My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
301 N Broadway - Shell & Core - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Broadway
>
301 N Broadway
>
301 N Broadway - Shell & Core - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 10:51:20 AM
Creation date
2/24/2026 10:50:24 AM
Metadata
Fields
Template:
Plan
Permit Number
101120309
Full Address
301 N Broadway
Street Number
301
Street Direction
N
Street Name
Broadway
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2081
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br /> <br /> <br /> <br /> <br /> <br />3rd & Broadway, Santa Ana, CA <br />Volume 1 - Basis of Design June 17, 2024 | Project # S21043.00 <br /> pg. 35 <br />2.6 GEOTECHNICAL CRITERIA <br /> <br />2.6.1 FOUNDATION DESIGN METHODOLOGY <br /> <br />The soil bearing capacities for permanent and short -term loading are provided in the geotechnical <br />report for mat foundations. Service-level seismic loads are obtained by applying a 0.7 factor to the <br />design level seismic loads. <br /> <br />2.6.2 BELOW-GRADE AND RETAINING WALLS <br />Per the geotechnical report, it is recommended to design the basement wall the more critical of two <br />conditions. <br />1) At-rest pressure using an equivalent fluid weight of 60 pcf (triangular distribution); <br /> 2) Active pressure using an equivalent fluid weight of 40 pcf (triangular distribution) plus a seismic <br />increment of 15pcf (triangular distribution). <br />When traffic loads are expected within 10 feet of the walls, an additional design load of 100 psf <br />should be applied to the upper 10 feet of the wall. <br /> <br />2.6.3 GROUNDWATER <br />Per the geotechnical report, a groundwater elevation no closer than 40 feet below ground surface <br />was historically reported by CGS. However, no ground water was only encountered at a depth of <br />76.5 feet b.g.s. during Leighton’s initial test boring investigation. <br /> <br />2.6.4 SETTLEMENT <br />Per the geotechnical report, the static settlement of the proposed foundation supported on mat <br />foundations are anticipated to settle 2 inch or less. Differential settlement is expected to be about <br />1 inch over a 30-foot horizontal distance. <br />
The URL can be used to link to this page
Your browser does not support the video tag.