Laserfiche WebLink
400 Sunrise Ave., Suite 270 <br />Roseville, CA 95661 <br />916.755.3571 / MiTek-US.com <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) <br />BCSI Building Component Safety Information <br />WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. <br />and available from the Structural Building Component Association (www.sbcscomponents.com) <br />0.2512 <br />=2x6 <br />=4x6 <br />=5x10 <br />=6x16 <br />=4x12 <br />=M18AHS 8x12 <br />=5x8 <br />=1.5x4 <br />=3x4 <br />=3x4 <br />=3x4 <br />=3x6 <br />=3x4 <br />14 10 26 9 27 8 28 <br />7 <br />23 13 <br />12 <br />25 11 <br />24 <br />1 15 2 <br />3 16 17 4 18 19 20 5 21 22 6 <br />3-5-12 <br />6-11-12 <br />3-6-0 <br />3-6-0 <br />4-5-8 <br />11-5-4 <br />4-7-4 <br />16-0-8 <br />0-0-6 <br />4-0-0 <br />0-1-12 <br />6-11-12 <br />0-5-10 <br />3-11-10 <br />0-9-15 <br />4-9-15 <br />2-0-1 <br />6-10 -0 <br />3-6-0 <br />3-6-0 <br />4-5-8 <br />11-5-4 <br />4-7-4 <br />16-0-8 <br />2-5-7 <br />1-2-0 2-5-7 <br />0-7-4 <br />1-2-9 <br />0-7-4 <br />0-7-4 0-7-10 <br />1-2-14 <br />1-2-9 <br />2-5-7 <br />Scale = 1:37.8 <br />Plate Offsets (X, Y):[2:0-10-0,Edge], [3:0-3-8,0-2-0], [6:Edge,0-1-8], [12:0-3-8,0-5-13] <br />Loading (psf)Spacing 1-7-3 CSI DEFL in (loc)l/defl L/d PLATES GRIP <br />TCLL (roof)20.0 Plate Grip DOL 1.25 TC 0.55 Vert(LL)-0.08 8-9 >999 360 MT20 220/195 <br />TCDL 38.0 Lumber DOL 1.25 BC 0.55 Vert(CT)-0.15 8-9 >957 240 M18AHS 169/162 <br />BCLL 0.0 *Rep Stress Incr NO WB 0.66 Horz(CT)0.02 7 n/a n/a <br />BCDL 7.0 Code IBC2021/TPI2014 Matrix-MSH Wind(LL)0.02 8-9 >999 240 Weight: 86 lb FT = 20% <br />LUMBER <br />TOP CHORD 2x4 DF 1800F 1.6E G or 2x4 DF No.1&Btr G <br />*Except* 3-6:2x4 DF No.2 G <br />BOT CHORD 2x4 DF 1800F 1.6E G or 2x4 DF No.1&Btr G <br />*Except* 2-11:2x6 DF No.2 G, 10-7:2x4 DF <br />No.2 G <br />WEBS 2x4 DF No.2 G or 2x4 DF Std G or 2x4 DF <br />Stud G *Except* 14-1,3-2:2x6 DF No.2 G, <br />13-3:2x6 DF 1800F 1.6E G or 2x6 DF SS G <br />BRACING <br />TOP CHORD Structural wood sheathing directly applied or <br />6-0-0 oc purlins, except end verticals, and <br />2-0-0 oc purlins (4-11-2 max.): 3-6. <br />BOT CHORD Rigid ceiling directly applied or 6-0-0 oc <br />bracing. <br />REACTIONS (size)2=0-5-8, 7=0-5-8 <br />Max Horiz 2=56 (LC 9) <br />Max Uplift 2=-79 (LC 8), 7=-24 (LC 9) <br />Max Grav 2=1572 (LC 25), 7=898 (LC 46) <br />FORCES (lb) - Maximum Compression/Maximum <br />Tension <br />TOP CHORD 1-14=-55/400, 1-2=-344/1813, <br />2-13=-139/517, 2-3=-772/173, <br />3-4=-1081/138, 4-5=-1213/216, 5-6=-80/31, <br />6-7=-537/71 <br />BOT CHORD 13-14=-99/86, 2-12=-956/227, <br />11-12=-1114/303, 10-12=-8/99, 9-10=-89/701, <br />8-9=-121/959, 7-8=-209/1213 <br />WEBS 3-11=-371/1352, 5-7=-1308/207, <br />5-8=-158/221, 1-13=-1748/361, <br />9-11=-93/227, 4-11=-756/215, 4-8=-97/493 <br />NOTES <br />1)Wind: ASCE 7-16; Vult=96mph (3-second gust) <br />Vasd=76mph; TCDL=8.4psf; BCDL=4.2psf; h=25ft; Cat. <br />II; Exp C; Enclosed; MWFRS (envelope) exterior zone <br />and C-C Corner (3) 0-2-13 to 15-10-12 zone; cantilever <br />left and right exposed ; end vertical left and right <br />exposed;C-C for members and forces & MWFRS for <br />reactions shown; Lumber DOL=1.60 plate grip <br />DOL=1.60 <br />2)Provide adequate drainage to prevent water ponding. <br />3)All plates are MT20 plates unless otherwise indicated. <br />4)This truss has been designed for a 10.0 psf bottom <br />chord live load nonconcurrent with any other live loads. <br />5)* This truss has been designed for a live load of 20.0psf <br />on the bottom chord in all areas where a rectangle <br />3-06-00 tall by 2-00-00 wide will fit between the bottom <br />chord and any other members. <br />6)A plate rating reduction of 20% has been applied for the <br />green lumber members. <br />7)Bearings are assumed to be: Joint 2 DF No.2 crushing <br />capacity of 625 psi, Joint 7 DF No.2 crushing capacity of <br />625 psi. <br />8)Provide mechanical connection (by others) of truss to <br />bearing plate capable of withstanding 79 lb uplift at joint <br />2 and 24 lb uplift at joint 7. <br />9)This truss has been designed for a moving concentrated <br />load of 300.0lb live and 80.0lb dead located at all mid <br />panels and at all panel points along the Top Chord and <br />Bottom Chord, nonconcurrent with any other live loads. <br />10)Graphical purlin representation does not depict the size <br />or the orientation of the purlin along the top and/or <br />bottom chord. <br />11)Hanger(s) or other connection device(s) shall be <br />provided sufficient to support concentrated load(s) 202 <br />lb down and 44 lb up at 3-11-10, 202 lb down and 44 lb <br />up at 6-0-3, 112 lb down and 24 lb up at 7-2-3, and 78 <br />lb down and 17 lb up at 14-10-10, and 78 lb down and <br />17 lb up at 10-5-10 on top chord. The design/selection <br />of such connection device(s) is the responsibility of <br />others. <br />12)This truss is designed for a creep factor of 2.01, which is <br />used to calculate the Vert(CT) deflection per ANSI/TPI 1. <br />The building designer shall verify that this parameter fits <br />with the intended use of this component. <br />13)In the LOAD CASE(S) section, loads applied to the face <br />of the truss are noted as front (F) or back (B). <br />LOAD CASE(S) Standard <br />1)Dead + Roof Live (balanced): Lumber Increase=1.25, <br />Plate Increase=1.25 <br />Uniform Loads (lb/ft) <br />Vert: 1-2=-93, 3-6=-93, 13-14=-27, 2-12=-11, <br />7-10=-11 <br />Concentrated Loads (lb) <br />Vert: 2=-195, 4=-108, 17=-195, 20=-76 (F), 22=-76 <br />Job Truss Truss Type Qty Ply M39558- TOMS JR SANTA ANA <br />R80031770AC13Half Hip 1 1M39885- TOMS JR Job Reference (optional) <br />Builders FirstSource (Perris, CA), Perris, CA - 92570,Run: 8.63 S Nov 1 2023 Print: 8.630 S Nov 1 2023 MiTek Industries, Inc. Wed Dec 27 09:55:44 Page: 1 <br />ID:kKOGfExGQL4yOT88ri0INoyER3v-RfC?PsB70Hq3NSgPqnL8w3uITXbGKWrCDoi7J4zJC?f <br />December 27,2023 <br />1430 E Edinger Ave <br />3/27/2025