Laserfiche WebLink
400 Sunrise Ave., Suite 270 <br />Roseville, CA 95661 <br />916.755.3571 / MiTek-US.com <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) <br />BCSI Building Component Safety Information <br />WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. <br />and available from the Structural Building Component Association (www.sbcscomponents.com) <br />0.1812 <br />=1.5x4 <br />=M18AHS 5x12 <br />=2x6 <br />=7x10 <br />=4x6 <br />=6x16 <br />=1.5x4 <br />=6x8 <br />7 <br />15 <br />16 <br />6 <br />17 <br />511 <br />9 10 <br />12 <br />1 13 2 <br />3 14 4 <br />8 <br />0-5-10 <br />4-11-10 <br />2-0-7 <br />7-0-1 <br />4-6-0 <br />4-6-0 <br />0-5-10 <br />0-5-10 <br />0-9-8 <br />7-0-1 <br />1-5-13 <br />6-2-9 <br />4-3-2 <br />4-8-12 <br />5-6-0 <br />0-5-13 <br />1-3-9 <br />0-8-9 <br />0-9-40-6-10 <br />1-3-14 0-8-9 <br />2-0-7 <br />3-5-9 <br />5-6-0 <br />Scale = 1:42.8 <br />Plate Offsets (X, Y):[1:0-3-4,0-3-4], [3:0-3-0,Edge], [4:0-3-4,0-3-4] <br />Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP <br />TCLL (roof)20.0 Plate Grip DOL 1.25 TC 0.68 Vert(LL)-0.05 6-7 >999 360 MT20 220/195 <br />TCDL 14.0 Lumber DOL 1.25 BC 0.44 Vert(CT)-0.08 6-7 >705 240 M18AHS 169/162 <br />BCLL 0.0 *Rep Stress Incr NO WB 0.16 Horz(CT)-0.01 12 n/a n/a <br />BCDL 7.0 Code IBC2021/TPI2014 Matrix-MP Wind(LL)0.01 6-7 >999 240 Weight: 43 lb FT = 20% <br />LUMBER <br />TOP CHORD 2x4 DF No.2 G <br />BOT CHORD 2x4 DF No.2 G <br />WEBS 2x4 DF No.2 G or 2x4 DF Std G or 2x4 DF <br />Stud G *Except* 6-8:2x6 DF No.2 G <br />OTHERS 2x6 DF No.2 G *Except* 10-4:2x10 DF No.2 <br />G <br />BRACING <br />TOP CHORD Structural wood sheathing directly applied or <br />6-0-0 oc purlins, except end verticals. <br />Except: <br />10-0-0 oc bracing: 3-8 <br />BOT CHORD Rigid ceiling directly applied or 6-0-0 oc <br />bracing. <br />REACTIONS (size)6=0-5-8, 11=0-3-8, 12=0-7-12 <br />Max Horiz 11=-155 (LC 10) <br />Max Uplift 6=-225 (LC 8), 11=-5 (LC 12), <br />12=-226 (LC 11) <br />Max Grav 6=562 (LC 27), 11=432 (LC 25), <br />12=243 (LC 30) <br />FORCES (lb) - Maximum Compression/Maximum <br />Tension <br />TOP CHORD 7-9=-2/417, 1-9=-2/417, 1-2=-119/146, <br />2-6=-438/315, 2-3=-214/204, 3-8=0/0, <br />3-4=-495/515, 5-10=-209/353, 4-10=-209/353 <br />BOT CHORD 6-7=-262/410, 5-6=-243/224 <br />WEBS 1-6=-374/244, 4-6=-495/503, 1-11=-971/388, <br />4-12=-658/723 <br />NOTES <br />1)Wind: ASCE 7-16; Vult=96mph (3-second gust) <br />Vasd=76mph; TCDL=8.4psf; BCDL=4.2psf; h=25ft; Cat. <br />II; Exp C; Enclosed; MWFRS (envelope) exterior zone <br />and C-C Corner (3) 0-7-7 to 6-0-13 zone; cantilever left <br />and right exposed ; end vertical left and right <br />exposed;C-C for members and forces & MWFRS for <br />reactions shown; Lumber DOL=1.60 plate grip <br />DOL=1.60 <br />2)Provide adequate drainage to prevent water ponding. <br />3)All plates are MT20 plates unless otherwise indicated. <br />4)This truss has been designed for a 10.0 psf bottom <br />chord live load nonconcurrent with any other live loads. <br />5)* This truss has been designed for a live load of 20.0psf <br />on the bottom chord in all areas where a rectangle <br />3-06-00 tall by 2-00-00 wide will fit between the bottom <br />chord and any other members. <br />6)A plate rating reduction of 20% has been applied for the <br />green lumber members. <br />7)Bearings are assumed to be: Joint 11 DF No.2 crushing <br />capacity of 625 psi, Joint 6 DF No.2 crushing capacity of <br />625 psi, Joint 12 DF No.2 crushing capacity of 625 psi. <br />8)Bearing at joint(s) 11, 12 considers parallel to grain <br />value using ANSI/TPI 1 angle to grain formula. Building <br />designer should verify capacity of bearing surface. <br />9)Provide mechanical connection (by others) of truss to <br />bearing plate capable of withstanding 225 lb uplift at <br />joint 6, 5 lb uplift at joint 11 and 226 lb uplift at joint 12. <br />10)This truss has been designed for a moving concentrated <br />load of 300.0lb live and 80.0lb dead located at all mid <br />panels and at all panel points along the Top Chord and <br />Bottom Chord, nonconcurrent with any other live loads. <br />11)Graphical purlin representation does not depict the size <br />or the orientation of the purlin along the top and/or <br />bottom chord. <br />12)This truss is designed for a creep factor of 2.01, which is <br />used to calculate the Vert(CT) deflection per ANSI/TPI 1. <br />The building designer shall verify that this parameter fits <br />with the intended use of this component. <br />LOAD CASE(S) Standard <br />1)Dead + Roof Live (balanced): Lumber Increase=1.25, <br />Plate Increase=1.25 <br />Uniform Loads (lb/ft) <br />Vert: 1-2=-68, 3-4=-68, 7-16=-30, 5-16=-14 <br />Job Truss Truss Type Qty Ply M39558- TOMS JR SANTA ANA <br />R80031783AD03Roof Special 1 1M39885- TOMS JR Job Reference (optional) <br />Builders FirstSource (Perris, CA), Perris, CA - 92570,Run: 8.63 S Nov 1 2023 Print: 8.630 S Nov 1 2023 MiTek Industries, Inc. Wed Dec 27 09:55:50 Page: 1 <br />ID:kWr0WjwEb7ZC3rCnzmtuc2yEX3x-RfC?PsB70Hq3NSgPqnL8w3uITXbGKWrCDoi7J4zJC?f <br />December 27,2023 <br />1430 E Edinger Ave <br />3/27/2025