Laserfiche WebLink
400 Sunrise Ave., Suite 270 <br />Roseville, CA 95661 <br />916.755.3571 / MiTek-US.com <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) <br />BCSI Building Component Safety Information <br />WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. <br />and available from the Structural Building Component Association (www.sbcscomponents.com) <br />0.2512 <br />=3x6 <br />=4x5 =6x8=2x6 <br />=7x8 <br />=5x10 <br />=4x5 <br />=2x6 =4x6 <br />=1.5x4 <br />=3x4 <br />=3x6 <br />=2x4 <br />21 22 26 <br />15 <br />14 139 8 27 <br />7 <br />12 <br />11 25 102423 <br />1 17 2 18 3 <br />4 19 5 20 6 <br />16 <br />0-6-7 <br />0-8-3 <br />2-6-0 <br />0-5-10 <br />2-11-10 <br />1-9-13 <br />1-9-13 <br />1-10-0 <br />4-9-10 <br />3-1-5 <br />7-10-15 <br />0-1-12 <br />4-9-10 <br />0-1-12 <br />1-11-9 <br />0-2-13 <br />2-8-13 <br />0-0-14 <br />2-6-0 <br />0-5-9 <br />2-5-2 <br />0-7-2 <br />3-3-15 <br />1-3-14 <br />4-7-13 <br />1-9-13 <br />1-9-13 <br />3-1-5 <br />7-10-15 <br />6-6-0 <br />1-2-0 <br />1-11 <br />-6 <br />0-0-2 <br />0-7-4 <br />0-7-8 <br />0-7-4 <br />0-7-4 <br />0-7-6 <br />1-2-10 <br />0-7-8 <br />1-10 <br />-2 <br />4-7-14 <br />6-6-0 <br />Scale = 1:62.3 <br />Plate Offsets (X, Y):[2:0-1-8,0-2-12], [3:0-3-0,0-3-6], [11:0-2-8,0-0-1] <br />Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP <br />TCLL (roof)20.0 Plate Grip DOL 1.25 TC 0.84 Vert(LL)-0.02 7-8 >999 360 MT20 220/195 <br />TCDL 14.0 Lumber DOL 1.25 BC 0.54 Vert(CT)-0.03 7-8 >999 240 <br />BCLL 0.0 *Rep Stress Incr NO WB 0.52 Horz(CT)0.01 7 n/a n/a <br />BCDL 7.0 Code IBC2021/TPI2014 Matrix-MSH Wind(LL)0.01 7-8 >999 240 Weight: 51 lb FT = 20% <br />LUMBER <br />TOP CHORD 2x4 DF No.2 G <br />BOT CHORD 2x4 DF No.2 G *Except* 11-9:2x4 DF No.2 G <br />or 2x4 DF Std G or 2x4 DF Stud G <br />WEBS 2x4 DF No.2 G or 2x4 DF Std G or 2x4 DF <br />Stud G *Except* 12-16:2x6 DF No.2 G <br />BRACING <br />TOP CHORD Structural wood sheathing directly applied or <br />6-0-0 oc purlins, except end verticals. <br />Except: <br />7-9-0 oc bracing: 4-16 <br />BOT CHORD Rigid ceiling directly applied or 5-10-0 oc <br />bracing. Except: <br />3-6-0 oc bracing: 2-12 <br />REACTIONS (size)7= Mechanical, 12=0-5-8 <br />Max Horiz 12=214 (LC 9) <br />Max Uplift 7=-127 (LC 9), 12=-173 (LC 8) <br />Max Grav 7=450 (LC 31), 12=862 (LC 25) <br />FORCES (lb) - Maximum Compression/Maximum <br />Tension <br />TOP CHORD 1-15=-224/460, 1-2=-17/130, 2-3=-844/2627, <br />3-12=-513/589, 3-4=-373/571, 4-16=0/0, <br />4-5=-655/546, 5-6=-57/19, 6-7=-418/71 <br />BOT CHORD 14-15=-124/11, 13-14=0/0, 2-12=-2696/888, <br />11-12=-1085/1801, 10-11=-856/1419, <br />9-11=-72/71, 8-9=-304/382, 7-8=-476/576 <br />WEBS 5-7=-624/503, 8-10=-60/276, 5-10=-281/421, <br />4-10=-1214/780, 2-15=-131/152, <br />2-14=-52/588 <br />NOTES <br />1)Wind: ASCE 7-16; Vult=96mph (3-second gust) <br />Vasd=76mph; TCDL=8.4psf; BCDL=4.2psf; h=25ft; Cat. <br />II; Exp C; Enclosed; MWFRS (envelope) exterior zone <br />and C-C Corner (3) 0-1-13 to 7-9-3 zone; cantilever left <br />and right exposed ; end vertical left and right <br />exposed;C-C for members and forces & MWFRS for <br />reactions shown; Lumber DOL=1.60 plate grip <br />DOL=1.60 <br />2)Provide adequate drainage to prevent water ponding. <br />3)This truss has been designed for a 10.0 psf bottom <br />chord live load nonconcurrent with any other live loads. <br />4)* This truss has been designed for a live load of 20.0psf <br />on the bottom chord in all areas where a rectangle <br />3-06-00 tall by 2-00-00 wide will fit between the bottom <br />chord and any other members. <br />5)A plate rating reduction of 20% has been applied for the <br />green lumber members. <br />6)Bearings are assumed to be: Joint 12 DF No.2 crushing <br />capacity of 625 psi. <br />7)Refer to girder(s) for truss to truss connections. <br />8)Provide mechanical connection (by others) of truss to <br />bearing plate capable of withstanding 173 lb uplift at <br />joint 12 and 127 lb uplift at joint 7. <br />9)This truss has been designed for a moving concentrated <br />load of 300.0lb live and 80.0lb dead located at all mid <br />panels and at all panel points along the Top Chord and <br />Bottom Chord, nonconcurrent with any other live loads. <br />10)This truss is designed for a creep factor of 2.01, which is <br />used to calculate the Vert(CT) deflection per ANSI/TPI 1. <br />The building designer shall verify that this parameter fits <br />with the intended use of this component. <br />LOAD CASE(S) Standard <br />1)Dead + Roof Live (balanced): Lumber Increase=1.25, <br />Plate Increase=1.25 <br />Uniform Loads (lb/ft) <br />Vert: 1-3=-68, 4-6=-68, 13-15=-30, 2-24=-30, <br />11-24=-14, 7-9=-14 <br />Job Truss Truss Type Qty Ply M39558- TOMS JR SANTA ANA <br />R80031819AF08Roof Special 1 1M39885- TOMS JR Job Reference (optional) <br />Builders FirstSource (Perris, CA), Perris, CA - 92570,Run: 8.63 S Nov 1 2023 Print: 8.630 S Nov 1 2023 MiTek Industries, Inc. Wed Dec 27 09:56:06 Page: 1 <br />ID:rqHPvSxFScf1h8YnWt81iVyDWyn-RfC?PsB70Hq3NSgPqnL8w3uITXbGKWrCDoi7J4zJC?f <br />December 27,2023 <br />1430 E Edinger Ave <br />3/27/2025