My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1430 E Edinger Ave-REV 1 - Plan
PBA
>
Building
>
ProjectDox
>
E
>
Edinger Ave
>
1430 E Edinger Ave
>
1430 E Edinger Ave-REV 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:02:00 AM
Creation date
2/24/2026 5:00:43 AM
Metadata
Fields
Template:
Plan
Permit Number
20183198
20186203
30147418
30148982
40139225
40140476
101119781
101119782
Full Address
1430 E Edinger Ave
Street Number
1430
Street Direction
E
Street Name
Edinger
Street Suffix
Ave
Document Relationships
101119781 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
101119782 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
20183198 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
20186203 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
30147418 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
30148982 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
40139225 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
40140476 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Edinger Ave\1430 E Edinger Ave
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
931
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
APPROXIMATE <br />LOCATION OF <br />EXISTING <br />POWER POLE <br />1 <br />E EDINGER AVE <br />GR <br />A <br />N <br />D <br /> <br />A <br />V <br />E <br />P <br />NEW MSB IN THE <br />ELECTRICAL ROOM <br />L <br />K <br />MSB <br />J <br />J <br />J <br />J <br />J <br />WP <br />J <br />J <br />J <br />WP <br />WP <br />WP <br />WP <br />WPJ <br />WP <br />WP <br />J WP <br />L-13 <br />2 <br />2L-11 <br />2L-1 <br />2L-3 <br />L-5 <br />2L-9 <br />L-7 <br />3 <br />5 <br />5 <br />4 <br />4 <br />S1 <br />S1 <br />S2 <br />S2 <br />L-3 <br />L-3 <br />L-1 <br />L-1 <br />L-5 <br />5 <br />L-15 <br />2 <br />6 <br />6 <br />6 <br />6 <br />J <br />WP <br />J <br />WP <br />L-10 <br />2 <br />L-12 <br />2 <br />GENERAL NOTES: <br />A.ALL EQUIPMENT AND DEVICES OUTDOOR SHALL BE WEATHER <br />PROOF WITH NEMA 3R ENCLOSURE. <br />B.CONTRACTOR SHALL OBTAIN UTILITY COMPANY DRAWINGS <br />PRIOR TO SUBMITTING BID AND PROVIDE ALL ITEMS INDICATED IN <br />THE UTILITY COMPANY DRAWINGS AS PART OF THE <br />CONTRACTOR'S RESPONSIBILITY. INCLUDE ALL COSTS FOR <br />INSTALLATION OF UTILITY EQUIPMENT IN THEIR BASE BID. <br />C.PROVIDE ALL MATERIAL AND ALL WORK TO COMPLY WITH POWER <br />COMPANY FINAL CONSTRUCTION PLANS, STANDARD AND <br />BUILDING AND SAFETY REQUIREMENT. CONTRACTOR TO <br />INCLUDE IN HIS BASE BID. <br />D.COORDINATE ALL LANDSCAPE LIGHTING LOCATIONS AND AIMING <br />WITH LANDSCAPE ARCHITECT PRIOR TO ROUGH-IN. <br />E.ALL BENDS, TURNS, AND CHANGE OF DIRECTION IN CONDUIT <br />SHALL BE MADE UTILIZING RIGID STEEL FITTINGS TO PREVENT <br />DAMAGE TO CONDUIT AND FUTURE CABLES DURING CABLE <br />INSTALLATION. <br />F.VERIFY ALL UTILITY LOCATIONS AND REQUIREMENTS WITH <br />UTILITY COMPANY INSTALLATION DRAWINGS PRIOR TO <br />BEGINNING EXCAVATION. <br />G.ALL EXTERIOR CONDUIT INSTALLED UNDERGROUND SHALL BE 1" <br />MINIMUM UNLESS INDICATED OTHERWISE. <br />H.ALL EXTERIOR WIRING INSTALL UNDERGROUND SHALL BE #10 <br />MINIMUM UNLESS INDICATED OTHERWISE. <br />I.ALL GRADE MOUNTED PULL BOXES SHALL HAVE 4" CONCRETE <br />COLLAR UNLESS OTHERWISE NOTED. <br />J.ALL OUTDOOR LIGHTING SHALL BE CONNECTED TO A LIGHTING <br />CONTROL PANEL U.N.O, <br />K.ALL NEW CABLES AND WIRES SHALL BE CU AND IN A CONDUIT. <br />L.ALL ELECTRICAL EQUIPMENT AND MATERIALS SHALL BE LISTED, <br />LABELED AND APPROVED BY A DULY AUTHORIZED ELECTRICAL <br />TESTING AGENCY. <br />M.ALL WORK SHALL COMPLY WITH ALL MUNICIPAL AND STATE <br />ELECTRICAL CODE AND ALL OTHER AGENCY HAVING <br />JURISDICTION. <br />N.PROVIDE PULL BOX SIZED PER CODE AS REQUIRED. <br />O.ALL CONDUIT STUBS SHALL BE FIELD COORDINATE WITH <br />EQUIPMENT INSTALLATION MANUALS PRIOR TO ANY ROUGH-INS. <br />P.CONTRACTOR TO CHECK EQUIPMENT LANDING LUGS AND <br />PROVIDE REQUIRED LUG SIZE TO ACCOMMODATE SPECIFIED <br />WIRE SIZE PER FEEDER SCHEDULE. CONTRACTOR TO FIELD <br />COORDINATE. <br />Q.MAXIMUM CONDUIT FILL FOR ALL ELECTRICAL WORK WITHIN <br />CLASSIFIED AREA SHALL BE 25%. <br />R.EACH UNDERGROUND FEEDER AND BRANCH CIRCUITS SHALL BE <br />COPPER AND IN PVC CONDUIT SCHEDULE 40 MIN. U.O.N. <br />S.ALL EXTERIOR UNDERGROUND CONDUIT MUST BE BURIED AT A <br />MINIMUM DEPTH OF 24 INCHES. <br />1 <br />ELECTRICAL SITE PLAN <br />SCALE: 1/8" = 1'-0" <br />NORTH <br />1 <br />KEY NOTES: <br />PROVIDE HOUSE SIDE SHIELD. <br />PROVIDE CONNECTION TO ASTRONOMICAL TIME CLOCK AND PHOTO <br />CELL CONTROL. <br />PROVIDE WP J-BOX FOR CONNECTION TO MONUMENT SIGN. VERIFY AND <br />COORDINATE EXACT LOCATION WITH OWNER/SIGN CONTRACTOR AND IN <br />THE FIELD. <br />PROVIDE WP J-BOX AND DATA FOR CONNECTION TO MENU BOARD. VERIFY <br />AND COORDINATE EXACT LOCATION WITH OWNER/MENU BOARD <br />CONTRACTOR AND IN THE FIELD. <br />PROVIDE WP J-BOX FOR CONNECTION TO BUILDING SIGN. VERIFY AND <br />COORDINATE EXACT LOCATION WITH OWNER/SIGN CONTRACTOR AND <br />IN THE FIELD. <br />REFER TO POLE BASE DETAIL ON SHEET E5.02 DETAIL #12.(TYPICAL) <br />Scale <br />Date <br />Drawn By <br />Checked By <br />Project Number <br />14 <br />3 <br />0 <br /> <br />E <br /> <br />E <br />D <br />I <br />N <br />G <br />E <br />R <br /> <br />A <br />V <br />E <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />NOVUM <br />A R C H I T E C T U R E, Inc <br />www.novumarchitecture.com <br />OFFICES: SOUTH BAY / ORANGE COUNTY <br />116 S CATALINA AVE. STE. 122, <br />REDONDO BEACH, CA 90277 <br />TEL: 310-383-1827 / 310-709-4476 <br />N <br />AS SHOWN <br />TO <br />M <br />' <br />S <br /> <br />J <br />R <br />CAD <br />Author <br />9-1-2023 <br />tom's2023 <br />Mr <br />. <br /> <br />S <br />p <br />i <br />r <br />o <br />s <br /> <br />P <br />o <br />l <br />i <br />t <br />i <br />s <br />No.Description Date <br />1 PC Comments 08/08/2024 <br />2 HlthDep.Corr.2 09/03/2024 <br />ELECTRICAL SITE <br />PLAN <br />E-108 <br />RESTAURANT <br />2,4589 SF <br />2 <br />3 <br />4 <br />5 <br />6 <br />1 <br />1430 E Edinger Ave <br />3/27/2025
The URL can be used to link to this page
Your browser does not support the video tag.