Laserfiche WebLink
CITY OF SANTA ANA <br />Planning aqd-Mild-ink-Agency <br />FIRE NOTE <br />1. FIRE SPREAD AND SMOKE -DEVELOPED INDICES FOR WALL AND <br />CEILING FINISHES SHALL BE IN ACCORDANCE WITH SECTIONS <br />R302.9.1 AND R302.9.4 <br />WATER HEATER /ELECTRICAL READY <br />1.AT TANKLESS WATER HEATER -PROVIDE A DEDICATED 125 VOLT, <br />20 AMP ELECTRICAL PANEL WITH A 120/ 240 VOLT 3 CONDUCTOR <br />10 AWG COPPER BRANCH CIRCUIT, WITHIN 3 FEET OF THE WATER <br />HEATER AND ACCESSIBLE TO THE WATER HEATER. (CENERGYC) <br />150.0(N)(1)(A) <br />2. WATER HEATING SYSTEMS (ESS) READY. ALL SINGLE-FAMILY <br />RESIDENCES THAT INCLUDE ONE OR TWO DWELLING UNITS SHALL <br />MEET THE FOLLOWING. ALL ELECTRICAL COMPONENTS SHALL BE <br />INSTALLED IN ACCORDANCE WITH THE CALIFORNIA ELECTRICAL <br />CODE: (CENERGYC150.0(S) <br />AT LEAST ONE OF THE FOLLOWING SHALL BE PROVIDED: <br />A. ESS READY INTERCONNECTION EQUIPMENT WITH A MINIMUM <br />BACKED -UP CAPACITY OF 60 AMPS AND A MINIMUM OF FOUR <br />ESS-SUPPLED BRANCH CIRCUITS, OR <br />B. A DEDICATED RACEWAY FROM THE MAIN SERVICE PANELBOARD <br />(SUBPANEL) THAT SUPLIES THE BRANCH CIRCUITS IN SECTION <br />150.0 (S)(2). ALL BRANCH CIRCUITS ARE PERMITTED TO BE <br />SUPPLIED BY THE MAIN SERVICE PANEL PRIOR TO THE <br />INSTALLATION OF AN ESS. THE TRADE SIZE OF THE RACEWAY <br />SHALL BE NOT LESS THAN 1 INCH . THE PANELBOARD THAT <br />SUPPLIES THE BRANCH CIRCUITS(SUBPANEL) MUST BE LABELED " <br />SUBPANEL SHALL INCLUDE ALL BACKED UP LOAD CIRCUITS." <br />3. A MINIMUM OF FOUR BRANCH CIRCUITS SHALL BE IDENTIFIED <br />AND HAVE THEIR SOURCE OF SUPPLY COLLOCATED AT A SINGLE <br />PANELBOARD SUITABLE TO BE SUPPLIED BY THE ESS. AT LEAST <br />ONE CIRCUIT SHALL SUPPLY THE REFRIGERATOR, ONE LIGHTING <br />CIRCUIT SHALL BE LOCATED NEAR THE PRIMARY EGRESS AND AT <br />LEAST ONE CIRCUIT SHALL SUPPLY A SLEEPING ROOM <br />RECEPTACLE OUTLET. <br />4. THE MAIN PANELBOARD SHALL HAVE A MINIMUM BUSBAR RATING <br />OF 225 AMPS. <br />5. SUFFICIENT SPACE SHALL BE RESERVED TO ALLOW FUTURE <br />INSTALLATION OF A SYSTEM ISOLATION EQUIPMENT/TRANSFER <br />SWITCH WITHIN 3 FEET OF THE MAIN PANELBOARD. RACEWAYS <br />SHALL BE INSTALLED BETWEEN THE PANELBOARD AND THE <br />SYSTEM ISOLATION EQUIPMENT/TRANSFER SWITCHED LOCATION TO <br />ALLOW THE CONNECTION OF BACK UP POWER SOURCE. <br />ELECTRICAL COOKTOP DRYER READY <br />6. ELECTRIC COOKTOP READY.SYSTEMS USING GAS OR PROPANE <br />COOKTOP TO SERVE INDIVIDUAL DWELLING UNITS SHALL INCLUDE <br />THE FOLLOWING: (CENERGY C 150.0(U) <br />A. A DEDICATED 240 VOLT BRANCH CIRCUIT WIRING SHALL BE <br />INSTALLED WITHIN 3 FEET FROM THE COOKTOP AND ACCESSIBLE TO <br />THE COOKTOP WITH NO OBSTRUCTIONS. THE BRANCH CIRCUIT <br />CONDUCTORS SHALL BE RATED AT 50 AMPS MINIMUM THE <br />BLANK COVER SHALL BE IDENTIFIED AS "240V READY." ALL <br />ELECTRICAL COMPONENTS SHALL BE INSTALLED IN ACCORDANCE <br />WITH THE CALIFORNIA ELECTRICAL CODE. <br />B. THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED <br />SPACE TO ALLOW FOR THE INSTALLATION OF A DOUBLE POLE <br />CIRCUIT BREAKER FOR A FUTURE ELECTRIC CLOTHES DRYER <br />INSTALLATION. THE RESERVED SPACE SHALL BE PERMANENTLY <br />MARKED AS "FOR FUTURE 240V USE." <br />ELECTRICAL CLOTHE DRYER READY <br />ELECTRIC CLOTHES DRYER READY. CLOTHES DRYER LOCATIONS WITH <br />GAS OR PROPANE PLUMBING TO SERVE INDIVIDUAL DWELLING UNITS <br />SHALL INCLUDE THE FOLLOWING: (CENERGYC150.0(V) <br />1. A DEDICATED 240 VOLT BRANCH CIRCUIT WIRING SHALL BE <br />INSTALLED WITHIN 3 FEET FROM THE CLOTHES DRYER LOCATION <br />AND ACCESSIBLE TO THE CLOTHES DRYER LOCATION WITH NO <br />OBSTRUCTIONS. THE BRANCH CIRCUIT CONDUCTORS SHALL BE <br />RATED AT 30 AMPS MINIMUM. THE BLANK COVER SHALL BE <br />IDENTIFIED AS "240V READY." ALL ELECTRICAL COMPONENTS SHALL <br />BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA ELECTRICAL <br />CODE. <br />2. THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED <br />SPACE SHALL BE PERMANENTLY MARKED AS "FOR FUTURE 240V <br />USE. <br />ELECTRICAL <br />1. IN BATHROOMS AND LAUNDRY ROOMS, NAT LEAST ONE <br />LUMINAIRE IN EACH OF THESE SPACES MUST BE CONTOLLED BY <br />AN OCCUPANT SENSOR OR A VACANCY SENSOR PROVIDING <br />AUTOMATIC -OFF FUNCTIONALLY. IF AN OCCUPANT SENSOR IS <br />INSTALLED, IT MUST BE INITIALLY CONFIGURED TO MANUAL -ON <br />OPERATON USING THE MANUAL CONTROL REQUIRED UNDER SECTION <br />150.0(K)21. <br />2. SERVICES DISCONNECTING MEANS SHALL BE INSTALLED OUTSIDE THE <br />BUILDING OR INSIDE NEARAST THE POINT OF ENTRANCE OR SERVICE <br />CONDUCTORS. (CEC 230.70) <br />3. NEWLY CONSTRUCTED ONE AND TWO FAMILY DWELLINGS AND <br />TOWNHOUSES WITH ATTACHED PRIVATE GARAGES SHALL COMPLY WITH <br />THE EV CHARGING INFRASTRUCTURE REQUIREMENTS IN CGBC 4.106 AND <br />CRC R309.8 <br />LIGHTING MEASURES <br />1. LIGHTING IN BATHROOMS, GARAGES, AND LAUNDRY ROOMS,WALK IN <br />CLOSETS AND UTILITY ROOMS. ALL LUMINAIRES SHALL BE HIGH <br />EFFICACY AND SHALL BE CONTROLLED BY AN OCCUPANCY OR VACANCY <br />SENSOR. <br />2. HABITABLE SPACES. ALL LUMINAIRES SHALL BE HIGH EFFICACY AND <br />SHALLN BE CONTROLLED BY A VACANCY/OCCUPANCY SENSOR OR <br />DIMMER. <br />3. OUTDOOR LIGHTING. ALL LUMINAIRES MOUNTED TO THE BUILDING ON <br />THE SAME LOT SHALL BE HIGH EFFICACY LUMINAIRES AND SHALL BE <br />CONTROLLED BY A PHOTOCONTROL/MOTION SENSOR COMBINATION (WITH <br />OVERRIDE). SEE 150(k) 3 FOR REQUIREMENTS. <br />4. KITCHEN ALL INSTALLED WATTAGE IN KITCHEN SHALL BE HI <br />EFFICACY. <br />GLAZING <br />1. GLAZING IN THE FOLLOWING LOCATIONS SHALL BE SAFETY <br />GLAZING CONFORMING TO THE HUMAN IMPACT LOADS OF SECTION <br />R308.3 . <br />A. FIXED AND OPERABLE PANELS OF SWINGING, SLIDING AND <br />BI-FOLD DOOR ASSEMBLIES. <br />B. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL <br />ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE IS <br />WITHIN A 24 INCH ARC OF EITHER VERTICAL EDGE OF THE DOOR IN <br />A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 <br />INCHES ABOVE THE FLOOR OR WALKING SURFACE. <br />C. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL THAT <br />MEETS ALL OF THE FOLLOWING CONDITIONS: <br />GLAZING <br />1. EXPOSED AREA OF AN INDIVIDUAL PANEL GREATER THAN 9 <br />SQUARE FEET. <br />2. BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR . <br />3. TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR. <br />4. ONE OF MORE WALKING SURFACES WITHIN 36 INCHES <br />HORIZONTALLY OF THE GLAZING. <br />D. GLAZING IN RAILINGS. <br />E. GLAZING IN ENCLOSURES FOR OR WALLS FACING HOT TUBS, <br />WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS AND SHOWERS <br />WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60 <br />INCHES MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING <br />SURFACE. <br />AGING -IN- P LACE/FALL <br />1. REINFORCEMENT FOR GRAB BARS. (R327.1.1) AT LEAST ONE <br />BATHROOM ON THE ENTRY LEVEL SHALL BE PROVIDED WITH <br />REINFORCEMENT INSTALLED IN ACCORDANCE WITH THIS SECTION. WHERE <br />THERE IS NO BATHROOM ON THE ENTRY LEVEL, AT LEAST ONE <br />BATHROOM ON THE 2ND OR 3RD FLOOR OF THE DWELLING SHALL <br />COMPLY WITH THIS SECTION. <br />A. REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTION <br />MATERIALS APPROVED BY THE ENFORCING AGENCY. <br />B. REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCH NOMINAL <br />LUMBER (1-1/2" X 7-1/4" ACTUAL DIMENSION) OR OTHER <br />CONSTRUCTION MATERIAL PROVIDING EQUAL HEIGHT AND LOAD <br />CAPACITY. REINFORCEMENT SHALL BE LOCATED BETWEEN 32" AND <br />39-1 /4" ABOVE THE FINISHED FLOOR, FLUSH WITH THE WALL FRAMING. <br />C. WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE <br />WALLS OF THE FIXTURE, OR ONE SIDE WALL AND THE BACK WALL. <br />D. SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL <br />FRAMING IS PROVIDED. <br />E. BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT <br />SHALL BE CONTINUOUS ON EACH END OF THE BATHTUB AND THE <br />BACK WALL. ADDITIONALLY, BACK WALL REINFORCEMENT FOR A LOWER <br />GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE LOCATED NO <br />MORE THAN 6" ABOVE THE BATHTUB RIM. <br />F. WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO A SIDE <br />WALL CAPABLE OF ACCOMMODATING A GRAB BAR, THE BATHROOM <br />SHALL HAVE PROVISIONS FOR INSTALLATION OF FLOOR MOUNTED, <br />FOLDAWAY OR SIMILAR ALTERNATE GRAB BAR REINFORCEMENTS <br />APPROVED BY THE ENFORCING AGENCY. <br />1. DOCUMENTATION FOR GRAB BAR REINFORCEMENT. (R327.1.1.1) <br />INFORMATION AND /OR DRAWINGS IDENTIFYING THE LOCATION OF GRAB <br />BAR REINFORCEMENT SHALL BE PLACED IN THE OPERATION AND <br />MAINTENANCE MANUAL IN ACCORDANCE WITH THE CALIFORNIA GREEN <br />BUILDING STANDARDS CODE. CH 4, DIVISION 4.4. <br />2. ELECTRICAL RECEPTACLE OUTLET, SWITCH AND CONTROL HEIGHTS. <br />(R327.1.2.) ELECTRICAL RECEPTACLE OUTLETS, SWITCHES, AND <br />CONTROLS (INCLUDING CONTROLS FOR HEATING, VENTILATION AND AIR <br />CONDITIONING ) INTENDED TO BE USED BY OCCUPANTS SHALL BE <br />LOCATED NO MORE THAN 48" MEASURED FROM THE TOP OF THE <br />OUTLET BOX AND NOT LESS THAN 15" MEASURED FROM THE BOTTOM <br />OF THE OUTLET BOX ABOVE THE FINISHED FLOOR. <br />3. INTERIOR DOORS. (R327.1.3) EFFECTIVE JULY 1.2024 AT LEAST <br />ONE BATHROOM AND ONE BEDROOM ON THE ENTRY LEVEL SHALL <br />PROVIDE A DOORWAY WITH A NET CLEAR OPENING OF NOT LESS THAN <br />32", MEASURED WITH THE DOOR POSITIONED AT AN ANGLE OF 90 <br />DEGREES FROM THE CLOSED POSITION; OR, IN THE CASE OF A 2- OR <br />3- STORY SINGLE FAMILY DWELLING, ON THE 2ND OR 3RD FLOOR OF <br />THE DWELLING IF A BATHROOM OR BEDROOM IS NOT LOCATED ON THE <br />ENTRY LEVEL. <br />4. DOORBELL BUTTONS. (R327.1.4) DOORBELL BUTTONS OR CONTROLS, <br />WHEN INSTALLED, SHALL NOT EXCEED 48" MEASURED FROM THE <br />EXTERIOR FLOOR OR LANDING, A STANDARD DOORBELL BUTTON OR <br />CONTROL SHALL ALSO BE PROVIDED AT A HEIGHT NOT EXCEEDING 48" <br />ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF <br />THE DOORBELL BUTTON OR CONTROL. <br />NOTES: <br />1. BATHTUB AND SHOWER FLOORS, AND WALLS ABOVE BATHTUBS WITH A <br />SHOWERHEAD, AND SHOWER COMPARTMENTS SHALL BE FINISHED WITH A <br />NONABSORBENT SURFACE EXTENDING TO A HEIGHT OF NOT LESS THAN 6 <br />FEET ABOVE THE FLOOR. <br />2. SHOWER DOORS SHALL SWING OUT. NET AREA OF SHOWER RECEPTOR <br />SHALL BE NOT LESS THAN 1,024 SQ . IN. OF FLOOR AREA, AND ENCOMPASS <br />30 IN. DIAMETER CIRCLE. <br />3. ALL HOSE BIBBS MUST BE PROTECTED BY AN ANTI -SIPHON DEVICE <br />4. TAMPER -RESISTANT RECEPTACLES SHALL BE INSTALLED IN ALL AREAS <br />SPECIFIED IN 210.52 ALL NONLOCKING-TYPE 12 VOLT, 15- AND 20 AMPERE <br />RECEPTACLES SHALL BE LISTED TAMPER -RESISTANT RECEPTACLES. <br />5. ALL SHOWERS AND TUB -SHOWERS SHALL HAVE A PRESSURE BALANCE, <br />THERMOSTATIC MIXING VALVE, OR A COMBINATION PRESSURE <br />BALANCE/THERMOSTATIC MIXING TYPE VALVE. <br />6. ALL NEW, REPLACEMENT AND EXISTING WATER HEATERS SHALL BE STRAPPED <br />TO THE WALL IN TWO PLACES. ONE IN THE UPPER 1/3 OF THE TANK AND ONE IN <br />THE LOWER 1/3 OF THE TANK. THE LOWER POINT SHALL BE A MINIMUM OF 4-IN. <br />ABOVE THE CONTROLS. <br />7. ALL FINISHED MATERIALS, SUCH AS ADHESIVES, SEALANTS, CAULKS, PAINTS, <br />AEROSOL PAINTS , COATINGS, CARPET SYSTEMS, RESILIENT FLOORING SYSTEMS <br />AND COMPOSITE WOOD PRODUCTS SHALL CONFORM TO THE VOC AND <br />FORMALDEHYDE LIMITS SET SET FORTH IS SECTION 4.504.2, 4.504.4. 4.504.5 <br />AND TABLES 4.504.1, 4.504.2, 4.504.3 AND 4.504.5 2019 CGB SC <br />8. SHOWER OR TUB EQUIPPED WITH A SHOWERHEAD SHALL HAVE A MINIMUM <br />CELING HEIGTH OF 6-8" ABOVE A MINIMUM AREA OF 30"X30" AT THE SHOWER <br />HEAD <br />9. WATER HEATERS SHALL HAVE A TEMPERATURE AND PRESSURE RELIEF VALVE <br />COMPLYING WITH CPC SECTIONS 505.4 & 608.6. THE POINT OF DISCHARGE FOR <br />RELIEF VALVE SHALL BE IN ACCORDANCE WITH CPC SECTION 608.7 <br />10. THE SEWER LINE FOR THE APPROVED ADU MUST CONNECT TO THE MAIN <br />LATERAL SEWER LINE PRIOR TO THE CONNECTION OF THE MAIN RESIDENCE. <br />11. EACH BATHROOM CONTAINING A BATHTUB, SHOWER OR TUB/SHOWER <br />COMBINATION SHALL BE MECHANICALLY VENTILATED FOR PURPOSES OF HUMIDITY <br />CONTROL IN ACCORDANCE WITH CMC, CHAPTER 4 AND CGBSC, CHAPTER 4, <br />DIVISION 4.5. (R303.3.1. CRC) <br />12. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS <br />SHALL BE PROVIDED WITH GLAZED AREA IN WINDOWS OF NOT LESS THAN 3 SQ, FT, <br />ONE HALF SHALL BE OPENABLE .(R303.3 CRC) <br />EXCEPTION: GLAZED AREA SHALL NOT BE REQUIRED WHERE ARTIFICIAL LIGHT <br />AND MECHANICAL VENTILATION ARE PROVIDED. MINIMUM VENTILATION RATES <br />SHALL BE 50 CFM FOR INTERMITENT VENTILATION AND 25 CFM OF CONTINOUS <br />VENTILATION AND VENTED DIRECTLY TO THE OUTSIDE. <br />CALIFORNIA MECHANICAL CODE: <br />1. 120 -VOLT RECEPTACLE COMPLYING WITH CMC SECTION 309 SHALL <br />BE LOCATED WITH 25' OF THE EQUIPMENT FOR SERVICE AND <br />MAINTAINANCE PURPOSES. <br />2. AN APPROVED INDEPENDENT ELECTRICAL DISCONNECT COMPLYING <br />IWTH CMC SECTION 309 IS REQUIRED FOR EACH PIECE OF EQUIPMENT <br />WITHIN SIGHT OF THE EQUIPMENT, WHEN SUPPLY VOLTAGE IS GREATER <br />THAN 50 VOLTS. <br />3. CONDENSATE LINES FROM MECHANICAL EQUIPMENT SHALL <br />DISCHARGE TO A PLUMBING FIXTURE OR STORM DRAINAGE BY MEANS <br />OF AN INDIRECT WASTE PIPE. CONSENSATE LINES SHALL NOT <br />TERMINATE IN A LANDSCAPE OR YARD AREAS. <br />4. WHEN APPROVED, THE ENGINEER OF RECORD, ARCHITECT OR PLANS <br />PREPARER SHALL PROVIDE MANUFACTURE'S DETAILS AND <br />SPECIFICATIONS FOR VENTING OF TANKLESS WATER HEATERS. <br />5. A DRYER COMPARTMENT/CLOSET SHALL BE PROVIDED WITH A <br />MINIMUM OPENING OF 100 SQ INCHES FOR MAKE UP AIR IN THE DOOR <br />OR BY OTHER APPROVED MEANS IN ACCORDANCE WITH CMC SECTION <br />504.3.1. <br />6. A DOMESTIC CLOTHE DRYER DUCT SHALL BE OF METAL AND A <br />MINIMUM OF 4" DIAMETER. THE EXHAUST DUCT SHALL NOT EXCEED A <br />TOTAL COMBINED HORIZONTAL AND VERTICAL LENGTH OF 14', <br />INCLUDING TWO 90-DEGREE ELBOWS. TWO FEET SHALL BE DEDUCTED <br />FOR EACH 90-DEGREE ELBOW IN EXCESS OF TWO. THE DRYER SHALL <br />BE VENTED TO THE OUTSIDE AIR. CMC SECTIONS 504.3.1. <br />1. EXHAUST FANS SHALL BE SWITCHED SEPARATELY FROM THE LIGHTING <br />SYSTEMS SECTION 150.0 (K) (2) (B). <br />2. EXHAUST FANS FOR BATHROOM AND LAUNDRY ROOM 50 CFM <br />3. EXHAUST DUCTS SHALL TERMINATE OUTSIDE THE BUILDING AND SHALL BE <br />EQUIPPED WITH BACK DRAFT DAMPERS OR WITH MOTORIZED DAMPERS THAT <br />AUTOMATICALLY SHUT WHERE THE SYSTEM OR SPACES SERVED ARE NOT IN <br />USE. CMC.504.1.1 <br />4. EXHAUST OPENINGS TERMINATING TO THE OUTDOORS SHALL BE COVERED <br />WITH A CORROSION RESISTANT SCREEN HAVING NOT LESS THAN 4" OF AN INCH <br />OPENING AND SHALL HAVE NOT MORE THAN 2" INCH OPENING AND SHALL HAVE <br />NOT MORE THAN 2" INCH OF AN OPENINGS. CMC 502.1. <br />CALIFORNIA RESIDENTIAL CODE <br />1. WALL AND CEILING SHALL NOT EXCEED THE FLAME -SPREAD <br />CLASSIFICATIONS IN CRC SECTKION R302.9 <br />2. INTERIOR WALL COVERING SHALL COMPLY WITH THE <br />REQUIREMENTS CITED IN CRC SECTION 702 AND TABLE R702.3.5 <br />FOR THE APPROVED MATERIALS (FASTENERS, FASTENER SPACING <br />COATING THICKNESS, NUMBER OF COATS, ETC. <br />3. CEMENT, FIBER -CEMENT, FIBER MAT REINFORCED CEMENT, <br />GLASS MAT GYPSUM OR FIBER -REINFORCED GYPSUM BACKERS <br />SHALL BE USED AS A BASE FOR WALL TILE IN TUB AND SHOWER <br />AREAS AND CEILING PANELS IN SHOWER AREAS IN ACCORDANCE <br />WITH CRC SECTION R702.4.2 CRC. <br />4. FASTENERS FOR ROOF COVERING SHALL BE CORROSION <br />RESISTAN SUCH AS COPPER, BRASS, STAINLESS STEEL OR <br />GALVANIZED. (CRC) TABLES R602.3(10) AND R502.3(2) <br />5. EACH PANE OF SAFETY GLAZING INSTALLED IN HAZARDOUS <br />LOCATIONS SHALL BE IDENTIFIED (ACID ETCHED, SAND BLASTED, <br />CERAMIC FIRED, ETC) BY A MANUFACTURE'S DESIGNATION, THE <br />MANUFACTURER OR INSTALLER AND SAFETY GLAZING STANDARD <br />WHICH IT COMPLIES. <br />6. FIRE BLOCKING MUST BE PROVIDED IN ACCORDANCE WITH CRC <br />SECTION R302.11 AT THE FOLLOWING LOCATIONS: <br />A. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, <br />INCLUDING FURRED SPACES, AT THE CEILING AND FLOOR LEVELS <br />B. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, <br />INCLUDING FURRED SPACES, AT 10-FOOT INTERVALS ALONG THE <br />LENGTH OF THE WALL. <br />C. AT ALL INTERCONNECTIONS BEWEEN CONCEALED VERTICAL AND <br />HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS <br />AND COVE CEILINGS. <br />D. IN OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS, FIRE <br />PALCES AND SIMILAR OPENINGS WHICH AFFORD A PASSAGE FOR <br />FIRE AT CEILING AND FLOOR LEVELS, WITH MATERIALS TESTED FOR <br />THE FORM AND MANNER THEY ARE INTENDED. <br />7. WHERE TOP OR SOLE PLATE ARE CUT FOR PIPES, A METAL TIE <br />MINIMUM 0.058 INCHES THICK AND 1-1/2" WIDE SHALL BE FASTENED <br />ACROSS THE OPENING WITH (6) 16D NAILS MINIMUM EACH SIDE. <br />8. FIELD CUTTING ENDS, NOTCHES AND DRILLED HOLES IN <br />PRESERVATIVE -TREATED WOOD SHALL BE TREATED IN THE FIELD IN <br />ACCORDANCE WITH AWPA MA4. <br />9. PROVIDE DOUBLE TOP PLATE WITH MINIMUM 48" LAP SPICES AND <br />(8) 16 LAP SPLICE NAILING. <br />10. BRACED WALL PANEL HOLD-DOWN HARDWARE SHOWN ON THE <br />APPROVED PLANS OR IN ACCORDANCE WITH CRC SECTION R602.10 <br />MUST BE SECURED IN PLACE PRIOR TO FOUNDATION INSPECTION. <br />CALIFORNIA ELECTRICAL CODE: <br />1. IN EVERY DWELLING UNIT, FIXED APPLIANCES SUCH AS FOOD WASTED <br />GRINDERS, DISHWASHER, WASHING MACHINES, DRYERS, LAUNDRY TRAY <br />LOCATION, BUILT-IN REGRIGERATORS OR FREEZERS, FURANCES, AC UNITS, <br />BUILT-IN HEATERS OR ANY OTHER FIXED APPLIANCE WITH A MOTOR OF 1/4" <br />H.P. OR LARGER SHALL BE ON A SEPARATE 20 AMP. BRANCH CIRCUIT <br />COMPLYING WITH CEC SECTION 422.10 <br />2. RECEPTACLES COMPLYING WITH CEC SECTION 210.52 SHALL BE LISTED AS <br />TAMPER-RESITANT FOR ALL 15 AND 20 AMPERE RECEPTACLES IN DWELLING <br />UNIT FAMILY, DINING, LIVING, PARLORS, LIBRARIES, DENS, BED ROOMS, <br />SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS <br />AND AREAS. <br />3. THE ENGINEER OF RECORD, ARCHITECT OR PLANS PREPARER SHALL <br />PROVIDE DETAILS TO THE CITY INSPECTOR, UPON REQUEST, SHOWING THE <br />LOCATION AND SIZE OF THE MAIN SERVICE PANEL (MSP AND THE SOURCE <br />OF POWER FOR THE APPROVED ADU. <br />4. RECEPTACLES COMPLYING WITH CEC SECTION 210.52 SHALL BE LISTED AS <br />TAMPER-RESITANT FOR ALL 15 AND 20 AMPERE RECEPTACLES IN DWELLING <br />UNIT FAMILY, DINING, LIVING, PARLORS, LIBRARIES, DENS, BED ROOMS, <br />SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS <br />AND AREAS. <br />5. A WORKLIGHT, SWITCH AND RECEPTACLE OUTLETS COMPLYING WITH CEC <br />SECTION 210.70(3) IS REQUIRED FOR ATTICS, UNDER FLOOR SPACES, UTILITY <br />ROOMS, AND BASEMENTS WHERE THESE SPACES ARE USED FOR STORAGE <br />OR CONTAIN EQUIPEMENT REQUIRING SERVICING. THE LIGHTING OUTLET <br />SHALL BE PROVIDED AT OR NEAR THE EQUIPMENT REQUIRING SERVICING. <br />CALIFORNIA ENERGY CODE: <br />1. RECESSED LIGHTS INTALLED IN AN INSULATED CEILING OR CAVITY ARE <br />REQUIRED T HAVE A ZERO CLEARANCE INSULATION COVER (IC), BE ASTM <br />E283 CERTIFIED THAT THEY ARE AIR TIGHT, AND SEALED WITH A GASKET <br />OR CAULK BETWEEN THE HOUSE AND THE CEILING. <br />2. OUTDOOR LIGHTING ATTACHED TO A BUILDING MUST BE HIGH EFFICACY, <br />OR CONTROLLED BY A MOTION SENSOR WITH AN INTEGRAL <br />PHOTO -CONTROL. <br />3. ALL NEW GLAZING SHALL BE INSTALLED WITH LABELS TO REMAIN IN <br />PLACE FOR INSPECTION. <br />4. ROOMS CONTAINING BATHTUBS, SHOWERS, SPAS, AND SIMILAR <br />BATHING FIXTURES SHALL BE MECHANICALLY VENTILATED. A MINIMUM <br />RATE OF 50CFM IS REQUIRED. UPON REQUEST FROM THE CITY INSPECTOR, <br />THE ENGINEER OF RECORD, ARCHITECT OR PLANS PREPARER SHALL <br />PROVIDE DETAILS FOR DUCTING SIZE AND LENGTHS TO MEET THE <br />MINIMUM REQUIREMENTS OF ASHRA STANDARD 62.2 AND MAXIMUM SOUND <br />RATING OR 3 SONE FOR INTERMITTENT OPERATION. <br />CALIFORNIA PLUMBING CODE: <br />1. ALL HOSE BIBS MUST BE PROTECTED BY ANTI SIPHO DEVICE <br />COMPLYING WITH CPC SEC TION 603. <br />2. ANTI -SCALDING OR THRMOSTATIC MIXING VALVES ARE REQUIRED AT <br />SHOWERS AND TUB/SHOWER COMBINATION. FOR PE <br />3.WATER HEATERS SHALL HAVE A TEMPERATURE AND PRESSURE RELIEF <br />VALVE COMPLYING WITH CPC SECTIONS 505.4 & 608.6. 1 HE POINT OF <br />DISCHARGE FOR RELIEF VALVE SHALL BE IN ACCORDAN E WITH CPC <br />SECTION 608.7. <br />4. WHRESHALL HAVE A VEDDOED CAT DTANTANOUS GAS LINE SIZED ERGASTER THE AP LIP= &sI D <br />SPECIFICATIONS. <br />Date: <br />5. WATER PIPING MATERIALS WITHIN A BUILDING SHALL E IN <br />ACCORDANCE WITH SEC. 604.1 OF THE CALIFORNIA PLU BING CODE. <br />PEX, CPVC AND OTHER PLASTIC WATER PIPING SYSTEM <br />INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF SEC. 604 OF <br />THE CPC, INSTALLATION STANDARDS OF APPENDIX I OF THE CPC AND <br />MANUFACTURERS RECOMMENDED INSTALLATION STANDARD. CPVC <br />WATER PIPING REQUIRES A CERTIFICATION OF COMPLIANCE AS <br />SPECIFIED IN SEC. 604.1.1(d) OF THE CPC PRIOR TO PERMIT ISSUANCE. <br />6. WATER HEATER CLOSET SHALL HAVE 15 TO ANY WALL OR <br />OBSTRUCTION ON EACH SIDE OF ITS CENTERLINE AND 24" CLEAR SAPCE <br />IN FRONT. (CPC 402.5) <br />7. PER SECTION 311.1 OF THE CALIFORNIA PLUMBING CODE, AN ADU <br />BUILDING SEWER SHALL BE SEPARATELY CONNECTED TO THE PUBLIC <br />SEWER, OR TRUNK SEWER (SEWER MAINTENANCE SADDLE PERMIT OR <br />SANITATION DISTRICT APPROVAL IN ADDITION TO AN ENCROACHMENT <br />PERMIT ARE REQUIRED.) HOWEVER, SINCE THE LOT MAY NOT BE <br />SUBDIVIDED IN A MANNER THAT THE ADU BECOMES A SINGLE - FAMILY <br />UNIT, THE BUILDING SEWER FROM THE ADU MAY CONNECT TO THE <br />BUILDING SEWER FROM THE EXISTING BUILDING AT A POINT 2 FEET <br />OUTSIDE OF THE EXISTING BUILDING. <br />18. ALL GROUNDING ELECRODES AS DESCRIBED IN CED 250.529(A) (7) <br />THAT ARE PRESENT AT EACH BUILDING OR STRUCTURE SERVED SHALL <br />BE BONDED TOGETHER TO FORM THE GROUNDING ELECTRODE SYSTEM. <br />IF MULTIPLE RODS, PIPE, OR PLATE ELECTRODES ARE INSTALLED TO <br />MEET THE REQUIREMENTS OF CED 250.53 (A) (3) THEY SHALL NOT BE <br />LESS THAN 6 FEET APART. <br />EGRESS <br />1.BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM <br />SHALL HAVE AT LEAST ONE OPENABLE EMERGENCY ESCAPE AND <br />RESCUE OPENING HAVING A MINIMUM NET CLEAR OPENING OF 5.7 <br />SQUARE FEET EXCEPT FOR GRADE FLOOR OPENINGS SHALL HAVE A <br />MINIMUM NET CLEAR OPENING OF 5 SQUARE FEET. THE MIN. NET <br />CLEAR OPENING HEIGHT SHALL BE 24 IN. WIDTH SHALL BE 20 IN. <br />MIN. , AND BOTTOM OF THE CLEAR OPENING SHALL BE NO <br />GREATER THAN 44 INCHES MEASURED FROM THE FLOOR. <br />LIGHTING <br />1. A MINIMUM OF FOUR BRANCH CIRCUITS SHALL BE IDENTIFIED <br />AND HAVE THEIR SOURCE OF SUPPLY COLLOCATED AT A SINGLE <br />PANELBOARD SUITABLE TO BE SUPPLIED BY THE ESS AT LEAST <br />ONE CIRCUIT SHALL BE LOCATED NEAR THE PRIMARY EGRESS AND <br />AT LEAST ONE CIRCUIT SHALL SUPPLY A SLEEPING ROOM <br />RECEPTACLE OUTLET. <br />A. ALL RESIDENTIAL OUTDOOR LIGHTING PERMANENTLY <br />MOUNTED TO THE RESIDENCE OR OTHER BUILDINGS ON THE <br />SAME LOT BE HIGH -EFFICACY AND MEET THE FOLLOWING <br />REQUIREMENTS (150(K) 3A CEC) <br />1. LIGHTS SHALL COMPLY WITH ONE OF THE TWO OPTIONS <br />BELOW: <br />I. CONTROLLED BY A PHOTOCELL AND MOTION SENSOR. <br />CONTROLS THAT <br />OVERRIDE TO ON SHALL NOT BE ALLOWED UNLESS <br />THE OVERRRIDE <br />AUTOMATICALLY REACTIVATES THE MOTION <br />SENSOR WITHIN 6 HOURS. <br />II. CONTROLLED BY (1) PHOTOCONTROL AND AUTOMATIC TIME SWITCH <br />CONTROL OR (2) ASTRONOMICAL TIME CLOCK OR (3) ENERGY MANAGEMENT <br />CONTROL SYSTEM MEETING THE REQUIREMENTS OF 150(K)3A. <br />note: written dimensions shall <br />take preference over scaled <br />dimensions and shall be rifled <br />0 e�enllbn�eshgns <br />prior to commencement of any <br />H <br />Cn <br />F_ <br />r- <br />§ <br />U <br />Q <br />ZQ <br />O <br />O <br />O <br />� <br />N <br />Q <br />N <br />>% <br />LO <br />~ <br />Z <br />W <br />��1 <br />V <br />o <br />a) <br />U) <br />LO <br />O <br />C <br />� <br />pQ <br />T- <br />r <br />.. <br />N <br />.O <br />Q <br />co <br />O <br />� <br />W <br />Z <br />0 <br />Z <br />a <br />J <br />Lu <br />W <br />IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII <br />� <br />z <br />VI <br />0 <br />J <br />Q <br />u <br />W <br />0 <br />u <br />C� <br />■ J <br />Q <br />H <br />Z <br />W <br />W <br />CV <br />co <br />r` <br />Q <br />Cr E <br />O ° <br />�L <br />JO � <br />QCyD E <br />U� 0-� <br />UJ I <br />z-t CD <br />OLO o <br />:�i^ <br />JQ0 E <br />Lu Cat .0) <br />� � <br />} aD <br />_M <br />OM <br />Q J_ <br />O Q <br />= W <br />O <br />CE <br />00 <br />r <br />00 <br />r <br />DATE <br />SCALE AS NOTED <br />DRAWN: SA <br />SHEET <br />04- <br />E <br />