Laserfiche WebLink
Scale <br />Date <br />Drawn By <br />Checked By <br />Project Number <br />14 <br />3 <br />0 <br /> <br />E <br /> <br />E <br />D <br />I <br />N <br />G <br />E <br />R <br /> <br />A <br />V <br />E <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />NOVUM <br />A R C H I T E C T U R E, Inc <br />www.novumarchitecture.com <br />OFFICES: SOUTH BAY / ORANGE COUNTY <br />116 S CATALINA AVE. STE. 122, <br />REDONDO BEACH, CA 90277 <br />TEL: 310-383-1827 / 310-709-4476 <br />N <br />AS SHOWN <br />TO <br />M <br />' <br />S <br /> <br />J <br />R <br />CAD <br />Author <br />9-01-2023 <br />tom's2023 <br />Mr <br />. <br /> <br />S <br />p <br />i <br />r <br />o <br />s <br /> <br />P <br />o <br />l <br />i <br />t <br />i <br />s <br />No.Description Date <br />1 PC Comments 07/16/2024 <br />2 HlthDep.Corr.2 09/03/2024 <br />3 PC Corr.2 07/01/2025 <br />PLUMBING <br />DETAILS <br />P-106 <br />SANTEE FITTING <br />AS J R SMITH # 4472 <br />SOIL OR WASTE <br />CLEANOUT <br />PLUG <br />WALL <br />WALL CLEANOUT <br />& COVER PLATE <br />NTS <br />TYPICAL VENT PIPE THROUGH ROOF NTS <br />NTSWATER HEATER DETAIL <br />2 <br />1 <br />4 <br />NTS 5 <br />SET PIPE IN <br />YEAGAR LEAD <br />ROOF FLASHING <br />ROOFING <br />SKIRT <br />MASTIC <br />PIPE THROUGH ROOF <br />SEE FLOOR PLAN FOR <br />SIZE/TYPE AND LOCATION <br />ROOF <br />12" MIN. <br />NTS 3 WALL CLEAN-OUT DETAIL <br />CONDENSATE TO TALEPIECE <br />CONDENSATE DRAIN <br />DOWN IN WALL <br />C.P. ESCUTCHEON <br />DRAIN FROM UNIT <br /> APPROVED HOSE <br />AND S.S. HOSE CLAMPS <br />1-1/2" P-TRAP <br />CLEANOUT <br />NOTE: <br />ADJUST ROUGH-IN <br />HEIGHT AS REQ'D. <br />CABINET TOP <br />1-1/2"X4" 17 GA. <br />BRANCH TAILPIECE <br />FROST #5606 OR <br />SIMILAR. <br />CONDENSATE DRAIN CONNECTION <br />MECH. <br />EQUIP. <br />PLUG FOR BLOW <br />THRU UNITS. <br />VENT (LEAVE OPEN) <br />CAPPED TEE <br />FOR CLEANOUT <br />NEOPRENE HOSE. (SAME P1.1 <br />AS CONDENSATE DRAIN). <br />STAINLESS STEEL <br />HOSE CLAMP. <br />CONDENSATE DRAIN. SEE PLAN <br />FOR SIZE AND CONTINUATION. <br />1" MIN. <br />3" MIN. <br />2 <br />Remote <br />Control <br /> F <br />WH-1 WH-1 <br />Cold Water <br />Supply <br />Hot Water <br />to Fixtures <br />Drip Leg Gas <br />Supply <br />Written System Description <br />Two Unit Tankless Installation: <br />Two tankless water heaters shall be installed, connected with a <br />EZ-Link cable, a single remote control and vented to the outside <br />per the manufacture instructions. The tankless units shall be <br />plumbed in parallel manifold system with a minimum gas and <br />water header of an 1” pipe or as code requires. Cold water will <br />feed the tankless units, the tankless shall supply a single <br />temperature setting of water for kitchen or appliance use. <br />Plumbing, pipe size, valves, all to be determined by mechanical <br />engineers or the installing contractor. <br />This drawing is intended as a guide only. It is not to be used as <br />an alternative to a professionally engineered project drawing. <br />This drawing does not imply compliance with local building <br />codes. Installation may vary, depending on installation location, <br />and must be done in accordance with all local building codes. <br />Consult with local building officials prior to installation. <br />System Components <br />H-1-3 Indoor or Outdoor Tankless Water Heater <br />C-1 EZ-Link Cable (RTG20040) <br />(2) Tankless Service Valve Kits (Webstone EXP2 or equivalent) <br />(2) Pressure Relief Valve for tankless <br />Legend Drawing No TKPD12102 5/12 <br />Cold Water Isolator <br />Valve Assembly <br />Hot Water Isolator <br />Valve Assembly <br />Pressure Relief <br />Valve <br />Circulation <br />Pump <br />Shut-off Valve <br />Check Valve <br />Union <br />ET-1 <br />CP-1Hot Water <br />Return <br />1430 E Edinger Ave <br />3/27/2025