<br />MAIN ENTRY FLOOR
<br />DOOR CLOSED
<br />DOOR OPEN EMERGENCY STOP
<br />OCTAGON SYMBOL
<br />SHALL BE RAISED
<br />BUT THE "X" IS NOT
<br />EMERGENCY ALARM
<br />ELEVATOR LOBBY
<br />ELEVATOR CONTROL PANEL
<br />CENTER OPENING DOORS SIDE OPENING DOOR
<br />80" MIN
<br />54
<br />"
<br />
<br />M
<br />I
<br />N
<br />51
<br />"
<br />
<br />M
<br />I
<br />N
<br />68" MIN
<br />51
<br />"
<br />
<br />M
<br />I
<br />N
<br />54
<br />"
<br />
<br />M
<br />I
<br />N
<br />42" MIN 36" MIN
<br />INTERNATIONAL
<br />"STAR OF LIFE"
<br />SYMBOL
<br />HALL
<br />LANTERN
<br />FLOOR LANDING NUMBERS ON
<br />BOTH SIDES OF JAMB
<br />HALL CALL BUTTONS
<br />EMERGENCY SIGN
<br />A
<br />B
<br />NOTE: THE
<br />AUTOMATIC OPENING
<br />DEVICE IS ACTIVATED
<br />IF AN OBJECT PASSES
<br />THROUGH EITHER
<br />LINE A OR B. LINE A
<br />AND LINE B
<br />REPRESENT THE
<br />VERTICAL LOCATIONS
<br />OF THE DOOR
<br />REOPENING DEVICE
<br />NOT REQUIRING
<br />CONTACT.
<br />NOTE: ELEVATOR
<br />CAR SHALL
<br />ACCOMMODATE A
<br />24"X84" GURNEY OR
<br />STRETCHER
<br />1-1/2" DIA. HANDRAIL, 1-1/2" FROM
<br />WALL (1 MIN, REAR WALL
<br />PREFERRED), 31-33" AFF (TYP)
<br />ANY DOOR LOCATION
<br />60" MIN
<br />60
<br />"
<br />
<br />M
<br />I
<br />N
<br />36" MIN
<br />ANY DOOR LOCATION
<br />54" MIN
<br />80
<br />"
<br />
<br />M
<br />I
<br />N
<br />36" MIN
<br />5/8"MIN NUMERAL
<br />HEIGHT
<br />3/4" MIN CONTROL
<br />BUTTON DIA
<br />PE
<br />R
<br />
<br />C
<br />B
<br />C
<br />SE
<br />C
<br />.
<br />
<br />1
<br />1
<br />B
<br />-
<br />7
<br />0
<br />3
<br />.
<br />4
<br />.
<br />1
<br />2"
<br />.
<br />60
<br />"
<br />
<br />A
<br />.
<br />F
<br />.
<br />F
<br />.
<br />REQUIRED EXIT SIGNS Tactile exit signs shall be required at the following locations:
<br />1. Each grade-level exterior exit door that is required to comply with Section 1011.1, shall be identified by a tactile exit sign
<br />with the word, “EXIT.”
<br />2. Each exit door that is required to comply with Section 1011.1, and that leads directly to a grade-level exterior exit by
<br />means of a stairway or ramp shall be identified by a tactile exit sign with the following words as appropriate:
<br />2.1. “EXIT STAIR DOWN” 2.2. “EXIT RAMP DOWN” 2.3. “EXIT STAIR UP” 2.4. “EXIT RAMP UP”
<br />3. Each exit door that is required to comply with Section 1011.1, and that leads directly to a grade-level exterior exit by
<br />means of an exit enclosure or an exit passageway shall be identified by a tactile exit sign with the words, “EXIT ROUTE.”
<br />4. Each exit access door from an interior room or area to a corridor or hallway that is required to comply with Section 1011.1,
<br />shall be identified by a tactile exit sign with the words “EXIT ROUTE.”
<br />5. Each exit door through a horizontal exit that is required to comply with Section 1011.1, shall be identified by a sign with the
<br />words, “TO EXIT.”
<br />6. Each door providing access to an area of refuge from an adjacent floor area shall be identified by a sign stating: "AREA
<br />OF REFUGE".
<br />7. Each door providing access to an exterior area for assisted rescue shall be identified by a sign stating: "EXTERIOR AREA
<br />FOR ASSISTED RESCUE".
<br />Raised character and Braille exit signs shall comply with Chapter 11B, Sections 11B-703.1, 11B-703.2, 11B-703.3 and
<br />11B-703.5.
<br />REQUIRED DIRECTIONAL SIGNAGE. Direction signage complying with Chapter 11B, Section 11B-703.5 indicating the
<br />location of the other means of egress and which are accessible means of egress shall be provided at the following:
<br />
<br />1. At exits serving a required accessible space but not providing an approved accessible means of egress.
<br />2. At elevator landings.
<br />3. Within areas of refuge
<br />REQUIRED STAIR IDENTIFICATION SIGNS. A sign shall be provided at each floor landing in an interior exit stairway and
<br />ramp connecting more than three stories designating the floor level, the terminus of the top and bottom of the interior exit
<br />stairway and ramp and the identification of the stair or ramp. The signage shall also state the story of, and the direction to,
<br />the exit discharge and the availability of roof access from the interior exit stairway and ramp for the fire department. The sign
<br />shall be located 5 feet (1524 mm)
<br />above the floor landing in a position that is readily visible when the doors are in the open and closed positions.
<br />In addition to the stairway identification sign, raised characters and braille floor identification signs that comply with Chapter
<br />11B. Sections 11B-703.1, 11B-703.2, 11B-703.3 and 11B-703.5 shall be located at the landing of each floor level, placed
<br />adjacent to the door on the latch side, in all enclosed stairways in buildings two or more stories in height to identify the floor
<br />level. At the exit discharge level, the sign shall include a raised five pointed star located to the left of the identifying floor
<br />level. The outside diameter of the star shall be the same as the height of the raised characters.
<br />1'
<br />-
<br />6
<br />"
<br />1'-0"
<br />TO EXIT
<br />5/8"
<br />10"
<br />4"
<br />3/
<br />8
<br />"
<br />
<br />-
<br />
<br />1
<br />/
<br />2
<br />"
<br />1/4" RADIUS, TYP.
<br />60
<br />"
<br />
<br />M
<br />A
<br />X
<br />
<br />A
<br />.
<br />F
<br />.
<br />F
<br />.
<br />48
<br />"
<br />
<br />M
<br />I
<br />N
<br />
<br />A
<br />.
<br />F
<br />.
<br />F
<br />.
<br />1. CONTRACTOR TO COMPLY WITH CODES, LAWS, ORDINANCES, RULES, AND REGULATIONS OF PUBLIC
<br />AUTHORITIES GOVERNING THE
<br />WORK. .
<br />2. CONTRACTOR TO OBTAIN AND PAY FOR PERMITS AND INSPECTIONS REQUIRED BY PUBLIC AUTHORITIES
<br />GOVERNING THE WORK. .
<br />3. CONTRACTOR TO REVIEW DOCUMENTS, VERIFY DIMENSIONS AND FIELD CONDITIONS AND CONFIRM
<br />THAT WORK IS BUILDABLE AS SHOWN. REPORT ANY CONFLICTS OR OMISSIONS TO THE ARCHITECT FOR
<br />CLARIFICATION PRIOR TO PERFORMING ANY WORK IN
<br />QUESTION. .
<br />4. FOR SUBSTITUTIONS REFER TO
<br />SPECIFICATIONS. .
<br />5. CONTRACTOR TO COORDINATE WORK WITH THE OWNER, INCLUDING SCHEDULING TIME AND
<br />LOCATIONS FOR DELIVERIES, BUILDING ACCESS, USE OF BUILDING SERVICES AND FACILITIES, AND USE
<br />OF ELEVATORS. COORDINATE WORK WITH OTHER CONTRACTS. MINIMIZE DISTURBANCE OF BUILDING
<br />FUNCTIONS AND OCCUPANTS, INCLUDING TRASH REMOVAL
<br />ACCESS . .
<br />6. OWNER WILL PROVIDE WORK NOTED "BY OTHERS" OR "NIC" UNDER SEPARATE CONTRACT. INCLUDE
<br />SCHEDULE REQUIREMENTS IN CONSTRUCTION PROGRESS SCHEDULE AND COORDINATE TO ASSURE
<br />ORDERLY SEQUENCE OF
<br />INSTALLATION. .
<br />7. CONTRACTOR TO COORDINATE TELECOMMUNICATIONS, DATA AND SECURITY SYSTEM
<br />INSTALLATIONS. .
<br /> .
<br />8. CONTRACTOR TO MAINTAIN EXITS, EXIT LIGHTING, FIRE PROTECTIVE DEVICES, AND ALARMS IN
<br />CONFORMANCE WITH CODES AND
<br />ORDINANCES. .
<br />9. CONTRACTOR TO PROTECT AREA OF WORK AND ADJACENT AREAS FROM DAMAGE. G.C. TO
<br />COORDINATE TRASH
<br />ACCESS. .
<br />10. CONTRACTOR TO MAINTAIN WORK AREAS SECURE AND LOCKABLE DURING
<br />CONSTRUCTION. .
<br />11. DO NOT SCALE DRAWINGS. DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALES SHOWN ON
<br />DRAWINGS. GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS, GRADES AND CONDITIONS AT SITE
<br />PRIOR TO COMMENCING THE WORK, AND REPORT ANY DISCREPANCIES TO THE CONSTRUCTION
<br />MANAGER IN
<br />WRITING. .
<br />12. PARTITIONS ARE DIMENSIONED FROM FINISH FACE TO FINISH FACE, UNLESS OTHERWISE NOTED.
<br />MAINTAIN DIMENSIONS MARKED "CLEAR". ALLOW FOR THICKNESS OF
<br />FINISHES. .
<br />13. FLOOR LEVELS INDICATED ON DRAWINGS ARE FOR REFERENCE ONLY. PRIOR TO CONSTRUCTION
<br />GENERAL CONTRACTOR SHALL HIRE A THIRD PARTY LICENSED SURVEYOR TO FIELD VERIFY EXISTING
<br />GRADES AND FLOOR ELEVATIONS INDICATED ON DRAWING. NOTIFY ARCHITECT IMMEDIATELY OF ANY
<br />DISCREPANCIES. .
<br />14. WHERE EXISTING ACCESS PANELS CONFLICT WITH CONSTRUCTION. CONTRACTOR TO RELOCATE
<br />PANELS TO ALIGN WITH AND FIT WITHIN NEW
<br />CONSTRUCTION. .
<br />15. CONTRACTOR TO UNDERCUT DOORS TO CLEAR TOP OF FLOOR FINISHES BY 1/4 INCH, UNLESS
<br />OTHERWISE
<br />NOTED. .
<br />16. CEILING HEIGHT DIMENSIONS ARE TO FINISHED
<br />SURFACES. .
<br />17. CONTRACTOR SHALL PROVIDE CONSTRUCTION BARRICADES OR FENCING AS REQUIRED AND AS
<br />APPROVED BY THE CITY FOR PUBLIC SAFETY PRIOR TO COMMENCING THE
<br />WORK. .
<br />18. CONTRACTOR TO COORDINATE AND PROVIDE BACKING FOR MILLWORK AND ITEMS ATTACHED OR
<br />MOUNTED TO WALLS OR
<br />CEILINGS. .
<br />19. FIRE PROTECTION EQUIPMENT AND SERVICE ACCESS MUST BE PROVIDED DURING THE CONSTRUCTION
<br />PERIOD AS REQUIRED BY THE
<br />CITY. .
<br />20. CONTRACTOR SHALL PROVIDE TEMPORARY EXIT SIGNS TO ASSURE A MEANS OF EGRESS DURING
<br />CONSTRUCTION. .
<br />21. WHERE A TYPICAL CONDITION IS DETAILED, IT SHALL BE UNDERSTOOD THAT ALL LIKE OR SIMILAR
<br />CONDITIONS ARE THE SAME UNLESS SPECIFICALLY NOTED OR DETAILED
<br />OTHERWISE. .
<br />22. PUBLIC IMPROVEMENTS AND SERVICES ADJACENT TO THE SITE SHALL BE MAINTAINED DURING
<br />CONSTRUCTION. APPROVAL OF THE CITY ENGINEERING DEPARTMENT IS REQUIRED BEFORE ANY WORK
<br />IS COMMENCED. .
<br />23. GENERAL CONTRACTOR SHALL COORDINATE SITE PLUMBING,DRAINAGE, ELECTRICAL, TELEPHONE
<br />WORK AND EXISTING UTILITIES TO PROVIDE A COMPLETE OPERATING
<br />SYSTEM. .
<br />24. CONTRACTOR SHALL OBTAIN NECESSARY PERMITS FROM STATE OF CALIFORNIA, DIVISION OF
<br />INDUSTRIAL SAFETY, OSHA DEPARTMENT, FOR WORK ON BUILDINGS OVER 36'-0" IN
<br />HEIGHT. .
<br />25. EXCEPT WHERE SHOWN IN DIMENSIONAL DETAIL, THE LOCATIONS OF PLUMBING, MECHANICAL
<br />EQUIPMENT, DUCTS, PIPING, AND FITTING ARE ONLY APPROXIMATE. THE EXACT LOCATIONS SHALL BE
<br />DETERMINED BY THE CONTRACTOR, SUBJECT TO APPROVAL BY THE
<br />ARCHITECT. .
<br />26. CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL MECHANICAL EQUIPMENT PADS AND BASES
<br />AS WELL AS POWER AND WATER OR DRAIN INSTALLATIONS WITH EQUIPMENT MANUFACTURERS
<br />BEFORE PROCEEDING WITH THE WORK. CHANGES TO ACCOMMODATE FIELD CONDITIONS OR
<br />SUBSTITUTIONS SHALL BE MADE AT NO ADDITIONAL
<br />COST. .
<br />27. CONTRACTOR SHALL VERIFY SIZE AND LOCATION OF ALL MECHANICAL OPENINGS THROUGH THE ROOF
<br />WITH MECHANICAL EQUIPMENT
<br />MANUFACTURERS.
<br />.
<br />28. CONTRACTOR SHALL PROVIDE AND INSTALL ALL STIFFENERS, BRACING, BLOCKING, BACK-UP PLATES
<br />AND SUPPORTING BRACKETS REQUIRED FOR THE INSTALLATION OF ALL CASEWORK, TOILET ROOM
<br />ACCESSORIES, FIXTURES AND PARTITIONS AND ALL WALL MOUNTED OR SUSPENDED MECHANICAL,
<br />ELECTRICAL OR MISCELLANEOUS EQUIPMENT AND
<br />FURNISHINGS. .
<br />29. MECHANICAL SUPPLY AND RETURN AIR SHAFTS SHALL BE AIRTIGHT AND
<br />SEALED. .
<br />30. ALL WORK PERFORMED SHALL COMPLY WITH THE CONTRACT DOCUMENTS, DRAWINGS AND
<br />SPECIFICATIONS, INCLUDING THESE GENERAL NOTES. THE CONTRACTOR SHALL COORDINATE THE
<br />INTENT OF THE GENERAL NOTES WITH ALL
<br />TRADES .
<br />31. SPECIFICATIONS, BOUND SEPARATELY, ARE PART OF THE CONTRACT
<br />DOCUMENTS. .
<br />32. THE ORGANIZATION OF THE DRAWINGS AND SPECIFICATIONS SHALL NOT CONTROL THE CONTRACTOR
<br />IN DIVIDING THE WORK AMONG SUBCONTRACTORS OR IN ESTABLISHING THE EXTENT OF WORK TO BE
<br />PERFORMED BY ANY
<br />TRADE. .
<br />33. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE DRAWINGS AND SPECIFICATIONS. IF
<br />CONFLICT IS FOUND BETWEEN DRAWINGS, GENERAL NOTES AND SPECIFICATIONS, CONSULT THE
<br />ARCHITECT FOR CLARIFICATION BEFORE PROCEEDING WITH THE
<br />WORK. .
<br />34. NO DEVIATION FROM CONTRACT DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT WRITTEN
<br />APPROVAL OF THE ENGINEER AND/OR
<br />ARCHITECT. .
<br />35. THE STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS ARE SUPPLEMENTARY TO THE
<br />ARCHITECTURAL DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO CHECK WITH
<br />THE ARCHITECTURAL DRAWINGS BEFORE THE INSTALLATION OF STRUCTURAL, MECHANICAL AND
<br />ELECTRICAL WORK. SHOULD THERE BE A DISCREPANCY BETW EEN THE ARCHITECTURAL DRAWINGS
<br />AND THE CONSULTING ENGINEERS' DRAWINGS THAT WOULD CAUSE AN AWKWARD INSTALLATION, IT
<br />SHALL BE BROUGHT TO THE ENGINEER'S ATTENTION FOR CLARIFICATION PRIOR TO INSTALLATION OF
<br />SAID WORK. ANY WORK INSTALLED IN CONFLICT WITH THE ARCHITECTURAL DRAWINGS SHALL BE
<br />CORRECTED BY THE CONTRACTOR AT NO ADDITIONAL
<br />COST. .
<br />36. CONTRACTOR SHALL OBTAIN NECESSARY PERMITS FROM STATE OF CALIFORNIA, DIVISION OF
<br />INDUSTRIAL SAFETY, OSHA DEPARTMENT, FOR TRENCHES OR EXCAVATIONS GREATER THAN 5'-0" DEEP
<br />INTO WHICH A PERSON IS REQUIRED TO DESCEND FOR CONSTRUCTION
<br />PURPOSES. .
<br />37. CONTRACTOR SHALL AS NECESSARY PROVIDE SHORING DESIGNED AND DETAILED BY A CALIFORNIA
<br />REGISTERED
<br />ENGINEER. .
<br />38. DOORS OPENING INTO REQUIRED 1-HOUR, FIRE-RESISTIVE CORRIDORS SHALL BE PROTECTED WITH A
<br />SMOKE OR DRAFT STOP ASSEMBLY HAVING A 20-MINUTE RATING AND SHALL BE SELF-
<br />CLOSING. .
<br />39. 20-MINUTE DOOR JAMBS TO BE TIGHT-FITTING, SMOKE AND DRAFT
<br />CONTROLLED. .
<br />40. EXIT DOORS SHALL SWING IN THE DIRECTION OF TRAVEL WHEN SERVING 50 OR MORE PERSONS AND IN
<br />ANY HAZARDOUS
<br />AREA. .
<br />41. PROVIDE FIRE DAMPERS OR DOORS WHERE AIR DUCTS PENETRATE FIRE-RATED WALLS OR
<br />CEILINGS. .
<br />42. WOOD BLOCKING SHALL BE FIRE TREATED IN ACCORDANCE WITH APPLICABLE CODE
<br />REQUIREMENTS. .
<br />43. IF THE SPACE ABOVE THE SUSPENDED CEILING IS USED AS A RETURN AIR PLENUM, THEN ALL
<br />EQUIPMENT AND WIRING(COMMUNICATION, POWER ETC) SHALL BE LISTED FOR INSTALLATION IN A
<br />PLENUM. .
<br />44. ALL FLEXIBLE AIRDUCTS, IF USED, SHALL MEET THE REQUIREMENTS OF NFPA 90A, 2-3-2 IN
<br />CONSTRUCTION AND
<br />INSTALLATION. .
<br />45. PROVIDE ALL ACCESS PANELS REQUIRED FOR ALL JUNCTION BOXES, VALVES, CLEANOUTS, PLUGS,
<br />FILTERS, EQUIPMENT AND ALL OTHER ITEMS REQUIRING SERVICE AND MAINTENANCE
<br />1. AUTOMATIC EXTERNAL DEFIBRILLATORS (AED’S) SHALL BE DESIGNED AND LOCATED UNDER THE
<br />TENANT IMPROVEMENT PERMIT. AED’S SHALL BE INSTALLED AND MEET THE REQUIREMENTS BELOW
<br />PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY.
<br />2. AED'S ARE REQUIRED IN NEW BUILDINGS AND TENANT SPACES IN SHELL BUILDINGS WHEN THE
<br />OCCUPANT LOAD WITHIN THE BUILDINGS WHEN THE OCCUPANT LOAD WITHIN THE BUILDING OR THE
<br />OCCUPANT LOAD WITHIN AN OCCUPANCY OR TENANT SPACES EXCEEDS THE OCCUPANT LOADS IN
<br />TABLE 145-3910 OF THE MUNICIPAL CODE. (SECT. 145.3910 (A))
<br />3. AED'S SHALL BE CONSPICUOUSLY PLACED AND READILY ACCESSIBLE IN THE EVENT OF AN EMERGENCY.
<br />AED'S SHALL BE MOUNTED SUCH THAT THE TOP OF THE AED IS NO MORE THAN FIVE (5) FEET ABOVE
<br />FLOOR LEVEL.
<br />4. WHEN REQUIRED TO BE LOCATED ON THE FLOOR LEVEL OF THE BUILDING PURSUANT TO SECTION
<br />145.3910 AND TABLE 145-3910, ONE AED SHALL BE PLACED AT THE MAIN ENTRANCE OF EVERY FLOOR
<br />REQUIRED TO HAVE ONE OR MORE AED'S. (SEC. 145.3915 (B) 1)
<br />5. WHEN NOT REQUIRED ON EVERY FLOOR OF A BUILDING PURSUANT TO SECTION 145.3910 AND TABLE
<br />145-3910, AED'S SHALL BE LOCATED SUCH THAT THE LENGTH OF VERTICAL TRAVEL BETWEEN ANY TWO
<br />ON ANY TWO FLOORS WITH AN AED SHALL NOT EXCEED 450 FEET. (SEC. 145.3915 ( C ) 2)
<br />6. THE BUILDING OWNER SHALL REGISTER AED(S), AT THE TIME IT IS ACQUIRED, WITH THE CITY OF Los
<br />Angeles FIRE-RESCUE DEPARTMENT AND SHALL IDENTIFY THE EXISTENCE OF AED, LOCATION, AND TYPE
<br />OF AED.
<br />7. PRIOR TO FINAL OCCUPANCY THE BUILDING OWNER SHALL PROVIDE TO THE SATISFACTION OF THE
<br />FIRE-RESCUE DEPARTMENT WRITTEN VALIDATION AND PRESCRIPTION FOR USE OF THE AED (S) IS
<br />SECURED BY TRAINED INDIVIDUALS FROM A PRESCRIBING PHYSICIAN.
<br />8. TRAINED EMPLOYEES SHALL BE MADE AVAILABLE WITHIN THE BUILDING TO RESPOND TO AN
<br />EMERGENCY DURING NORMAL OPERATING HOURS.
<br />THE BUILDING OWNER SHALL BE RESPONSIBLE SHALL REPORT TO THE FIRE-RESCUE DEPARTMENT
<br />TENANTS ANNUAL RECEIPT OF AN AMERICAN HEART ASSOCIATION OR AMERICAN RED CROSS APPROVED
<br />BROCHURE ON THE PROPER USE OF AN AED ALSO POSTED NEXT TO ALL AED'S, AND TENANT NOTIFICATION
<br />OF THE LOCATION OF ALL AED'S IN THE BUILDING.
<br />1. STORM WATER POLLUTION CONTROL PREVENTION: COMPLY WITH LOCAL STORM WATER MANAGEMENT AND
<br />EROSION CONTROL ORDINANCES. Los Angeles MUNICIPAL CODE, CHAPTER 4, ARTICLE 3, DIVISION 3.
<br />2. LIGHT POLLUTION REDUCTION: COMPLY WITH LOCAL LIGHT POLLUTION CONTROL ORDINANCE. Los Angeles
<br />MUNICIPAL CODE 142.0740.
<br />3. PLUMBING FIXTURES SHALL MEET THE MAXIMUM FLOW RATE VALUES SHOWN IN CALIFORNIA GREEN
<br />BUILDING CODE TABLE 5.503.3.
<br />4. WATER CLOSETS SHALL NOT EXCEED 1.28 GALLONS PER FLUSH. TANK TYPE TOILETS SHALL BE CERTIFIED
<br />TO THE PERFORMANCE CRITERIA OF THE US EPA WATERSENSE SPECIFICATION.
<br />5. URINALS SHALL NOT EXCEED 0.5 GALLONS PER FLUSH.
<br />6. SINGLE SHOWER HEADS SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE THAN 2.0 GALLONS PER MINUTE
<br />AT 80 PSI.
<br />7. WHERE THERE ARE MULTIPLE SHOWER HEADS SERVING ONE SHOWER AND CONTROLLED BY A SINGLE
<br />VALVE, THE COMBINED FLOW RATE OF ALL SHOWERHEADS SHALL NOT EXCEED 2.0 GALLONS PER MINUTE AT
<br />80 PSI.
<br />8. CONSTRUCTION WASTE MANAGEMENT SHALL COMPLY WITH LOCAL ORDINANCES. Los Angeles MUNICIPAL
<br />CODE, CHAPTER 6, ARTICLE 6.
<br />9. PROVIDE READILY ACCESSIBLE RECYCLING AREAS FOR BUILDING OCCUPANTS PER LOCAL ORDINANCE. Los
<br />Angeles MUNICIPAL CODE, CHAPTER 6, ARTICLE 6 AND CHAPTER 14, ARTICLE 2, DIVISION 8.
<br />10. COVERING OF DUCT OPENINGS AND PROTECTION OF MECHANICAL EQUIPMENT DURING CONSTRUCTION: AT
<br />THE TIME OF ROUGH INSTALLATION AND DURING STORAGE ON THE CONSTRUCTION SITE UNTIL FINAL
<br />STARTUP OF THE HVAC EQUIPMENT, ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT
<br />OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, SHEET METAL OR OTHER METHODS ACCEPTABLE TO
<br />THE ENFORCING AGENCY TO REDUCE THE AMOUNT OF DUST, WATER AND DEBRIS WHICH MAY ENTER THE
<br />SYSTEM.
<br />11. ADHESIVES, ADHESIVE BONDING PRIMERS, ADHESIVE PRIMERS, SEALANTS, SEALANT PRIMERS AND CAULKS
<br />SHALL COMPLY WITH LOCAL OR REGIONAL AIR POLLUTION CONTROL OR AIR QUALITY MANAGEMENT
<br />DISTRICT RULES WHERE APPLICABLE, OR SCAQMD RULE 1168 VOC LIMITS AS SHOWN IN CAL GREEN TABLES
<br />5.504.4.1 AND 5.504.4.2. SUCH PRODUCTS ALSO SHALL COMPLY WITH RULE 1168 PROHIBITION ON THE USE OF
<br />CERTAIN TOXIC COMPOUNDS (CHOLORFORM, ETHYLENE DICHLORIDE, METHYLLENE CHLORIDE,
<br />PERCHLOROETHYLENE AND TRICHLOROETHYLENE).
<br />12. AEROSOL ADHESIVES, AND SMALLER UNIT SIZES OF ADHESIVES, AND SEALANT OR CAULKING COMPOUNDS
<br />(IN UNITS OF PRODUCT, LESS PACKAGING, WHICH DO NOT WEIGH MORE THAN ONE POUND AND DO NOT
<br />CONSIST OF MORE THAN 16 FLUID OUNCES) SHALL COMPLY WITH STATEWIDE VOC STANDARDS AND OTHER
<br />REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN TOXIC COMPOUNDS, OF CALIFORNIA CODE
<br />OF REGULATIONS, TITLE 17, COMMENCING WITH SECTION 94507.
<br />13. ARCHITECTURAL PAINTS AND COATINGS SHALL COMPLY WITH VOC LIMITS IN TABLE 1 OF THE ARB
<br />ARCHITECTURAL COATINS SUGGESTED CONTROL MEASURE, AS SHOWN IN CAL GREEN TABLE 5.504.4.3,
<br />UNLESS MORE STRINGENT LOCAL LIMITS APPLY. THE VOC CONTENT LIMIT FOR COATING THAT DO NOT MEET
<br />THE DEFINITIONS FOR THE SPECIALTY COATINGS CATEGORIES LISTED IN TABLE5.504.4.3 SHALL BE
<br />DETERMINED BY CLASSIFYING THE COATING AS A FLAT, NONFLAT OR NONFLAT-HIGH GLOSS COATING,
<br />BASED ON ITS GLOSS, AS DEFINED IN SUBSECTIONS 4.21, 4.36 AND 4.37 OF THE 2007 CALIFORNIA AIR
<br />RESOURCE BOARD SUGGESTED CONTROL MEASURE, AND THE CORRESPONDING FLAT, NONFLAT OR
<br />NONFLAT-HIGH GLOSS VOC LIMIT IN TABLE 5.504.4.3, SHALL APPLY.
<br />14. AEROSOL PAINTS AND COATINGS SHALL MEET THE PWMIR LIMITS FOR ROC IN SECTION 94522(a)(3) AND
<br />OTHER REQUIRMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN TOXIC COMPOUNDS AND OZONE
<br />DEPLETING SUBSTANCES, IN SECTIONS 94522(c)(2) AND (d)(2) OF CALIFORNIA CODE OF REGULATIONS, TITLE
<br />17, COMMENCING WITH SECTION 94520.
<br />15. ALL CARPET INSTALLED IN BUILDING INTERIORS SHALL MEET AT LEAST ONE OF THE FOLLOWING
<br />REQUIREMENTS: a) CARPET AND RUG INSTITUTE’S GREEN LABEL PLUS PROGRAM. b) COMPLIANT WITH
<br />THE VOC EMISSION LIMITS AND TESTING REQUIREMENTS SPECIFIED IN THE CALIFORNIA DEPARTMENT OF
<br />PUBLIC HEALTH STANDARD METHOD FOR THE TESTING AND EVALUATION OF VOLATILE ORGANIC CHEMICAL
<br />EMISSIONS FOR INDOOR SOURCES USING ENVIRONMENTAL CHAMBERS, VERSION 1.1., FEBRUARY 2010. c)
<br />NSF/ANSI 140 AT THE GOLD LEVEL OR HIGHER. d) SCIENTIFIC CERTIFICATIONS SYSTEM SUSTAINABLE
<br />CHOICE. e) COMPLIANT WITH THE CALIFORNIA COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS (CA-
<br />CHPS) CRITERIA INTERPRETATION FOR EQ 2.2 DATED JULY 2012 AND LISTED IN THE CHPS HIGH
<br />PERFORMANCE PRODUCT DATABASE.
<br />16. ALL CARPET CUSHION INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE REQUIREMENTS OF THE
<br />CARPET AND RUG INSTITUTES’S GREEN LABEL PROGRAM.
<br />17. HARDWOOD PLYWOOD, PARTICLE BOARD AND MEDIUM DENSITY FIBERBOARD COMPOSITE WOOD
<br />PRODUCTS USED ON THE INTERIOR OR EXTERIOR OF THE BUILDING SHALL MEET THE REQUIREMENTS FOR
<br />FORMALDEHYDE AS SPECIFIED IN THE ARB’S AIR TOXICS CONTROL MEASURE (ACTM) FOR COMPOSITE
<br />WOOD (17 CCR 93120 ET SEQ.) THOSE MATERIALS NOT EXEMPTED UNDER THE ACTM MUST MEET THE
<br />SPECIFIED EMISSION LIMITS, AS SHOWN IN CAL GREEN TABLE 5.504.4.5.
<br />18. RESILIENT FLOORING SYSTEMS: FOR 80 PERCENT OF FLOOR AREA RECEIVING RESILIENT FLOORING,
<br />INSTALLED RESILIENT FLOORING SHALL MEET ONE OF THE FOLLOWING: a) CERTIFIED UNDER THE RESILIENT
<br />FLOOR COVERING INSTITUTE (RFCI) FLOOR SCORE PROGRAM. b) COMPLIANT WITH THE VOC EMISSION
<br />LIMITS AND TESTING REQUIREMENTS SPECIFIED IN THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH’S 2010
<br />STANDARD METHOD FOR THE TESTING AND EVALUATION CHAMBERS, VERSION 1.1., FEBRUARY 2010. c)
<br />COMPLIANT WITH THE CALIFORNIA COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS (CA-CHPS)
<br />CRITERIA INTERPRETATION FOR EQ 2.2 DATED JULY 2012 AND LISTED IN THE CHPS HIGH PERFORMANCE
<br />PRODUCT DATABASE. d) COMPLIANT WITH CDPH CRITERIA AS CERTIFIED UNDER THE GREENGUARD
<br />CHILDREN’S AND SCHOOLS PROGRAM.
<br />19. ACOUSTICAL CONTROL: EMPLOY BUILDING ASSEMBLIES AND COMPONENTS WITH SOUND TRANSMISSION
<br />CLASS (STC) VALUES DETERMINED IN ACCORDANCE WITH ASTM E 90 AND ASTM E 413 OR OUTDOOR-INDOOR
<br />SOUND TRANSMISSION CLASS (OITC) DETERMINED IN ACCORDANCE WITH ASTM E 1332, USING EITHER THE
<br />PRESCRIPTIVE OR PERFORMANCE METHOD IN CAL GREEN SECTION 5.507.4.1 OR 5.507.4.2.
<br />20. INTERIOR SOUND TRANSMISSION: WALL AND FLOOR-CEILING ASSEMBLIES SEPARATING TENANT SPACES
<br />AND TENANT SPACES AND PUBLIC SPACES SHALL HAVE AN STC OF AT LEAST 40.
<br />21. NEW INSTALLATIONS OF HVAC, REFRIGERATION AND FIRE SUPPRESSION SYSTEMS SHALL NOT CONTAIN
<br />CHOLORFLUOROCARBONS (CFCs) OR HALONS.
<br />22. IN THE CITY OF Los Angeles, A LETTER FROM THE CONTRACTOR AND/OR THE BUILDING OWNER CERTIFYING
<br />WHAT MATERIALS IN NOTE #11 AND PAINTS IN NOTE #13 HAVE BEEN USED AND ITS COMPLIANCE WITH THE
<br />CODE MUST BE SUBMITTED TO THE BUILDING INSPECTOR.
<br />23. PROVIDE 208/240 V 40 AMP, GROUNDED AC OUTLET(S) IN THE PARKING AREA. THE NUMBER OF OUTLETS
<br />SHOULD TOTAL 5% OF THE TOTAL PROVIDED PARKING STALLS.
<br />24. PROVIDE METAL CONDUIT (1" MINIMUM) TERMINATION FOR FUTURE SOLAR USE. THE TERMINATION POINT
<br />SHALL BE LOCATED IN AN AREA DESIGNATED FOR FUTURE INSTALLATION OF ELECTRICAL SOLAR PANELS.
<br />25. THE CONDUIT FOR THE FUTURE ELECTRICAL SOLAR SYSTEM SHALL BE LABELED AS PER THE LOS ANGELES
<br />FIRE DEPARTMENT REQUIREMENTS.
<br />26. AFTER FUNCTIONAL PERFORMANCE TESTS ARE CONCLUDED, FOR GRN 24 SHALL BE COMPLETED AND
<br />READILY AVAILABLE TO THE FIELD INSPECTOR PRIOR TO FINAL APPROVAL.
<br />27. ALL OPERATIONAL ASPECTS OF THE BUILDING SHALL BE DOCUMENTED WITHIN A SYSTEMS MANUAL. THIS
<br />SYSTEMS MANUAL SHALL BE DELIVERED TO THE OWNER OR REPRESENTATIVE.
<br />28. THE TRAINING OF THE APPROPRIATE MAINTENANCE STAFF FOR EACH EQUIPMENT TYPE AND/OR SYSTEM
<br />SHALL BE DOCUMENTED IN THE COMMISSIONING REPORT.
<br />29. FORM GRN 25 SHALL BE COMPLETED AND READILY AVAILABLE TO THE FIELD INSPECTOR PRIOR TO FINAL
<br />APPROVAL.
<br />30. A COMPLETE COMMISSIONING REPORT AND FORM GRN 26 (COMPLETED) SHALL BE PROVIDED TO THE
<br />OWNER OR REPRESENTATIVE AND WILL BE READILY AVAILABLE TO THE FIELD INSPECTOR PRIOR TO THE
<br />FINAL APPROVAL.
<br />31. PROJECT WILL BE PROVIDED WITH OUTSIDE AIR VIA SUPPLY FANS WITH MERV-13 FILTERS.
<br />1. ANY FENESTRATION PRODUCT OR EXTERIOR DOOR, OTHER THAN FIELD-FABRICATED PRODUCTS, SHALL BE
<br />CERTIFIED AND LABELLED TO MEET THE FOLLOWING REQUIREMENTS PER E.E.S. SEC 116:
<br />AIR LEAKAGE: <0.3 CFM/SF
<br />'U' FACTOR: NFRC 100 OR PER TABLE 116-B (E.E.S.)
<br />SHGC: NFRC 200 OR PER TABLE 116-B (E.E.S.)
<br />2. FIELD FABRICATED FENESTRATION AND EXTERIOR DOORS SHALL COMPLY WITH U-FACTORS FROM TABLE
<br />116-A (E.E.S.) AND SHGC VALUES FROM TABLE 116-B (E.E.S.) & SHALL BE CAULKED BETWEEN THE PRODUCT
<br />AND THE BUILDING AND SHALL BE WEATHERSTRIPPED (EXCEPT UNFRAMED GLASS DOORS AND FIRE
<br />DOORS).
<br />3. JOINTS AND OTHER OPENINGS IN THE BUILDING ENVELOPE THAT ARE POTENTIAL SOURCES OF AIR LEAKAGE
<br />SHALL BE CAULKED, GASKETED, WEATHERSTRIPPED, OR OTHERWISE SEALED TO LIMIT INFILTRATION AND
<br />EXFILTRATION (SEC 117 E.E.S.)
<br />4. INSULATION PRODUCTS SHALL MEET THE CERTIFICATION REQUIREMENTS OF E.E.S. SEC 118 AND THE FLAME
<br />SPREAD RATING OF THE CBC. WHERE ROOF IS INSULATED, FIXED VENTS OR OPENINGS TO THE OUTDOORS
<br />OR TO UNCONDITIONED SPACES SHALL NOT BE INSTALLED. THE OPAQUE PORTIONS OF FRAMED DEMISING
<br />WALLS SHALL BE INSULATED WITH NO LESS THAN R13 INSULATION BETWEEN FRAMING MEMBERS.
<br />5. ROOFING PRODUCTS SHALL MEET THE SOLAR RELFECTANCE AND TERMAL EMITTANCE REQUIREMENTS OF
<br />E.E.S. SEC 118.
<br />60
<br />"
<br />
<br />A
<br />.
<br />F
<br />.
<br />F
<br />.
<br />MAXIMUM
<br />OCCUPANCY 51
<br />5/8"
<br />10"
<br />5
<br />5
<br />/
<br />8
<br />"
<br />1/2"
<br />3/8" -
<br />1/4" RADIUS, TYP.48
<br />"
<br />
<br />M
<br />I
<br />N
<br />
<br />A
<br />.
<br />F
<br />.
<br />F
<br />.
<br />TYP.
<br />
<br />
<br />1" MIN.
<br />NOTE: LETTERS & NUMBERS TO CONTRAST
<br />WITH BACKGROUND
<br />3/16" THK. ACRYLIC
<br />FLUSH MOUNTED
<br />TO WALL
<br />LOCATION: AT ROOMS OR SPACES WITH AN
<br />ASSEMBLY OCCUPANT LOAD OF 50 OR
<br />GREATER. SEE FIRE LIFE SAFETY DRAWINGS
<br />(R1.LS SERIES SHEETS) FOR OCCUPANT LOAD
<br />NUMBER DESIGNATION.
<br />3
<br />I
<br />N
<br />.
<br />
<br />M
<br />I
<br />N
<br />FIGURE 3007.7.5
<br />FIRE SERVICE ACCESS ELEVATOR SYMBOL
<br />A pictorial symbol of a standardized design designating which elevators are fire service access elevators shall be installed
<br />on each side of the hoistway door frame on the portion of the frame at right angles to the fire service access elevator
<br />lobby. The fire service access elevator symbol shall be designed as shown in Figure 3007.7.5 and shall comply with the
<br />following:
<br />1. The fire service access elevator symbol shall be not less than 3 inches (76 mm) in height.
<br />2. The vertical center line of the fire service access elevator symbol shall be centered on the hoistway door frame.
<br />Each symbol shall be not less than 78 inches (1981 mm), and not more than 84 inches (2134 mm) above the
<br />finished floor at the threshold.
<br />© Gensler
<br />Date Description
<br />Project Name
<br />Project Number
<br />Description
<br />Scale
<br />Seal / Signature
<br />2021
<br />Tel 949.863.9434
<br />Fax 949-553-1676
<br />4675 MacArthur Court
<br />Suite 100
<br />Newport Beach, CA
<br />92600
<br />USA
<br />As indicated
<br />11/18/2024 3:31:03 PM
<br />BIM 360://007.3757.000 - Caribou Industries - 3rd & Broadway/3RD-B_ARCH_WEST_R20.rvt
<br />R1.G0.012
<br />GENERAL NOTES
<br />07.3757.400
<br />3rd & Broadway Residential
<br />Tower Core & Shell
<br />301 N. Broadway, Santa Ana, CA
<br />1. EXCEPT AS OTHERWISE PROVIDED FOR IN THIS CODE, THE DESIGN, CONSTRUCTION,
<br />INSTALLATION, ALTERATION, REPAIR AND MAINTENANCE OF ELEVATORS AND CONVEYING
<br />SYSTEMS AND THEIR COMPONENTS SHALL CONFOR TO CALIFORNIA CODE OF REGULATIONS,
<br />TITLE 8, DIVISION 1, CHAPTER 4, SUBCHAPTER 6, ELEVATOR SAFETY ORDERS, ASME A90.1, ASME
<br />B20.1, AL I AL CTV, AND ASCE 24 FOR CONSTRUCTION IN FLOOD HAZARD AREAS ESTABLISHED IN
<br />SECTION 1612.3.
<br />2. ELEVATORS SHALL COMPLY WITH CBC SECTION 11B-407 AND WITH ASME A17.1. THEY SHALL
<br />BE PASSENGER ELEVATORS AS CLASSIFIED BY ASME A17.1. ELEVATOR OPERATION SHALL BE
<br />AUTOMATIC.
<br />3. WHEN THE ONLY ELEVATORS PROVIDED FOR USE BY THE PUBLIC AND EMPLOYEES ARE
<br />COMBINATION PASSENGER AND FREIGHT ELEVATORS, THEY SHALL COMPLY WITH CBC SECTION
<br />11B-407 AND WITH ASME A17.1.
<br />4. ELEVATOR LANDING REQUIREMENTS. ELEVATOR LANDINGS SHALL COMPLY WITH CBC
<br />SECTION 11B-407.2.
<br />a. HEIGHT: CALL BUTTONS AND KEYPADS SHALL BE LOCATED WITHIN ONE OF THE REACH
<br />RANGES SPECIFIED IN SECTION 11B-308, MEASURED TO THE CENTERLINE OF THE HIGHEST
<br />OPERABLE PART.
<br />b. SIZE AND SHAPE. CALL BUTTONS SHALL HAVE SQUARE SHOULDERS, BE ¾ INCH (19.1 MM)
<br />MINIMUM IN THE SMALLEST DIMENSION AND SHALL BE RAISED ⅛ INCH (3.2 MM) PLUS OR MINUS
<br />1/32 INCH (0.8 MM) ABOVE THE SURROUNDING SURFACE. THE BUTTONS SHALL BE ACTIVATED BY
<br />A MECHANICAL MOTION THAT IS DETECTABLE.
<br />c. CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR OR GROUND SPACE COMPLYING
<br />WITH SECTION 11B-305 SHALL BE PROVIDED AT CALL CONTROLS.
<br />d. LOCATION. THE CALL BUTTON THAT DESIGNATES THE UP DIRECTION SHALL BE LOCATED
<br />ABOVE THE CALL BUTTON THAT DESIGNATES THE DOWN DIRECTION. DESTINATION-ORIENTED
<br />ELEVATORS SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B407.2.1.4.
<br />e. SIGNALS. CALL BUTTONS SHALL HAVE VISIBLE SIGNALS THAT WILL ACTIVATE WHEN EACH
<br />CALL IS REGISTERED AND WILL EXTINGUISH WHEN EACH CALL IS ANSWERED. CALL BUTTONS
<br />SHALL BE INTERNALLY ILLUMINATED WITH A WHITE LIGHT OVER THE ENTIRE SURFACE OF THE
<br />BUTTON. DESTINATION-ORIENTED ELEVATORS SHALL NOT BE REQUIRED TO COMPLY WITH
<br />SECTION 11B407.2.1.5 PROVIDED THAT VISIBLE AND AUDIBLE SIGNALS COMPLYING WITH SECTION
<br />11B407.2.2, INDICATING WHICH ELEVATOR CAR TO ENTER, ARE PROVIDED.
<br />f. KEYPADS. WHERE KEYPADS ARE PROVIDED, KEYPADS SHALL BE IN A STANDARD
<br />TELEPHONE KEYPAD ARRANGEMENT AND SHALL COMPLY WITH SECTION 11B-407.4.7.2.
<br />g. HALL SIGNALS, INCLUDING IN-CAR SIGNALS, SHALL COMPLY WITH SECTION 11B407.2.2.
<br />h. VISIBLE AND AUDIBLE SIGNALS. A VISIBLE AND AUDIBLE SIGNAL SHALL BE PROVIDED AT
<br />EACH HOISTWAY ENTRANCE TO INDICATE WHICH CAR IS ANSWERING A CALL AND THE CAR’S
<br />DIRECTION OF TRAVEL. WHERE IN-CAR SIGNALS ARE PROVIDED, THEY SHALL BE VISIBLE FROM
<br />THE FLOOR AREA ADJACENT TO THE HALL CALL BUTTONS. VISIBLE AND AUDIBLE SIGNALS SHALL
<br />NOT BE REQUIRED AT EACH DESTINATION-ORIENTED ELEVATOR.
<br />i. WHERE A VISIBLE AND AUDIBLE SIGNAL COMPLYING WITH SECTION 11B-407.2.2 IS
<br />PROVIDED INDICATING THE ELEVATOR CAR DESIGNATION INFORMATION.
<br />j. VISIBLE SIGNALS. VISIBLE SIGNAL FIXTURES SHALL BE CENTERED AT 72 INCHES (1829 MM)
<br />MINIMUM ABOVE THE FINISH FLOOR OR GROUND. THE VISIBLE SIGNAL ELEMENTS SHALL BE A
<br />MINIMUM 2½ INCHES (64 MM) HIGH BY 2½ INCHES (64 MM) WIDE. SIGNALS SHALL BE VISIBLE FROM
<br />THE FLOOR AREA ADJACENT TO THE HALL CALL BUTTON. DESTINATION-ORIENTED ELEVATORS
<br />SHALL BE PERMITTED TO HAVE SIGNALS VISIBLE FROM THE FLOOR AREA ADJACENT TO THE
<br />HOISTWAY ENTRANCE.
<br />k. AUDIBLE SIGNALS. AUDIBLE SIGNALS SHALL SOUND ONCE FOR THE UP DIRECTION AND
<br />TWICE FOR THE DOWN DIRECTION, OR SHALL HAVE VERBAL ANNUNCIATORS THAT INDICATE THE
<br />DIRECTION OF ELEVATOR CAR TRAVEL. AUDIBLE SIGNALS SHALL HAVE A FREQUENCY OF 1500 HZ
<br />MAXIMUM. VERBAL ANNUNCIATORS SHALL HAVE A FREQUENCY OF 300 HZ MINIMUM AND 3000 HZ
<br />MAXIMUM. THE AUDIBLE SIGNAL AND VERBAL ANNUNCIATOR SHALL BE 10 DB MINIMUM ABOVE
<br />AMBIENT, BUT SHALL NOT EXCEED 80 DB, MEASURED AT THE HALL CALL BUTTON.
<br />l. HOISTWAY SIGNS. SIGNS AT ELEVATOR HOISTWAYS SHALL COMPLY WITH SECTION
<br />11B-407.2.3. FLOOR DESIGNATION. FLOOR DESIGNATIONS COMPLYING WITH SECTIONS 11B-703.2
<br />AND 11B-703.4.1 SHALL BE PROVIDED ON BOTH JAMBS OF ELEVATOR HOISTWAY ENTRANCES.
<br />FLOOR DESIGNATIONS SHALL BE PROVIDED IN BOTH RAISED CHARACTERS AND BRAILLE. RAISED
<br />CHARACTERS SHALL BE 2 INCHES (51 MM) HIGH. A RAISED STAR, PLACED TO THE LEFT OF THE
<br />FLOOR DESIGNATION, SHALL BE PROVIDED ON BOTH JAMBS AT THE MAIN ENTRY LEVEL. THE
<br />OUTSIDE DIAMETER OF THE STAR SHALL BE 2 INCHES (51 MM) AND ALL POINTS SHALL BE OF
<br />EQUAL LENGTH. RAISED CHARACTERS, INCLUDING THE STAR, SHALL BE WHITE ON A BLACK
<br />BACKGROUND. BRAILLE COMPLYING WITH SECTION 11B-703.3 SHALL BE PLACED BELOW THE
<br />CORRESPONDING RAISED CHARACTERS AND THE STAR. THE BRAILLE TRANSLATION FOR THE
<br />STAR SHALL BE “MAIN”. APPLIED PLATES ARE ACCEPTABLE IF THEY ARE PERMANENTLY FIXED TO
<br />THE JAMB.
<br />m. CAR DESIGNATIONS. DESTINATION-ORIENTED ELEVATORS SHALL PROVIDE TACTILE CAR
<br />IDENTIFICATION COMPLYING WITH SECTIONS 11B-703.2 AND 11B-703.4.1 ON BOTH JAMBS OF THE
<br />HOISTWAY IMMEDIATELY BELOW THE FLOOR DESIGNATION. CAR DESIGNATIONS SHALL BE
<br />PROVIDED IN BOTH RAISED CHARACTERS AND BRAILLE. RAISED CHARACTERS SHALL BE 2
<br />INCHES (51 MM) HIGH. RAISED CHARACTERS SHALL BE WHITE ON A BLACK BACKGROUND.
<br />BRAILLE COMPLYING WITH SECTION 11B-703.3 SHALL BE PLACED BELOW THE CORRESPONDING
<br />RAISED CHARACTERS. APPLIED PLATES ARE ACCEPTABLE IF THEY ARE PERMANENTLY FIXED TO
<br />THE JAMB.
<br />5. ELEVATOR DOOR REQUIREMENTS. HOISTWAY AND CAR DOORS SHALL COMPLY WITH
<br />SECTION 11B-407.3.
<br />a. TYPE. ELEVATOR DOORS SHALL BE THE HORIZONTAL SLIDING TYPE. CAR GATES SHALL
<br />BE PROHIBITED.
<br />b. OPERATION. ELEVATOR HOISTWAY AND CAR DOORS SHALL OPEN AND CLOSE
<br />AUTOMATICALLY. EXISTING MANUALLY OPERATED HOISTWAY SWING DOORS SHALL BE
<br />PERMITTED PROVIDED THAT THEY COMPLY WITH SECTIONS 11B-404.2.3 AND 11B-404.2.9. CAR
<br />DOOR CLOSING SHALL NOT BE INITIATED UNTIL THE HOISTWAY DOOR IS CLOSED.
<br />c. REOPENING DEVICE. ELEVATOR DOORS SHALL BE PROVIDED WITH A REOPENING DEVICE
<br />COMPLYING WITH SECTION 11B-407.3.3 THAT SHALL STOP AND REOPEN A CAR DOOR AND
<br />HOISTWAY DOOR AUTOMATICALLY IF THE DOOR BECOMES OBSTRUCTED BY AN OBJECT OR
<br />PERSON. EXISTING ELEVATORS WITH MANUALLY OPERATED DOORS SHALL NOT BE REQUIRED
<br />TO COMPLY WITH SECTION 11B-407.3.3.
<br />d. HEIGHT. THE DEVICE SHALL BE ACTIVATED BY SENSING AN OBSTRUCTION PASSING
<br />THROUGH THE OPENING AT 5 INCHES (127 MM) NOMINAL AND 29 INCHES (737 MM) NOMINAL
<br />ABOVE THE FINISH FLOOR.
<br />e. CONTACT. THE DEVICE SHALL NOT REQUIRE PHYSICAL CONTACT TO BE ACTIVATED,
<br />ALTHOUGH CONTACT IS PERMITTED TO OCCUR BEFORE THE DOOR REVERSES.
<br />f. DURATION. DOOR REOPENING DEVICES SHALL REMAIN EFFECTIVE FOR 20 SECONDS
<br />MINIMUM.
<br />g. DOOR AND SIGNAL TIMING. THE MINIMUM ACCEPTABLE TIME FROM NOTIFICATION THAT A
<br />CAR IS ANSWERING A CALL OR NOTIFICATION OF THE CAR ASSIGNED AT THE MEANS FOR THE
<br />ENTRY OF DESTINATION INFORMATION UNTIL THE DOORS OF THAT CAR START TO CLOSE SHALL
<br />BE CALCULATED FROM THE FOLLOWING EQUATION:
<br />T = D/(1.5 FT/S) OR T = D/(455 MM/S) = 5 SECONDS MINIMUM WHERE T EQUALS THE TOTAL TIME IN
<br />SECONDS AND D EQUALS THE DISTANCE (IN FEET OR MILLIMETERS) FROM THE POINT IN THE
<br />LOBBY OR CORRIDOR 60 INCHES (1524 MM) DIRECTLY IN FRONT OF THE FARTHEST CALL BUTTON
<br />CONTROLLING THAT CAR TO THE CENTERLINE OF ITS HOISTWAY DOOR.
<br />FOR CARS WITH IN-CAR LANTERNS, T SHALL BE PERMITTED TO BEGIN WHEN THE SIGNAL IS
<br />VISIBLE FROM THE POINT 60 INCHES (1524 MM) DIRECTLY IN FRONT OF THE FARTHEST HALL CALL
<br />BUTTON AND THE AUDIBLE SIGNAL IS SOUNDED.
<br />DESTINATION-ORIENTED ELEVATORS SHALL NOT BE REQUIRED TO COMPLY WITH SECTION
<br />11B-407.3.4.
<br />h. DOOR DELAY. ELEVATOR DOORS SHALL REMAIN FULLY OPEN IN RESPONSE TO A CAR
<br />CALL FOR 5 SECONDS MINIMUM.
<br />i. WIDTH. THE WIDTH OF ELEVATOR DOORS SHALL COMPLY WITH TABLE 11B-407.4.1. IN
<br />EXISTING ELEVATORS, A POWER-OPERATED CAR DOOR COMPLYING WITH SECTION 11B-404.2.3
<br />SHALL BE PERMITTED.
<br />6. ELEVATOR CAR REQUIREMENTS. ELEVATOR CARS SHALL COMPLY WITH SECTION 11B-407.4.
<br />a. CAR DIMENSIONS. INSIDE DIMENSIONS OF ELEVATOR CARS AND CLEAR WIDTH OF
<br />ELEVATOR DOORS SHALL COMPLY WITH TABLE 11B-407.4.1. IN EXISTING BUILDINGS, WHERE
<br />EXISTING SHAFT CONFIGURATION OR TECHNICAL INFEASIBILITY PROHIBITS STRICT COMPLIANCE
<br />WITH SECTION 11B-407.4.1, EXISTING ELEVATOR CAR CONFIGURATIONS THAT PROVIDE A CLEAR
<br />FLOOR AREA OF 18 SQUARE FEET (1.67 M2) MINIMUM AND ALSO PROVIDE AN INSIDE CLEAR
<br />DEPTH 54 INCHES (1372 MM) MINIMUM AND A CLEAR WIDTH 48 INCHES (1219 MM) MINIMUM SHALL
<br />BE PERMITTED.
<br />(INSERT TABLE 11B-407.4.1 ELEVATOR CAR DIMENSIONS)
<br />b. FLOOR SURFACES. FLOOR SURFACES IN ELEVATOR CARS SHALL COMPLY WITH
<br />SECTIONS 11B-302 AND 11B-303.
<br />c. PLATFORM TO HOISTWAY CLEARANCE. THE CLEARANCE BETWEEN THE CAR PLATFORM
<br />SILL AND THE EDGE OF ANY HOISTWAY LANDING SHALL BE 1¼ INCH (32 MM) MAXIMUM.
<br />d. LEVELING. EACH CAR SHALL BE EQUIPPED WITH A SELF-LEVELING FEATURE THAT WILL
<br />AUTOMATICALLY BRING AND MAINTAIN THE CAR AT FLOOR LANDINGS WITHIN A TOLERANCE OF ½
<br />INCH (12.7 MM) UNDER RATED LOADING TO ZERO LOADING CONDITIONS.
<br />e. ILLUMINATION. THE LEVEL OF ILLUMINATION AT THE CAR CONTROLS, PLATFORM, CAR
<br />THRESHOLD AND CAR LANDING SILL SHALL BE 5 FOOT CANDLES (54 LUX) MINIMUM.
<br />STAIR/EXIT/EGRESS SIGNAGEELEVATOR NOTES / DETAILS GENERAL NOTESCALGREEN NOTES
<br />ENERGY EFFICIENCY STDS
<br />DEFIBRILLATORS (AED'S)STORMWATER REQT'S
<br />f. ELEVATOR CAR CONTROLS. WHERE PROVIDED, ELEVATOR CAR CONTROLS
<br />SHALL COMPLY WITH SECTIONS 11B-407.4.6 AND 11B-309.4. IN EXISTING ELEVATORS,
<br />WHERE A NEW CAR OPERATING PANEL COMPLYING WITH SECTION 11B407.4.6IS
<br />PROVIDED, EXISTING CAR OPERATING PANELS MAY REMAIN OPERATIONAL AND
<br />SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-407.4.6.
<br />g. LOCATION. CONTROLS SHALL BE LOCATED WITHIN ONE OF THE REACH
<br />RANGES SPECIFIED IN SECTION 11B-308.
<br />h. WHERE THE ELEVATOR PANEL SERVES MORE THAN 16 OPENINGS AND A
<br />PARALLEL APPROACH IS PROVIDED, BUTTONS WITH FLOOR DESIGNATIONS SHALL BE
<br />PERMITTED TO BE 54 INCHES (1372 MM) MAXIMUM ABOVE THE FINISH FLOOR.
<br />i. IN EXISTING ELEVATORS, CAR CONTROL BUTTONS WITH FLOOR
<br />DESIGNATIONS SHALL BE PERMITTED TO BE LOCATED 54 INCHES (1372 MM) MAXIMUM
<br />ABOVE THE FINISH FLOOR WHERE A PARALLEL APPROACH IS PROVIDED.
<br />j. BUTTONS. CAR CONTROL BUTTONS WITH FLOOR DESIGNATIONS SHALL
<br />COMPLY WITH SECTION 11B407.4.6.2.
<br />i. SIZE AND SHAPE. BUTTONS SHALL HAVE SQUARE SHOULDERS, BE 3/4 INCH
<br />(19.1 MM) MINIMUM IN THEIR SMALLEST DIMENSION AND BE RAISED 1/8 INCH (3.2 MM)
<br />PLUS OR MINUS 1/32 INCH (0.8 MM) ABOVE THE SURROUNDING SURFACE.
<br />ii. ARRANGEMENT. BUTTONS SHALL BE ARRANGED WITH NUMBERS IN
<br />ASCENDING ORDER. WHEN TWO OR MORE COLUMNS OF BUTTONS ARE PROVIDED
<br />THEY SHALL READ FROM LEFT TO RIGHT.
<br />iii. ILLUMINATION. CAR CONTROL BUTTONS SHALL BE ILLUMINATED.
<br />iv. OPERATION. CAR CONTROL BUTTONS SHALL BE ACTIVATED BY A
<br />MECHANICAL MOTION THAT IS DETECTABLE.
<br />k. KEYPADS. CAR CONTROL KEYPADS SHALL BE IN A STANDARD TELEPHONE
<br />KEYPAD ARRANGEMENT AND SHALL COMPLY WITH SECTION 11B-407.4.7.2.
<br />l. EMERGENCY CONTROLS. EMERGENCY CONTROLS SHALL COMPLY WITH
<br />SECTION 11B407.4.6.4.
<br />i. HEIGHT. EMERGENCY CONTROL BUTTONS SHALL HAVE THEIR CENTERLINES
<br />35 INCHES (889 MM) MINIMUM ABOVE THE FINISH FLOOR.
<br />ii. LOCATION. EMERGENCY CONTROLS, INCLUDING THE EMERGENCY ALARM,
<br />SHALL BE GROUPED AT THE BOTTOM OF THE PANEL.
<br />7. DESIGNATIONS AND INDICATORS OF CAR CONTROLS. DESIGNATIONS AND
<br />INDICATORS OF CAR CONTROLS SHALL COMPLY WITH SECTION 11B-407.4.7. IN
<br />EXISTING ELEVATORS, WHERE A NEW CAR OPERATING PANEL COMPLYING WITH
<br />SECTION 11B407.4.7 IS PROVIDED, EXISTING CAR OPERATING PANELS MAY REMAIN
<br />OPERATIONAL AND SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-407.4.7.
<br />a. BUTTONS. CAR CONTROL BUTTONS SHALL COMPLY WITH SECTION
<br />11B-407.4.7.1.
<br />i. TYPE. CONTROL BUTTONS SHALL BE IDENTIFIED BY RAISED CHARACTERS OR
<br />SYMBOLS, WHITE ON A BLACK BACKGROUND, COMPLYING WITH SECTION 11B-703.2
<br />AND BRAILLE COMPLYING WITH SECTION 11B-703.3.
<br />ii. LOCATION. RAISED CHARACTERS OR SYMBOLS AND BRAILLE DESIGNATIONS
<br />SHALL BE PLACED IMMEDIATELY TO THE LEFT OF THE CONTROL BUTTON TO WHICH
<br />THE DESIGNATIONS APPLY.
<br />iii. SYMBOLS. THE CONTROL BUTTON FOR THE EMERGENCY STOP, ALARM,
<br />DOOR OPEN, DOOR CLOSE, MAIN ENTRY FLOOR, AND PHONE, SHALL BE IDENTIFIED
<br />WITH RAISED SYMBOLS AND BRAILLE AS SHOWN IN TABLE 11B-407.4.7.1.3.
<br />iv. VISIBLE INDICATORS. BUTTONS WITH FLOOR DESIGNATIONS SHALL BE
<br />PROVIDED WITH VISIBLE INDICATORS TO SHOW THAT A CALL HAS BEEN REGISTERED.
<br />THE VISIBLE INDICATION SHALL EXTINGUISH WHEN THE CAR ARRIVES AT THE
<br />DESIGNATED FLOOR.
<br />v. BUTTON SPACING. A MINIMUM CLEAR SPACE OF 3/8 INCH (9.5 MM) OR OTHER
<br />SUITABLE MEANS OF SEPARATION SHALL BE PROVIDED BETWEEN ROWS OF
<br />CONTROL BUTTONS.
<br />b. KEYPADS. KEYPADS SHALL BE IDENTIFIED BY CHARACTERS COMPLYING WITH
<br />SECTION 11B703.5AND SHALL BE CENTERED ON THE CORRESPONDING KEYPAD
<br />BUTTON. THE NUMBER FIVE KEY SHALL HAVE A SINGLE RAISED DOT. THE DOT SHALL
<br />BE 0.118 INCH (3 MM) TO 0.120 INCH (3.05 MM) BASE DIAMETER AND IN OTHER
<br />ASPECTS COMPLY WITH TABLE 11B-703.3.1.
<br />c. CAR POSITION INDICATORS. AUDIBLE AND VISIBLE CAR POSITION INDICATORS
<br />SHALL BE PROVIDED IN ELEVATOR CARS.
<br />i. VISIBLE INDICATORS. VISIBLE INDICATORS SHALL COMPLY WITH SECTION
<br />11B-407.4.8.1.
<br />ii. SIZE. CHARACTERS SHALL BE ½ INCH (12.7 MM) HIGH MINIMUM.
<br />iii. LOCATION. INDICATORS SHALL BE LOCATED ABOVE THE CAR CONTROL
<br />PANEL OR ABOVE THE DOOR.
<br />iv. FLOOR ARRIVAL. AS THE CAR PASSES A FLOOR AND WHEN A CAR STOPS AT A
<br />FLOOR SERVED BY THE ELEVATOR, THE CORRESPONDING CHARACTER SHALL
<br />ILLUMINATE. DESTINATION-ORIENTED ELEVATORS SHALL NOT BE REQUIRED TO
<br />COMPLY WITH SECTION 11B-407.4.8.1.3 PROVIDED THAT THE VISIBLE INDICATORS
<br />EXTINGUISH WHEN THE CALL HAS BEEN ANSWERED.
<br />v. DESTINATION INDICATOR. IN DESTINATION-ORIENTED ELEVATORS, A DISPLAY
<br />SHALL BE PROVIDED IN THE CAR WITH VISIBLE INDICATORS TO SHOW CAR
<br />DESTINATIONS.
<br />d. AUDIBLE INDICATORS. AUDIBLE INDICATORS SHALL COMPLY WITH SECTION
<br />11B-407.4.8.2.
<br />i. SIGNAL TYPE. THE SIGNAL SHALL BE AN AUTOMATIC VERBAL ANNUNCIATOR
<br />WHICH ANNOUNCES THE FLOOR AT WHICH THE CAR IS ABOUT TO STOP. FOR
<br />ELEVATORS OTHER THAN DESTINATION-ORIENTED ELEVATORS THAT HAVE A RATED
<br />SPEED OF 200 FEET PER MINUTE (1 M/S) OR LESS, A NON-VERBAL AUDIBLE SIGNAL
<br />WITH A FREQUENCY OF 1500 HZ MAXIMUM WHICH SOUNDS AS THE CAR PASSES OR
<br />IS ABOUT TO STOP AT A FLOOR SERVED BY THE ELEVATOR SHALL BE PERMITTED.
<br />ii. SIGNAL LEVEL. THE VERBAL ANNUNCIATOR SHALL BE 10 DB MINIMUM ABOVE
<br />AMBIENT, BUT SHALL NOT EXCEED 80 DB, MEASURED AT THE ANNUNCIATOR.
<br />iii. FREQUENCY. THE VERBAL ANNUNCIATOR SHALL HAVE A FREQUENCY OF 300
<br />HZ MINIMUM TO 3000 HZ MAXIMUM.
<br />8. EMERGENCY COMMUNICATION. EMERGENCY TWO-WAY COMMUNICATION
<br />SYSTEMS SHALL COMPLY WITH SECTION 11B-308. RAISED SYMBOLS OR
<br />CHARACTERS, WHITE ON A BLACK BACKGROUND, AND BRAILLE SHALL BE PROVIDED
<br />ADJACENT TO THE DEVICE AND SHALL COMPLY WITH SECTIONS 11B-703.2 AND
<br />11B-703.3. EMERGENCY TWO-WAY COMMUNICATION SYSTEMS BETWEEN THE
<br />ELEVATOR AND A POINT OUTSIDE THE HOISTWAY SHALL COMPLY WITH ASME A17.1.
<br />9. SUPPORT RAIL. SUPPORT RAILS SHALL BE PROVIDED ON AT LEAST ONE WALL OF
<br />THE CAR.
<br />a. LOCATION. CLEARANCE BETWEEN SUPPORT RAILS AND ADJACENT
<br />SURFACES SHALL BE 1½ INCHES (38 MM) MINIMUM. TOP OF SUPPORT RAILS SHALL BE
<br />31 INCHES (787 MM) MINIMUM TO 33 INCHES (838 MM) MAXIMUM ABOVE THE FLOOR OF
<br />THE CAR. THE ENDS OF THE SUPPORT RAIL SHALL BE 6 INCHES (152 MM) MAXIMUM
<br />FROM ADJACENT WALLS.
<br />b. SURFACES. SUPPORT RAILS SHALL BE SMOOTH AND ANY SURFACE
<br />ADJACENT TO THEM SHALL BE FREE OF SHARP OR ABRASIVE ELEMENTS.
<br />c. STRUCTURAL STRENGTH. ALLOWABLE STRESSES SHALL NOT BE EXCEEDED
<br />FOR MATERIALS USED WHEN A VERTICAL OR HORIZONTAL FORCE OF 250 POUNDS
<br />(1112 N) IS APPLIED AT ANY POINT ON THE SUPPORT RAIL, FASTENER, MOUNTING
<br />DEVICE, OR SUPPORTING STRUCTURE.
<br />10. EMERGENCY SIGNS: AN APPROVED PICTORIAL SIGN OF A STANDARDIZED DESIGN
<br />SHALL BE POSTED ADJACENT TO EACH ELEVATOR CALL STATION ON ALL FLOORS
<br />INSTRUCTING OCCUPANTS TO USE THE EXIT STAIRWAYS AND NOT TO USE THE
<br />ELEVATORS IN CASE OF FIRE. THE SIGN SHALL READ: “IN CASE OF FIRE, ELEVATORS
<br />ARE OUT OF SERVICE, USE EXIT STAIRS”. THE EMERGENCY SIGN SHALL NOT BE
<br />REQUIRED FOR ELEVATORS THAT ARE PART OF AN ACCESSIBLE MEANS OF EGRESS
<br />COMPLYING WITH CBC SECTION 1007.4. THE EMERGENCY SIGN SHALL NOT BE
<br />REQUIRED FOR ELEVATORS THAT ARE USED FOR OCCUPANT SELF-EVACUATION IN
<br />ACCORDANCE WITH CBC SECTION 3006.
<br />11. FIRE FIGHTER’S EMERGENCY OPERATION. ELEVATORS SHALL BE PROVIDED
<br />WITH PHASE I EMERGENCY RECALL OPERATION AND PHASE II EMERCENCY IN-CAR
<br />OPERATION IN ACCORDANCE WITH CALIFORNIA COED OF REGULATIONS, TITLE 8,
<br />DIVISION 1, CHAPTER 4, SUBCHAPTER 6, ELEVATOR SAFETY ORDERS.
<br />a. FLOOR NUMBERS. ELEVATOR HOISTWAYS SHALL HAVE A FLOOR NUMBER
<br />NOT LESS THAN 4 INCHES IN EHIGHT, PLACED ON THE WALLS AND/OR DOORS OF THE
<br />HOISTWAY AT INTERVALS SUCH THAT A PERSON IN A STALLED ELEVATOR, UPON
<br />OPENING THE CAR DOOR, CAN DETERMINE THE FLOOR POSITION.
<br />b. FIRE SIGNS. ALL AUTOMATIC ELEVATORS SHALL HAVE NOT LESS THAN ONE
<br />SIGN AT EACH LANDING PRINTED ON A CONTRASTING BACKGROUND IN LETTERS NOT
<br />LESS THAN ½ INCH HIGH TO READ: “IN CASE OF FIRE USE STAIRWAY FOR EXIT. DO
<br />NOT USE ELEVATOR”.
<br />c. CALL AND CAR OPERATION BUTTONS. AUTOMATIC PASSENGER ELEVATORS
<br />SHALL HAVE CALL AND OPERATION BUTTONS WITHIN 60 INCHES OF THE FLOOR.
<br />EMERGENCY TELEPHONES SHALL ALSO BE WITHIN 60 INCHES OF THE FLOOR.
<br />12. STANDARDIZED FIRE SERVICE ELEVATOR KEYS. ALL ELEVATORS SHALL BE
<br />EQUIPPED TO OPERATE WITH A STANDARDIZED FIRE SERVICE KEY IN ACCORDANCE
<br />WITH THE CALIFORNIA FIRE CODE.
<br />1. PERIMETER PROTECTION BMPS MUST BE INSTALLED AND MAINTAINED TO COMPLY WITH
<br />CONSTRUCTION STORM WATER BMP PERFORMANCE STANDARDS.
<br />2. SEDIMENT CONTROL BMPS MUST BE INSTALLED AND MAINTAINED TO COMPLY WITH
<br />CONSTRUCTION STORM WATER BMP PERFORMANCE STANDARDS.
<br />3. BMPS TO CONTROL SEDIMENT TRACKING MUST BE INSTALLED AND MAINTAINED AT
<br />ENTRANCES/EXITS TO COMPLY WITH CONSTRUCTION STORM WATER BMP PERFORMANCE
<br />STANDARDS.
<br />4. MATERIALS NEEDED TO INSTALL STANDBY BMPS NECESSARY TO COMPLETELY PROTECT THE
<br />EXPOSED PORTIONS OF THE SITE FROM EROSION, AND TO PREVENT SEDIMENT DISCHARGES, MUST
<br />BE STORED ON SITE. AREAS ALREADY PROTECTED FROM EROSION THROUGH IMPLEMENTATION
<br />OF PHYSICAL STABILIZATION OR ESTABLISHED VEGETATION STABILIZATION BMPS (AS DESCRIBED
<br />BELOW) ARE NOT CONSIDERED TO BE “EXPOSED”FOR PURPOSES OF THIS REQUIREMENT.
<br />5. DEPLOYMENT OF PHYSICAL OR VEGETATION EROSION CONTROL BMPS MUST COMMENCE AS SOON
<br />AS GRADING AND/OR EXCAVATION IS COMPLETED FOR ANY PORTION OF THE SITE. THE PROJECT
<br />PROPONENT MAY NOT CONTINUE TO RELY ON THE ABILITY TO DEPLOY STANDBY BMP MATERIALS
<br />TO PREVENT EROSION OF GRADED AREAS THAT HAVE BEEN COMPLETED.
<br />6. PROTECT AND STABILIZE ALL SLOPES DURING RAIN EVENTS.
<br />7. A WASHOUT AREA SHALL BE DESIGNATED AND MAINTAINED FOR MATERIALS SUCH AS CONCRETE,
<br />STUCCO, PAINT, CAULKING, SEALANTS, DRYWALL PLASTER, ETC.
<br />8. PROPERLY PROTECTED DESIGNATED STORAGE AREAS ARE REQUIRED FOR MATERIALS AND
<br />WASTES.
<br />9. TRASH AND DEBRIS SHALL BE REMOVED AND PROPERLY STORED OR DISPOSED OF DAILY.
<br />10. STORAGE, SERVICE, CLEANING AND MAINTENANCE AREAS FOR VEHICLES AND EQUIPMENT SHALL
<br />BE IDENTIFIED AND PROTECTED ACCORDINGLY.
<br />11. MATERIALS FOR SPILL CONTROL/CONTAINMENT MUST BE STOCKPILED ONSITE.
<br />12. NON-STORM WATER DISCHARGES MUST BE ELIMINATED OR CONTROLLED TO THE MAXIMUM
<br />EXTENT PRACTICABLE.
<br />MAX OCCUPANT LOAD SIGNAGE
<br />EMERGENCY COMMUNICATIONS
<br />EMERGENCY ELEVATOR COMMUNICATION SYSTEMS FOR THE DEAF, HARD OF HEARING AND SPEECH
<br />IMPAIRED. CBC 3001.2
<br />AN EMERGENCY TWO-WAY COMMUNICATION SYSTEM SHALL BE PROVIDED THAT:
<br />1. IS A VISUAL AND TEXT-BASED AND A VIDEO-BASED 24/7 LIVE INTERACTIVE SYSTEM.
<br />2. IS FULLY ACCESSIBLE BY THE DEAF, HARD OF HEARING AND SPEECH IMPAIRED, AND SHALL
<br />INCLUDE VOICE-ONLY OPTIONS FOR HEARING INDIVIDUALS.
<br />3. HAS THE ABILITY TO COMMUNICATE WITH EMERGENCY PERSONNEL UTILIZING EXISTING VIDEO
<br />CONFERENCING TECHNOLOGY, CHAT/TEXT SOFTWARE OR OTHER APPROVED TECHNOLOGY.
<br />STAIRWAY COMMUNICATION SYSTEM. CBC 403.5.3.1
<br />1. A TELEPHONE OR OTHER TWO-WAY COMMUNICATIONS SYSTEM CONNECTED TO AN APPROVED
<br />CONSTANTLY ATTENDED STATION SHALL BE PROVIDED AT NOT LESS THAN EVERY FIFTH FLOOR IN
<br />EACH STAIRWAY WHERE THE DOORS TO THE STAIRWAY ARE LOCKED.
<br />LUMINOUS EGRESS PATH MARKINGS. Approved luminous egress path markings delineating the exit path shall be
<br />provided with exception of the level of exit discharge in lobbies that serve as part of the exit path in accordance with
<br />Section 1028.1, Exception 1.
<br />MARKINGS WITHIN EXIT COMPONENTS. Egress path markings shall be provided in interior exit stairways, interior
<br />exit ramps and exit passageways, in accordance with Sections 1025.2.1 through 1025.2.6.
<br />UNIFORMITY. Placement and dimensions of markings shall be consistent and uniform throughout the same
<br />enclosure.
<br />SELF-LUMINOUS AND PHOTOLUMINESCENT. Luminous egress path markings shall be permitted to be made of
<br />any material, including paint, provided that an electrical charge is not required to maintain the required luminance.
<br />Such materials shall include, but not be limited to, self-luminous materials and photoluminescent materials. Materials
<br />shall comply with either of the standards as indicated in Section 1025.4.
<br />ILLUMINATION. Where photoluminescent exit path markings are installed, they shall be provided with not less than 1
<br />footcandle (11 lux) of illumination for not less than 60 minutes prior to periods when the building is occupied and
<br />continuously during occupancy.
<br />FIRE SERVICE ACCESS ELEV. SYMBOL
<br />09/21/2021 Issue for Plan Check
<br />A 12/10/2021 Reissue for Plan Check
<br />D 05/10/2022 Reissue for Plan Check
<br />F 07/11/2022 Reissue for Plan Check
<br />G 08/30/2022 Reissue for Plan Check
<br />H 06/17/2024 Revision to Permit
<br />J 11/22/2024 Reissue for Plan Check
<br />J
<br />1/7/25
|