Laserfiche WebLink
DESIGN CRITERIA <br />MAX DISTRIBUTED LOAD: 3 PSF <br />SNOW LOAD: 0 PSF <br />WIND SPEED:  <br />96 MPH 3-SEC GUST. <br />FASTENERS: <br />(2) DECK ANCHORS FULLY  <br />PENETRATING THROUGH WOOD  <br />DECK <br />PAGE <br />REV: A 12/22/2025 <br />TED YAMADA <br />1925 W DEERFIELD RD, SANTA  <br />ANA, CA, 92704 <br />PROJECT NUMBER: <br />  109R-925YAMA  PR-3004737100 <br />SHEET <br />DESIGNER: <br />MEGHA S <br />CUSTOMER RESIDENCE: <br />TEL. (714) 550-6636 <br />APN: 412-531-54 <br />(415) 580-6920 ex3 <br />PV-3.0 <br />#ESTAMP#SSTAMP <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603   <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />LAYOUT <br />SOLAR MODULE <br />SNAPNRACK  <br />RACKING <br />MODULE ELEVATION DETAIL - SCALE: NTS <br />4.5" <br />ROOF INFO ATTACHMENT INFORMATION <br />Name Type Height Detail Max Landscape  <br />OC Spacing <br />Max Landscape  <br />Overhang <br />Max Portrait  <br />OC Spacing <br />Max Portrait  <br />Overhang Configuration <br />AR-01 COMP SHINGLE - UR - ULTRAFOOT  <br />[DECKANCHOR]2-Story ULTRAFOOT [ANCHOR] RAIL TO DECK SNR-DC-01507 4'-10" 0'-6" 4'-10" 0'-6" STAGGERED <br />INSTALLERS SHALL NOTIFY ENGINEER OF ANY  <br />POTENTIAL STRUCTURAL ISSUES OBSERVED  <br />PRIOR TO PROCEEDING W/ INSTALLATION. <br />ATTACHMENTS FOR THIS INSTALLATION ARE DESIGNED FOR A STANDARD  <br />WOOD FRAMED ROOF STRUCTURE FREE FROM DAMAGE, DETERIORATION,  <br />OR MODIFICATION THAT WOULD COMPROMISE ITS ORIGINAL DESIGN  <br />INTEGRITY.  INSTALLERS SHALL OBSERVE THE FRAMING FOR  <br />CONFORMANCE TO THE BELOW REQUIREMENTS AND NOTIFY THE ENGINEER  <br />OF ANY POTENTIAL STRUCTURAL ISSUES FOR GUIDANCE PRIOR TO  <br />PROCEEDING WITH INSTALLATION. <br /> :  MINIMUM 2x WOOD FRAMING (NOMINAL) FREE FROM DAMAGE,  <br />DETERIORATION, OR MODIFICATION <br />ⅱ:  FRAMING SPACING AT 24"" O.C. MAX <br />ⅲ: FASTENER SHALL BE EMBEDDED INTO COMPETENT MATERIAL <br />D1 - AR-01 - SCALE: 3/16" = 1'-0" <br />AZIM:179° <br />PITCH:23° <br />22'-7" <br />17'-1" <br />20'-1"4'-8" <br />1'-10" <br />4'-11" <br />IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12" (48" FOR  <br />TILT KITS) BOUNDARY REGION OF ANY ROOF PLANE  <br />EDGES (EXCEPT VALLEYS), <br />THEN ATTACHMENTS NEED TO BE ADDED AND  <br />OVERHANG REDUCED WITHIN THE 12" (48" FOR TILT  <br />KITS) BOUNDARY REGION ONLY AS <br />FOLLOWS: <br />PLANS TO BE REDUCED BY 50%. <br />1/5TH OF ALLOWABLE ATTACHMENT SPACING  <br />INDICATED ON PLANS. <br />20'-1"4'-8" <br />1'-10" <br />Signed: 12/22/2025