THESE DRAWINGS REPRESENT THE POOL & SPA FEATURE FOR THIS PROJECT <br />ALL DECKING LIMITS, DRAINAGE, WALKWAYS, FENCING DESIGN, BATHROOMS <br />DESIGN, UTILITIES, AND OTHER STRUCTURES SHOWN ON THE PLAN SHALL BE <br />DOCUMENTED BY OTHER DISCIPLINES. THE CONTRACTED SCOPE OF WORK <br />REPRESENTS THE FOLLOWING: <br />SPECIFICATIONS: <br />·POOL & SPA TYPE: ELEVATED IN STRUCTURE <br />·POOL & SPA SIZE: PER DESIGN REQUIREMENTS <br />·CONSTRUCTION TYPE: PNEUMATICALLY PLACED CONCRETE <br />·WALL AND FLOOR COATING: WHITE PLASTER <br />·FILTRATION SYSTEM: HIGH RATE SAND FILTRATION SYSTEM <br />·SANITATION SYSTEM: CHEMICAL PUMPS AND TANKS, CHEMISTRY <br />CONTROLLER <br />·ACCESSORIES: LIFE SAFETY EQUIPMENT AND SIGNAGE - DESIGN PER <br />LOCAL CODE <br />·DECK EQUIPMENT: HANDRAILS, ANCHORS, ADA LIFT AS REQUIRED <br />INCLUDED IN POOL PACKAGE: <br />·INSTALL OF POOL & SPA SHELL SHELL AND PIPING. <br />·POOL & SPA INSTALLED AS A COMPLETE WORKING SYSTEM. <br />·POOL & SPA EDGE COPING EDGE WITH PROVISIONS FOR DECKING. <br />·INSTALLATION OF INTERIOR SURFACE. <br />·TILE AT BORDER OF POOL WITH DEPTH MARKINGS. <br />·COMPLETE FILTRATION AND SANITATION EQUIPMENT. <br />·ELECTRICAL PANEL WITH CHEMICAL FEED INTERLOCK PROVIDED BY G.C. <br />·INTERIOR LIGHTING TO GFCI CIRCUIT. <br />·INTERCONNECTION OF POOL PIPING TO FILTRATION SYSTEM. (Sch. 80 PVC) <br />·HAND RAILS, GRAB RAILS, DECK ANCHORS, SAFETY AND TEST EQUIPMENT. <br />ASME HEATER (NG) - GAS LINE PROVIDED BY G.C. <br />·ADA LIFT ANCHOR WITH REMOVABLE LIFT. <br />·CONNECTION OF FRESH WATER FILL PROVIDED BY G.C. (PROTECTED) TO <br />AUTOMATIC WATER LEVEL SYSTEM. <br />·RELATED PERMITTING AND INFORMATION. <br />·START-UP AND OWNER TRAINING. <br />·INITIAL CHEMICAL BATCH AND WATER BALANCING. <br />·OPERATION GUIDE MANUAL. <br />COMMON PROPERTY NAME: SANI-CHLOR - HYPOCHLORITE (BLEACH) - NaOCL <br />MATERIAL: OXIDIZER <br />CLASS: 1 <br />STORAGE AMOUNT: MAXIMUM STORAGE PER TABLE 5003.1.1(1) - 400 GALLONS <br />ON SITE STORAGE: NONE <br />USED IN CLOSED SYSTEM: 20 GALLONS USED IN CHEMICAL TANK <br />CSA REGISTRATION NO: 7681-52-9 <br />1.AMERICANS WITH DISABILITIES ACT <br />2.VIRGINIA GRAEME BAKER SAFETY ACT <br />3.2018 CAEHA - CALIFORNIA ASSOCIATION OF ENVIRONMENTAL HEALTH <br />ADMINISTRATORS <br />4.2019 CALIFORNIA BUILDING CODE STANDARDS - TITLE 24: <br />-CHAPTER 31B - PUBLIC POOLS <br />-CALIFORNIA BUILDING STANDARDS <br />-CALIFORNIA BUILDING CODE <br />-CALIFORNIA ELECTRICAL CODE <br />-CALIFORNIA MECHANICAL CODE <br />-CALIFORNIA PLUMBING CODE <br />-CALIFORNIA ENERGY CODE <br />-CALIFORNIA FIRE CODE <br />-CALIFORNIA GREEN BUILDING STANDARDS CODE <br />5.GUIDELINES SET FORTH BY THE COUNTY OF ORANGE <br />POOL & SPA SHEET INDEX <br />603.5.20 SWIMMING POOLS, SPAS, AND HOT TUBS. <br />POTABLE WATER SUPPLY TO SWIMMING POOLS, SPAS, AND HOT TUBS SHALL <br />BE PROTECTED BY AN AIR GAP OR A REDUCED PRESSURE PRINCIPLE <br />BACKFLOW PREVENTER IN ACCORDANCE WITH THE FOLLOWING: <br />(1)THE UNIT IS EQUIPPED WITH A SUBMERGED FILL LINE. <br />THE POTABLE WATER SUPPLY IS DIRECTLY CONNECTED TO THE UNIT <br />CIRCULATION SYSTEM. <br />POTABLE WATER <br />COMMON PROPERTY NAME: HYDROCHLORIC ACID - HCL <br />MATERIAL: CORROSIVE <br />CLASS: 1 <br />STORAGE AMOUNT: MAXIMUM STORAGE PER TABLE 5003.1.1(2) - 50 GALLONS <br />ON SITE STORAGE: NONE <br />USED IN CLOSED SYSTEM: 20 GALLONS USED IN CHEMICAL TANK <br />CSA REGISTRATION NO: 7647-01-0 <br />BONDING & GROUNDING <br />CODE COMPLIANCE <br />SCOPE OF WORK <br />HEATER NOTES <br />CBC ELECTRICAL NOTES <br />CBC PLUMBING NOTES <br />1.EACH FIXTURE TRAP SHALL HAVE A PROTECTING VENT SO LOCATED THAT <br />THE DEVELOPED LENGTH OF THE TRAP ARM FROM THE TRAP WEIR TO THE <br />INNER EDGE OF THE VENT SHALL BE WITHIN THE DISTANCE GIVEN IN TABLE <br />1002.2 IPC, BUT IN NO CASE LESS THAN TWO TIMES THE DIAMETER OF THE <br />TRAP ARM. <br />2.EACH PLUMBING FIXTURE THAT CONNECTS TO THE SANITARY SEWER <br />SYSTEM SHALL BE PROPERLY TRAPPED AND VENTED IN ACCORDANCE WITH <br />THE 2019 IPC. <br />3.FLOOR DRAINS OR SIMILAR TRAPS DIRECTLY CONNECTED TO THE <br />DRAINAGE SYSTEMS AND SUBJECT TO INFREQUENT USE SHALL BE <br />PROVIDED WITH AN APPROVED AUTOMATIC MEANS OF MAINTAINING THEIR <br />WATER SEALS. <br />4.BUILDING DRAIN AND VENT PIPING MATERIALS SHALL COMPLY WITH <br />SECTIONS 701.0 AND 903.0 OF THE INTERNATIONAL PLUMBING CODE. <br />5.EACH VENT SHALL RISE VERTICALLY TO A POINT NOT LESS THAN SIX (6) <br />INCHES ABOVE THE FLOOD-LEVEL RIM OF THE FIXTURE SERVED BEFORE <br />OFFSETTING HORIZONTALLY OR BEFORE CONNECTING TO ANOTHER VENT. <br />1.THE POOL HEATER SHALL: <br />A.) MEET ASME STANDARDS <br />B.) BOND BOILER PER ELECTRIC CODE <br />C.) HAVE A CODE COMPLIANT GAS TRAIN ASSEMBLY <br />D.) HAVE A NATURAL GAS APPLIANCE APPROVED BALL/SHUTOFF VALVE <br />PROVIDED BY THE BOILER INSTALLATION CONTRACTOR <br />2.IMC SECTION 1010.1: <br /> A.) THE DISCHARGE OF THE RELIEF VALVE SHALL BE PIPED TO WITHIN 18 <br />INCHES OF THE FLOOR OR TO AN OPEN RECEPTACLE (IMC 1006.1) <br />B.) NO VALVE SHALL BE PLACED BETWEEN THE SAFETY RELIEF VALVE <br />AND THE HEATER, NOR ON THE DISCHARGE PIPE BETWEEN THE SAFETY <br />RELIEF VALVE AND THE ATMOSPHERE (IMC 1006.1) <br />3.ENERGY EFFICIENCY STANDARDS SECTION <br />A.) ANY POOL OR SPA HEATING SYSTEM OR EQUIPMENT MAY BE <br />INSTALLED ONLY IF THE MANUFACTURER HAS CERTIFIED THAT THE <br />SYSTEM OR EQUIPMENT HAS THE FOLLOWING: <br />i.) THERMAL EFFICIENCY THAT COMPLIES WITH THE APPLIANCE <br />EFFICIENCY REGULATION <br />ii.) ON/OFF SWITCH MOUNTED TO OUTSIDE OF HEATER THAT <br />ALLOWS SHUTTING OFF THE HEATER WITHOUT ADJUSTING THE <br />THERMOSTAT AND INSTRUCTIONS CONSISTING OF A PERMANENT, <br />EASILY READABLE AND WEATHERPROOF PLATE OR CARD THAT <br />GIVES INSTRUCTIONS FOR THE ENERGY EFFICIENT OPERATION <br />OF THE POOL OR SPA HEATER AND FOR PROPER CARE WHEN THE <br />POOL OR SPA WATER COVER IS USED. <br />iii.) NO ELECTRIC RESISTANCE HEATING. <br />B.) INSTALLATION OF ANY POOL & SPA SYSTEM OR EQUIPMENT SHALL BE <br />INSTALLED WITH AT LEAST 36 INCHES OF PIPE BETWEEN THE FILTER AND <br />THE HEATER OR SUCTION AND RETURN LINES, OR BUILT-IN OR BUILT-UP <br />CONNECTIONS AND SHALL BE INSTALLED TO ALLOW FOR THE FUTURE <br />ADDITION OF SOLAR HEATING EQUIPMENT. <br />4.EQUIPMENT AND APPLIANCES SHALL BE INSTALLED AS REQUIRED BY THE <br />TERMS OF THEIR APPROVAL, IN ACCORDANCE WITH THE CONDITIONS OF <br />THEIR LISTING THE MANUFACTURERS INSTALLATION INSTRUCTIONS AND <br />CODE. MANUFACTURERS INSTALLATION INSTRUCTIONS SHALL BE <br />AVAILABLE ON THE JOB SITE AT THE TIME OF INSPECTION. (IMC 304.1) <br />5.VENTING FOR THE POOL HEATER SHALL BE IN ACCORDANCE WITH ALL <br />REQUIREMENTS OF THE MANUFACTURERS INSTALLATION INSTRUCTIONS <br />AND THE 2015 IMC CHAPTER 8. <br />6.AIR FOR COMBUSTION, VENTILATION AND DILUTION OF FLUE GASSES <br />SHALL BE PROVIDED FOR THE POOL HEATER ENCLOSURE IN <br />ACCORDANCE WITH THE MANUFACTURES INSTALLATION INSTRUCTIONS <br />AND THE 2015 INTERNATIONAL FUEL AND GAS CODE. <br />1.ALL ELECTRICAL WORK SHALL COMPLY WITH FOLLOW: 2019 CEC - <br />ARTICLE 680 - SWIMMING POOL INSTALLATIONS - SEE: ELECTRICAL <br />SHEETS FOR ADDITIONAL NOTES: <br />- 680.7 - CORD-AND-PLUG-CONNECTED EQUIPMENT <br />- 680.8 - OVERHEAD CONDUCTOR CLEARANCE <br />- 680.9 - ELECTRIC WATER HEATER <br />- 680.10 - UNDERGROUND WIRING <br />- 680.11 - EQUIPMENT ROOMS AND PITS <br />- 680.12 - MAINTENANCE DISCONNECTING MEANS <br />- 680.21 - MOTORS <br />- 680.22 - AREA LIGHTING, RECEPTACLES AND EQUIPMENT <br />- 680.23 - UNDERWATER LUMINARIES <br />- 680.24 - JUNCTION BOX, TRANSFORMER, OR GFCI ENCLOSURE <br />- 680.25 - FEEDERS <br />- 680.26 - EQUIPOTENTIAL BONDING <br />- 680.27 - SPECIALIZED EQUIPMENT <br />- ANY ADDITIONAL STATE AND LOCAL REQUIREMENTS <br />CHEMICALS & STORAGE <br />APPROVAL STAMP: <br />CONTACT INFORMATION <br />POOL & SPA DATA <br />1.[POOL] <br />PERIMETER:116'-0" LF. <br />SURFACE AREA:616 SQFT. <br />APPROXIMATE VOLUME:15,505 GALLONS <br />MINIMUM TURN OVER:6 HRS <br />MINIMUM FLOW RATE:43 GPM <br />DESIGNED FLOW RATE:75 GPM @ 60 TDH <br />OCCUPANCY LOAD:30 PERSONS PER CBC(POSTED) <br />GUTTER SURGE:698 GAL. (616 MIN.) <br />2.[SPA] <br />PERIMETER:56'-0" LF. <br />SURFACE AREA:196 SQFT. <br />APPROXIMATE VOLUME:3,908 GALLONS <br />MINIMUM TURN OVER:1/2 HRS <br />MINIMUM FLOW RATE:130 GPM <br />DESIGNED FLOW RATE:150 GPM @ 60 TDH <br />OCCUPANCY LOAD:24 PERSONS (POSTED) <br />BOOSTER FLOW RATE:155 GPM <br />GUTTER SURGE:270 GAL. (196 MIN.) <br />11B-1009 SWIMMING POOLS, WADING POOLS, AND SPAS <br />11B-1009.1 GENERAL. WHERE PROVIDED, POOL LIFTS, SLOPED ENTRIES, <br />TRANSFER WALLS, TRANSFER SYSTEMS, AND POOL STAIRS SHALL COMPLY <br />WITH 11B-1009. <br />11B-1009.2 POOL LIFTS. POOL LIFTS SHALL COMPLY WITH 11B-1009.2. <br />11B-1009.2.1 POOL LIFT LOCATION. POOL LIFTS SHALL BE LOCATED WHERE <br />THE WATER LEVEL IS 36 INCHES MINIMUM AND 48 INCHES MAXIMUM. <br />EXCEPTIONS: <br />1. WHERE THE ENTIRE POOL DEPTH IS GREATER THAN 48 INCHES, <br />COMPLIANCE WITH 11B-1009.2.1 SHALL NOT BE REQUIRED. <br />2. WHERE MULTIPLE POOL LIFT LOCATIONS ARE PROVIDED, NO MORE THAN <br />ONE POOL LIFT SHALL BE REQUIRED TO BE LOCATED IN AN AREA WHERE THE <br />WATER LEVEL IS 48 INCHES MAXIMUM. <br />3. WHERE THE WATER DEPTH OF THE ENTIRE SWIMMING POOL, WADING <br />POOL OR SPA IS LESS THAN 36 INCHES, POOL LIFTS SHALL BE LOCATED <br />WHERE THE WATER LEVEL IS LESS THAN 36 INCHES. <br />11B-1009.2.2 SEAT LOCATION. IN THE RAISED POSITION, THE CENTERLINE OF <br />THE SEAT SHALL BE LOCATED OVER THE DECK AND 16 INCHES MINIMUM <br />FROM THE EDGE OF THE POOL. THE DECK SURFACE BETWEEN THE <br />CENTERLINE OF THE SEAT AND THE POOL EDGE SHALL HAVE A SLOPE NOT <br />STEEPER THAN 1:48. <br />11B-1009.2.3 CLEAR DECK SPACE. ON THE SIDE OF THE SEAT OPPOSITE THE <br />WATER, A CLEAR DECK SPACE SHALL BE PROVIDED PARALLEL WITH THE <br />SEAT. THE SPACE SHALL BE 36 INCHES WIDE MINIMUM AND SHALL EXTEND <br />FORWARD 48 INCHES MINIMUM FROM A LINE LOCATED 12 INCHES BEHIND <br />THE REAR EDGE OF THE SEAT. THE CLEAR DECK SPACE SHALL HAVE A <br />SLOPE NOT STEEPER THAN 1:48. <br />11B-1009.2.4 SEAT . THE SEAT SHALL BE RIGID AND SHALL HAVE A BACK <br />SUPPORT THAT IS AT LEAST 12 INCHES TALL. THE HEIGHT OF THE LIFT SEAT <br />SHALL BE DESIGNED TO ALLOW A STOP AT 17 INCHES MINIMUM TO 19 INCHES <br />MAXIMUM MEASURED FROM THE DECK TO THE TOP OF THE SEAT SURFACE <br />WHEN IN THE RAISED (LOAD) POSITION. THE SEAT SHALL HAVE A RESTRAINT <br />FOR THE USE OF THE OCCUPANT WITH OPERABLE PARTS COMPLYING WITH <br />11B-309. <br />11B-1009.2.5 SEAT WIDTH. THE SEAT SHALL BE 16 INCHES WIDE MINIMUM. <br />11B-1009.2.6 FOOTRESTS AND ARMRESTS. . FOOTRESTS SHALL BE PROVIDED <br />AND SHALL MOVE WITH THE SEAT. THE SEAT SHALL HAVE TWO ARMRESTS. <br />THE ARMREST POSITIONED OPPOSITE THE WATER SHALL BE REMOVABLE OR <br />SHALL FOLD CLEAR OF THE SEAT WHEN THE SEAT IS IN THE RAISED <br />POSITION. <br />EXCEPTION: FOOTRESTS SHALL NOT BE REQUIRED ON POOL LIFTS PROVIDED <br />IN SPAS. <br />11B-1009.2.7 OPERATION. THE LIFT SHALL BE CAPABLE OF UNASSISTED <br />OPERATION FROM BOTH THE DECK AND WATER LEVELS. CONTROLS AND <br />OPERATING MECHANISMS SHALL BE UNOBSTRUCTED WHEN THE LIFT IS IN <br />USE AND SHALL COMPLY WITH 11B-309.4 (OPERATION). THE LIFT SHALL BE <br />STABLE AND NOT PERMIT UNINTENDED MOVEMENT WHEN A PERSON IS <br />GETTING INTO OR OUT OF THE SEAT. <br />11B-1009.2.8 SUBMERGED DEPTH. THE LIFT SHALL BE DESIGNED SO THAT THE <br />SEAT WILL SUBMERGE TO A WATER DEPTH OF 18 INCHES MINIMUM BELOW <br />THE STATIONARY WATER LEVEL. <br />11B-1009.2.9 LIFTING CAPACITY. SINGLE PERSON POOL LIFTS SHALL HAVE A <br />WEIGHT CAPACITY OF 300 POUNDS MINIMUM AND BE CAPABLE OF <br />SUSTAINING A STATIC LOAD OF AT LEAST ONE AND A HALF TIMES THE RATED <br />LOAD. <br />1. R1-SP-001 POOL & SPA PLAN COVER <br />2. R1-SP-002 POOL & SPA SITE PLAN <br />3. R1-SP-003 POOL & SPA CUT SHEETS <br />4. R1-SP-004 POOL & SPA CUT SHEETS <br />5. R1-SP-005 POOL & SPA CUT SHEETS <br />6. R1-SP-006 POOL & SPA CUT SHEETS <br />7. R1-SP-007 POOL & SPA CUT SHEETS <br />8. R1-SP-008 POOL & SPA CUT SHEETS <br />9. R1-SP-009 POOL & SPA CUT SHEETS <br />10. R1-SP-101 POOL & SPA PLAN <br />11. R1-SP-102 POOL & SPA EQUIPMENT PLAN <br />12. R1-SP-103 POOL & SPA PLUMBING PLAN <br />13. R1-SP-301 POOL & SPA SECTIONS <br />14. R1-SP-501 POOL & SPA DETAILS <br />15. R1-SP-502 POOL & SPA DETAILS <br />16. R1-SP-503 POOL & SPA DETAILS <br />17. R1-SP-504 POOL & SPA DETAILS <br />18. R1-SP-505 POOL & SPA DETAILS <br />19. R1-SP-506 INTELLICENTER SCHEMATIC <br />© Gensler <br />Date Description <br />Project Name <br />Project Number <br />Description <br />Scale <br />Seal / Signature <br />2021 <br />Tel 949.863.9434 <br />Fax 949-553-1676 <br />4675 MacArthur Court <br />Suite 100 <br />Newport Beach, CA <br />92600 <br />USA <br />BI <br />M <br /> <br />3 <br />6 <br />0 <br />: <br />/ <br />/ <br />0 <br />0 <br />7 <br />. <br />3 <br />7 <br />5 <br />7 <br />. <br />0 <br />0 <br />0 <br /> <br />- <br /> <br />C <br />a <br />r <br />i <br />b <br />o <br />u <br /> <br />I <br />n <br />d <br />u <br />s <br />t <br />r <br />i <br />e <br />s <br /> <br />- <br /> <br />3 <br />r <br />d <br /> <br />& <br /> <br />B <br />r <br />o <br />a <br />d <br />w <br />a <br />y <br />/ <br />3 <br />R <br />D <br />- <br />B <br />_ <br />A <br />R <br />C <br />H <br />_ <br />W <br />E <br />S <br />T <br />_ <br />R <br />2 <br />0 <br />. <br />r <br />v <br />t <br />07.3757.000 <br />3rd & Broadway <br />301 N. Broadway, Santa Ana, CA <br />09/21/2021 Issue for Plan Check <br />A 12/10/2021 Reissue for Plan Check <br />B 07/11/2022 Reissue for Plan Check <br />C 06/17/2024 REVISION TO PERMIT <br />AQUA DESIGN INTERNATIONAL <br />7534 N. LA CHOLLA BLVD. <br />TUCSON, AZ 85741 <br />OFFICE: 520-219-8929 <br />CONTACT: ADEN ACKLIN <br />QUADESIGN <br />INTERNATIONAL <br />R <br />AMMTEC CONSULTANTS <br />2447 WEST 12TH STREET SUITE #1 <br />TEMPE, AZ 85281 <br />OFFICE: 480-972-9696 <br />CONTACT: ALAN MONEY - P.E. <br />R1-SP-001 <br />POOL & SPA PLAN COVER <br />COMMON PROPERTY NAME: EZ POOL PRO <br />MATERIAL: WATER CLARIFIER <br />CLASS: N/A <br />STORAGE AMOUNT: MAXIMUM STORAGE PER TABLE 5003.1.1(2) 400 GALLONS <br />ON SITE STORAGE: (2) 40 LB. SEALED TUBS <br />USED IN CLOSED SYSTEM: 30 GALLONS USED IN DOUBLE CHEMICAL TANK <br />CSA REGISTRATION NO: N/A - CERTIFIED TO NSF/ANSI STANDARD 50. <br />COMMON PROPERTY NAME: REVIVE PRO <br />MATERIAL: WATER CLARIFIER <br />CLASS: N/A <br />STORAGE AMOUNT: MAXIMUM STORAGE PER TABLE 5003.1.1(2) 400 GALLONS <br />ON SITE STORAGE: (2) 5 GAL. SEALED TUBS <br />USED IN CLOSED SYSTEM: 10 GALLONS USED IN DOUBLE CHEMICAL TANK <br />CSA REGISTRATION NO: N/A - CERTIFIED TO NSF/ANSI STANDARD 50 <br />1.PRODUCT SUBMITTAL: <br />POOL CONTRACTOR TO INCLUDE MANUFACTURER'S DATA, <br />INSTALLATION INSTRUCTIONS AND GENERAL RECOMMENDATIONS FOR <br />EACH SPECIFIED PRODUCT. <br />2.SHOP DRAWING SUBMITTAL: <br />SHOP DRAWINGS OF EACH ITEM SPECIFIED SHOWING <br />LAYOUT,PROFILES, METHODS OF JOINING AND ANCHORAGE DETAILS <br />3.SUBMITTAL FORM: <br />USE SUBMITTAL FORM AS A COVER PAGE FOR EACH PRODUCT AND <br />SHOP DRAWING. SEE SPECIFICATIONS FOR SUBMITTAL FORM. <br />SUBMITTALS <br />1.INSPECTIONS AS REQUIRED BY THE COUNTY OF ORANGE: <br />- PLUMBING INSTALLATION. <br />- PRE-DECK. <br />- PRE-INTERIOR SURFACE & DECK. <br /> - AT THE COMPLETION OF CONSTRUCTION AND ANY OTHER <br />INSPECTIONS THAT MAY BE REQUIRED BY THE COUNTY OF LOS <br />ANGELES NO SPA SHALL BE OPENED TO THE PUBLIC WITHOUT WRITTEN <br />APPROVAL OF THE BUILDING AND HEALTH DEPARTMENT. <br />2.THE SPECIAL INSPECTIONS IDENTIFIED ON PLANS ARE, IN ADDITION TO, <br />AND NOT A SUBSTITUTE FOR, THOSE INSPECTIONS REQUIRED TO BE <br />PERFORMED BY A CITY BUILDING INSPECTOR. <br />ENCLOSURE NOTES <br />2019 CALIFORNIA BUILDING CODE STANDARDS - TITLE 24: <br />-CHAPTER 31B - PUBLIC POOLS: <br />3119B.1 ENCLOSURE. THE POOL SHALL BE ENCLOSED BY ONE OR A <br />COMBINATION OF THE FOLLOWING: A FENCE, PORTION OF A BUILDING, <br />WALL, OR OTHER APPROVED DURABLE ENCLOSURE. DOORS, WINDOWS, <br />GATES OF LIVING UNITS OR ASSOCIATED PRIVATE PREMISES SHALL NOT <br />BE PERMITTED AS PART OF THE POOL ENCLOSURE. THE ENCLOSURE, <br />DOORS AND GATES SHALL MEET ALL OF THE FOLLOWING <br />SPECIFICATIONS: <br />4.THE ENCLOSURE SHALL HAVE A MINIMUM EFFECTIVE PERPENDICULAR <br />HEIGHT OF 5 FEET (1524 MM) AS MEASURED FROM THE OUTSIDE AS <br />DEPICTED IN FIGURE 31B-4; AND <br />5.OPENINGS, HOLES OR GAPS IN THE ENCLOSURE, DOORS AND/OR <br />GATES SHALL NOT ALLOW THE PASSAGE OF A 4-INCH (102 MM) <br />DIAMETER SPHERE. THE ENCLOSURE SHALL BE CONSTRUCTED OVER <br />A HARD AND PERMANENT MATERIAL EQUIVALENT TO CONCRETE; AND <br />6.THE ENCLOSURE SHALL BE DESIGNED AND CONSTRUCTED SO THAT IT <br />CANNOT BE READILY CLIMBED BY SMALL CHILDREN. HORIZONTAL AND <br />DIAGONAL MEMBER DESIGNS WHICH MIGHT SERVE AS A LADDER FOR <br />SMALL CHILDREN ARE PROHIBITED. HORIZONTAL MEMBERS SHALL BE <br />SPACED AT LEAST 48 INCHES (1219 MM) APART. NO PLANTERS OR <br />OTHER STRUCTURES THAT CAN BE CLIMBED SHALL BE PERMITTED <br />WITHIN 5 FEET (1524 MM) OF THE OUTSIDE OF THE POOL ENCLOSURE <br />OR WITHIN A 5 FOOT (1524 MM) ARC AS DEPICTED IN FIGURE 31B-5. THE <br />AREA 5 FEET (1524 MM) OUTSIDE OF THE POOL ENCLOSURE SHALL BE <br />A COMMON AREA OPEN TO THE PUBLIC; AND <br />7.CHAIN LINK MAY BE USED, PROVIDED THAT THE OPENINGS ARE NOT <br />GREATER THAN 13/4 INCHES (44 MM) MEASURED HORIZONTALLY. <br />3119B.2 GATES. GATES AND DOORS OPENING INTO THE POOL ENCLOSURE <br />ALSO SHALL MEET THE FOLLOWING SPECIFICATIONS: <br />1.GATES AND DOORS SHALL BE EQUIPPED WITH SELF-CLOSING AND <br />SELF-LATCHING DEVICES. THE SELF-LATCHING DEVICE SHALL KEEP <br />THE GATE OR DOOR SECURELY CLOSED. GATES AND DOORS SHALL <br />OPEN OUTWARDLY AWAY FROM THE POOL EXCEPT WHERE <br />OTHERWISE PROHIBITED BY LAW. HAND ACTIVATED DOOR OR GATE <br />OPENING HARDWARE SHALL BE LOCATED AT A HEIGHT NO LOWER <br />THAN 42 INCHES (1067 MM) BUT NO HIGHER THAN 44 INCHES (1179 MM) <br />ABOVE THE DECK OR WALKWAY; AND <br />2.GATES AND DOORS SHALL BE CAPABLE OF BEING LOCKED DURING <br />TIMES WHEN THE POOL IS CLOSED. EXIT DOORS WHICH COMPLY WITH <br />CHAPTER 10, TITLE 24, CALIFORNIA CODE OF REGULATIONS SHALL BE <br />CONSIDERED AS MEETING THESE REQUIREMENTS; AND <br />3.THE POOL ENCLOSURE SHALL HAVE AT LEAST ONE MEANS OF EGRESS <br />WITHOUT A KEY FOR EMERGENCY PURPOSES. UNLESS ALL GATES OR <br />DOORS ARE SO EQUIPPED, THOSE GATES AND/OR DOORS WHICH WILL <br />ALLOW EGRESS WITHOUT A KEY SHALL HAVE A SIGN IN LETTERS AT <br />LEAST 4 INCHES (102 MM) HIGH STATING EMERGENCY EXIT; AND <br />4.THE ENCLOSURE SHALL BE CONSTRUCTED SO THAT ALL PERSONS <br />WILL BE REQUIRED TO PASS THROUGH COMMON POOL ENCLOSURE <br />GATES OR DOORS IN ORDER TO GAIN ACCESS TO THE POOL AREA. ALL <br />GATES AND DOORS EXITING THE POOL AREA SHALL OPEN INTO A <br />PUBLIC AREA OR A WALKWAY ACCESSIBLE BY ALL POOL PATRONS. <br />1.ALL GROUNDING SHALL BE COMPLETED IN ACCORDANCE WITH <br />NATIONAL ELECTRIC CODE (NEC) AND THE LOCAL AUTHORITY HAVING <br />JURISDICTION. <br />2.THESE PLANS ARE DIAGRAMMATIC AND MAY NOTE REPRESENT THE <br />FINAL LOCATIONS OF THE EQUIPMENT. THE POOL AND FOUNTAIN <br />CONTRACTORS SHALL COORDINATE ALL GROUNDING REQUIREMENTS <br />AND EQUIPMENT ELECTRICAL CONNECTIONS WITH ALL OTHER WORK <br />TO BE COMPLETED WITH CONSIDERED FIELD CONDITIONS. <br />3.THE GROUNDING GRID TO BE INSTALLED WITHIN THE POOL AND <br />FOUNTAIN ASSEMBLIES SHALL BE INSTALLED WITH A MINIMUM OF BARE <br />#8 GROUND WIRE (99% PURE COPPER) AND INSTALLATION IS TO BE <br />COORDINATED WITH FINAL FEATURE CONSTRUCTION. <br />4.GROUNDING GRID SHALL BE INSTALLED A MINIMUM OF 1 METER THE <br />POOL AND FOUNTAIN EDGES IN ACCORDANCE WITH NEC. <br />5.ALL GROUNDING CONNECTIONS SHALL BE CAD-WELDED OR AS <br />OTHERWISE REQUIRED, CAD WELDING SHALL BE COPPER TO COPPER <br />WITH 6% SILVER FOR DUCTILITY. <br />6.PROVIDE #8 BARE COPPER WIRE SPACED AT 300MM APART FOR ENTIRE <br />LENGTH OF BONDING GRID, COPPER WELD AT EACH JOINT. PROVIDE #8 <br />COPPER GROUNDING CONDUCTOR FROM LIGHTS, RAILS, AND OTHER <br />REQUIRED POOL ACCESSORIES PER POOL BONDING DIAGRAM DETAIL. <br />GENERAL NOTES <br />WATER CHEMISTRY: <br />FREE AVAILABLE CHLORINE 1.0 - 3.0 ppm <br />COMBINED CHLORINE N/A <br />POTENTIAL HYDROGEN (pH)7.4 - 7.6 ppm <br />SALT CONCENTRATION N/A <br />TOTAL ALKALINITY 80 - 100 ppm <br />TDS 1,500 ppm max. <br />CALCIUM HARDNESS 250 ppm max. <br />CYANURIC ACID 20 ppm <br />ORP / HHR 700 - 780 mV <br />TEMPERATURES 82° (POOL) & 102° (SPA) <br />ACCESSIBILITY NOTES <br />23.THE OWNER SHALL KEEP DAILY RECORD FOR THE POOL SANITATION <br />AND pH READING PER COUNTY REQUIREMENTS. <br />24. ALL PIPING IN THE EQUIPMENT ROOM MUST BE PERMANENTLY MARKED <br />WITH DIRECTIONAL ARROWS AND IDENTIFIED AS TO THE ORIGIN OF <br />USE, E.G., GUTTER, MAIN DRAIN, ETC. <br />PIPING COLOR CODE: <br />FRESH WATER - BLUE (TO CHECK VALVE) <br />BACKWASH - BLACK <br />INFLUENT - YELLOW <br /> RE-CIRCULATION SYSTEM - GREEN <br />1.ALL EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER'S <br />INSTRUCTIONS. <br />2.ANY CHANGES IN CONSTRUCTION PLANS OR EQUIPMENT MUST BE <br />APPROVED BY THE ORANGE HEALTH DEPARTMENT. CHANGES MAY <br />REQUIRE ADDITIONAL PLAN CHECK FEES AND RE-SUBMITTAL. <br />3.POOL PLAN APPROVAL DOES NOT AUTHORIZE THE VIOLATION OF ANY <br />LAW, ORDINANCE, OR REGULATION AND FINAL APPROVAL IS SUBJECT <br />TO FIELD INSPECTION AND EVALUATION. <br />4.MINIMUM OF 6 FOOT WIDE, CONTINUOUS, SLIP-RESISTANT, <br />NON-ABRASIVE DECK AREA OF CONCRETE OR CONCRETE LIKE <br />MATERIAL MUST BE PROVIDED FLUSH WITH THE TOP OF THE POOL AND <br />EXTENDED COMPLETELY AROUND. <br />5.THE REQUIRED DECKING AROUND THE POOL MUST BE FREE OF ALL <br />POSTS, COLUMNS, OR OTHER OBSTRUCTIONS AND EXTEND AT LEAST 4 <br />FEET BEHIND ANY PERMANENT HANDICAP EQUIPMENT. <br />6.ALL PARTS OF THE DECK MUST DRAIN NATURALLY OR TO FLOOR <br />DRAINS AT A SLOPE BETWEEN 1% AND 2% WITH NO ACCUMULATIONS <br />OF WATER. SPACE BETWEEN THE COPING AND THE DECK MUST BE <br />SEALED WITH AN APPROPRIATE CAULKING. <br />7.AUTOMATIC CHLORINATOR IS REQUIRED WHICH IS CAPABLE OF <br />SUPPLYING NOT LESS THAN THE EQUIVALENT OF 3 POUNDS OF <br />CHLORINE PER DAY PER 10,000 GALLONS POOL WATER CAPACITY. <br />8.ADEQUATE NUMBER OF HOSE BIBBS ARE REQUIRED IN THE POOL AREA <br />IN SUFFICIENT NUMBERS TO ALLOW A 75 FOOT HOSE TO REACH ALL <br />AREAS OF THE POOL DESK. HOSE BIBB IS REQUIRED IN THE <br />EQUIPMENT AREA. EACH HOSE BIBB MUST BE PROTECTED BY AN <br />APPROVED BACKFLOW DEVICE. <br />9.PERFORM A HYDROSTATIC TEST TO 35 PSI (3.5KG/CM2) FOR 30 <br />MINUTES AND KEEP A MINIMUM OF 25 PSI (1.75KG/CM2) ON SYSTEM <br />UNTIL AFTER DECK PHASE. <br />10.PRESSURE GAUGES SHALL BE BE INSTALLED ON THE INLET AND <br />OUTLET OF THE EACH FILTER SYSTEM AND LOCATED WHERE THEY CAN <br />BE EASILY READ. <br />11.VACUUM GAUGES SHALL BE INSTALLED ON THE INLET TO EACH PUMP <br />AND INSTALLED IN WHERE THEY CAN BE EASILY READ. <br />12.PIPE SLEEVING AND PENETRATIONS THROUGH VAULT STRUCTURE <br />SHALL BE SLEEVED PER THE LINK SEAL REQUIREMENTS THROUGH <br />WALLS. COORDINATE WITH ALL TRADES. PER IPC, SLEEVING: ANNULAR <br />SPACES SHALL BE FILLED OR TIGHTLY CAULKED. <br />13.THE PIPING INSTALLATION IN EACH EQUIPMENT ROOM, IPC SHALL BE <br />SUPPORTED IN ACCORDANCE WITH TABLE 308.5 IN THE IPC. <br />CONTRACTOR SHALL SUBMIT SUPPORT SYSTEM DESIGN TO BEFORE <br />START OF THIS WORK. <br />14.POTABLE WATER SUPPLY SYSTEMS SHALL BE DESIGNED, INSTALLED <br />AND MAINTAINED SO AS TO PREVENT CONTAMINATION FROM <br />NONPOTABLE LIQUIDS, SOLIDS OR GASES BEING INTRODUCED INTO <br />THE POTABLE WATER SUPPLY THROUGH CROSS-CONNECTIONS OR <br />ANY OTHER PIPING CONNECTIONS TO THE SYSTEM. MEANS OF <br />PROTECTION AGAINST BACKFLOW IN THE POTABLE WATER SUPPLY <br />SHALL BE PROVIDED THROUGH AN AIR GAP COMPLYING WITH ASME <br />A112.1.2 INTERNATIONAL PLUMBING CODE. <br />15.CARTRIDGE FILTER CLEANING AND DRAINING WATER SHALL BE <br />DISCHARGED TO THE SANITARY, OR INTO AN APPROVED DISPOSAL <br />SYSTEM APPROVED BY THE STATE OR LOCAL AUTHORITY. <br />16.REINFORCING STEEL OF ALL AQUATIC BODY'S SHALL BE BONDED WITH <br />A #8 COPPER WIRE TIED BOND INTO THE MECHANICAL SYSTEM FOR <br />EACH BODY OF WATER. EACH MECHANICAL SYSTEM SHALL THEN BE <br />BONDED TO THE ELECTRIC PANEL THAT SUPPLIES POWER TO THAT <br />FEATURE. FOLLOW USA NATIONAL ELECTRIC CODE FOR BONDING GRID <br />AROUND PERIMETER OF STRUCTURE. SEE: SHEET SP-503, DETAIL 5. <br />17.POOL UNDERWATER LIGHTING SHALL BE A MINIMUM OF .5 WATTS PER <br />SQ FT OF SURFACE AREA. <br />18.POOL SHALL BE PROVIDED WITH LIFE SAVING EQUIPMENT AND SHALL <br />BE VISUALLY CONSPICUOUS AND CONVENIENTLY LOCATED AT ALL <br />TIMES. SWIMMING POOL ACCESSORY POLE NOT LESS THAN 12 FEET IN <br />LENGTH AND INCLUDING A BODY HOOK SHALL BE PROVIDED. <br />19.DEPTH MARKERS OF CONTRASTING COLOR ARE REQUIRED ON BOTH <br />SIDES, AT THE MINIMUM AND MAXIMUM DEPTHS, AT THE BREAK AT 4 ½ <br />FT. AND BOTH ENDS OF THE POOL. PERMANENT DEPTH MARKERS ARE <br />REQUIRED ON THE POOL DECK, CORRESPONDING TO EVERY DEPTH <br />MARKER ON THE WALL. ALL DEPTH MARKERS MUST BE MARKED WITH <br />THE LETTERS FEET OR FT. AND INCHES OR IN. PAINTED LETTERS ARE <br />NOT PERMITTED. DEPTH MARKERS MUST BE AT LEAST 4 INCHES IN <br />HEIGHT AND MUST BE POSITIONED TO INDICATE THE WATER DEPTH <br />ACCURATE TO THE NEAREST 6 INCHES AS MEASURED FROM THE POOL <br />FLOOR TO THE MIDDLE OF THE SKIMMER OPENING. <br />20.BARRIERS SHALL BE PROVIDED TO MEET LOCAL CODES.SEE: <br />ARCHITECTURAL SHEETS. <br />21.USING THE PUMP BYPASS IS RECOMMENDED PROCESS TO TAKE POOL <br />WATER BACK TO OPERATIONAL LEVELS, IN THE EVENT THE POOL <br />SHOULD EVER EXPERIENCE HIGH WATER LEVELS OR AN OVERFLOW <br />FROM EXCESSIVE RAIN FALL. <br />22.THROWING ROPE ATTACHED TO RING BUOY OR SIMILAR FLOTATION <br />DEVICE SHALL BE PROVIDED. THE ROPE SHALL BE NOT LESS THAN ¼ <br />INCH IN DIAMETER AND SHALL HAVE A LENGTH OF NOT LESS THAN 1 ½ <br />TIMES THE MAXIMUM WIDTH OF THE POOL OR 50 FEET, WHICHEVER IS <br />LESS. A RING BUOY SHALL HAVE AN OUTSIDE DIAMETER IS NOT LESS <br />THAN 15 INCHES. <br />GENERAL OPERATIONS: <br />1.POOL PIPE ROUTING IS FOR DIAGRAM ONLY. THE POOL CONTRACTOR AND G.C. SHALL <br />COORDINATE ROUTING LOCATIONS WITH SUPPORT SYSTEM LAYOUT. THE POOL <br />CONTRACTOR SHALL PROVIDE PIPE MOUNTING, SUPPORT, EXPANSION JOINTS IF <br />NEEDED AND INSULATION. THE POOL CONTRACTOR SHALL PROVIDE A SHOP <br />DRAWING FOR THESE ITEMS TO THE G.C., ARCHITECT AND AQUATIC CONSULTANT. <br />2.THE PUMP AND HEATER EQUIPMENT SHALL BE SET ON A 4" MIN. CONCRETE <br />HOUSE-KEEPING PAD THAT POSITIVELY SLOPES TOWARD THE FLOOR DRAINAGE <br />SYSTEM. <br />3.THE HEATER SHALL BE PROVIDED WITH A SYSTEM THAT DETECTS AND MONITORS <br />CARBON MONOXIDE IN THE EQUIPMENT ROOM. <br />4.ALL CIRCULATION PUMPS SHALL BE SET WITH THE PROVIDED VALVES AND FLOW <br />METERS AT START FOR THE FLOW RATES LISTED ON POOL PLANS AND BACKWASH <br />RATES FOR THE FILTERS. <br />INSPECTIONS <br />TITLE 24 REQUIRMENTS <br />1.AT LEAST 36 INCHES OF PIPE SHALL BE INSTALLED BETWEEN THE FILTER <br />AND THE HEATER OR DEDICATED SUCTION AND RETURN LINES, OR <br />BUILT-IN OR BUILT-UP CONNECTIONS SHALL BE INSTALLED TO ALLOW <br />FOR THE FUTURE ADDITION OF SOLAR HEATING EQUIPMENT." <br />2.A COVER FOR OUTDOOR POOLS OR OUTDOOR SPAS THAT HAVE A HEAT <br />PUMP OR GAS HEATER SHALL BE PROVIDED." <br />3.A TIME SWITCH OR SIMILAR CONTROL MECHANISM SHALL BE INSTALLED <br />AS PART OF A POOL WATER CIRCULATION CONTROL SYSTEM THAT WILL <br />ALLOW ALL PUMPS TO BE SET OR PROGRAMMED TO RUN ONLY DURING <br />THE OFF-PEAK ELECTRIC DEMAND PERIOD AND FOR THE MINIMUM TIME <br />NECESSARY TO MAINTAIN THE WATER IN THE CONDITION REQUIRED BYAPPLICABLE PUBLIC HEALTH STANDARDS." <br />1.PROVIDE WATERPROOFING SYSTEM AQURON CPSP BY AQURON <br />CORPORATION INTERNATIONAL (WWW.AQURON.COM) BETWEEN <br />INTERIOR COATING AND SHOTCRETE PER PRODUCT INSTRUCTIONS. <br />2.SEAL ALL PENETRATIONS THROUGH SHOTCRETE SHELL WITH <br />AQUABOND UW-5000 EPOXY AT CONNECTION OF PVC TO SHOTCRETE. <br />WATERPROOFING NOTES <br />CONCRETE & REBAR NOTES <br />SPECIFICATIONS <br />A.MATERIALS <br />1.GEO-SYNTHETIC FILL: INSULFOAM GF SHALL CONFORM TO ASTM D 6817 <br />AND MAY BE FABRICATED USING MATERIAL WITH RECYCLED CONTENT. <br />BLOCKS SHALL HAVE A HEIGHT OF AT LEAST 36 INCHES (.91 M), A WIDTH <br />OF AT LEAST 48 INCHES (1.22 M), AND LENGTH OF AT LEAST 96 INCHES <br />(2.44 M). BLOCKS SHALL BE WITHIN TOLERANCES OF 0.5 PERCENT OF <br />RESPECTIVE HEIGHT, WIDTH AND LENGTH DIMENSIONS. ADDITIONAL <br />FIELD AND/OR SHOP TRIMMING AND CUTTING SHALL BE REQUIRED AS <br />NECESSITATED BY THE GEOMETRY OF THE FILL BEING CONSTRUCTED. <br />a.TYPE EPS29: PHYSICAL PROPERTIES WHEN TESTED IN <br />ACCORDANCE WITH ASTM D 6817 SHALL BE: <br />1)DENSITY SHALL BE A MINIMUM OF 1.80 LB/FT3 (28.8 KG/M3), <br />WHEN TESTED IN ACCORDANCE WITH ASTM D 1622. <br />2)COMPRESSIVE RESISTANCE AT 1 PERCENT DEFORMATION <br />SHALL BE A MINIMUM OF 10.9 PSI (75 KPA) WHEN TESTED IN <br />ACCORDANCE WITH ASTM D 1621. <br />3)FLEXURAL STRENGTH SHALL BE A MINIMUM OF 50.0 PSI (345 <br />KPA) WHEN TESTED IN ACCORDANCE WITH ASTM C 203. <br />4)ELASTIC MODULUS SHALL BE A MINIMUM OF 1090 PSI (7500 KPA) <br />WHEN TESTED IN ACCORDANCE WITH ASTM C 203. <br />5)OXYGEN INDEX SHALL HAVE A MINIMUM VOLUME OF 24.0 <br />PERCENT WHEN TESTED IN ACCORDANCE WITH ASTM C 2863. <br />2.CONNECTORS: CONNECTORS SHALL BE GALVANIZED STEEL <br />MULTI-BARBED CONNECTORS OR A URETHANE ADHESIVE AS <br />RECOMMENDED BY THE MANUFACTURER. EACH CONNECTOR SHALL <br />HAVE A LATERAL HOLDING STRENGTH OF AT LEAST 60 LBS (27.22 KG) <br />WHEN TESTED WITH AN EPS15 GEOFOAM. <br />STRUCTURAL FOAM NOTES <br />1.80 (28.8) <br />10.9 (75) <br />24.7 (170) <br />29.0 (200) <br />50.0 (345) <br />24.0 <br />< 2% <br />60.6 (970) <br />.05 <br />.6 <br />< 4.0 <br />1090 (7500) <br />TYPE - EPS 29 <br />DENSITY (NOMICAL PCF) <br />COMPRESSIVE RESISTANCE MIN. @ 1% DEFORMATION <br />COMPRESSIVE RESISTANCE MIN. @ 5% DEFORMATION <br />COMPRESSIVE STRENGTH (PSI, 10% DEFORMATION) <br />FLEXURAL STRENGTH (MIN. PSI) <br />OXYGEN INDEX, MIN. <br />DIMENSIONAL STABILITY <br />BUOYANCY FORCE <br />POISSON’S RATIO <br />COEFfiCIENT OF FRICTION <br />ABSORPTION <br />ELASTIC MODULUS, MIN. <br />1.PLAN SHALL BE IN ACCORDANCE WITH 2018 CBC. <br />2.REINFORCEMENT STEEL SHALL MEET ASTM A615-40. LAP SPLICES SHALL <br />BE AT LEAST 40 BAR DIAMETERS. ALL BENDS SHALL BE SHARP. IBC 2018 <br />SHALL BE USED AS A GUIDELINE. <br />3.REBAR PLACEMENT SHALL BE SUCH THAT THE DISTANCE FROM THE INSIDE <br />GROUT FACE TO REBAR SHOULD BE A MIN. OF "TG" - 3 INCHES. <br />4.UP TO 2 INCH DIAMETER PIPE MAY BE PLACED IN THE LOWER OUTSIDE <br />CORNER OF THE BOND BEAM PROVIDED A MINIMUM CLEARANCE EQUAL TO <br />0.75 TIMES THE NOMINAL MAXIMUM AGGREGATE SIZE (I.E., 1/4 INCH FOR <br />SHOTCRETE) IS MAINTAINED BETWEEN THE PIPE AND ANY PARALLEL <br />REINFORCEMENT PER IBC 2018. <br />5.IF METAL PIPING IS USED AND IS PLACED IN SHOTCRETE, IT SHALL BE <br />WRAPPED WITH VISQUEEN OR HEAVY BROWN PAPER EXCEPT WHERE IT <br />PASSES PERPENDICULARLY THROUGH THE SHOTCRETE. <br />6.CONCRETE CAN BE PLACED AGAINST SHOTCRETE AND STRUCTURAL <br />FOAM. <br />7.ELECTRICAL SHALL BE SECURELY GROUNDED BEFORE APPLYING <br />SHOTCRETE. <br />8.ALL STATE AND LOCAL LAWS AND CODES SHALL BE FOLLOWED. <br />9.POOL & SPA SHALL BE MAINTAINED FULL OF WATER EXCEPT DURING <br />CHANGE OF WATER OR SIMILAR SHORT TERM MAINTENANCE ACTIVITIES. <br />10.SHOTCRETE SHALL BE EQUAL TO CEMEX (MIX CODE: 1559997) 4,000 PSI, 3 <br />8" <br />FLY ASH SHOTCRETE. <br />11.THE BEGINNER OF RECORD FOR THE VAULT STRUCTURE SUPPORTING THE <br />POOL SHALL REVIEW THE STRUCTURAL DETAILS AND BASED ON THE POOL <br />DESIGN AND DEPTH, CERTIFY THAT THE VAULT STRUCTURE WAS <br />DESIGNED TO SUPPORT THE WEIGHT OF THE POOL & SPA WITHOUT <br />DEFLECTION. <br />12.IF THE POOL & SPA ARE LOCATED SUCH THAT WATER LEAKAGE FROM THE <br />THEM COULD DAMAGE UNDERLYING OR ADJACENT FACILITIES, A <br />SECONDARY LEAKAGE CONTAINMENT AND DISPOSAL SYSTEM SHALL BE <br />INCORPORATED AS PART OF THE POOL & SPA INSTALLATION. <br />13.PRIOR TO THE APPLICATION OF THE POOL & SPA WATERPROOFING FINISH <br />SURFACE COATING, THE SHOTCRETE SHELL SHALL BE CLOSELY EXAMINED <br />TO LOCATE ANY SHRINKAGE CRACKS. THE SHRINKAGE CRACKS SHALL BE <br />INJECTED WITH HIGH PRESSURE EPOXY TO THE GREATEST DEPTH <br />POSSIBLE. <br />STRUCTURAL SHOTCRETE <br />1.SHOTCRETING SHALL CONFORM TO ALL REQUIREMENTS OF <br />”SPECIFICATIONS FOR MATERIALS, PROPORTIONS, AND APPLICATION OF <br />SHOTCRETE” (ACI--506.2, LATEST EDITION). <br />2.PORTLAND CEMENT SHALL CONFORM TO ASTM C--150, TYPE I OR II, <br />ALKALI CONTENT NOT TO EXCEED 0.6G WHEN §5 OR SMALLER BARS ARE <br />USED, THERE SHALL BE A MINIMUM CLEARANCE BETWEEN PARALLEL. <br />3.REINFORCEMENT BARS OF 2 1/2” INCHES. WHEN BARS LARGER THAN §5 <br />ARE USED, THERE SHALL BE A MINIMUM CLEARANCE BETWEEN PARALLEL <br />BARS EQUAL TO 6 DIAMETERS OF THE BARS USED. WHEN T\Y0 CURTAINS <br />OR STEEL ARE PROVIDED, THE CURTAIN NEAREST THE NOZZLE SHALL <br />HA\/E A MINIMUM SPACING EQUAL TO 12 BAR DIAMETERS AND THE <br />REMAINING CURTAIN SHALL HAVE A MINIMUM SPACING OF 6 BAR <br />DIAMETERS. <br />4.LAP SPLICES IN REINFORCING BARS SHALL BE BY THE NON--CONTACT <br />LAP SLICE METHOD WITH AT LEAST 2 INCHES CLEARANCE BETWEEN <br />BARS. CONTACT LAP SPLICES MAY BE PERMITTED WHEN NECESSARY <br />FOR THE SUPPORT OF THE REINFORCING PROVIDED IT CAN BE <br />DEMONSTRATED BE MEANS OF PRE--CONSTRUCTION TESTING THAT <br />ADEQUATE ENCASEMENT OF THE BARS AT THE SPLICE CAN BE ACHIEVED <br />AND PROVIDED THAT THE SPICES ARE PLACED SO THAT A LINE THROUGH <br />THE CENTER OF THE TWO SPLICED BARS IN PERPENDICULAR TO THE <br />SURFACE OF THE SHOTCRETE WORK. <br />5.ANY REBOUND OR ACCUMULATED LOOSE AGGREGATE SHALL BE <br />REMOVED FROM THE SURFACES TO BE COVERED PRIOR TO PLACING <br />THE INITIAL OR ANY SUCCEEDING LAYERS OF SHOTCRETE. REBOUND <br />SHALL NOT BE USED AS AGGREGATE. <br />6.UNFINISHED W0RK SHALL NOT BE ALLOWED TO STAND FOR MORE THAN <br />30 MINUTES UNLESS ALL EDGES ARE SKIPPED T0 A THIN EDGE. BEFORE <br />PLACING ADDITIONAL MATERIEL ADJACENT TO PREVIOUSLY APPLIED <br />WORK, SLOPING AND SQUARE EDGES SHALL BE CLEANED AND WETTED. <br />7.IN PLACE SHOTCRETE WHICH EXHIBITS SAGS OR SLOUGHS, <br />SEGREGATION, HONEYCOMBING, SAND POCKETS OR OTHER OBVIOUS <br />DEFECTS SHALL BE REMOVED AND REPLACED. SHOTCRETE ABOVE SAGS <br />AND SLOUGHS SHALL BE REMOVED AND REPLACED WHILE SILL PLASTIC. <br />8.DURING THE CURING PERIODS SPECIFIED HEREIN. <br />9.SHOTCRETE SHALL BE MAINTAINED ABOVE 40 DEGREE F AND IN MOIST <br />CONDITION. <br />10.IN INITIAL CURING, SHOTCRETE SHALL BE KEPT CONTINUOUSLY MOIST <br />FOR 24 HOURS AFTER PLACEMENT IS COMPLETE. <br />11.FINAL CURING SHALL CONTINUE FOR 7 DAYS AFTER SHOTCRETING FOR 3 <br />DAYS IF HIGH EARLY STRENGTH CEMENT IS USED, OR UNTIL THE <br />SPECIFIED STRENGTH IS OBTAINED. <br />12.FINAL CURING SHALL CONSIST OF A FOG SPRAY OR AN APPROVED <br />MOISTURE RETAINING COVER OR MEMBRANE. <br />13.IN SECTIONS OF A DEPTH IN EXCESS OF 12 INCHES, FINAL CURING SHALL <br />BE THE SAME AS THAT FOR INITIAL CURING. <br />14.STRENGTH TEST FOR SHOTCRETE SHALL BE MADE BY AN APPRO\/ED <br />AGENCY ON SPECIMENS MICH ARE REPRESENTATIVE OF AND IN <br />ACCORDANCE WITH THE IBC. <br />15.WHEN SHOTCRETE IS USED FOR STRUCTURAL MEMBERS, A SPECIAL <br />INSPECTOR IS REQUIRED. THE SPECIAL INSPECTOR SHALL PROVIDE <br />CONTINUOUS INSPECTION OF THE PLACEMENT OF THE REINFORCEMENT <br />AND SHOTCRETINC AND SHALL SUBMIT A STATEMENT INDICATING <br />COMPLIANCE RTH THE PLANS AND SPECIFICATIONS, NOTE: SUMMARY <br />SPECIAL INSPECTION SUBMITTED TO BUILDING DEPT. <br />16.REFERENCE ibc 2018 TABLE 25.3.1—STANDARD HOOK GEOMETRY FOR <br />DEVELOPMENT OF DEFORMED BARS IN TENSION <br />COORDINATION ITEMS <br />POOL ENCLOSURE <br />DECK DESIGN <br />DECK DRAINAGE <br />BATHROOM DESIGN <br />DECK LEVEL LIGHTING <br />DECK CLEANING HYDRANTS <br />DRINKING FOUNTAIN <br />DECK LEVEL ACCESS CONTROL <br />SHEET <br />EQUIPMENT ROOM LIGHTING <br />DECK LEVEL POWER PLAN <br />FILTER WASTE <br />HEATER GAS SUPPLY <br />POOL FILL COLD WATER SUPPLY <br />POOL LIFE SATETY PLAN <br />EQUIPMENT ROOM FLOOR DRAIN <br />1.03 3714 - SHOTCRETE FOR POOLS. <br />2.07 1417 - COLD FLUID-APPLIED WATERPROOFING FOR POOLS. <br />3.09 3014 - CERAMIC TILING FOR SWIMMING POOLS. <br />4.09 9727 - CEMENTITIOUS COATINGS FOR POOLS. <br />5.13 1133 - ELEVATED SWIMMING POOLS <br />ABBREVIATIONS <br />ACI AMERICAN CONCRETE INSTITUTE <br />ADA AMERICAN WITH DISABILITIES ACT <br />ANSI AMERICAN NATIONAL STANDARDS INSTITUTE <br />ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS <br />ASTM AMERICAN SOCIETY OF TESTING MATERIALS <br />BTU BRITISH THERMAL UNIT <br />CAS CHEMICAL ABSTRACT SERVICES <br />CPVC CHLORINATED POLYVINYL CHLORIDE <br />GC GENERAL CONTRACTOR <br />GFCI GROUND FAULT CIRCUIT INTERRUPTER <br />GPM GALLONS PER MINUTE <br />Hz HERTZ <br />LBS POUNDS <br />MCEHC MARICOPA COUNTY ENVIRONMENTAL HEALTH CODE <br />NFPA NATIONAL FIRE PROTECTION ASSOCIATION <br />NSF NATIONAL SANITATION FOUNDATION <br />NTS NOT TO SCALE <br />ORP OXIDATION REDUCTION POTENTIAL <br />OSHA OCCUPATIONAL SAFETY & HEALTH ADMINISTRATION <br />pH POTENTIAL HYDROGEN <br />PPM PARTS PER MILLION <br />PSI POUNDS PER SQUARE INCH <br />PVC POLYVINYL CHLORIDE <br />SCH SCHEDULE <br />SS STAINLESS STEEL <br />UL UNDERWRITERS LABORATORIES INC. <br />V VOLTS <br />Jun 04, 2024 <br />1/7/25