Laserfiche WebLink
11' - 3" <br />4' <br /> <br />- <br /> <br />0 <br />" <br />5' <br /> <br />- <br /> <br />0 <br />" <br />WINDOW "A" TYPE <br />WINDOW "B" <br />TYPE <br />5' - 7 1/2"5' - 7 1/2" <br />TEMP GLASS TEMP GLASS <br />PLAN VIEW <br />1' <br /> <br />- <br /> <br />0 <br />" <br />8'-0" PER MANUF <br />36" A.F.F. S.S. SHELF <br />BUTT JOINT CORNER GLAZING <br />3' <br /> <br />- <br /> <br />0 <br />" <br />8'-0" PER MANUF <br />6' <br /> <br />- <br /> <br />0 <br />" <br />3' <br /> <br />- <br /> <br />0 <br />" <br />PER MANUFACTURER <br />TEMP <br />GLASS <br />TEMPERED GLASS <br />w/ Self-Closing Mechanism <br />TEMP <br />GLASS <br />SIDE VIEW <br />TEMP GLASS TEMP GLASS <br />WINDOW "D" TYPE <br />4' <br /> <br />- <br /> <br />0 <br />" <br />5' <br /> <br />- <br /> <br />0 <br />" <br />TEMP GLASS <br />22' - 0" <br />WINDOW "E" TYPE <br />9' <br /> <br />- <br /> <br />0 <br />" <br />6' - 6" <br />GLASS DOOR <br />36" WIDE <br />TEMP GLASS <br />TEMP GLASS <br />WINDOW "F" TYPE <br />6' - 5" <br />TEMP GLASS <br />TEMP GLASSTEMP GLASSTEMP GLASS <br />7' - 2 1/2"7' - 1"7' - 8 1/2" <br />WINDOW "G" TYPE <br />9' <br /> <br />- <br /> <br />0 <br />" <br />3' - 8 1/2"9' - 0"9' - 0" <br />21' - 8 1/2" <br />TEMP GLASS <br />TEMP GLASS <br />TEMP GLASS <br />TEMP GLASS <br />TEMP GLASS <br />TEMP GLASS <br />WINDOW "H" TYPE <br />6' - 0" <br />7' <br /> <br />- <br /> <br />0 <br />" <br />2' <br /> <br />- <br /> <br />0 <br />" <br />TEMP <br />GLASS <br />7' <br /> <br />- <br /> <br />0 <br />" <br />3' - 6" <br />7' <br /> <br />- <br /> <br />0 <br />" <br />3' - 0" <br />2 <br />3 <br />5 <br />8 <br />6 <br />1 <br />4 <br />7 <br />9 <br />DOORS #7 & #9 AT <br />ELECTRICAL ROOM SHALL <br />BE STEEL WITH LOUVERS <br />2'-6" WIDE DOUBLE DOOR <br />WINDOW "C" <br />TYPE <br />2' <br /> <br />- <br /> <br />1 <br />0 <br />" <br />6' <br /> <br />- <br /> <br />2 <br />" <br />9' <br /> <br />- <br /> <br />0 <br />" <br />4' - 7" <br />8' <br /> <br />- <br /> <br />0 <br />" <br />5'-0" MTL DOOR <br />9 <br />7' <br /> <br />- <br /> <br />6 <br />" <br />7' <br /> <br />- <br /> <br />6 <br />" <br />Tempered Glass <br />w/ Self-Closing Mechanism <br />9' <br /> <br />- <br /> <br />0 <br />" <br />THRESHOLD <br />DETAIL 6/A-003 <br />5/A-003 <br />THRESHOLD <br />DETAIL 6/A-003 <br />5/A-003 <br />THRESHOLD <br />DETAIL 6/A-003 <br />5/A-003 <br />THRESHOLD <br />DETAIL 6/A-003 <br />5/A-003 <br />THRESHOLD <br />DETAIL 6/A-003 <br />5/A-003 <br />GENERAL WINDOW NOTES: <br />1. ALL WINDOW ROUGH OPENINGS (R.O.) SHOULD BE BASED ON <br />MANUFACTURER'S ORDERED SIZES, SPECIFICATIONS, RECOMMENDATIONS AND <br />DETAILS. <br />2. ROUGH FRAMING SUBCONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL <br />FRAMING, NAILERS AND FILLERS AS SHOWN ON DOOR DETAILS AND AS MAY <br />OTHERWISE BE REQUIRED FOR PROPER INSTALLATION OF ALL WINDOWS <br />REFER TO DETAILS. <br />3. ALL WINDOW DETAILS SHOULD MEET OR EXCEED DETAILS AND <br />SPECIFICATIONS OR AN OWNER AND ARCHITECT APPROVED EQUAL <br />SUBSTITUTE. <br />4. SHOP DRAWINGS OF ALL WINDOW TYPES MUST BE SUBMITTED TO THE <br />ARCHITECT FOR APPROVAL PRIOR TO FABRICATION. <br />5. REFER TO GENERAL NOTES FOR TYPICAL REQUIREMENTS APPLICABLE TO <br />WINDOWS <br />6. ALL WINDOWS TO BE INSTALLED IN STRICT ACCORDANCE WITH <br />MANUFACURER'S SPECIFICATIONS AND RECOMMENDATIONS TO INSURE <br />PRODUCT WARRANTY <br />7. WINDOW GLAZING TO BE DUAL GLAZING. <br />8. NOT USED <br />9. ALL EXTERIOR JAMBS TO BE BACK-PRIMED PRIOR TO INSTALLATION. <br />10. REFER TO THE ENERGY CALCS REPORT (T24) FOR REQUIRED 'U' & SHGC <br />VALUES. <br />11. SEE EXTERIOR ELEVATIONS FOR DEMARKATION OF DIRECTION OF SWING <br />ON ALL WINDOWS. <br />12. EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE EXTERIOR DOOR OR <br />WINDOW OPEN DIRECTLY INTO A YARD OR EXIT COURT FOR EMERGENCY <br />EGRESS. WINDOWS MUST PROVIDE THE FOLLOWING SITUATION: MINIMUM 5.7 <br />SQUARE FEET OF OPENABLE AREA CLEAR, MINIMUM CLEAR WIDTH OF 20", <br />MINIMUM CLEAR HEIGHT OF 24" AND A FINISH SILL HEIGHT NOT MORE THAN 44" <br />ABOVE FINISH FLOOR. (PER CBC 2022) <br />13. ALL GLAZING IN HAZARDOUS LOCATIONS MUST BE IDENTIFIED BY A LABEL <br />(PERMANENT IF TEMPERED) AS SAFTEY GLAZING: (PER CBC 2022). <br />A. GLAZING IN ALL DOORS <br />B. GLAZING IN BATH AND SHOWER ENCLOSURES <br />C. ALL GLAZING WITHIN 24" ARC OF THE DOOR EDGE <br />D. PANELS OVER 9 SQ. FT. IN AREA HAVING THE LOWEST EDGE LESS THAN <br />18" ABOVE THE FINISH FLOOR AND HAVING A TOP EDGE GREATER THAN 36" <br />ABOVE THE FLOOR <br />14. ANY GLASS AREA 9 SQUARE FEET OR LARGER IN SIZE TO BE SAFTEY GLASS. <br />GENERAL DOOR NOTES: <br />1. ALL SCHEMATIC DOOR TYPES ARE NOT TO SCALE. REFER TO ABOVE SCHEDULE <br />FOR DIMENSIONS. AND FIELD VERIFY EXISTING DEMOLISHED DOORS TO BE <br />REPLACED. <br />2. ALL EXTERIOR DOORS TO BE DELIVERED TO JOB SITE AS COMPLETE UNITS. <br />3. ALL DOOR AND WINDOW HARDWARE TO BE ON AN ALLOWANCE OWNER / INTERIOR <br />DESIGNER SELECTION. <br />4. REFER TO CF-1R FORM IN TITLE-24 ENERGY CALCULATIONS FOR REQUIRED 'U' <br />VALUES. <br />5. DOOR SAMPLE TO BE APPROVED BY OWNER AND ARCHITECT BEFORE PLACING <br />DOOR ORDER. <br />6. ALL DOORS TO BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S <br />SPECIFICATIONS AND RECOMMENDATIONS. <br />7. ROUGH FRAMING SUBCONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL <br />FRAMING, NAILERS AND FILLERS AS SHOWN ON DOOR DETAILS AND AS MAY <br />OTHERWISE BE REQUIRED FOR PROPER INSTALLATION OF ALL DOORS. INCLUDING <br />HEIGHTS OF HEADERS / BEAMS SUPPORTING DOORS & HARDWARE. <br />SUBCONTRACTOR SHALL COORDINATE WITH MANUFACTURER FOR DOOR <br />CLEARANCES & INSTALLATION. <br />8. GARAGE DOORS WITH ELECTRIC GARAGE DOOR OPENERS TO HAVE ELECTRIC EYE <br />SAFETY DEVICE MOUNTED AT HEIGHT REQUIRED BY MANUFACTURER AND LOCAL <br />GOVERNING BODY. <br />9. ANY GLASS AREA 9 SQUARE FEET OR LARGER IN SIZE TO BE TEMPERED. <br />TERMPERED GLASS IN HAZARDOUS LOCATIONS PER U.B.C. SEC 2406.4 <br />A. INGRESS AND EGRESS DOORS <br />B. PANELS IN SLIDING OR SWINGING DOORS OTHER THAN WARDROBE DOORS. <br />C. DOORS AND ENCLOSURES FOR HOT TUB, BATHRUB, SHOWERS (ALSO GLAZING IN <br />WALL ENCLOSING THESE COMPARTMENTS WITHIN 5' OF STANDING SURFACE) <br />D. IF WITHIN 2 FT. OF VERTICAL EDGE OF CLOSED DOOR AND WITHIN 5 FT. OF <br />STANDING SURFACE <br />E. IN WALL ENCLOSING STAIRWAY LANDING <br />10. SAFTEY GLASS IS REQUIRED AT WARDROBE DOOR. CBC 2022 <br />11. PROVIDE DOOR STOPS WHEREVER NECESSARY. <br />12. FINAL FINISH SELECTION FOR DOORS BY OWNER, ARCHITECT, AND INTERIOR <br />DESIGNER. <br />NOTE: NOT ALL GENERAL DOOR & WINDOWS NOTE(S) MAY APPLY, CONTACT <br />ARCHITECT FOR CLARRIFICATIONS. <br />Safety Glazing PER CBC 2022 & (R308.4/CBC 2406) <br />2406.4 Hazardous Locations. The following shall be considered specific hazardous locations for the <br />purposes of glazing: <br />1. Glazing in ingress and egress doors except jalousies. <br />2. Glazing in fixed and sliding panels of sliding door assemblies and panels in swinging doors other than <br />wardrobe doors. <br />3. Glazing in storm doors. <br />4. Glazing in all unframed swinging doors. <br />5. Glazing in doors and enclosures for hot tubs, whirlpools, saunas, steam rooms, bathtubs and <br />showers. Glazing in any portion of a building wall enclosing these compartments where the bottom <br />exposed edge of the glazing is less than 60 inches (1525 mm) above a standing surface and drain inlet. <br />6. Glazing in fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing <br />is within a 24-inch (610 mm) arc of either vertical edge of the door in a closed position and where the <br />bottom exposed edge of the glazing is less than 60 inches (1525 mm) above the walking surface. <br />7. Glazing in an individual fixed or operable panel, other than those locations described in Items 5 and 6 <br />above, that meets all of the following conditions: <br />7.1 Exposed area of an individual pane greater than 9 square feet (0.84 ). <br />7.2 Exposed bottom edge less than 18 inches (457 mm) above the floor. <br />7.3 Exposed top edge greater than 36 inches (914 mm) above the floor. <br />7.4 One or more walking surfaces within 36 inches (914 mm) horizontally of the plane of the <br />glazing. <br />8. Glazing in railings regardless of height above a walking surface. Included are structural baluster <br />panels and nonstructural in-fill panels. <br />EXCEPTION: The following products and applications are exempt from the requirements for hazardous <br />locations as listed in Items 1 through 8 above: <br />1. Glazing in Item 6 when there is an intervening wall or other permanent barrier between the door and <br />the glazing. <br />2. Glazing in Item 7 when a protective bar is installed on the accessible sides of the glazing 34 inches <br />(864 mm) to 38 inches (965 mm) above the floor. The bar shall be capable of withstanding a horizontal <br />load of 50 pounds per linear foot (729 N/m) without contacting the glass and be a minimum of 1 1/2 <br />inches (38.1 mm) in height. <br />3. Outboard pane in insulating glass units and in other multiple glazed panels in Item 7 when the bottom <br />exposed edge of the glass is 25 feet (7620 mm) or more above any grade, roof, walking surface or <br />other horizontal or sloped (within 45 degrees of horizontal) surface adjacent to the glass exterior. <br />4. Openings in door through which a 3-inch-diameter (76.2 mm) sphere will not pass. <br />5. Assemblies of leaded, faceted or carved glass in Items 1, 2, 6 and 7 when used for decorative <br />purposes. <br />6. Curved panels in revolving door assemblies. <br />7. Doors in commercial refrigerated cabinets. <br />8. Glass block panels complying with Section 2110. <br />9. Glazing in walls and fences used as the barrier for indoor and outdoor swimming pools <br />and spas when all of the following conditions are present: <br />9.1 The bottom edge of the glazing is less than 60 inches (1525 mm) above the pool <br />side of the glazing. <br />9.2 The glazing is within 5 feet (1525 mm) of a swimming pool or spa deck area. <br />10. Glazing in walls enclosing stairway landings or within 5 feet (1525 mm) of the bottom <br />and top of stairways where the bottom edge of the glass is less than 60 inches (1525 mm) <br />above a walking surface. <br />2406.5 Wardrobe Doors. Glazing in wardrobe doors shall meet the impact test requirements <br />for safety glazing as set forth in U.B.C. Standard 24-2, Part II. Laminated glass must also <br />meet the boil test requirements of U.B.C. Standard 24-2, Part II. <br />EXCEPTION: The impact test shall be modified so that if no breakage occurs when the <br />impacting object is dropped from the height of 18 inches (457 mm), the test shall progress in <br />height increments of 6 inches (152.5 mm) until the maximum of 48 inches (1219 mm) is <br />reached. <br />2406.6 Glass Railings. Glass used as structural balustrade panels in railings shall be one of <br />the following types: <br />1. Single fully tempered glass. <br />2. Laminated fully tempered glass. <br />3. Laminated heat-strengthened glass. <br />The panels and their support system shall be designed to withstand the load specified in <br />Table 16-B. A safety factor of 4 shall be used. <br />Each handrail or guardrail section shall be supported by a minimum of three glass balusters <br />or otherwise supported so that it remains in place should one baluster panel fail. <br />Glass balusters shall not be installed without a handrail or guardrail attached. <br />For all glazing types the minimum nominal thickness shall be 1/4 inch (6.35 mm). <br />Glazing materials shall not be installed in railings in parking garages except for those <br />locations where the railing is not exposed to impact from vehicles. <br />A. EXIT DOORS SHALL BE EQUIPPED WITH PANIC HARDWARE. S.S. <br />HARDWARE FINISH EXTERIOR DOOR LOCKSET 34" TO 48" A.F.F. <br />SUGATSUNE DSI-2000-30-60I, DORMA BTSBO CLOSER OR EQUAL <br />PER CONTRACTOR. SUBMIT TO CLIENT SPECIFICATIONS. <br />B. SINGLE INTERIOR DOOR LATCHSET 34" TO 48" A.F.F. FALCON T- <br />SERIES DANE GRADE I COMMERCIAL PASSAGE FUNCTION <br />C. EGRESS DOORS/GATES SHALL BE READILY OPENABLE FROM THE <br />EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL <br />KNOWLEDGE OR EFFORT. (1010.1.9) <br />D. OPENABLE PARTS OF SUCH HARDWARE SHALL BE 34 INCHES <br />MINIMUM AND 44 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR <br />GROUND. <br />E. THE FORCE FOR PUSHING OR PULLING OPEN A DOOR SHALL BE 5- <br />LB MAXIMUM. <br />F. OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND <br />SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF <br />THE WRIST. <br />G. A READILY VISIBLE DURABLE SIGN POSTED ON THE EGRESS SIDE <br />ON OR ADJACENT TO THE MAIN EXIT DOOR STATING: "THIS DOOR <br />TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED", IS <br />REQUIRED. (1010.1.9.4) <br />NOTE: ALL DOORS MUST MEET CITY OF SANTA ANA BUILDING & POLICE <br />DEPARTMENT APPROVAL & REQUIREMENTS. DOOR HARDWARE SHALL <br />BE ADA & MEET CBC 2022 ACCESSIBILITY REQUIREMENTS, SUBMIT FULL <br />SHOP DRAWINGS FOR ALL DOORS. <br />DOOR HARDWARE NOTES: <br />1. ALL LOCK SETS TO BE RE-KEYED PRIOR TO OWNER MOVE IN. <br />VERIFY WITH CLIENT & ALL LOCK SETS TO FUNCTION FROM ONE KEY. <br />HARDWARE NOTES: <br />1. STEEL OR ALUMINUM FRAME W/ SOLID CORE WOOD DOORS AND <br />OR GLASS. PAINTED TO MATCH AS DIRECTED BY CLIENT. VERIFY <br />W/ CLIENT <br />MATERIAL AND FINISH INDEX: <br />Scale <br />Date <br />Drawn By <br />Checked By <br />Project Number <br />14 <br />3 <br />0 <br /> <br />E <br /> <br />E <br />D <br />I <br />N <br />G <br />E <br />R <br /> <br />A <br />V <br />E <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />NOVUM <br />A R C H I T E C T U R E, Inc <br />www.novumarchitecture.com <br />OFFICES: SOUTH BAY / ORANGE COUNTY <br />116 S CATALINA AVE. STE. 122, <br />REDONDO BEACH, CA 90277 <br />TEL: 310-383-1827 / 310-709-4476 <br />N <br />DARIAN <br />RADAC <br />NO. C-33451 <br />RENEWAL DATE <br />LICENSED <br />STA <br />OE <br />CETIHCRA <br />T <br />T <br />F <br />INR <br />I O <br />CALF <br />A2-28-2025 <br />Darian Radac <br />As indicated <br />A-017 <br />TO <br />M <br />' <br />S <br /> <br />J <br />R <br />Checker <br />Author <br />9-03-2024 <br />tom's2023 <br />Do <br />o <br />r <br /> <br />& <br /> <br />W <br />i <br />n <br />d <br />o <br />w <br /> <br />S <br />c <br />h <br />e <br />d <br />u <br />l <br />e <br />s <br />Mr <br />. <br /> <br />S <br />p <br />i <br />r <br />o <br />s <br /> <br />P <br />o <br />l <br />i <br />t <br />i <br />s <br />Door Schedule <br />Door <br />Number Door Size <br />Frame <br />Type Fire Rating Description <br />Finish <br />Comments <br />1 Door-Curtain-Wall-Double-Storefront <br />2 36" x 80" <br />3 36" x 80" <br />4 Door-Curtain-Wall-Single-Glass <br />5 30" x 80" <br />6 36" x 108" <br />7 5' x 8' Metal Elec Room Door <br />8 42" x 80" <br />E 36" x 80" <br />E 36" x 84" <br />Window Schedule <br />Type Mark <br />Rough Opening <br />Manufacturer Material CommentsWidth Height <br />3/8" = 1'-0"1 Exterior Building Windows <br />WALK IN COOLER DOOR BY MANUFACTURER <br />WALK IN COOLER DOOR BY MANUFACTURER <br />DOUBLE 3'-0" WIDE TEMP GLASS ENTRY STOREFRONT DOOR. <br />SINGLE 3'-0" WIDE TEMP GLASS ENTRY STOREFRONT DOOR. PROVIDE PANIC HARDWARE. <br />MTL N/A <br />MTL N/A <br />MTL N/A <br />MTL N/A <br />MTL N/A <br />MTL N/A <br />MTL N/A <br />MTL N/A <br />MTL N/A <br />MTL N/A <br />"A" TYPE <br />"B" TYPE <br />"C" TYPE <br />"D" TYPE <br />"E" TYPE <br />"F" TYPE <br />"G" TYPE <br />"H" TYPE <br />11'-3" 5'-0" WESTERN OR EQUAL MTL REFER TO EXTERIOR ELEVATIONS, TEMP GLASS INSULATED UNITS <br />PROVIDE LOUVERS PER MANUF SPECIFICATIONS <br />8'-0" 6'-0" WESTERN OR EQUAL MTL REFER TO EXTERIOR ELEVATIONS, TEMP GLASS INSULATED UNITS W/ SELF CLOSING MECHANISM. <br />4'-7" 6'-2" WESTERN OR EQUAL MTL REFER TO EXTERIOR ELEVATIONS, TEMP GLASS INSULATED UNITS W/ SELF CLOSING MECHANISM. <br />22'-0" 5'-0" WESTERN OR EQUAL MTL REFER TO EXTERIOR ELEVATIONS, TEMP GLASS INSULATED UNITS <br />6'-6" 1'-6" WESTERN OR EQUAL MTL REFER TO EXTERIOR ELEVATIONS, TEMP GLASS INSULATED UNITS <br />6'-5" 1'-6" WESTERN OR EQUAL MTL REFER TO EXTERIOR ELEVATIONS, TEMP GLASS INSULATED UNITS <br />21'-8.5" 5'-0" WESTERN OR EQUAL MTL REFER TO EXTERIOR ELEVATIONS, TEMP GLASS INSULATED UNITS <br />6'-0" 2'-0" WESTERN OR EQUAL MTL REFER TO EXTERIOR ELEVATIONS, TEMP GLASS INSULATED UNITS <br />No. Description Date <br />PROVIDE PANIC HARDWARE. <br />1430 E Edinger Ave <br />3/27/2025