Laserfiche WebLink
400 Sunrise Ave., Suite 270 <br />Roseville, CA 95661 <br />916.755.3571 / MiTek-US.com <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) <br />BCSI Building Component Safety Information <br />WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. <br />and available from the Structural Building Component Association (www.sbcscomponents.com) <br />0.2512 <br />=3x6 <br />=6x8 <br />=6x12 <br />=2x6 =4x12 <br />=2x6 =4x12 <br />=2x6 =6x8 =5x8 <br />=M18AHS 8x12 <br />=4x5 <br />=6x16 <br />=4x5 =2x6 <br />=4x8 <br />=4x5 <br />=4x5 =2x6 <br />=7x10 =3x10 <br />=10x16 <br />39 <br />21 <br />36 20 37 19 38 18 17 40 16 41 15 42 14 43 13 44 12 <br />2324 <br />11351034933832731302962854273262251 <br />22 <br />0-5-10 <br />34-8-0 <br />1-10-3 <br />14-2-9 <br />2-0-15 <br />16-3-9 <br />3-1-12 <br />27-6-4 <br />3-1-15 <br />30-8-3 <br />3-6-3 <br />34-2-6 <br />3-10-12 <br />20-2-5 <br />4-1-1 <br />8-3-5 <br />4-1-2 <br />12-4-6 <br />4-2-3 <br />24-4-8 <br />4-2-3 <br />4-2-3 <br />0-11-4 <br />34-8-0 <br />3-0-9 <br />33-8-12 <br />3-1-12 <br />27-6-4 <br />3-1-15 <br />30-8-3 <br />3-10-12 <br />20-2-5 <br />3-11-2 <br />16-3-9 <br />4-1-1 <br />8-3-5 <br />4-1-2 <br />12-4-6 <br />4-2-3 <br />24-4-8 <br />4-2-3 <br />4-2-3 <br />5-6-0 <br />2-6-11 <br />4-8-12 <br />0-9-4 <br />1-6-5 <br />1-6-5 <br />0-0-12 <br />1-7-1 <br />0-3-1 <br />1-10 <br />-2 <br />3-7-14 <br />5-6-0 <br />Scale = 1:66.4 <br />Plate Offsets (X, Y):[1:0-3-8,0-3-0], [3:0-4-11,0-2-0], [6:0-2-0,0-2-8], [7:0-3-4,0-3-0], [11:0-8-0,0-5-8], [17:0-6-0,0-6-4], [18:0-4-12,0-2-0] <br />Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP <br />TCLL (roof)20.0 Plate Grip DOL 1.25 TC 0.38 Vert(LL)-0.47 16-17 >870 360 MT20 220/195 <br />TCDL 14.0 Lumber DOL 1.25 BC 0.75 Vert(CT)-0.97 16-17 >422 240 M18AHS 169/162 <br />BCLL 0.0 *Rep Stress Incr NO WB 0.98 Horz(CT)0.08 24 n/a n/a <br />BCDL 7.0 Code IBC2021/TPI2014 Matrix-MSH Wind(LL)0.35 16-17 >999 240 Weight: 271 lb FT = 20% <br />LUMBER <br />TOP CHORD 2x8 DF SS G *Except* 6-7:2x4 DF No.2 G <br />BOT CHORD 2x8 DF SS G <br />WEBS 2x4 DF No.2 G or 2x4 DF Std G or 2x4 DF <br />Stud G *Except* 23-22:2x6 DF No.2 G, <br />20-1,18-3,13-11:2x4 DF No.2 G <br />OTHERS 2x6 DF 1800F 1.6E G or 2x6 DF SS G <br />BRACING <br />TOP CHORD Structural wood sheathing directly applied or <br />3-0-0 oc purlins, except end verticals. <br />BOT CHORD Rigid ceiling directly applied or 8-2-2 oc <br />bracing. <br />REACTIONS (lb/size)21=1605/0-5-8, 24=1596/0-5-8 <br />Max Horiz 21=-185 (LC 10) <br />Max Uplift 21=-76 (LC 9), 24=-121 (LC 9) <br />FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 <br />(lb) or less except when shown. <br />TOP CHORD 1-21=-1530/272, 1-25=-3080/504, <br />2-25=-3082/503, 2-26=-3080/501, <br />3-26=-3082/500, 3-27=-7753/1304, <br />4-27=-7755/1303, 4-5=-7752/1300, <br />5-28=-7753/1300, 6-28=-7754/1300, <br />6-29=-9096/1555, 29-30=-9102/1555, <br />30-31=-9105/1556, 7-31=-9107/1555, <br />7-32=-9221/1617, 8-32=-9225/1617, <br />8-33=-6427/1271, 9-33=-6428/1271, <br />9-34=-4073/930, 10-34=-4074/929, <br />10-35=-4071/942, 11-35=-4075/942, <br />12-24=-32/504, 11-24=-32/504 <br />BOT CHORD 20-37=-1016/5659, 19-37=-1016/5659, <br />19-38=-1016/5659, 18-38=-1016/5659, <br />18-39=-1465/9101, 17-39=-1465/9101, <br />17-40=-1448/9219, 16-40=-1448/9219, <br />16-41=-1336/8159, 15-41=-1336/8159, <br />15-42=-1341/8130, 14-42=-1341/8130, <br />14-43=-1106/6425, 13-43=-1106/6425, <br />13-44=-355/1205, 12-44=-355/1205 <br />WEBS 2-20=-451/95, 1-20=-558/3333, <br />3-20=-2808/493, 3-19=0/380, <br />3-18=-385/2278, 4-18=-459/94, <br />6-18=-1457/279, 6-17=-58/323, <br />7-16=-372/128, 8-16=-255/1126, 8-15=0/419, <br />8-14=-1905/364, 9-14=-118/837, <br />9-13=-2604/471, 11-13=-517/3025, <br />7-17=-506/320, 11-24=-1950/321 <br />NOTES <br />1)Wind: ASCE 7-16; Vult=96mph (3-second gust) <br />Vasd=76mph; TCDL=8.4psf; BCDL=4.2psf; h=25ft; Cat. <br />II; Exp C; Enclosed; MWFRS (envelope) exterior zone <br />and C-C Corner (3) 0-1-13 to 15-1-13, Exterior (2) <br />15-1-13 to 18-11-9, Corner (3) 18-11-9 to 33-11-9 zone; <br />cantilever left and right exposed ; end vertical left and <br />right exposed;C-C for members and forces & MWFRS <br />for reactions shown; Lumber DOL=1.60 plate grip <br />DOL=1.60 <br />2)Provide adequate drainage to prevent water ponding. <br />3)All plates are MT20 plates unless otherwise indicated. <br />4)This truss has been designed for a 10.0 psf bottom <br />chord live load nonconcurrent with any other live loads. <br />5)* This truss has been designed for a live load of 20.0psf <br />on the bottom chord in all areas where a rectangle <br />3-06-00 tall by 2-00-00 wide will fit between the bottom <br />chord and any other members. <br />6)A plate rating reduction of 20% has been applied for the <br />green lumber members. <br />7)Bearing at joint(s) 24 considers parallel to grain value <br />using ANSI/TPI 1 angle to grain formula. Building <br />designer should verify capacity of bearing surface. <br />8)Provide mechanical connection (by others) of truss to <br />bearing plate capable of withstanding 76 lb uplift at joint <br />21 and 121 lb uplift at joint 24. <br />9)This truss has been designed for a moving concentrated <br />load of 300.0lb live and 80.0lb dead located at all mid <br />panels and at all panel points along the Top Chord and <br />Bottom Chord, nonconcurrent with any other live loads. <br />10)Graphical purlin representation does not depict the size <br />or the orientation of the purlin along the top and/or <br />bottom chord. <br />11)Hanger(s) or other connection device(s) shall be <br />provided sufficient to support concentrated load(s) 133 <br />lb down and 18 lb up at 18-4-5, and 197 lb down and 27 <br />lb up at 20-1-15, and 197 lb down and 27 lb up at <br />16-9-13 on top chord. The design/selection of such <br />connection device(s) is the responsibility of others. <br />12)This truss is designed for a creep factor of 2.01, which is <br />used to calculate the Vert(CT) deflection per ANSI/TPI 1. <br />The building designer shall verify that this parameter fits <br />with the intended use of this component. <br />13)In the LOAD CASE(S) section, loads applied to the face <br />of the truss are noted as front (F) or back (B). <br />LOAD CASE(S) Standard <br />1)Dead + Roof Live (balanced): Lumber Increase=1.25, <br />Plate Increase=1.25 <br />Uniform Loads (lb/ft) <br />Vert: 1-11=-68, 12-21=-14 <br />Concentrated Loads (lb) <br />Vert: 7=-160 (F), 29=-160 (F), 30=-108 <br />Job Truss Truss Type Qty Ply M39558- TOMS JR SANTA ANA <br />R80031749AA08Roof Special 2 1M39885- TOMS JR Job Reference (optional) <br />Builders FirstSource (Perris, CA), Perris, CA - 92570,Run: 8.63 S Mar 9 2023 Print: 8.630 S Mar 9 2023 MiTek Industries, Inc. Wed Dec 27 13:34:40 Page: 1 <br />ID:khQzV5pn_07oTNMVNFVsM0yEC6c-sqgU4py?dhSjqSkB0LyC2?0MjjvBFX0Sk17?5Vy4kUT <br />December 27,2023 <br />1430 E Edinger Ave <br />3/27/2025