Laserfiche WebLink
400 Sunrise Ave., Suite 270 <br />Roseville, CA 95661 <br />916.755.3571 / MiTek-US.com <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) <br />BCSI Building Component Safety Information <br />WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. <br />and available from the Structural Building Component Association (www.sbcscomponents.com) <br />0.2512 <br />0.25 <br />12 <br />=3x4 <br />=5x6 <br />=3x4 <br />=4x6 <br />=2x6 <br />=2x6 <br />=3x4 <br />=3x4 <br />=3x4 <br />=6x16 <br />=4x5 <br />=6x8 <br />13 <br />12 <br />20 <br />11 <br />10 <br />21 9 22 <br />8 <br />14 <br />15 <br />1 2 16 3 <br />4 5 17 18 6 19 7 <br />0-7-12 <br />3-8-5 <br />0-5-8 <br />-0-5-8 <br />3-0-8 <br />3-0-8 <br />5-6-12 <br />9-3-0 <br />6-4-0 <br />15 -7-0 <br />0-3-12 <br />0-3-12 <br />0-6-0 <br />3-8-5 <br />0-1-0 <br />3-9-4 <br />0-7-8 <br />15-7-0 <br />2-10-8 <br />3-2-5 <br />5-5-12 <br />9-3-0 <br />5-8-8 <br />14-11-8 <br />2-7-4 <br />1-2-2 <br />1-10 <br />-0 <br />0-3-9 <br />1-4-6 <br />0-9-4 <br />1-2-14 <br />1-2-14 <br />1-4-6 <br />2-7-4 <br />Scale = 1:41.2 <br />Plate Offsets (X, Y):[7:0-5-4,0-3-4], [8:Edge,0-3-9] <br />Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP <br />TCLL (roof)20.0 Plate Grip DOL 1.25 TC 0.63 Vert(LL)-0.13 8-9 >999 360 MT20 220/195 <br />TCDL 14.0 Lumber DOL 1.25 BC 0.58 Vert(CT)-0.18 8-9 >769 240 <br />BCLL 0.0 *Rep Stress Incr NO WB 0.56 Horz(CT)0.01 15 n/a n/a <br />BCDL 7.0 Code IBC2021/TPI2014 Matrix-MSH Wind(LL)0.02 9-10 >999 240 Weight: 78 lb FT = 20% <br />LUMBER <br />TOP CHORD 2x4 DF No.2 G <br />BOT CHORD 2x4 DF No.2 G <br />WEBS 2x4 DF No.2 G or 2x4 DF Std G or 2x4 DF <br />Stud G <br />OTHERS 2x8 DF No.2 G <br />BRACING <br />TOP CHORD Structural wood sheathing directly applied or <br />6-0-0 oc purlins, except end verticals, and <br />2-0-0 oc purlins (5-9-15 max.): 3-11, 4-7. <br />BOT CHORD Rigid ceiling directly applied or 6-0-0 oc <br />bracing. <br />REACTIONS (size)1=0-5-8, 10=0-5-8, 15=0-5-8 <br />Max Horiz 1=-47 (LC 10) <br />Max Uplift 1=-6 (LC 12), 10=-51 (LC 8), <br />15=-20 (LC 9) <br />Max Grav 1=436 (LC 29), 10=1136 (LC 1), <br />15=584 (LC 50) <br />FORCES (lb) - Maximum Compression/Maximum <br />Tension <br />TOP CHORD 2-12=-1/435, 1-2=-69/62, 2-3=-77/144, <br />3-11=-175/502, 3-4=-242/647, 4-5=-19/76, <br />5-6=-19/76, 6-7=-816/262, 8-14=0/420, <br />7-14=0/420 <br />BOT CHORD 12-13=0/0, 11-12=-29/213, 10-11=-76/35, <br />9-10=-272/816, 8-9=-66/222 <br />WEBS 2-11=-242/83, 6-9=-217/163, 7-9=-223/749, <br />5-10=-1022/415, 6-10=-915/295, <br />7-15=-621/177 <br />NOTES <br />1)Unbalanced roof live loads have been considered for <br />this design. <br />2)Wind: ASCE 7-16; Vult=96mph (3-second gust) <br />Vasd=76mph; TCDL=8.4psf; BCDL=4.2psf; h=25ft; Cat. <br />II; Exp C; Enclosed; MWFRS (envelope) exterior zone <br />and C-C Corner (3) 0-2-12 to 15-3-4 zone; cantilever left <br />and right exposed ; end vertical left and right <br />exposed;C-C for members and forces & MWFRS for <br />reactions shown; Lumber DOL=1.60 plate grip <br />DOL=1.60 <br />3)Provide adequate drainage to prevent water ponding. <br />4)This truss has been designed for a 10.0 psf bottom <br />chord live load nonconcurrent with any other live loads. <br />5)* This truss has been designed for a live load of 20.0psf <br />on the bottom chord in all areas where a rectangle <br />3-06-00 tall by 2-00-00 wide will fit between the bottom <br />chord and any other members. <br />6)A plate rating reduction of 20% has been applied for the <br />green lumber members. <br />7)Bearings are assumed to be: Joint 1 DF No.2 crushing <br />capacity of 625 psi, Joint 10 DF No.2 crushing capacity <br />of 625 psi, Joint 15 DF No.2 crushing capacity of 625 <br />psi. <br />8)Bearing at joint(s) 15 considers parallel to grain value <br />using ANSI/TPI 1 angle to grain formula. Building <br />designer should verify capacity of bearing surface. <br />9)Provide mechanical connection (by others) of truss to <br />bearing plate capable of withstanding 6 lb uplift at joint <br />1, 51 lb uplift at joint 10 and 20 lb uplift at joint 15. <br />10)Beveled plate or shim required to provide full bearing <br />surface with truss chord at joint(s) 1. <br />11)This truss has been designed for a moving concentrated <br />load of 300.0lb live and 80.0lb dead located at all mid <br />panels and at all panel points along the Top Chord and <br />Bottom Chord, nonconcurrent with any other live loads. <br />12)Graphical purlin representation does not depict the size <br />or the orientation of the purlin along the top and/or <br />bottom chord. <br />13)Hanger(s) or other connection device(s) shall be <br />provided sufficient to support concentrated load(s) 207 <br />lb down and 71 lb up at 3-7-13, and 207 lb down and 71 <br />lb up at 6-0-4 on top chord. The design/selection of <br />such connection device(s) is the responsibility of others. <br />14)This truss is designed for a creep factor of 2.01, which is <br />used to calculate the Vert(CT) deflection per ANSI/TPI 1. <br />The building designer shall verify that this parameter fits <br />with the intended use of this component. <br />LOAD CASE(S) Standard <br />1)Dead + Roof Live (balanced): Lumber Increase=1.25, <br />Plate Increase=1.25 <br />Uniform Loads (lb/ft) <br />Vert: 1-2=-68, 2-3=-68, 4-7=-68, 10-13=-30, <br />8-10=-14 <br />Concentrated Loads (lb) <br />Vert: 3=-195, 17=-195 <br />Job Truss Truss Type Qty Ply M39558- TOMS JR SANTA ANA <br />R80031765AC08Half Hip 1 1M39885- TOMS JR Job Reference (optional) <br />Builders FirstSource (Perris, CA), Perris, CA - 92570,Run: 8.63 S Nov 1 2023 Print: 8.630 S Nov 1 2023 MiTek Industries, Inc. Wed Dec 27 09:55:41 Page: 1 <br />ID:IE6A3y2UwIpcU?s?hDDOslyEZ_R-RfC?PsB70Hq3NSgPqnL8w3uITXbGKWrCDoi7J4zJC?f <br />December 27,2023 <br />1430 E Edinger Ave <br />3/27/2025