My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
301 N Broadway - Shell & Core - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Broadway
>
301 N Broadway
>
301 N Broadway - Shell & Core - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 10:51:20 AM
Creation date
2/24/2026 10:50:24 AM
Metadata
Fields
Template:
Plan
Permit Number
101120309
Full Address
301 N Broadway
Street Number
301
Street Direction
N
Street Name
Broadway
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2081
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
R08R09R10R11R12R13R14R15R16R17 <br />RF <br />RG <br />RH <br />RJ <br />RK <br />RL <br />R07R11' <br />DELAY POURSTRIP <br />PER 8 <br />R1.S5.61 <br />4'-0"4'-0" <br />32 <br />1 <br /> <br />K <br />42 <br />8 <br /> <br />K <br />53 <br />6 <br /> <br />K <br />53 <br />6 <br /> <br />K <br />58 <br />9 <br /> <br />K <br />53 <br />6 <br /> <br />K <br />48 <br />2 <br /> <br />K <br />26 <br />8 <br /> <br />K <br />29 K/FT28 K/FT <br />28 K/FT <br />35 K/FT <br />53 <br />6 <br /> <br />K <br />53 <br />6 <br /> <br />K <br />58 <br />9 <br /> <br />K <br />58 <br />9 <br /> <br />K <br />48 <br />2 <br /> <br />K <br />42 <br />8 <br /> <br />K <br />53 <br />6 <br /> <br />K <br />29 K/FT <br />29 K/FT <br />28 K/FT <br />4" <br />4" <br />7" <br />2 <br />" <br />7 <br />" <br />2" <br />7" <br />1. <br />7 <br />5 <br />" <br />4" <br />4" <br />7" <br />1 <br />" <br />7 <br />" <br />1" <br />7" <br />1" <br />4" <br />4" <br />7" <br />1 <br />" <br />4" <br />4 <br />" <br />4 <br />" <br />4" <br />4" <br />4" <br />7" <br />1 <br />" <br />4" <br />4" <br />4" <br />4" <br />4" <br />7" <br />1 <br />" <br />7 <br />" <br />4 <br />" <br />7 <br />" <br />7"7" <br />4" <br />4" <br />1" <br />4" <br />4" <br />7" <br />1 <br />" <br />7 <br />" <br />1 <br />" <br />7" <br />4" <br />4" <br />7" <br />2 <br />" <br />7 <br />" <br />1. <br />7 <br />5 <br />" <br />7" <br />4"4" <br />4" <br />4" <br />7" <br />1 <br />" <br />4" <br />4" <br />4" <br />4" <br />4" <br />4" <br />26 <br />8 <br /> <br />K <br />26 <br />8 <br /> <br />K <br />26 <br />8 <br /> <br />K <br />21 <br />4 <br /> <br />K <br />21 <br />4 <br />K <br />26 <br />8 <br />K <br />26 <br />8 <br />K <br />4. <br />5 <br />" <br />4"4" <br />4" <br />4" <br />4" <br />4" <br />16 <br />1 <br />K <br />4" <br />4" <br />1" <br />6"4" <br />4" <br />4 <br />" <br />4" <br />7" <br />4" <br />4" <br />7" <br />4" <br />4" <br />7" <br />4" <br />4" <br />7" <br />4" <br />4" <br />7" <br />4" <br />4" <br />7" <br />4" <br />4" <br />7" <br />4" <br />4" <br />7" <br />4" <br />4" <br />7" <br />4" <br />1"1"1"2"1"1"1" <br />1. <br />7 <br />5 <br />" <br />4" <br />4"5.5" 6.5"6"6" 4"2"2" 1.75"6.5"4.5"7"1.75"6.5" 4" <br />4"6.5"4"1.5"6.5" 4"2"5.5"4" <br />2" 4"4.5"6.5" <br />28 K/FT <br />28 K/FT 4"5.5" 6.5"6"6" 4"2"2" 1"6.5"4.5"6.5"2"6" 4" <br />4"6.5"4"1.5" <br />4"6.5" 3.5"4"6.5" <br />28 K/FT28 K/FT 4"5.5" 6.5"6"6" 4"2"2" 1"6.5"4.5"6.5"2"2"6"4" 6"6"2"6.5" 4" <br />28 K/FT28 K/FT 4"6.5" 6.5"4"1.75" 1.75" 1.75"6.5"4.5"6.5"2"2"6"4" 6.5"6.5"2"6.5" 4" <br />4" <br />4" <br />4" <br />4" <br />4" <br />(2) #6 x 80'-0"AT MID-DEPTH <br />2 <br />R1.S1.02.PT <br />37 <br />5 <br /> <br />K <br />16 <br />1 <br /> <br />K <br />4"4" <br />1. <br />7 <br />5 <br />" <br />1. <br />7 <br />5 <br />" <br />4"4" <br />2"4.5" 6.5"4" <br />C <br />CC <br />C <br />C <br />C <br />NOTES: <br />1. PLACE BANDED POST TENSIONING TENDONS IN BOTTOM. PLACE DISTRIBUTED POST TENSIONING ON TOP OF <br />BANDED TENDONS, UNLESS NOTED OTHERWISE. REFER TYPICAL POST TENSIONED SLAB DETAILS FOR PLACING <br />REQUIRMENTS. <br />2. POST TENSIONING ANCHORS SHALL BE LOCATED AT MID-DEPTH OF CONCRETE SLAB, UNLESS NOTED <br />OTHERWISE. SEE TYPICAL POST TENSIONING SLAB DETAILS FOR ADDITIONAL ANCHORAGE REQUIRMENTS. <br />3. REFER R1-S0.08 FOR POSTENSIONED SLAB TENDON AND REINFORCEMENT LEGEND. <br />R10R11R12R13R14 <br />RG <br />RH <br />R11' <br />58 <br />9 <br /> <br />K <br />4" <br />1 <br />. <br />7 <br />5 <br />" <br />1. <br />7 <br />5 <br />" <br />4" <br />1. <br />7 <br />5 <br />" <br />4" <br />4"4" <br />42 <br />8 <br /> <br />K <br />4" <br />42 <br />8 <br /> <br />K <br />UP <br />18" 7" 7" 7" 8"1.75" 1.75" 1.75" <br />DN <br />58 <br />9 <br /> <br />K <br />4" <br />1 <br />. <br />7 <br />5 <br />" <br />4" <br />37 <br />5 <br /> <br />K <br />4" <br />1. <br />7 <br />5 <br />" <br />4" <br />SCALE: 1/8" = 1'-0"1 LEVEL 02 POST TENSIONING PLAN <br />T: F: <br />© Gensler <br />Date Description <br />Project Name <br />Project Number <br />Description <br />Scale <br />Seal / Signature <br />2021 <br />Tel 949.863.9434 <br />Fax 949-553-1676 <br />4675 MacArthur Court <br />Suite 100 <br />Newport Beach, CA <br />92600 <br />USA <br />301 N. Broadway, Santa Ana, CA <br />707 Wilshire Blvd, Suite 4450 <br />Los Angeles, CA 90017-3618 <br />Thornton Tomasetti, Inc. <br />213.330.7700 213.330.7001 <br />3RD & BROADWAY - <br />RESIDENTIAL <br />As indicated <br />11/19/2024 3:22:57 PM <br />R1.S1.02.PT <br />LEVEL 02 POST TENSIONING PLAN <br />S21043.00 <br />SCALE: 1/8" = 1'-0"2 LEVEL 1 TO LEVEL 2 RAMP - POST TENSIONING PLAN <br />1 12.10.2021 REISSUE FOR PLAN CHECK <br />A 06.10.2022 REISSUE FOR PLAN CHECK <br />B 06.17.2024 REVISION TO PERMIT <br />C 09.27.2024 REISSUE FOR PLAN CHECK <br />1/7/25
The URL can be used to link to this page
Your browser does not support the video tag.