Laserfiche WebLink
HANGER ROD <br />3. DO NOT SUPPORT HANGER FROM SLAB DIAPHRAGMS. <br />2. MOUNT HANGER BOX DIRECTLY AGAINST STRUCTURAL ELEMENT. <br />1. WHEN MOUNTING EQUIPMENT, ALIGN HANGER ROD TO CLEAR HANGER BOX. <br />5. PROVIDE A MINIMUM 1/2-INCH GAP BETWEEN THE METAL HANGER BOX AND STRUCTURE. <br />6. PROVIDE 1/2" CLEARANCE BETWEEN THE METAL HANGER BOX AND THE STRUCTURE. <br />4. TYPE HN = CALDYNE TYNE CH30. <br />NOTES: <br />METAL HANGER BOX <br />ISOLATION ELEMENT <br />NEOPRENE RUBBER <br />UPPER ATTACHMENT <br />STRUCTURE <br />WASHER <br />W <br />1" MIN. (TYP.) <br />SQUARE TO ROUND TRANSITION <br />L1 <br />AIR FLOW <br />SUPPLY <br />45° <br />PLAN <br />D <br />ELEVATION <br />D X D <br />SQUARE DUCT <br />DUCT TAP SIZE <br />L1 = 1.5 BRANCH <br />DUCT DIAMETER <br />DIMENSION <br />BAND OF SAME SIZE AS <br />HANGER STRAP <br />LOAD RATED FASTENERS <br />NOTE: ALL DUCTWORK HANGER AND SUPPORT SHALL BE PER SMACNA <br />HANGER <br />36" DIA. MAX. <br />HANGER <br />24" DIA. MAX. <br />SECURE WIRE <br />10" DIA. MAX. <br />(SCREWS MAY BE OMITTED IF <br />HANGER LOOPS) <br />SCREWS <br />HANGERS MUST NOT DEFORM DUCT SHAPE <br />(ONE HALF-ROUND MAY BE USED IF DUCT <br />SHAPE IS MAINTAINED) <br />BAND <br />BOTTOM REINFORCEMENT <br />IS PLACE UNDER A <br />UNLESS FOOT OF STRAP <br />1" MIN <br />HANGER <br />STRAPS <br />60" MAX <br />STRAP HANGERS <br />HANGER ROD, WIRE <br />OR STRAPS <br />34 <br />" <br /> <br />M <br />A <br />X <br />. <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br />FINISHED <br />FLOOR <br />THERMOSTAT, <br />SWITCH, OUTLET, <br />CONTROL <br />15 <br />" <br /> <br />M <br />I <br />N <br />. <br />24" MAX.TOP OF THERMOSTAT, <br />SWITCH, OUTLET, <br />CONTROL <br />Scale <br />Date <br />Drawn By <br />Checked By <br />Project Number <br />14 <br />3 <br />0 <br /> <br />E <br /> <br />E <br />D <br />I <br />N <br />G <br />E <br />R <br /> <br />A <br />V <br />E <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />NOVUM <br />A R C H I T E C T U R E, Inc <br />www.novumarchitecture.com <br />OFFICES: SOUTH BAY / ORANGE COUNTY <br />116 S CATALINA AVE. STE. 122, <br />REDONDO BEACH, CA 90277 <br />TEL: 310-383-1827 / 310-709-4476 <br />N <br />AS SHOWN <br />TO <br />M <br />' <br />S <br /> <br />J <br />R <br />DC <br />TT <br />9-1-2023 <br />tom's2023 <br />Mr <br />. <br /> <br />S <br />p <br />i <br />r <br />o <br />s <br /> <br />P <br />o <br />l <br />i <br />t <br />i <br />s <br />No.Description Date <br />1 PC Comments 08/08/2024 <br />2 HlthDep.Corr.2 09/03/2024 <br />TRAP <br />FITTING <br />SLIP-JOINT <br />FLOOR <br />FINISHED <br />LAVATORY <br />OR SINK <br />WALL <br />ESCUTCHEON <br />PLATE <br />IN WALL. <br />DRAIN DOWN <br />N.T.S <br />9CONDENSATE DRAIN CONNECTION <br />TO LAVATORY TAILPIECE DETAIL <br />CEILING GRILLE <br />FAN BODY <br />MOUNTING BRACKETS <br />2-3FT STRAIGHT <br />RUN BEFORE <br />ELBOW <br />SHORT PIECE OF <br />FLEXIBLE DUCTS TO <br />HELP ALIGNNMENT <br />AND ABSORB SOUND <br />CEILING <br />N.T.S <br />6CEILING EXHAUST FAN DETAIL N.T.S <br />4ISOLATION HANGER DETAIL N.T.S <br />1CONTROLS MOUNTING DETAIL <br />WITH AIR CONDITIONING UNITS FURNISHED. <br />INFORMATION ONLY. VERIFY ALL UTILITIES <br />AIR CONDITIONING UNIT SHOWN IS FOR <br />NOTE: <br />GALVANIZED IRON <br />PLENUMS <br />RETURN AIR <br />LINED SUPPLY &INSTALL SMOKE DETECTOR IN SA <br />DUCT INTERLOCKED WITH UNIT <br />CONTROLS FOR SHUTDOWN <br />A/C SYSTEMS WITH 2000 CFM <br />THIS SHEET <br />FACTORY CURB <br />SEE DETAIL ON <br />CONDENSATE DRAIN- <br />SEE PLUMB. DRAWINGS <br />SUPPLY AIR <br />SEE EQUIPMENT SPECS. <br />ROOFTOP PACKAGED UNIT FRESH AIR INTAKE <br />W/ BACKDRAFT <br />DAMPER <br />AND HIGHER DUCT SMOKE DETECTOR <br />NOTES: <br />1.FOR REFERENCE ONLY. REFER TO <br />ARCHITECTURAL/ STRUCTURAL DRAWING FOR <br />MORE DETAILS. <br />DUCT <br />N.T.S <br />10ROOFTOP UNIT DETAIL N.T.S <br />7ROOF PIPE PENETRATION DETAIL N.T.S <br />5ROOF PIPE SUPPORT DETAIL N.T.S <br />2TYPICAL CONDENSATE DRAIN <br />CONNECTION DETAIL <br />ROOF CONSTRUCTION <br />WOOD CANT <br />SLOPE PIPES AWAY <br />GENERAL CONTRACTOR <br />WOOD CURB BY <br />BASE FLASHING <br />FROM HOOD <br />20 GAUGE GALVANIZED <br />SHEET METAL HOOD <br />SEAL WITH MASTIC <br />SHEET METAL COLLAR <br />DRAIN PAN <br />A <br />6" <br />C.O. <br />B <br />C.O. <br />DI-ELECTRIC <br />COUPLING/UNION <br />SIZETONS <br />SIZED AS PER CMC 310.3: <br />3/4" <br />1" <br />1-1/4" <br />0-20 <br />21-40 <br />41-90 <br />2" MIN <br />DRAW THRU <br />DRAIN LINES SHALL BE <br />C.O. <br />VENT NO MORE THAN 10' <br />PITCH DOWNWARD TOWARDS <br />SPILL OVER RECEPTACLE <br />FROM TRAP <br />DRAIN @ 1/8" PER FOOT <br />A = S.P. x 1.5 + 2" <br />B = S.P. x 0.5 + 2" <br />@ 2" ABOVE FLOOR OR <br />TAILPIECE <br />CONN INTO FIXTURE <br />S.P. = MAX. NEGATIVE STATIC <br /> PRESSURE - INCHES <br />1-1/2"91-125 <br />2"126-250 <br />(AS REQUIRED) <br />EATON "DURA-BLOK" <br />SUPPORT SYSTEM <br />ROOF <br />MOUNTED <br />PIPING <br />4" MIN. A.F.R. <br />WOODEN BLOCKS SHALL <br />NOT BE USED AS PIPING <br />SUPPORTS ON THE ROOF <br />RUBBER <br />BASE <br />1. SUPPORTS SHALL BE INSTALLED A MAXIMUM 8'-0" O.C. <br />AND AT EACH CHANGE OF DIRECTION OF PIPING. <br />2. CONTRACTOR TO PROVIDE ALL NECESSARY <br />ACCESSORIES, INCLUDING CLAMPS AND COLLARS. <br />NOTES <br />8" DN. <br />9"-16" <br />17"-28" <br />29"-40" <br />41"-52" <br />53"-64" <br />65"-76" <br />77"-88" <br />89"-100"9 <br />8 <br />7 <br />6 <br />5 <br />4 <br />3 <br />2 <br />0 <br />LINER INTERIOR <br />WIDTH <br />NO. <br />PINS <br />LAPPED & BUTTED <br />CORNER <br />DETAIL-A <br />AIR FLOW <br />ALTERNATE <br />FOLDED <br />C <br />B <br />C <br />C <br />B <br />B <br />A <br />E <br />E <br />A <br />LINER <br />WASHER <br />E <br />18" <br />16"4" <br />4" <br />CB <br />12" <br />6"3" <br />3" <br />A <br />DIMENSIONS <br />2501-6000 FPM <br />0-2500 FPM <br />VELOCITY * <br />MAXIMUM SPACING FOR FASTENERS. <br />ACTUAL INTERVALS ARE APPROXIMATE. <br />* UNLESS A LOWER LEVEL IS SET BY <br />MANUFACTURER OR LISTING AGENCY <br />PIN (TYP) <br />SEE DETAIL-B <br />ALL TRANSVERSE <br />EDGES TO BE COATED <br />WITH ADHESIVE <br />LINER ADHERED TO THE <br />DUCT WITH 90% MIN. AREA <br />COVERAGE OF ADHESIVE <br />DUCT SECTION <br />(TYP 4 OR 5 FEET) <br />DUCT LINER AIR SIDE & <br />EDGES SHALL BE <br />COMPLETELY WRAPPED WITH <br />PERFORATED LINER. <br />WELDED PIN <br />PRESS-ON HEAD <br />LINER FASTENERS <br />DETAIL B <br />NOTE: <br />THE VELOCITY RATED <br />SIDE OF LINER MUST <br />FACE THE AIR FLOW <br />CORNER <br />N.T.S <br />11DUCT LINING DETAIL N.T.S <br />8RECTANGULAR TO ROUND <br />BRANCH TAP DETAIL N.T.S <br />3DUCT HANGER DETAIL <br />MECHANICAL <br />DETAILS - SHEET 1 <br />M-207 <br />1430 E Edinger Ave <br />3/27/2025