTS AND SINGLE POINT ELECTRICAL CONNECTIONS. <br />COORDINATE ANY CHANGES OF EQUIPMENT LOCATIONS, SELECTIONS <br />AND RFI'S WITH THE ELECTRICAL AND PLUMBING CONTRACTORS AND <br />OTHER TRADES <br />EXISTING GAS FIRED ROOF TOP UNIT SCHEDULE <br />SYSTEM <br />MARK SERVICE <br />NOMINAL <br />CAPACITY <br />(TONS) <br />FAN DATA DX COOLING COIL DATA GAS HEATING DATA <br />AFUE <br />(%)EER SEER <br />ELECTRICAL DATA <br />WEIGHT <br />(LBS)MANUFACTURER MODELOUTSIDE AIR <br />FLOW (CFM)SUPPLY AIR <br />FLOW (CFM) <br />ESP <br />(IN.WC.) <br />TOTAL <br />COOLING <br />CAPACITY <br />(MBH) <br />SENSIBLE <br />COOLING <br />CAPACITY <br />(MBH) <br />OUTPUT <br />HEATING <br />CAPACITY <br />(MBH) <br />INPUT <br />HEATING <br />CAPACITY <br />(MBH) <br />VOLT / PH / HZ MCA (A) FLA (A) <br />(E) AC-13 OFFICE & HALLWAY 2 TON 160 800 0.50 24.1 18.60 38.0 50.0 79.0 10.8 12.3 460 / 3 / 60 20.0 4.3 450 LENNOX GCS20RV-261-50 <br />(E) AC-14 CHILDRENS AREA 5 TON 585 2000 0.50 63.2 46.10 72.7 92.0 79.0 10.3 - 460 / 3 / 60 20.0 4.8 800 LENNOX LGA060H <br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS <br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF <br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY <br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR <br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA <br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018. <br />SCALE: <br />REVISIONS: <br />OW <br />N <br />E <br />R <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />CL <br />I <br />E <br />N <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707 <br />T 949.809.3380 WWW.SVA-ARCHITECTS.COM <br />DATE ISSUED: <br />PROJECT NO: <br />Consulting Engineer <br />www.alphamep.net <br />NTS <br />Issue Date <br />M601 <br />SCHEDULES - <br />MECHANICAL <br />23-020-01 <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />DE <br />L <br />H <br />I <br /> <br />C <br />O <br />M <br />M <br />U <br />N <br />I <br />T <br />Y <br /> <br />C <br />E <br />N <br />T <br />E <br />R <br />RE <br />N <br />O <br />V <br />A <br />T <br />I <br />O <br />N <br />50 <br />5 <br /> <br />E <br /> <br />C <br />e <br />n <br />t <br />r <br />a <br />l <br /> <br />A <br />v <br />e <br />, <br /> <br />U <br />n <br />i <br />t <br /> <br />B <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />DESCRIPTION DATE <br />505 E Central Ave <br />#B11/6/2024