Laserfiche WebLink
R08R09R10R11R12R13R14R15R16R17 <br />RF <br />RG <br />RH <br />RJ <br />RK <br />RL <br />R07 <br />COLUMN KEY PLAN <br />C9 <br />C8 <br />C8 <br />C8 <br />C9 <br />C8 <br />C6AC6B <br />C3 <br />C3 <br />C6 <br />C3 <br />C3 <br />C1 <br />C6A <br />C3 <br />C3 <br />C1 C1A C1A <br />C2 C2 C2 C2 C2 C2 C2 <br />C5B C5C C5 C5 C5A C5AC5B <br />C6A <br />C4 C4 C4 <br />C1C1 C1 C1 C1 <br />C2 C2 C2 C2 C2 C2 C2 C2C <br />C3 C3 C3 <br />C4 C4 C4 <br />C3 C3 C3 <br />C5B C5A <br />C6B C6 <br />C1AC1A <br />C1A <br />C1A <br />C5A <br />C7 <br />C7 <br />C7 <br />C5B <br />C7 <br />C6AC6 <br />R11' <br />C1 <br />C2 <br />C2B <br />C2B <br />C2A <br />C2A <br />C6B C6A <br />C5A <br />C8 <br />REINFORCING BAR ARRANGEMENT <br />C5 <br />LE <br />V <br />E <br />L <br />REINFORCING BAR ARRANGEMENT <br />C6 <br />LE <br />V <br />E <br />L <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICELE <br />V <br />E <br />L <br /> <br />P <br />0 <br />1 <br />- <br />L <br />0 <br />1 <br />20" x 20" <br />12 - #7 <br />#5@5" <br />#5@4" <br />LTS <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICELE <br />V <br />E <br />L <br /> <br />0 <br />1 <br />- <br />L <br />0 <br />2 <br />24" x 24" <br />16 - #7 <br />#5@5" <br />#5@4" <br />LTS* <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICE <br />LE <br />V <br />E <br />L <br /> <br />0 <br />6 <br />- <br />0 <br />7 <br />20" x 20" <br />12 - #9 <br />#5@6" <br />#5@4" <br />LTS* <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICELE <br />V <br />E <br />L <br /> <br />P <br />0 <br />1 <br />- <br />L <br />0 <br />1 <br />20" x 30" <br />16 - #7 <br />#5@5" <br />#5@4" <br />LTS <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICE <br />LE <br />V <br />E <br />L <br /> <br />0 <br />2 <br />- <br />0 <br />6 <br />20" x 20" <br />12 - #7 <br />#5@5" <br />#5@4" <br />LTS* <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICELE <br />V <br />E <br />L <br /> <br />0 <br />1 <br />- <br />L <br />0 <br />2 <br />24" x 24" <br />16 - #7 <br />#5@5" <br />#5@4" <br />LTS* <br />20 <br />" <br />20" <br />TYP <br />1 1/2" <br />20 <br />" <br />20" <br />TYP <br />1 1/2" <br />REINFORCING BAR ARRANGEMENT <br />C7 <br />LE <br />V <br />E <br />L <br />20" <br />30 <br />" <br />TYP <br />1 1/2" <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICELE <br />V <br />E <br />L <br /> <br />P <br />0 <br />1 <br />- <br />L <br />0 <br />1 <br />20" x 30" <br />16 - #7 <br />#5@5" <br />#5@4" <br />LTS <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICE <br />LE <br />V <br />E <br />L <br /> <br />0 <br />6 <br />- <br />0 <br />8 <br />20" x 24" <br />20 - #7 <br />#5@5" <br />#5@4" <br />LTS* <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICELE <br />V <br />E <br />L <br /> <br />0 <br />1 <br />- <br />L <br />0 <br />2 <br />24" x 24" <br />16 - #7 <br />#5@5" <br />#5@4" <br />LTS* <br />20" <br />30 <br />" <br />TYP <br />1 1/2" <br />24" <br />24 <br />" <br />TYP <br />1 1/2" <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICELE <br />V <br />E <br />L <br /> <br />0 <br />8 <br />- <br />R <br />O <br />O <br />F <br />18" x 24" <br />14 - #7 <br />#5@5" <br />#5@4" <br />LTS* <br />18 <br />" <br />24" <br />TY <br />P <br />1 <br />1 <br />/ <br />2 <br />" <br />24" <br />24 <br />" <br />TYP <br />1 1/2" <br />24" <br />24 <br />" <br />TYP <br />1 1/2" <br />20" <br />20 <br />" <br />TYP <br />1 1/2" <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICELE <br />V <br />E <br />L <br /> <br />0 <br />2 <br />- <br />L <br />0 <br />6 <br />20" x 24" <br />14 - #7 <br />#5@5" <br />#5@4" <br />LTS* <br />20 <br />" <br />24" <br />TY <br />P <br />1 <br />1 <br />/ <br />2 <br />" <br />24 <br />" <br />24" <br />TY <br />P <br />1 <br />1 <br />/ <br />2 <br />" <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICELE <br />V <br />E <br />L <br /> <br />0 <br />6 <br />- <br />0 <br />6 <br />+ <br />20" x 20" <br />12 - #9 <br />#5@6" <br />#5@4" <br />LTS* <br />20 <br />" <br />20" <br />TYP <br />1 1/2" <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICE <br />LE <br />V <br />E <br />L <br /> <br />0 <br />2 <br />- <br />0 <br />6 <br />20" x 20" <br />12 - #7 <br />#5@5" <br />#5@4" <br />LTS* <br />20 <br />" <br />20" <br />TYP <br />1 1/2" <br />ST <br />R <br />E <br />N <br />G <br />T <br />H <br />8 <br />k <br />s <br />i <br /> <br />6 <br /> <br />k <br />s <br />i <br />REINFORCING BAR ARRANGEMENT <br />C5A <br />LE <br />V <br />E <br />L <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICELE <br />V <br />E <br />L <br /> <br />P <br />0 <br />1 <br />- <br />L <br />0 <br />1 <br />20" x 20" <br />12 - #7 <br />#5@5" <br />#5@4" <br />LTS <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICELE <br />V <br />E <br />L <br /> <br />0 <br />1 <br />- <br />L <br />0 <br />2 <br />24" x 24" <br />16 - #7 <br />#5@5" <br />#5@4" <br />LTS* <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICE <br />LE <br />V <br />E <br />L <br /> <br />0 <br />2 <br />- <br />0 <br />6 <br />20" x 20" <br />12 - #7 <br />#5@5" <br />#5@4" <br />LTS* <br />20 <br />" <br />20" <br />TYP <br />1 1/2" <br />24" <br />24 <br />" <br />TYP <br />1 1/2" <br />20" <br />20 <br />" <br />TYP <br />1 1/2" <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICE <br />LE <br />V <br />E <br />L <br /> <br />0 <br />6 <br />- <br />0 <br />7 <br />20" x 20" <br />12 - #7 <br />#5@5" <br />#5@4" <br />LTS* <br />20 <br />" <br />20" <br />TYP <br />1 1/2" <br />REINFORCING BAR ARRANGEMENT <br />C5B <br />LE <br />V <br />E <br />L <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICELE <br />V <br />E <br />L <br /> <br />P <br />0 <br />1 <br />- <br />L <br />0 <br />1 <br />20" x 20" <br />12 - #7 <br />#5@5" <br />#5@4" <br />LTS <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICELE <br />V <br />E <br />L <br /> <br />0 <br />1 <br />- <br />L <br />0 <br />2 <br />24" x 24" <br />16 - #7 <br />#5@5" <br />#5@4" <br />LTS* <br />24" <br />24 <br />" <br />TYP <br />1 1/2" <br />20" <br />20 <br />" <br />TYP <br />1 1/2" <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICELE <br />V <br />E <br />L <br /> <br />0 <br />2 <br />- <br />0 <br />6 <br />+ <br />20" x 20" <br />12 - #7 <br />#5@5" <br />#5@4" <br />LTS* <br />20 <br />" <br />20" <br />TYP <br />1 1/2" <br />REINFORCING BAR ARRANGEMENT <br />C6A <br />LE <br />V <br />E <br />L <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICE <br />LE <br />V <br />E <br />L <br /> <br />0 <br />6 <br />- <br />0 <br />7 <br />20" x 20" <br />12 - #7 <br />#5@5" <br />#5@4" <br />LTS* <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICELE <br />V <br />E <br />L <br /> <br />P <br />0 <br />1 <br />- <br />L <br />0 <br />1 <br />20" x 30" <br />16 - #7 <br />#5@5" <br />#5@4" <br />LTS <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICELE <br />V <br />E <br />L <br /> <br />0 <br />1 <br />- <br />L <br />0 <br />2 <br />24" x 24" <br />16 - #7 <br />#5@5" <br />#5@4" <br />LTS* <br />20 <br />" <br />20" <br />TYP <br />1 1/2" <br />20" <br />30 <br />" <br />TYP <br />1 1/2" <br />24" <br />24 <br />" <br />TYP <br />1 1/2" <br />REINFORCING BAR ARRANGEMENT <br />C6B <br />LE <br />V <br />E <br />L <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICELE <br />V <br />E <br />L <br /> <br />0 <br />2 <br />- <br />0 <br />6 <br />+ <br />20" x 20" <br />12 - #7 <br />#5@5" <br />#5@4" <br />LTS* <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICELE <br />V <br />E <br />L <br /> <br />P <br />0 <br />1 <br />- <br />L <br />0 <br />1 <br />20" x 30" <br />16 - #7 <br />#5@5" <br />#5@4" <br />LTS <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICELE <br />V <br />E <br />L <br /> <br />0 <br />1 <br />- <br />L <br />0 <br />2 <br />24" x 24" <br />16 - #7 <br />#5@5" <br />#5@4" <br />LTS* <br />20 <br />" <br />20" <br />TYP <br />1 1/2" <br />20" <br />30 <br />" <br />TYP <br />1 1/2" <br />24" <br />24 <br />" <br />TYP <br />1 1/2" <br />REINFORCING BAR ARRANGEMENT <br />C5C <br />LE <br />V <br />E <br />L <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICELE <br />V <br />E <br />L <br /> <br />P <br />0 <br />1 <br />- <br />L <br />0 <br />1 <br />20" x 20" <br />12 - #7 <br />#5@5" <br />#5@4" <br />LTS <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICELE <br />V <br />E <br />L <br /> <br />0 <br />1 <br />- <br />L <br />0 <br />2 <br />24" x 24" <br />16 - #7 <br />#5@5" <br />#5@4" <br />LTS* <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICE <br />LE <br />V <br />E <br />L <br /> <br />0 <br />6 <br />- <br />0 <br />7 <br />24" x 24" <br />16 - #9 <br />#5@6" <br />#5@4" <br />LTS* <br />20 <br />" <br />20" <br />TYP <br />1 1/2" <br />24" <br />24 <br />" <br />TYP <br />1 1/2" <br />20" <br />20 <br />" <br />TYP <br />1 1/2" <br />SIZE <br />REINF <br />TIES LOC 1 <br />TIES LOC 2 <br />SPLICE <br />LE <br />V <br />E <br />L <br /> <br />0 <br />2 <br />- <br />0 <br />6 <br />20" x 20" <br />12 - #7 <br />#5@5" <br />#5@4" <br />LTS* <br />24" <br />24 <br />" <br />TYP <br />1 1/2" <br />T: F: <br />© Gensler <br />Date Description <br />Project Name <br />Project Number <br />Description <br />Scale <br />Seal / Signature <br />2021 <br />Tel 949.863.9434 <br />Fax 949-553-1676 <br />4675 MacArthur Court <br />Suite 100 <br />Newport Beach, CA <br />92600 <br />USA <br />301 N. Broadway, Santa Ana, CA <br />707 Wilshire Blvd, Suite 4450 <br />Los Angeles, CA 90017-3618 <br />Thornton Tomasetti, Inc. <br />213.330.7700 213.330.7001 <br />3RD & BROADWAY - <br />RESIDENTIAL <br />As indicated <br />11/19/2024 3:32:03 PM <br />R1.S5.11 <br />CONCRETE COLUMN GRAPHICAL <br />SECTIONS <br />S21043.00 <br />NOTES: <br />(*) INDICATES LOCATIONS WHERE LONGITUDINAL REBAR SPLICE MUST OCCUR IN THE MIDDLE 1/2 OF THE COLUMN SPAN REFER TO 7 <br />R1.S5.20 <br />1 12.10.2021 REISSUE FOR PLAN CHECK <br />A 06.10.2022 REISSUE FOR PLAN CHECK <br />B 06.17.2024 REVISION TO PERMIT <br />1/7/25