Laserfiche WebLink
Be am ID: 27 Fl Bm @ RTU1 <br />Section type:Douglas Fir-Larch No.2 <br />Section name:4x8 <br />Fb(+)/Fb(-) (psi): 900/900 Fv (psi): 180 <br />E (psi): 1600000 Lu (ft): 0 <br />Ignore shear within (d): True Repetitive member : False <br />Applie d Loads: <br />Load_Roof 146.25PLF =4.5 x (45+20)/2 @ 0' to 7.75' <br />SELF WEIGHT 5.95PLF From 0' to 7.75' <br />Factors: <br />Ct = 1 Cm = 1 CL = 1.00 CF = 1.3 Cfu = 1 Ci = 1 Cr = 1 CT = 1 <br />Re actions: <br />Support D L Lr S WSN WWE ESN EWE M ax. LC (Down/Up) <br />1 415 0 174 0 0 0 0 0 590/0 <br />2 415 0 174 0 0 0 0 0 590/0 <br />Code che ck: <br />Actual Loc.(ft)Allowe d Ratio (%)CD <br />Moment (lbs-ft)1143 3.88 3737 31 1.25 <br />Shear (lbs)492 0 3806 13 1.25 <br />Live Deflection 0.021 3.88 0.258 8 - <br />Total Deflection 0.069 3.88 0.388 18 - <br />Passe d <br />Max Moment: D + Lr <br />Max Shear: D + Lr <br />Max Deflection: D + Lr <br />Be am ID: 28A Fl Bm @ KEF2 <br />Section type:Douglas Fir-Larch No.2 <br />Section name:4x8 <br />Fb(+)/Fb(-) (psi): 900/900 Fv (psi): 180 <br />E (psi): 1600000 Lu (ft): 0 <br />Ignore shear within (d): True Repetitive member : False <br />Applie d Loads: <br />Load_Roof 48.75PLF =1.5 x (45+20)/2 @ 1.5' to 3' <br />SELF WEIGHT 5.95PLF From 0' to 7.25' <br />Factors: <br />Ct = 1 Cm = 1 CL = 1.00 CF = 1.3 Cfu = 1 Ci = 1 Cr = 1 CT = 1 <br />Re actions: <br />Support D L Lr S WSN WWE ESN EWE M ax. LC (Down/Up) <br />1 56 0 16 0 0 0 0 0 72/0 <br />2 37 0 7 0 0 0 0 0 44/0 <br />Code che ck: <br />Actual Loc.(ft)Allowe d Ratio (%)CD <br />Moment (lbs-ft)107 2.68 2691 4 0.9 <br />Shear (lbs)56 0 2741 2 0.9 <br />Live Deflection 0.001 3.26 0.242 0 - <br />Total Deflection 0.007 3.41 0.362 2 - <br />Passe d <br />Max Moment: D <br />Max Shear: D <br />Max Deflection: D + Lr <br />vG23.06.30 <br />: <br />: <br />: <br />: <br />Com pany CORE STRUCTURE, INC. <br />Project Tom's Jr <br />Job No.23033 <br />Plan <br />: <br />: <br />: <br />: <br />Designed <br />Checked <br />Date 08/16/2024 <br />Client 0 <br />TIC Structure Design 2023 <br />20 <br />1430 E Edinger Ave <br />3/27/2025