My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1410 N Parsons Pl - Plan
PBA
>
Building
>
ProjectDox
>
P
>
Parsons Pl
>
1410 N Parsons Pl
>
1410 N Parsons Pl - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:01:26 AM
Creation date
2/24/2026 5:00:52 AM
Metadata
Fields
Template:
Plan
Permit Number
20185497
101122250
Full Address
1410 N Parsons Pl
Street Number
1410
Street Direction
N
Street Name
Parsons
Street Suffix
Pl
Rectangle
ID:
1
Creator:
Import Agent
Created:
2/24/2026 5:01 AM
Modified:
2/12/2026 7:41 AM
ID:
2
Creator:
Import Agent
Created:
2/24/2026 5:01 AM
Modified:
2/12/2026 7:41 AM
ID:
3
Creator:
Import Agent
Created:
2/24/2026 5:01 AM
Modified:
2/12/2026 7:41 AM
ID:
4
Creator:
Import Agent
Created:
2/24/2026 5:01 AM
Modified:
2/12/2026 7:41 AM
ID:
5
Creator:
Import Agent
Created:
2/24/2026 5:01 AM
Modified:
2/12/2026 7:41 AM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
RE <br />V <br />I <br />S <br />I <br />O <br />N <br />S <br />DA <br />T <br />E <br />DI <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br />1/ <br />1 <br />6 <br />/ <br />2 <br />4 <br />RE <br />V <br />Se <br />e <br /> <br />S <br />O <br />W <br /> <br />P <br />V <br /> <br />1 <br />A <br />(4 <br />) <br /> <br />(N <br />) <br /> AP <br />S <br />y <br />s <br />t <br />e <br />m <br />s <br /> <br />D <br />S <br />3 <br />- <br />L <br />Mi <br />c <br />r <br />o <br />i <br />n <br />v <br />e <br />r <br />t <br />e <br />r <br />( <br />s <br />) <br />: <br />(8) <br />(N <br />) <br /> JA <br /> <br />S <br />o <br />l <br />a <br />r <br /> <br />J <br />A <br />M <br />5 <br />4 <br />S <br />3 <br />1 <br />- <br />3 <br />9 <br />5 <br />/ <br />M <br />R <br />Mo <br />d <br />u <br />l <br />e <br />: <br />DC <br /> <br />S <br />y <br />s <br />t <br />e <br />m <br /> <br />S <br />i <br />z <br />e <br />: <br />Designed For: <br />AC <br /> <br />S <br />y <br />s <br />t <br />e <br />m <br /> <br />S <br />i <br />z <br />e <br />: <br />Ki <br />n <br />g <br />s <br />t <br />o <br />n <br /> R <br />e <br />s <br />i <br />d <br />e <br />n <br />c <br />e <br />14 <br />1 <br />0 <br /> <br />N <br /> <br />P <br />a <br />r <br />s <br />o <br />n <br />s <br /> <br />P <br />l <br />3. <br />1 <br />6 <br /> k <br />W <br />6. <br />1 <br />4 <br /> k <br />W <br />Sa <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />Signature: <br />Scale: <br />TM <br />PR_4600 <br />12/11/2024 <br />Project ID: <br />Date: <br />Designer:Skyfire Solar Design <br />CEC 705.12(B)(2)(3)(b) <br />DO NOT RELOCATE THIS <br />PV SOLAR BREAKER <br />LOCATION: MAIN PANEL DEAD FRONT <br />OVERCURRENT DEVICE <br />CEC 690.13(B) <br />PHOTOVOLTAIC SYSTEM <br />WARNING <br />COMBINER PANEL <br />DO NOT ADD LOADS <br />LOCATION: AC COMBINER PANEL <br />CEC 690.54 <br />LOCATION: AC Disconnect or Point of Interconnect if breaker <br />if breaker is used as AC Disconnect. <br />RAPID SHUTDOWN <br />SWITCH FOR SOLAR PV <br />CEC 690.56(C)(2) <br />A RAPID SHUTDOWN SWITCH SHALL HAVE A LABEL <br />LOCATED ON OR NO MORE THAN 3 FT FROM THE <br />SWITCH THAT INCLUDES THIS WORDING. THE LABEL <br />SHALL BE REFLECTIVE, WITH ALL LETTERS <br />CAPITALIZED AND HAVING A MINIMUM HEIGHT OF 3/8 <br />IN., IN WHITE ON RED BACKGROUND. <br />RATED AC OUTPUT CURRENT: <br />NOMINAL OPERATING AC VOLTAGE: <br />PHOTOVOLTAIC AC DISCONNECT <br />25.60 <br />240 <br />CEC 705.12(B)(2)(3)(b) <br />LOCATION: Rapid Shutdown <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION TO <br />SHUT DOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY. <br />SOLAR ELECTRIC <br />PV PANELS <br />CEC 690.56(C)(1)(a) <br />WARNING <br />POWER SOURCE <br />OUTPUT CONNECTION <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />LOCATION: Main Service <br />CEC 690.54 <br />LOCATION: Main Service <br />DUAL POWER SOURCE <br />WARNING <br />SECOND SOURCE IS <br />PHOTOVOLTAIC <br />CEC 690.31(G)(3) & 690.31(G)(4) <br />WARNING: PHOTOVOLTAIC POWER SOURCE <br />NO MORE THAN 10 FT. <br />CEC 690.13(B) <br />WARNING <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON BOTH THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED IN <br />THE OPEN POSITION <br />A PERMANENT PLAQUE OR DIRECTORY, DENOTING <br />ALL ELECTRIC POWER SOURCES ON OR IN THE <br />PREMISES, SHALL BE INSTALLED AT EACH SERVICE <br />EQUIPMENT LOCATION AND AT LOCATIONS OF ALL <br />ELECTRIC POWER PRODUCTION SOURCES CAPABLE <br />OF BEING INTERCONNECTED. <br />CEC 690.56(B), 690.4(D), 705.10, AND 705.12 <br />SECOND SOURCE IS PHOTOVOLTAIC SYSTEM <br />WARNING DUAL POWER SOURCE <br />LABEL NOTES <br />ONLY INSTALL APPLICABLE LABELS. Marking is required on all interior and <br />exterior PV conduit, raceways, enclosures, cable assemblies, and junction boxes to <br />alert the fire service to avoid cutting them. Marking shall be placed every 10', within 1' <br />of turns or bends, above and/or below penetrations, and at all PV combiner and <br />junction boxes. Reflective weather resistant material suitable for the environment <br />(durable adhesive materials must meet this requirement) <br />Marking Content and Format: <br />-Red Background <br />-White Lettering <br />-Minimum 3/8” Letter Height <br />-All capital letters <br />-Arial or similar font, Non bold <br />NTS <br />LA <br />B <br />E <br />L <br />S <br />PV 6 <br />CAUTION <br />POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE <br />FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: <br />- OPERATING VOLTAGE = 240V MAX CURRENT = 25.60A <br />LOCATE ON MAIN <br />SERVICE ENTRANCE <br />SECTION <br />1410 N Parsons Pl <br />Santa Ana, CA 92703 <br />FRONT <br />OF HOME <br />SOLAR PHOTOVOLTAIC <br />SERVICE POINT & <br />UTILITY METER <br />PV METER <br />AC DISCONNECT <br />SOLAR ONLY <br />LOAD CENTER <br />1410 N Parsons Pl <br />1/24/2025
The URL can be used to link to this page
Your browser does not support the video tag.