My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2200 E 17th St - REV 1 - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Seventeenth St
>
2200 E Seventeenth St
>
2200 E 17th St - REV 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:01:21 AM
Creation date
2/24/2026 5:00:42 AM
Metadata
Fields
Template:
Plan
Permit Number
101118782
101123571
Full Address
2200 E Seventeenth St
Street Number
2200
Street Direction
E
Street Name
Seventeenth
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Project No. Sheet No. 3/4 <br />Project <br />Prepared By Date 1/26/2024 <br />ASCE 7-16 (13.3) Component Analysis <br />ap 1.0 Component amplification factor, varies from 1.0-2.5 (Table 13.5-1 or 13.6-1) <br />SDS 1.032 Section 11.4.4 <br />Ip 1.0 Component importance factor, varies from 1.0 to 1.5 (Section 13.1.3) <br />Wp 2.7 psf Component operating weight* <br />Rp 2.5 Component response modification factor, varies from 1.5 to 5.0 (Table13.5-1 or 13.6-1) <br />z 11 ft <br />h 20 ft Average roof height of structure with respect to the base <br />w 144 in Width of opening <br />s 14 in o.c.Spacing of screws along track <br />Seismic force shall be determined in accordance with Equation13.3-1 - 13.3-3: <br />Fp1 = 0.94 psf <br />(Equation 13.3-1) <br />Seismic force not required to be taken as greater than: <br />Fp2 = 4.46 psf <br />(Equation 13.3-2) <br />And seismic force shall not be taken as less than: <br />Fp3 = 0.84 psf <br />(Equation 13.3-3) <br />Selects the appropriate seismic force from above <br />Fp = 0.94 psf <br />Force tributary to side rails <br />wE = 5.62 plf <br />Pull-out force per screw <br />PE = 6.55 lbs <br />24056 <br />NGW <br />Height in structure of point of attachment of component with respect to the base. For items at or below the base, z = <br />0. Value of z/h < 1 <br />Ross #397 Santa Ana CA <br /> <br />0.4 · ·<br />· <br /> <br /> <br />·1 2 · <br /> <br />ℎ <br />1.6 ·<br />·· <br />0.3 ·<br />·· <br />Seismic Attachment for Security <br /> <br />∗ <br />2 <br /> ∗ <br />2200 E 17th St - <br />1011187827/18/2024
The URL can be used to link to this page
Your browser does not support the video tag.