Laserfiche WebLink
PAGE <br />REV: A1 10/6/2024 <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603   <br />FAX 949.215.7778 <br />EFREN LUMBRERAS <br />2100 E WELLINGTON AVE,  <br />SANTA ANA, CA, 92701 <br />PROJECT NUMBER: <br />  109R-100LUMB <br />SHEET <br />DESIGNER: <br />HIMANSHU VASHIST <br />CUSTOMER RESIDENCE: <br />TEL. (949) 763-0025 <br />APN: 400-153-29 <br />GILBERT CORREIA, C10, C46 <br />CA CL #750184 <br />(415) 580-6920 ex3 <br />PV-4.1 <br />ELECTRICAL CALCS <br />Template_version_v5_2024 02 28 <br />ELECTRICAL CALCS <br />SYSTEM INFORMATION <br />4 KW DC PHOTOVOLTAIC SYSTEM <br />     (10) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-400M, TESLA: POWERWALL 3 1707000-XX-Y <br />ALLOWABLE BACKFEED <br />ALLOWABLE BACKFEED = MAIN PANEL RATING = <br />100A <br />LOADS IN MAIN PANEL: 30A LOADS + 70A GATEWAY BREAKER = 100A ≤ 100A <br />INTERCONNECTION MEETS CEC 2022 705.12(B)(3)(3) REQUIREMENTS. <br />GATEWAY SYSTEM AC WIRE SIZING <br />MAX AC OUTPUT CURRENT = 70 A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =  <br />0.91 X 1 X 95A = 86.45A <br />TERMINAL RATING[110.14(C)] = <br />4 AWG, 75°C RATED = 85A <br />85A < 86.45A   TERMINAL RATING GOVERNS CONDUCTOR SIZING <br />70A < 85A   4 AWG AMPACITY OK <br />THEREFORE 4 AWG IS SUFFICIENT. <br />INVERTER OVERCURRENT PROTECTION <br />(INVERTER MAX CURRENT) X (CONTINUOUS LOAD) =  <br />48 A X 1.25 = 60 A → 60 A OVERCURRENT PROTECTION PER MANUFACTURER <br />DC WIRE SIZING <br />MAX CIRCUIT CURRENT = (MODULE ISC) X (HIGH IRRADIANCE)[690.8(A)(1)] X (CONTINUOUS LOAD)[690.8(B)(1)]= <br />     14.88A X 1.25 = 18.6A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] = <br />     0.91 X 1 X 40A = 36.4A <br />TERMINAL RATING[110.14(C)] = <br />     10 AWG, RATED = 35A <br />35A < 36.4A → TERMINAL RATING GOVERNS CONDUCTOR SIZING. <br />     18.6A < 35A → 10 AWG AMPACITY OK <br />THEREFORE 10 AWG IS SUFFICIENT. <br />AC WIRE SIZING <br />MAX AC OUTPUT CURRENT = (MAX INVERTER OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)] = <br />48 A X 1.25 = 60 A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =  <br />0.91 X 1 X 75A = 68.25A <br />TERMINAL RATING[110.14(C)] = <br />6 AWG,  RATED = 65A <br />65A < 68.25A →  ADJUSTED CONDUCTOR AMPACITY GOVERNS CONDUCTOR SIZING. <br />60A < 65A → 6 AWG AMPACITY OK <br />THEREFORE 6 AWG IS SUFFICIENT. <br />SYSTEM CHARACTERISTICS <br />MAX OPEN CIRCUIT VOLTAGE   = {[((TEMP COEF VOC) X (VOC)) / 100] X [LOW TEMP - STC TEMP] + VOC} X (# MODULES / STRING) = <br />{[(-0.26 %/°C X 37.05 V) / 100] X [-2 °C - 25 °C] + 37.05 V} X 10 = 397 V <br />SHORT CIRCUIT CURRENT = 1.25 X (MODULE ISC) X (# STRINGS) <br />1.25 X 14.88 A X 1 = 18.6A <br />2100 E Wellington <br />Ave11/18/2024