Laserfiche WebLink
15 <br />" <br /> <br />T <br />O <br /> <br />4 <br />8 <br />" <br />2' <br />- <br />5 <br />" <br />5" <br />48 <br />" <br /> <br />T <br />O <br /> <br />6 <br />0 <br />" <br />6' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />CL <br />CL <br />CL <br />7 <br />5 <br />1 <br />S <br />8 <br />6 <br />2 <br />B <br />MAIN ENTRY FLOOR <br />DOOR CLOSED <br />DOOR OPEN EMERGENCY STOP <br />OCTAGON SYMBOL <br />SHALL BE RAISED <br />BUT THE "X" IS NOT <br />EMERGENCY ALARM <br />ELEVATOR LOBBY <br />ELEVATOR CONTROL PANEL <br />CENTER OPENING DOORS SIDE OPENING DOOR <br />80" MIN <br />54 <br />" <br /> <br />M <br />I <br />N <br />51 <br />" <br /> <br />M <br />I <br />N <br />68" MIN <br />51 <br />" <br /> <br />M <br />I <br />N <br />54 <br />" <br /> <br />M <br />I <br />N <br />42" MIN 36" MIN <br />INTERNATIONAL <br />"STAR OF LIFE" <br />SYMBOL <br />HALL <br />LANTERN <br />FLOOR LANDING NUMBERS ON <br />BOTH SIDES OF JAMB <br />HALL CALL BUTTONS <br />EMERGENCY SIGN <br />A <br />B <br />NOTE: THE <br />AUTOMATIC OPENING <br />DEVICE IS ACTIVATED <br />IF AN OBJECT PASSES <br />THROUGH EITHER <br />LINE A OR B. LINE A <br />AND LINE B <br />REPRESENT THE <br />VERTICAL LOCATIONS <br />OF THE DOOR <br />REOPENING DEVICE <br />NOT REQUIRING <br />CONTACT. <br />NOTE: ELEVATOR <br />CAR SHALL <br />ACCOMMODATE A <br />24"X84" GURNEY OR <br />STRETCHER <br />1-1/2" DIA. HANDRAIL, 1-1/2" FROM <br />WALL (1 MIN, REAR WALL <br />PREFERRED), 31-33" AFF (TYP) <br />ANY DOOR LOCATION <br />60" MIN <br />60 <br />" <br /> <br />M <br />I <br />N <br />36" MIN <br />ANY DOOR LOCATION <br />54" MIN <br />80 <br />" <br /> <br />M <br />I <br />N <br />36" MIN <br />5/8"MIN NUMERAL <br />HEIGHT <br />3/4" MIN CONTROL <br />BUTTON DIA <br />PE <br />R <br /> <br />C <br />B <br />C <br />SE <br />C <br />. <br /> <br />1 <br />1 <br />B <br />- <br />7 <br />0 <br />3 <br />. <br />4 <br />. <br />1 <br />2" <br />. <br />60 <br />" <br /> <br />A <br />. <br />F <br />. <br />F <br />. <br />REQUIRED EXIT SIGNS Tactile exit signs shall be required at the following locations: <br />1. Each grade-level exterior exit door that is required to comply with Section 1011.1, shall be identified by a tactile exit sign <br />with the word, “EXIT.” <br />2. Each exit door that is required to comply with Section 1011.1, and that leads directly to a grade-level exterior exit by <br />means of a stairway or ramp shall be identified by a tactile exit sign with the following words as appropriate: <br />2.1. “EXIT STAIR DOWN” 2.2. “EXIT RAMP DOWN” 2.3. “EXIT STAIR UP” 2.4. “EXIT RAMP UP” <br />3. Each exit door that is required to comply with Section 1011.1, and that leads directly to a grade-level exterior exit by <br />means of an exit enclosure or an exit passageway shall be identified by a tactile exit sign with the words, “EXIT ROUTE.” <br />4. Each exit access door from an interior room or area to a corridor or hallway that is required to comply with Section 1011.1, <br />shall be identified by a tactile exit sign with the words “EXIT ROUTE.” <br />5. Each exit door through a horizontal exit that is required to comply with Section 1011.1, shall be identified by a sign with the <br />words, “TO EXIT.” <br />6. Each door providing access to an area of refuge from an adjacent floor area shall be identified by a sign stating: "AREA <br />OF REFUGE". <br />7. Each door providing access to an exterior area for assisted rescue shall be identified by a sign stating: "EXTERIOR AREA <br />FOR ASSISTED RESCUE". <br />Raised character and Braille exit signs shall comply with Chapter 11B, Sections 11B-703.1, 11B-703.2, 11B-703.3 and <br />11B-703.5. <br />REQUIRED DIRECTIONAL SIGNAGE. Direction signage complying with Chapter 11B, Section 11B-703.5 indicating the <br />location of the other means of egress and which are accessible means of egress shall be provided at the following: <br /> <br />1. At exits serving a required accessible space but not providing an approved accessible means of egress. <br />2. At elevator landings. <br />3. Within areas of refuge <br />REQUIRED STAIR IDENTIFICATION SIGNS. A sign shall be provided at each floor landing in an interior exit stairway and <br />ramp connecting more than three stories designating the floor level, the terminus of the top and bottom of the interior exit <br />stairway and ramp and the identification of the stair or ramp. The signage shall also state the story of, and the direction to, <br />the exit discharge and the availability of roof access from the interior exit stairway and ramp for the fire department. The sign <br />shall be located 5 feet (1524 mm) <br />above the floor landing in a position that is readily visible when the doors are in the open and closed positions. <br />In addition to the stairway identification sign, raised characters and braille floor identification signs that comply with Chapter <br />11B. Sections 11B-703.1, 11B-703.2, 11B-703.3 and 11B-703.5 shall be located at the landing of each floor level, placed <br />adjacent to the door on the latch side, in all enclosed stairways in buildings two or more stories in height to identify the floor <br />level. At the exit discharge level, the sign shall include a raised five pointed star located to the left of the identifying floor <br />level. The outside diameter of the star shall be the same as the height of the raised characters. <br />1' <br />- <br />6 <br />" <br />1'-0" <br />TO EXIT <br />5/8" <br />10" <br />4" <br />3/ <br />8 <br />" <br /> <br />- <br /> <br />1 <br />/ <br />2 <br />" <br />1/4" RADIUS, TYP. <br />60 <br />" <br /> <br />M <br />A <br />X <br /> <br />A <br />. <br />F <br />. <br />F <br />. <br />48 <br />" <br /> <br />M <br />I <br />N <br /> <br />A <br />. <br />F <br />. <br />F <br />. <br />1. CONTRACTOR TO COMPLY WITH CODES, LAWS, ORDINANCES, RULES, AND REGULATIONS OF PUBLIC <br />AUTHORITIES GOVERNING THE <br />WORK. . <br />2. CONTRACTOR TO OBTAIN AND PAY FOR PERMITS AND INSPECTIONS REQUIRED BY PUBLIC AUTHORITIES <br />GOVERNING THE WORK. . <br />3. CONTRACTOR TO REVIEW DOCUMENTS, VERIFY DIMENSIONS AND FIELD CONDITIONS AND CONFIRM <br />THAT WORK IS BUILDABLE AS SHOWN. REPORT ANY CONFLICTS OR OMISSIONS TO THE ARCHITECT FOR <br />CLARIFICATION PRIOR TO PERFORMING ANY WORK IN <br />QUESTION. . <br />4. FOR SUBSTITUTIONS REFER TO <br />SPECIFICATIONS. . <br />5. CONTRACTOR TO COORDINATE WORK WITH THE OWNER, INCLUDING SCHEDULING TIME AND <br />LOCATIONS FOR DELIVERIES, BUILDING ACCESS, USE OF BUILDING SERVICES AND FACILITIES, AND USE <br />OF ELEVATORS. COORDINATE WORK WITH OTHER CONTRACTS. MINIMIZE DISTURBANCE OF BUILDING <br />FUNCTIONS AND OCCUPANTS, INCLUDING TRASH REMOVAL <br />ACCESS . . <br />6. OWNER WILL PROVIDE WORK NOTED "BY OTHERS" OR "NIC" UNDER SEPARATE CONTRACT. INCLUDE <br />SCHEDULE REQUIREMENTS IN CONSTRUCTION PROGRESS SCHEDULE AND COORDINATE TO ASSURE <br />ORDERLY SEQUENCE OF <br />INSTALLATION. . <br />7. CONTRACTOR TO COORDINATE TELECOMMUNICATIONS, DATA AND SECURITY SYSTEM <br />INSTALLATIONS. . <br /> . <br />8. CONTRACTOR TO MAINTAIN EXITS, EXIT LIGHTING, FIRE PROTECTIVE DEVICES, AND ALARMS IN <br />CONFORMANCE WITH CODES AND <br />ORDINANCES. . <br />9. CONTRACTOR TO PROTECT AREA OF WORK AND ADJACENT AREAS FROM DAMAGE. G.C. TO <br />COORDINATE TRASH <br />ACCESS. . <br />10. CONTRACTOR TO MAINTAIN WORK AREAS SECURE AND LOCKABLE DURING <br />CONSTRUCTION. . <br />11. DO NOT SCALE DRAWINGS. DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALES SHOWN ON <br />DRAWINGS. GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS, GRADES AND CONDITIONS AT SITE <br />PRIOR TO COMMENCING THE WORK, AND REPORT ANY DISCREPANCIES TO THE CONSTRUCTION <br />MANAGER IN <br />WRITING. . <br />12. PARTITIONS ARE DIMENSIONED FROM FINISH FACE TO FINISH FACE, UNLESS OTHERWISE NOTED. <br />MAINTAIN DIMENSIONS MARKED "CLEAR". ALLOW FOR THICKNESS OF <br />FINISHES. . <br />13. FLOOR LEVELS INDICATED ON DRAWINGS ARE FOR REFERENCE ONLY. PRIOR TO CONSTRUCTION <br />GENERAL CONTRACTOR SHALL HIRE A THIRD PARTY LICENSED SURVEYOR TO FIELD VERIFY EXISTING <br />GRADES AND FLOOR ELEVATIONS INDICATED ON DRAWING. NOTIFY ARCHITECT IMMEDIATELY OF ANY <br />DISCREPANCIES. . <br />14. WHERE EXISTING ACCESS PANELS CONFLICT WITH CONSTRUCTION. CONTRACTOR TO RELOCATE <br />PANELS TO ALIGN WITH AND FIT WITHIN NEW <br />CONSTRUCTION. . <br />15. CONTRACTOR TO UNDERCUT DOORS TO CLEAR TOP OF FLOOR FINISHES BY 1/4 INCH, UNLESS <br />OTHERWISE <br />NOTED. . <br />16. CEILING HEIGHT DIMENSIONS ARE TO FINISHED <br />SURFACES. . <br />17. CONTRACTOR SHALL PROVIDE CONSTRUCTION BARRICADES OR FENCING AS REQUIRED AND AS <br />APPROVED BY THE CITY FOR PUBLIC SAFETY PRIOR TO COMMENCING THE <br />WORK. . <br />18. CONTRACTOR TO COORDINATE AND PROVIDE BACKING FOR MILLWORK AND ITEMS ATTACHED OR <br />MOUNTED TO WALLS OR <br />CEILINGS. . <br />19. FIRE PROTECTION EQUIPMENT AND SERVICE ACCESS MUST BE PROVIDED DURING THE CONSTRUCTION <br />PERIOD AS REQUIRED BY THE <br />CITY. . <br />20. CONTRACTOR SHALL PROVIDE TEMPORARY EXIT SIGNS TO ASSURE A MEANS OF EGRESS DURING <br />CONSTRUCTION. . <br />21. WHERE A TYPICAL CONDITION IS DETAILED, IT SHALL BE UNDERSTOOD THAT ALL LIKE OR SIMILAR <br />CONDITIONS ARE THE SAME UNLESS SPECIFICALLY NOTED OR DETAILED <br />OTHERWISE. . <br />22. PUBLIC IMPROVEMENTS AND SERVICES ADJACENT TO THE SITE SHALL BE MAINTAINED DURING <br />CONSTRUCTION. APPROVAL OF THE CITY ENGINEERING DEPARTMENT IS REQUIRED BEFORE ANY WORK <br />IS COMMENCED. . <br />23. GENERAL CONTRACTOR SHALL COORDINATE SITE PLUMBING,DRAINAGE, ELECTRICAL, TELEPHONE <br />WORK AND EXISTING UTILITIES TO PROVIDE A COMPLETE OPERATING <br />SYSTEM. . <br />24. CONTRACTOR SHALL OBTAIN NECESSARY PERMITS FROM STATE OF CALIFORNIA, DIVISION OF <br />INDUSTRIAL SAFETY, OSHA DEPARTMENT, FOR WORK ON BUILDINGS OVER 36'-0" IN <br />HEIGHT. . <br />25. EXCEPT WHERE SHOWN IN DIMENSIONAL DETAIL, THE LOCATIONS OF PLUMBING, MECHANICAL <br />EQUIPMENT, DUCTS, PIPING, AND FITTING ARE ONLY APPROXIMATE. THE EXACT LOCATIONS SHALL BE <br />DETERMINED BY THE CONTRACTOR, SUBJECT TO APPROVAL BY THE <br />ARCHITECT. . <br />26. CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL MECHANICAL EQUIPMENT PADS AND BASES <br />AS WELL AS POWER AND WATER OR DRAIN INSTALLATIONS WITH EQUIPMENT MANUFACTURERS <br />BEFORE PROCEEDING WITH THE WORK. CHANGES TO ACCOMMODATE FIELD CONDITIONS OR <br />SUBSTITUTIONS SHALL BE MADE AT NO ADDITIONAL <br />COST. . <br />27. CONTRACTOR SHALL VERIFY SIZE AND LOCATION OF ALL MECHANICAL OPENINGS THROUGH THE ROOF <br />WITH MECHANICAL EQUIPMENT <br />MANUFACTURERS. <br />. <br />28. CONTRACTOR SHALL PROVIDE AND INSTALL ALL STIFFENERS, BRACING, BLOCKING, BACK-UP PLATES <br />AND SUPPORTING BRACKETS REQUIRED FOR THE INSTALLATION OF ALL CASEWORK, TOILET ROOM <br />ACCESSORIES, FIXTURES AND PARTITIONS AND ALL WALL MOUNTED OR SUSPENDED MECHANICAL, <br />ELECTRICAL OR MISCELLANEOUS EQUIPMENT AND <br />FURNISHINGS. . <br />29. MECHANICAL SUPPLY AND RETURN AIR SHAFTS SHALL BE AIRTIGHT AND <br />SEALED. . <br />30. ALL WORK PERFORMED SHALL COMPLY WITH THE CONTRACT DOCUMENTS, DRAWINGS AND <br />SPECIFICATIONS, INCLUDING THESE GENERAL NOTES. THE CONTRACTOR SHALL COORDINATE THE <br />INTENT OF THE GENERAL NOTES WITH ALL <br />TRADES . <br />31. SPECIFICATIONS, BOUND SEPARATELY, ARE PART OF THE CONTRACT <br />DOCUMENTS. . <br />32. THE ORGANIZATION OF THE DRAWINGS AND SPECIFICATIONS SHALL NOT CONTROL THE CONTRACTOR <br />IN DIVIDING THE WORK AMONG SUBCONTRACTORS OR IN ESTABLISHING THE EXTENT OF WORK TO BE <br />PERFORMED BY ANY <br />TRADE. . <br />33. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE DRAWINGS AND SPECIFICATIONS. IF <br />CONFLICT IS FOUND BETWEEN DRAWINGS, GENERAL NOTES AND SPECIFICATIONS, CONSULT THE <br />ARCHITECT FOR CLARIFICATION BEFORE PROCEEDING WITH THE <br />WORK. . <br />34. NO DEVIATION FROM CONTRACT DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT WRITTEN <br />APPROVAL OF THE ENGINEER AND/OR <br />ARCHITECT. . <br />35. THE STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS ARE SUPPLEMENTARY TO THE <br />ARCHITECTURAL DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO CHECK WITH <br />THE ARCHITECTURAL DRAWINGS BEFORE THE INSTALLATION OF STRUCTURAL, MECHANICAL AND <br />ELECTRICAL WORK. SHOULD THERE BE A DISCREPANCY BETW EEN THE ARCHITECTURAL DRAWINGS <br />AND THE CONSULTING ENGINEERS' DRAWINGS THAT WOULD CAUSE AN AWKWARD INSTALLATION, IT <br />SHALL BE BROUGHT TO THE ENGINEER'S ATTENTION FOR CLARIFICATION PRIOR TO INSTALLATION OF <br />SAID WORK. ANY WORK INSTALLED IN CONFLICT WITH THE ARCHITECTURAL DRAWINGS SHALL BE <br />CORRECTED BY THE CONTRACTOR AT NO ADDITIONAL <br />COST. . <br />36. CONTRACTOR SHALL OBTAIN NECESSARY PERMITS FROM STATE OF CALIFORNIA, DIVISION OF <br />INDUSTRIAL SAFETY, OSHA DEPARTMENT, FOR TRENCHES OR EXCAVATIONS GREATER THAN 5'-0" DEEP <br />INTO WHICH A PERSON IS REQUIRED TO DESCEND FOR CONSTRUCTION <br />PURPOSES. . <br />37. CONTRACTOR SHALL AS NECESSARY PROVIDE SHORING DESIGNED AND DETAILED BY A CALIFORNIA <br />REGISTERED <br />ENGINEER. . <br />38. DOORS OPENING INTO REQUIRED 1-HOUR, FIRE-RESISTIVE CORRIDORS SHALL BE PROTECTED WITH A <br />SMOKE OR DRAFT STOP ASSEMBLY HAVING A 20-MINUTE RATING AND SHALL BE SELF- <br />CLOSING. . <br />39. 20-MINUTE DOOR JAMBS TO BE TIGHT-FITTING, SMOKE AND DRAFT <br />CONTROLLED. . <br />40. EXIT DOORS SHALL SWING IN THE DIRECTION OF TRAVEL WHEN SERVING 50 OR MORE PERSONS AND IN <br />ANY HAZARDOUS <br />AREA. . <br />41. PROVIDE FIRE DAMPERS OR DOORS WHERE AIR DUCTS PENETRATE FIRE-RATED WALLS OR <br />CEILINGS. . <br />42. WOOD BLOCKING SHALL BE FIRE TREATED IN ACCORDANCE WITH APPLICABLE CODE <br />REQUIREMENTS. . <br />43. IF THE SPACE ABOVE THE SUSPENDED CEILING IS USED AS A RETURN AIR PLENUM, THEN ALL <br />EQUIPMENT AND WIRING(COMMUNICATION, POWER ETC) SHALL BE LISTED FOR INSTALLATION IN A <br />PLENUM. . <br />44. ALL FLEXIBLE AIRDUCTS, IF USED, SHALL MEET THE REQUIREMENTS OF NFPA 90A, 2-3-2 IN <br />CONSTRUCTION AND <br />INSTALLATION. . <br />45. PROVIDE ALL ACCESS PANELS REQUIRED FOR ALL JUNCTION BOXES, VALVES, CLEANOUTS, PLUGS, <br />FILTERS, EQUIPMENT AND ALL OTHER ITEMS REQUIRING SERVICE AND MAINTENANCE <br />1. AUTOMATIC EXTERNAL DEFIBRILLATORS (AED’S) SHALL BE DESIGNED AND LOCATED UNDER THE <br />TENANT IMPROVEMENT PERMIT. AED’S SHALL BE INSTALLED AND MEET THE REQUIREMENTS BELOW <br />PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY. <br />2. AED'S ARE REQUIRED IN NEW BUILDINGS AND TENANT SPACES IN SHELL BUILDINGS WHEN THE <br />OCCUPANT LOAD WITHIN THE BUILDINGS WHEN THE OCCUPANT LOAD WITHIN THE BUILDING OR THE <br />OCCUPANT LOAD WITHIN AN OCCUPANCY OR TENANT SPACES EXCEEDS THE OCCUPANT LOADS IN <br />TABLE 145-3910 OF THE MUNICIPAL CODE. (SECT. 145.3910 (A)) <br />3. AED'S SHALL BE CONSPICUOUSLY PLACED AND READILY ACCESSIBLE IN THE EVENT OF AN EMERGENCY. <br />AED'S SHALL BE MOUNTED SUCH THAT THE TOP OF THE AED IS NO MORE THAN FIVE (5) FEET ABOVE <br />FLOOR LEVEL. <br />4. WHEN REQUIRED TO BE LOCATED ON THE FLOOR LEVEL OF THE BUILDING PURSUANT TO SECTION <br />145.3910 AND TABLE 145-3910, ONE AED SHALL BE PLACED AT THE MAIN ENTRANCE OF EVERY FLOOR <br />REQUIRED TO HAVE ONE OR MORE AED'S. (SEC. 145.3915 (B) 1) <br />5. WHEN NOT REQUIRED ON EVERY FLOOR OF A BUILDING PURSUANT TO SECTION 145.3910 AND TABLE <br />145-3910, AED'S SHALL BE LOCATED SUCH THAT THE LENGTH OF VERTICAL TRAVEL BETWEEN ANY TWO <br />ON ANY TWO FLOORS WITH AN AED SHALL NOT EXCEED 450 FEET. (SEC. 145.3915 ( C ) 2) <br />6. THE BUILDING OWNER SHALL REGISTER AED(S), AT THE TIME IT IS ACQUIRED, WITH THE CITY OF Los <br />Angeles FIRE-RESCUE DEPARTMENT AND SHALL IDENTIFY THE EXISTENCE OF AED, LOCATION, AND TYPE <br />OF AED. <br />7. PRIOR TO FINAL OCCUPANCY THE BUILDING OWNER SHALL PROVIDE TO THE SATISFACTION OF THE <br />FIRE-RESCUE DEPARTMENT WRITTEN VALIDATION AND PRESCRIPTION FOR USE OF THE AED (S) IS <br />SECURED BY TRAINED INDIVIDUALS FROM A PRESCRIBING PHYSICIAN. <br />8. TRAINED EMPLOYEES SHALL BE MADE AVAILABLE WITHIN THE BUILDING TO RESPOND TO AN <br />EMERGENCY DURING NORMAL OPERATING HOURS. <br />THE BUILDING OWNER SHALL BE RESPONSIBLE SHALL REPORT TO THE FIRE-RESCUE DEPARTMENT <br />TENANTS ANNUAL RECEIPT OF AN AMERICAN HEART ASSOCIATION OR AMERICAN RED CROSS APPROVED <br />BROCHURE ON THE PROPER USE OF AN AED ALSO POSTED NEXT TO ALL AED'S, AND TENANT NOTIFICATION <br />OF THE LOCATION OF ALL AED'S IN THE BUILDING. <br />1. STORM WATER POLLUTION CONTROL PREVENTION: COMPLY WITH LOCAL STORM WATER MANAGEMENT AND <br />EROSION CONTROL ORDINANCES. Los Angeles MUNICIPAL CODE, CHAPTER 4, ARTICLE 3, DIVISION 3. <br />2. LIGHT POLLUTION REDUCTION: COMPLY WITH LOCAL LIGHT POLLUTION CONTROL ORDINANCE. Los Angeles <br />MUNICIPAL CODE 142.0740. <br />3. PLUMBING FIXTURES SHALL MEET THE MAXIMUM FLOW RATE VALUES SHOWN IN CALIFORNIA GREEN <br />BUILDING CODE TABLE 5.503.3. <br />4. WATER CLOSETS SHALL NOT EXCEED 1.28 GALLONS PER FLUSH. TANK TYPE TOILETS SHALL BE CERTIFIED <br />TO THE PERFORMANCE CRITERIA OF THE US EPA WATERSENSE SPECIFICATION. <br />5. URINALS SHALL NOT EXCEED 0.5 GALLONS PER FLUSH. <br />6. SINGLE SHOWER HEADS SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE THAN 2.0 GALLONS PER MINUTE <br />AT 80 PSI. <br />7. WHERE THERE ARE MULTIPLE SHOWER HEADS SERVING ONE SHOWER AND CONTROLLED BY A SINGLE <br />VALVE, THE COMBINED FLOW RATE OF ALL SHOWERHEADS SHALL NOT EXCEED 2.0 GALLONS PER MINUTE AT <br />80 PSI. <br />8. CONSTRUCTION WASTE MANAGEMENT SHALL COMPLY WITH LOCAL ORDINANCES. Los Angeles MUNICIPAL <br />CODE, CHAPTER 6, ARTICLE 6. <br />9. PROVIDE READILY ACCESSIBLE RECYCLING AREAS FOR BUILDING OCCUPANTS PER LOCAL ORDINANCE. Los <br />Angeles MUNICIPAL CODE, CHAPTER 6, ARTICLE 6 AND CHAPTER 14, ARTICLE 2, DIVISION 8. <br />10. COVERING OF DUCT OPENINGS AND PROTECTION OF MECHANICAL EQUIPMENT DURING CONSTRUCTION: AT <br />THE TIME OF ROUGH INSTALLATION AND DURING STORAGE ON THE CONSTRUCTION SITE UNTIL FINAL <br />STARTUP OF THE HVAC EQUIPMENT, ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT <br />OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, SHEET METAL OR OTHER METHODS ACCEPTABLE TO <br />THE ENFORCING AGENCY TO REDUCE THE AMOUNT OF DUST, WATER AND DEBRIS WHICH MAY ENTER THE <br />SYSTEM. <br />11. ADHESIVES, ADHESIVE BONDING PRIMERS, ADHESIVE PRIMERS, SEALANTS, SEALANT PRIMERS AND CAULKS <br />SHALL COMPLY WITH LOCAL OR REGIONAL AIR POLLUTION CONTROL OR AIR QUALITY MANAGEMENT <br />DISTRICT RULES WHERE APPLICABLE, OR SCAQMD RULE 1168 VOC LIMITS AS SHOWN IN CAL GREEN TABLES <br />5.504.4.1 AND 5.504.4.2. SUCH PRODUCTS ALSO SHALL COMPLY WITH RULE 1168 PROHIBITION ON THE USE OF <br />CERTAIN TOXIC COMPOUNDS (CHOLORFORM, ETHYLENE DICHLORIDE, METHYLLENE CHLORIDE, <br />PERCHLOROETHYLENE AND TRICHLOROETHYLENE). <br />12. AEROSOL ADHESIVES, AND SMALLER UNIT SIZES OF ADHESIVES, AND SEALANT OR CAULKING COMPOUNDS <br />(IN UNITS OF PRODUCT, LESS PACKAGING, WHICH DO NOT WEIGH MORE THAN ONE POUND AND DO NOT <br />CONSIST OF MORE THAN 16 FLUID OUNCES) SHALL COMPLY WITH STATEWIDE VOC STANDARDS AND OTHER <br />REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN TOXIC COMPOUNDS, OF CALIFORNIA CODE <br />OF REGULATIONS, TITLE 17, COMMENCING WITH SECTION 94507. <br />13. ARCHITECTURAL PAINTS AND COATINGS SHALL COMPLY WITH VOC LIMITS IN TABLE 1 OF THE ARB <br />ARCHITECTURAL COATINS SUGGESTED CONTROL MEASURE, AS SHOWN IN CAL GREEN TABLE 5.504.4.3, <br />UNLESS MORE STRINGENT LOCAL LIMITS APPLY. THE VOC CONTENT LIMIT FOR COATING THAT DO NOT MEET <br />THE DEFINITIONS FOR THE SPECIALTY COATINGS CATEGORIES LISTED IN TABLE5.504.4.3 SHALL BE <br />DETERMINED BY CLASSIFYING THE COATING AS A FLAT, NONFLAT OR NONFLAT-HIGH GLOSS COATING, <br />BASED ON ITS GLOSS, AS DEFINED IN SUBSECTIONS 4.21, 4.36 AND 4.37 OF THE 2007 CALIFORNIA AIR <br />RESOURCE BOARD SUGGESTED CONTROL MEASURE, AND THE CORRESPONDING FLAT, NONFLAT OR <br />NONFLAT-HIGH GLOSS VOC LIMIT IN TABLE 5.504.4.3, SHALL APPLY. <br />14. AEROSOL PAINTS AND COATINGS SHALL MEET THE PWMIR LIMITS FOR ROC IN SECTION 94522(a)(3) AND <br />OTHER REQUIRMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN TOXIC COMPOUNDS AND OZONE <br />DEPLETING SUBSTANCES, IN SECTIONS 94522(c)(2) AND (d)(2) OF CALIFORNIA CODE OF REGULATIONS, TITLE <br />17, COMMENCING WITH SECTION 94520. <br />15. ALL CARPET INSTALLED IN BUILDING INTERIORS SHALL MEET AT LEAST ONE OF THE FOLLOWING <br />REQUIREMENTS: a) CARPET AND RUG INSTITUTE’S GREEN LABEL PLUS PROGRAM. b) COMPLIANT WITH <br />THE VOC EMISSION LIMITS AND TESTING REQUIREMENTS SPECIFIED IN THE CALIFORNIA DEPARTMENT OF <br />PUBLIC HEALTH STANDARD METHOD FOR THE TESTING AND EVALUATION OF VOLATILE ORGANIC CHEMICAL <br />EMISSIONS FOR INDOOR SOURCES USING ENVIRONMENTAL CHAMBERS, VERSION 1.1., FEBRUARY 2010. c) <br />NSF/ANSI 140 AT THE GOLD LEVEL OR HIGHER. d) SCIENTIFIC CERTIFICATIONS SYSTEM SUSTAINABLE <br />CHOICE. e) COMPLIANT WITH THE CALIFORNIA COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS (CA- <br />CHPS) CRITERIA INTERPRETATION FOR EQ 2.2 DATED JULY 2012 AND LISTED IN THE CHPS HIGH <br />PERFORMANCE PRODUCT DATABASE. <br />16. ALL CARPET CUSHION INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE REQUIREMENTS OF THE <br />CARPET AND RUG INSTITUTES’S GREEN LABEL PROGRAM. <br />17. HARDWOOD PLYWOOD, PARTICLE BOARD AND MEDIUM DENSITY FIBERBOARD COMPOSITE WOOD <br />PRODUCTS USED ON THE INTERIOR OR EXTERIOR OF THE BUILDING SHALL MEET THE REQUIREMENTS FOR <br />FORMALDEHYDE AS SPECIFIED IN THE ARB’S AIR TOXICS CONTROL MEASURE (ACTM) FOR COMPOSITE <br />WOOD (17 CCR 93120 ET SEQ.) THOSE MATERIALS NOT EXEMPTED UNDER THE ACTM MUST MEET THE <br />SPECIFIED EMISSION LIMITS, AS SHOWN IN CAL GREEN TABLE 5.504.4.5. <br />18. RESILIENT FLOORING SYSTEMS: FOR 80 PERCENT OF FLOOR AREA RECEIVING RESILIENT FLOORING, <br />INSTALLED RESILIENT FLOORING SHALL MEET ONE OF THE FOLLOWING: a) CERTIFIED UNDER THE RESILIENT <br />FLOOR COVERING INSTITUTE (RFCI) FLOOR SCORE PROGRAM. b) COMPLIANT WITH THE VOC EMISSION <br />LIMITS AND TESTING REQUIREMENTS SPECIFIED IN THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH’S 2010 <br />STANDARD METHOD FOR THE TESTING AND EVALUATION CHAMBERS, VERSION 1.1., FEBRUARY 2010. c) <br />COMPLIANT WITH THE CALIFORNIA COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS (CA-CHPS) <br />CRITERIA INTERPRETATION FOR EQ 2.2 DATED JULY 2012 AND LISTED IN THE CHPS HIGH PERFORMANCE <br />PRODUCT DATABASE. d) COMPLIANT WITH CDPH CRITERIA AS CERTIFIED UNDER THE GREENGUARD <br />CHILDREN’S AND SCHOOLS PROGRAM. <br />19. ACOUSTICAL CONTROL: EMPLOY BUILDING ASSEMBLIES AND COMPONENTS WITH SOUND TRANSMISSION <br />CLASS (STC) VALUES DETERMINED IN ACCORDANCE WITH ASTM E 90 AND ASTM E 413 OR OUTDOOR-INDOOR <br />SOUND TRANSMISSION CLASS (OITC) DETERMINED IN ACCORDANCE WITH ASTM E 1332, USING EITHER THE <br />PRESCRIPTIVE OR PERFORMANCE METHOD IN CAL GREEN SECTION 5.507.4.1 OR 5.507.4.2. <br />20. INTERIOR SOUND TRANSMISSION: WALL AND FLOOR-CEILING ASSEMBLIES SEPARATING TENANT SPACES <br />AND TENANT SPACES AND PUBLIC SPACES SHALL HAVE AN STC OF AT LEAST 40. <br />21. NEW INSTALLATIONS OF HVAC, REFRIGERATION AND FIRE SUPPRESSION SYSTEMS SHALL NOT CONTAIN <br />CHOLORFLUOROCARBONS (CFCs) OR HALONS. <br />22. IN THE CITY OF Los Angeles, A LETTER FROM THE CONTRACTOR AND/OR THE BUILDING OWNER CERTIFYING <br />WHAT MATERIALS IN NOTE #11 AND PAINTS IN NOTE #13 HAVE BEEN USED AND ITS COMPLIANCE WITH THE <br />CODE MUST BE SUBMITTED TO THE BUILDING INSPECTOR. <br />23. PROVIDE 208/240 V 40 AMP, GROUNDED AC OUTLET(S) IN THE PARKING AREA. THE NUMBER OF OUTLETS <br />SHOULD TOTAL 5% OF THE TOTAL PROVIDED PARKING STALLS. <br />24. PROVIDE METAL CONDUIT (1" MINIMUM) TERMINATION FOR FUTURE SOLAR USE. THE TERMINATION POINT <br />SHALL BE LOCATED IN AN AREA DESIGNATED FOR FUTURE INSTALLATION OF ELECTRICAL SOLAR PANELS. <br />25. THE CONDUIT FOR THE FUTURE ELECTRICAL SOLAR SYSTEM SHALL BE LABELED AS PER THE LOS ANGELES <br />FIRE DEPARTMENT REQUIREMENTS. <br />26. AFTER FUNCTIONAL PERFORMANCE TESTS ARE CONCLUDED, FOR GRN 24 SHALL BE COMPLETED AND <br />READILY AVAILABLE TO THE FIELD INSPECTOR PRIOR TO FINAL APPROVAL. <br />27. ALL OPERATIONAL ASPECTS OF THE BUILDING SHALL BE DOCUMENTED WITHIN A SYSTEMS MANUAL. THIS <br />SYSTEMS MANUAL SHALL BE DELIVERED TO THE OWNER OR REPRESENTATIVE. <br />28. THE TRAINING OF THE APPROPRIATE MAINTENANCE STAFF FOR EACH EQUIPMENT TYPE AND/OR SYSTEM <br />SHALL BE DOCUMENTED IN THE COMMISSIONING REPORT. <br />29. FORM GRN 25 SHALL BE COMPLETED AND READILY AVAILABLE TO THE FIELD INSPECTOR PRIOR TO FINAL <br />APPROVAL. <br />30. A COMPLETE COMMISSIONING REPORT AND FORM GRN 26 (COMPLETED) SHALL BE PROVIDED TO THE <br />OWNER OR REPRESENTATIVE AND WILL BE READILY AVAILABLE TO THE FIELD INSPECTOR PRIOR TO THE <br />FINAL APPROVAL. <br />31. PROJECT WILL BE PROVIDED WITH OUTSIDE AIR VIA SUPPLY FANS WITH MERV-13 FILTERS. <br />1. ANY FENESTRATION PRODUCT OR EXTERIOR DOOR, OTHER THAN FIELD-FABRICATED PRODUCTS, SHALL BE <br />CERTIFIED AND LABELLED TO MEET THE FOLLOWING REQUIREMENTS PER E.E.S. SEC 116: <br />AIR LEAKAGE: <0.3 CFM/SF <br />'U' FACTOR: NFRC 100 OR PER TABLE 116-B (E.E.S.) <br />SHGC: NFRC 200 OR PER TABLE 116-B (E.E.S.) <br />2. FIELD FABRICATED FENESTRATION AND EXTERIOR DOORS SHALL COMPLY WITH U-FACTORS FROM TABLE <br />116-A (E.E.S.) AND SHGC VALUES FROM TABLE 116-B (E.E.S.) & SHALL BE CAULKED BETWEEN THE PRODUCT <br />AND THE BUILDING AND SHALL BE WEATHERSTRIPPED (EXCEPT UNFRAMED GLASS DOORS AND FIRE <br />DOORS). <br />3. JOINTS AND OTHER OPENINGS IN THE BUILDING ENVELOPE THAT ARE POTENTIAL SOURCES OF AIR LEAKAGE <br />SHALL BE CAULKED, GASKETED, WEATHERSTRIPPED, OR OTHERWISE SEALED TO LIMIT INFILTRATION AND <br />EXFILTRATION (SEC 117 E.E.S.) <br />4. INSULATION PRODUCTS SHALL MEET THE CERTIFICATION REQUIREMENTS OF E.E.S. SEC 118 AND THE FLAME <br />SPREAD RATING OF THE CBC. WHERE ROOF IS INSULATED, FIXED VENTS OR OPENINGS TO THE OUTDOORS <br />OR TO UNCONDITIONED SPACES SHALL NOT BE INSTALLED. THE OPAQUE PORTIONS OF FRAMED DEMISING <br />WALLS SHALL BE INSULATED WITH NO LESS THAN R13 INSULATION BETWEEN FRAMING MEMBERS. <br />5. ROOFING PRODUCTS SHALL MEET THE SOLAR RELFECTANCE AND TERMAL EMITTANCE REQUIREMENTS OF <br />E.E.S. SEC 118. <br />60 <br />" <br /> <br />A <br />. <br />F <br />. <br />F <br />. <br />MAXIMUM <br />OCCUPANCY 51 <br />5/8" <br />10" <br />5 <br />5 <br />/ <br />8 <br />" <br />1/2" <br />3/8" - <br />1/4" RADIUS, TYP.48 <br />" <br /> <br />M <br />I <br />N <br /> <br />A <br />. <br />F <br />. <br />F <br />. <br />TYP. <br /> <br /> <br />1" MIN. <br />NOTE: LETTERS & NUMBERS TO CONTRAST <br />WITH BACKGROUND <br />3/16" THK. ACRYLIC <br />FLUSH MOUNTED <br />TO WALL <br />LOCATION: AT ROOMS OR SPACES WITH AN <br />ASSEMBLY OCCUPANT LOAD OF 50 OR <br />GREATER. SEE FIRE LIFE SAFETY DRAWINGS <br />(R1.LS SERIES SHEETS) FOR OCCUPANT LOAD <br />NUMBER DESIGNATION. <br />3 <br />I <br />N <br />. <br /> <br />M <br />I <br />N <br />FIGURE 3007.7.5 <br />FIRE SERVICE ACCESS ELEVATOR SYMBOL <br />A pictorial symbol of a standardized design designating which elevators are fire service access elevators shall be installed <br />on each side of the hoistway door frame on the portion of the frame at right angles to the fire service access elevator <br />lobby. The fire service access elevator symbol shall be designed as shown in Figure 3007.7.5 and shall comply with the <br />following: <br />1. The fire service access elevator symbol shall be not less than 3 inches (76 mm) in height. <br />2. The vertical center line of the fire service access elevator symbol shall be centered on the hoistway door frame. <br />Each symbol shall be not less than 78 inches (1981 mm), and not more than 84 inches (2134 mm) above the <br />finished floor at the threshold. <br />© Gensler <br />Date Description <br />Project Name <br />Project Number <br />Description <br />Scale <br />Seal / Signature <br />2021 <br />Tel 949.863.9434 <br />Fax 949-553-1676 <br />4675 MacArthur Court <br />Suite 100 <br />Newport Beach, CA <br />92600 <br />USA <br />As indicated <br />11/18/2024 3:31:03 PM <br />BIM 360://007.3757.000 - Caribou Industries - 3rd & Broadway/3RD-B_ARCH_WEST_R20.rvt <br />R1.G0.012 <br />GENERAL NOTES <br />07.3757.400 <br />3rd & Broadway Residential <br />Tower Core & Shell <br />301 N. Broadway, Santa Ana, CA <br />1. EXCEPT AS OTHERWISE PROVIDED FOR IN THIS CODE, THE DESIGN, CONSTRUCTION, <br />INSTALLATION, ALTERATION, REPAIR AND MAINTENANCE OF ELEVATORS AND CONVEYING <br />SYSTEMS AND THEIR COMPONENTS SHALL CONFOR TO CALIFORNIA CODE OF REGULATIONS, <br />TITLE 8, DIVISION 1, CHAPTER 4, SUBCHAPTER 6, ELEVATOR SAFETY ORDERS, ASME A90.1, ASME <br />B20.1, AL I AL CTV, AND ASCE 24 FOR CONSTRUCTION IN FLOOD HAZARD AREAS ESTABLISHED IN <br />SECTION 1612.3. <br />2. ELEVATORS SHALL COMPLY WITH CBC SECTION 11B-407 AND WITH ASME A17.1. THEY SHALL <br />BE PASSENGER ELEVATORS AS CLASSIFIED BY ASME A17.1. ELEVATOR OPERATION SHALL BE <br />AUTOMATIC. <br />3. WHEN THE ONLY ELEVATORS PROVIDED FOR USE BY THE PUBLIC AND EMPLOYEES ARE <br />COMBINATION PASSENGER AND FREIGHT ELEVATORS, THEY SHALL COMPLY WITH CBC SECTION <br />11B-407 AND WITH ASME A17.1. <br />4. ELEVATOR LANDING REQUIREMENTS. ELEVATOR LANDINGS SHALL COMPLY WITH CBC <br />SECTION 11B-407.2. <br />a. HEIGHT: CALL BUTTONS AND KEYPADS SHALL BE LOCATED WITHIN ONE OF THE REACH <br />RANGES SPECIFIED IN SECTION 11B-308, MEASURED TO THE CENTERLINE OF THE HIGHEST <br />OPERABLE PART. <br />b. SIZE AND SHAPE. CALL BUTTONS SHALL HAVE SQUARE SHOULDERS, BE ¾ INCH (19.1 MM) <br />MINIMUM IN THE SMALLEST DIMENSION AND SHALL BE RAISED ⅛ INCH (3.2 MM) PLUS OR MINUS <br />1/32 INCH (0.8 MM) ABOVE THE SURROUNDING SURFACE. THE BUTTONS SHALL BE ACTIVATED BY <br />A MECHANICAL MOTION THAT IS DETECTABLE. <br />c. CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR OR GROUND SPACE COMPLYING <br />WITH SECTION 11B-305 SHALL BE PROVIDED AT CALL CONTROLS. <br />d. LOCATION. THE CALL BUTTON THAT DESIGNATES THE UP DIRECTION SHALL BE LOCATED <br />ABOVE THE CALL BUTTON THAT DESIGNATES THE DOWN DIRECTION. DESTINATION-ORIENTED <br />ELEVATORS SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B407.2.1.4. <br />e. SIGNALS. CALL BUTTONS SHALL HAVE VISIBLE SIGNALS THAT WILL ACTIVATE WHEN EACH <br />CALL IS REGISTERED AND WILL EXTINGUISH WHEN EACH CALL IS ANSWERED. CALL BUTTONS <br />SHALL BE INTERNALLY ILLUMINATED WITH A WHITE LIGHT OVER THE ENTIRE SURFACE OF THE <br />BUTTON. DESTINATION-ORIENTED ELEVATORS SHALL NOT BE REQUIRED TO COMPLY WITH <br />SECTION 11B407.2.1.5 PROVIDED THAT VISIBLE AND AUDIBLE SIGNALS COMPLYING WITH SECTION <br />11B407.2.2, INDICATING WHICH ELEVATOR CAR TO ENTER, ARE PROVIDED. <br />f. KEYPADS. WHERE KEYPADS ARE PROVIDED, KEYPADS SHALL BE IN A STANDARD <br />TELEPHONE KEYPAD ARRANGEMENT AND SHALL COMPLY WITH SECTION 11B-407.4.7.2. <br />g. HALL SIGNALS, INCLUDING IN-CAR SIGNALS, SHALL COMPLY WITH SECTION 11B407.2.2. <br />h. VISIBLE AND AUDIBLE SIGNALS. A VISIBLE AND AUDIBLE SIGNAL SHALL BE PROVIDED AT <br />EACH HOISTWAY ENTRANCE TO INDICATE WHICH CAR IS ANSWERING A CALL AND THE CAR’S <br />DIRECTION OF TRAVEL. WHERE IN-CAR SIGNALS ARE PROVIDED, THEY SHALL BE VISIBLE FROM <br />THE FLOOR AREA ADJACENT TO THE HALL CALL BUTTONS. VISIBLE AND AUDIBLE SIGNALS SHALL <br />NOT BE REQUIRED AT EACH DESTINATION-ORIENTED ELEVATOR. <br />i. WHERE A VISIBLE AND AUDIBLE SIGNAL COMPLYING WITH SECTION 11B-407.2.2 IS <br />PROVIDED INDICATING THE ELEVATOR CAR DESIGNATION INFORMATION. <br />j. VISIBLE SIGNALS. VISIBLE SIGNAL FIXTURES SHALL BE CENTERED AT 72 INCHES (1829 MM) <br />MINIMUM ABOVE THE FINISH FLOOR OR GROUND. THE VISIBLE SIGNAL ELEMENTS SHALL BE A <br />MINIMUM 2½ INCHES (64 MM) HIGH BY 2½ INCHES (64 MM) WIDE. SIGNALS SHALL BE VISIBLE FROM <br />THE FLOOR AREA ADJACENT TO THE HALL CALL BUTTON. DESTINATION-ORIENTED ELEVATORS <br />SHALL BE PERMITTED TO HAVE SIGNALS VISIBLE FROM THE FLOOR AREA ADJACENT TO THE <br />HOISTWAY ENTRANCE. <br />k. AUDIBLE SIGNALS. AUDIBLE SIGNALS SHALL SOUND ONCE FOR THE UP DIRECTION AND <br />TWICE FOR THE DOWN DIRECTION, OR SHALL HAVE VERBAL ANNUNCIATORS THAT INDICATE THE <br />DIRECTION OF ELEVATOR CAR TRAVEL. AUDIBLE SIGNALS SHALL HAVE A FREQUENCY OF 1500 HZ <br />MAXIMUM. VERBAL ANNUNCIATORS SHALL HAVE A FREQUENCY OF 300 HZ MINIMUM AND 3000 HZ <br />MAXIMUM. THE AUDIBLE SIGNAL AND VERBAL ANNUNCIATOR SHALL BE 10 DB MINIMUM ABOVE <br />AMBIENT, BUT SHALL NOT EXCEED 80 DB, MEASURED AT THE HALL CALL BUTTON. <br />l. HOISTWAY SIGNS. SIGNS AT ELEVATOR HOISTWAYS SHALL COMPLY WITH SECTION <br />11B-407.2.3. FLOOR DESIGNATION. FLOOR DESIGNATIONS COMPLYING WITH SECTIONS 11B-703.2 <br />AND 11B-703.4.1 SHALL BE PROVIDED ON BOTH JAMBS OF ELEVATOR HOISTWAY ENTRANCES. <br />FLOOR DESIGNATIONS SHALL BE PROVIDED IN BOTH RAISED CHARACTERS AND BRAILLE. RAISED <br />CHARACTERS SHALL BE 2 INCHES (51 MM) HIGH. A RAISED STAR, PLACED TO THE LEFT OF THE <br />FLOOR DESIGNATION, SHALL BE PROVIDED ON BOTH JAMBS AT THE MAIN ENTRY LEVEL. THE <br />OUTSIDE DIAMETER OF THE STAR SHALL BE 2 INCHES (51 MM) AND ALL POINTS SHALL BE OF <br />EQUAL LENGTH. RAISED CHARACTERS, INCLUDING THE STAR, SHALL BE WHITE ON A BLACK <br />BACKGROUND. BRAILLE COMPLYING WITH SECTION 11B-703.3 SHALL BE PLACED BELOW THE <br />CORRESPONDING RAISED CHARACTERS AND THE STAR. THE BRAILLE TRANSLATION FOR THE <br />STAR SHALL BE “MAIN”. APPLIED PLATES ARE ACCEPTABLE IF THEY ARE PERMANENTLY FIXED TO <br />THE JAMB. <br />m. CAR DESIGNATIONS. DESTINATION-ORIENTED ELEVATORS SHALL PROVIDE TACTILE CAR <br />IDENTIFICATION COMPLYING WITH SECTIONS 11B-703.2 AND 11B-703.4.1 ON BOTH JAMBS OF THE <br />HOISTWAY IMMEDIATELY BELOW THE FLOOR DESIGNATION. CAR DESIGNATIONS SHALL BE <br />PROVIDED IN BOTH RAISED CHARACTERS AND BRAILLE. RAISED CHARACTERS SHALL BE 2 <br />INCHES (51 MM) HIGH. RAISED CHARACTERS SHALL BE WHITE ON A BLACK BACKGROUND. <br />BRAILLE COMPLYING WITH SECTION 11B-703.3 SHALL BE PLACED BELOW THE CORRESPONDING <br />RAISED CHARACTERS. APPLIED PLATES ARE ACCEPTABLE IF THEY ARE PERMANENTLY FIXED TO <br />THE JAMB. <br />5. ELEVATOR DOOR REQUIREMENTS. HOISTWAY AND CAR DOORS SHALL COMPLY WITH <br />SECTION 11B-407.3. <br />a. TYPE. ELEVATOR DOORS SHALL BE THE HORIZONTAL SLIDING TYPE. CAR GATES SHALL <br />BE PROHIBITED. <br />b. OPERATION. ELEVATOR HOISTWAY AND CAR DOORS SHALL OPEN AND CLOSE <br />AUTOMATICALLY. EXISTING MANUALLY OPERATED HOISTWAY SWING DOORS SHALL BE <br />PERMITTED PROVIDED THAT THEY COMPLY WITH SECTIONS 11B-404.2.3 AND 11B-404.2.9. CAR <br />DOOR CLOSING SHALL NOT BE INITIATED UNTIL THE HOISTWAY DOOR IS CLOSED. <br />c. REOPENING DEVICE. ELEVATOR DOORS SHALL BE PROVIDED WITH A REOPENING DEVICE <br />COMPLYING WITH SECTION 11B-407.3.3 THAT SHALL STOP AND REOPEN A CAR DOOR AND <br />HOISTWAY DOOR AUTOMATICALLY IF THE DOOR BECOMES OBSTRUCTED BY AN OBJECT OR <br />PERSON. EXISTING ELEVATORS WITH MANUALLY OPERATED DOORS SHALL NOT BE REQUIRED <br />TO COMPLY WITH SECTION 11B-407.3.3. <br />d. HEIGHT. THE DEVICE SHALL BE ACTIVATED BY SENSING AN OBSTRUCTION PASSING <br />THROUGH THE OPENING AT 5 INCHES (127 MM) NOMINAL AND 29 INCHES (737 MM) NOMINAL <br />ABOVE THE FINISH FLOOR. <br />e. CONTACT. THE DEVICE SHALL NOT REQUIRE PHYSICAL CONTACT TO BE ACTIVATED, <br />ALTHOUGH CONTACT IS PERMITTED TO OCCUR BEFORE THE DOOR REVERSES. <br />f. DURATION. DOOR REOPENING DEVICES SHALL REMAIN EFFECTIVE FOR 20 SECONDS <br />MINIMUM. <br />g. DOOR AND SIGNAL TIMING. THE MINIMUM ACCEPTABLE TIME FROM NOTIFICATION THAT A <br />CAR IS ANSWERING A CALL OR NOTIFICATION OF THE CAR ASSIGNED AT THE MEANS FOR THE <br />ENTRY OF DESTINATION INFORMATION UNTIL THE DOORS OF THAT CAR START TO CLOSE SHALL <br />BE CALCULATED FROM THE FOLLOWING EQUATION: <br />T = D/(1.5 FT/S) OR T = D/(455 MM/S) = 5 SECONDS MINIMUM WHERE T EQUALS THE TOTAL TIME IN <br />SECONDS AND D EQUALS THE DISTANCE (IN FEET OR MILLIMETERS) FROM THE POINT IN THE <br />LOBBY OR CORRIDOR 60 INCHES (1524 MM) DIRECTLY IN FRONT OF THE FARTHEST CALL BUTTON <br />CONTROLLING THAT CAR TO THE CENTERLINE OF ITS HOISTWAY DOOR. <br />FOR CARS WITH IN-CAR LANTERNS, T SHALL BE PERMITTED TO BEGIN WHEN THE SIGNAL IS <br />VISIBLE FROM THE POINT 60 INCHES (1524 MM) DIRECTLY IN FRONT OF THE FARTHEST HALL CALL <br />BUTTON AND THE AUDIBLE SIGNAL IS SOUNDED. <br />DESTINATION-ORIENTED ELEVATORS SHALL NOT BE REQUIRED TO COMPLY WITH SECTION <br />11B-407.3.4. <br />h. DOOR DELAY. ELEVATOR DOORS SHALL REMAIN FULLY OPEN IN RESPONSE TO A CAR <br />CALL FOR 5 SECONDS MINIMUM. <br />i. WIDTH. THE WIDTH OF ELEVATOR DOORS SHALL COMPLY WITH TABLE 11B-407.4.1. IN <br />EXISTING ELEVATORS, A POWER-OPERATED CAR DOOR COMPLYING WITH SECTION 11B-404.2.3 <br />SHALL BE PERMITTED. <br />6. ELEVATOR CAR REQUIREMENTS. ELEVATOR CARS SHALL COMPLY WITH SECTION 11B-407.4. <br />a. CAR DIMENSIONS. INSIDE DIMENSIONS OF ELEVATOR CARS AND CLEAR WIDTH OF <br />ELEVATOR DOORS SHALL COMPLY WITH TABLE 11B-407.4.1. IN EXISTING BUILDINGS, WHERE <br />EXISTING SHAFT CONFIGURATION OR TECHNICAL INFEASIBILITY PROHIBITS STRICT COMPLIANCE <br />WITH SECTION 11B-407.4.1, EXISTING ELEVATOR CAR CONFIGURATIONS THAT PROVIDE A CLEAR <br />FLOOR AREA OF 18 SQUARE FEET (1.67 M2) MINIMUM AND ALSO PROVIDE AN INSIDE CLEAR <br />DEPTH 54 INCHES (1372 MM) MINIMUM AND A CLEAR WIDTH 48 INCHES (1219 MM) MINIMUM SHALL <br />BE PERMITTED. <br />(INSERT TABLE 11B-407.4.1 ELEVATOR CAR DIMENSIONS) <br />b. FLOOR SURFACES. FLOOR SURFACES IN ELEVATOR CARS SHALL COMPLY WITH <br />SECTIONS 11B-302 AND 11B-303. <br />c. PLATFORM TO HOISTWAY CLEARANCE. THE CLEARANCE BETWEEN THE CAR PLATFORM <br />SILL AND THE EDGE OF ANY HOISTWAY LANDING SHALL BE 1¼ INCH (32 MM) MAXIMUM. <br />d. LEVELING. EACH CAR SHALL BE EQUIPPED WITH A SELF-LEVELING FEATURE THAT WILL <br />AUTOMATICALLY BRING AND MAINTAIN THE CAR AT FLOOR LANDINGS WITHIN A TOLERANCE OF ½ <br />INCH (12.7 MM) UNDER RATED LOADING TO ZERO LOADING CONDITIONS. <br />e. ILLUMINATION. THE LEVEL OF ILLUMINATION AT THE CAR CONTROLS, PLATFORM, CAR <br />THRESHOLD AND CAR LANDING SILL SHALL BE 5 FOOT CANDLES (54 LUX) MINIMUM. <br />STAIR/EXIT/EGRESS SIGNAGEELEVATOR NOTES / DETAILS GENERAL NOTESCALGREEN NOTES <br />ENERGY EFFICIENCY STDS <br />DEFIBRILLATORS (AED'S)STORMWATER REQT'S <br />f. ELEVATOR CAR CONTROLS. WHERE PROVIDED, ELEVATOR CAR CONTROLS <br />SHALL COMPLY WITH SECTIONS 11B-407.4.6 AND 11B-309.4. IN EXISTING ELEVATORS, <br />WHERE A NEW CAR OPERATING PANEL COMPLYING WITH SECTION 11B407.4.6IS <br />PROVIDED, EXISTING CAR OPERATING PANELS MAY REMAIN OPERATIONAL AND <br />SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-407.4.6. <br />g. LOCATION. CONTROLS SHALL BE LOCATED WITHIN ONE OF THE REACH <br />RANGES SPECIFIED IN SECTION 11B-308. <br />h. WHERE THE ELEVATOR PANEL SERVES MORE THAN 16 OPENINGS AND A <br />PARALLEL APPROACH IS PROVIDED, BUTTONS WITH FLOOR DESIGNATIONS SHALL BE <br />PERMITTED TO BE 54 INCHES (1372 MM) MAXIMUM ABOVE THE FINISH FLOOR. <br />i. IN EXISTING ELEVATORS, CAR CONTROL BUTTONS WITH FLOOR <br />DESIGNATIONS SHALL BE PERMITTED TO BE LOCATED 54 INCHES (1372 MM) MAXIMUM <br />ABOVE THE FINISH FLOOR WHERE A PARALLEL APPROACH IS PROVIDED. <br />j. BUTTONS. CAR CONTROL BUTTONS WITH FLOOR DESIGNATIONS SHALL <br />COMPLY WITH SECTION 11B407.4.6.2. <br />i. SIZE AND SHAPE. BUTTONS SHALL HAVE SQUARE SHOULDERS, BE 3/4 INCH <br />(19.1 MM) MINIMUM IN THEIR SMALLEST DIMENSION AND BE RAISED 1/8 INCH (3.2 MM) <br />PLUS OR MINUS 1/32 INCH (0.8 MM) ABOVE THE SURROUNDING SURFACE. <br />ii. ARRANGEMENT. BUTTONS SHALL BE ARRANGED WITH NUMBERS IN <br />ASCENDING ORDER. WHEN TWO OR MORE COLUMNS OF BUTTONS ARE PROVIDED <br />THEY SHALL READ FROM LEFT TO RIGHT. <br />iii. ILLUMINATION. CAR CONTROL BUTTONS SHALL BE ILLUMINATED. <br />iv. OPERATION. CAR CONTROL BUTTONS SHALL BE ACTIVATED BY A <br />MECHANICAL MOTION THAT IS DETECTABLE. <br />k. KEYPADS. CAR CONTROL KEYPADS SHALL BE IN A STANDARD TELEPHONE <br />KEYPAD ARRANGEMENT AND SHALL COMPLY WITH SECTION 11B-407.4.7.2. <br />l. EMERGENCY CONTROLS. EMERGENCY CONTROLS SHALL COMPLY WITH <br />SECTION 11B407.4.6.4. <br />i. HEIGHT. EMERGENCY CONTROL BUTTONS SHALL HAVE THEIR CENTERLINES <br />35 INCHES (889 MM) MINIMUM ABOVE THE FINISH FLOOR. <br />ii. LOCATION. EMERGENCY CONTROLS, INCLUDING THE EMERGENCY ALARM, <br />SHALL BE GROUPED AT THE BOTTOM OF THE PANEL. <br />7. DESIGNATIONS AND INDICATORS OF CAR CONTROLS. DESIGNATIONS AND <br />INDICATORS OF CAR CONTROLS SHALL COMPLY WITH SECTION 11B-407.4.7. IN <br />EXISTING ELEVATORS, WHERE A NEW CAR OPERATING PANEL COMPLYING WITH <br />SECTION 11B407.4.7 IS PROVIDED, EXISTING CAR OPERATING PANELS MAY REMAIN <br />OPERATIONAL AND SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-407.4.7. <br />a. BUTTONS. CAR CONTROL BUTTONS SHALL COMPLY WITH SECTION <br />11B-407.4.7.1. <br />i. TYPE. CONTROL BUTTONS SHALL BE IDENTIFIED BY RAISED CHARACTERS OR <br />SYMBOLS, WHITE ON A BLACK BACKGROUND, COMPLYING WITH SECTION 11B-703.2 <br />AND BRAILLE COMPLYING WITH SECTION 11B-703.3. <br />ii. LOCATION. RAISED CHARACTERS OR SYMBOLS AND BRAILLE DESIGNATIONS <br />SHALL BE PLACED IMMEDIATELY TO THE LEFT OF THE CONTROL BUTTON TO WHICH <br />THE DESIGNATIONS APPLY. <br />iii. SYMBOLS. THE CONTROL BUTTON FOR THE EMERGENCY STOP, ALARM, <br />DOOR OPEN, DOOR CLOSE, MAIN ENTRY FLOOR, AND PHONE, SHALL BE IDENTIFIED <br />WITH RAISED SYMBOLS AND BRAILLE AS SHOWN IN TABLE 11B-407.4.7.1.3. <br />iv. VISIBLE INDICATORS. BUTTONS WITH FLOOR DESIGNATIONS SHALL BE <br />PROVIDED WITH VISIBLE INDICATORS TO SHOW THAT A CALL HAS BEEN REGISTERED. <br />THE VISIBLE INDICATION SHALL EXTINGUISH WHEN THE CAR ARRIVES AT THE <br />DESIGNATED FLOOR. <br />v. BUTTON SPACING. A MINIMUM CLEAR SPACE OF 3/8 INCH (9.5 MM) OR OTHER <br />SUITABLE MEANS OF SEPARATION SHALL BE PROVIDED BETWEEN ROWS OF <br />CONTROL BUTTONS. <br />b. KEYPADS. KEYPADS SHALL BE IDENTIFIED BY CHARACTERS COMPLYING WITH <br />SECTION 11B703.5AND SHALL BE CENTERED ON THE CORRESPONDING KEYPAD <br />BUTTON. THE NUMBER FIVE KEY SHALL HAVE A SINGLE RAISED DOT. THE DOT SHALL <br />BE 0.118 INCH (3 MM) TO 0.120 INCH (3.05 MM) BASE DIAMETER AND IN OTHER <br />ASPECTS COMPLY WITH TABLE 11B-703.3.1. <br />c. CAR POSITION INDICATORS. AUDIBLE AND VISIBLE CAR POSITION INDICATORS <br />SHALL BE PROVIDED IN ELEVATOR CARS. <br />i. VISIBLE INDICATORS. VISIBLE INDICATORS SHALL COMPLY WITH SECTION <br />11B-407.4.8.1. <br />ii. SIZE. CHARACTERS SHALL BE ½ INCH (12.7 MM) HIGH MINIMUM. <br />iii. LOCATION. INDICATORS SHALL BE LOCATED ABOVE THE CAR CONTROL <br />PANEL OR ABOVE THE DOOR. <br />iv. FLOOR ARRIVAL. AS THE CAR PASSES A FLOOR AND WHEN A CAR STOPS AT A <br />FLOOR SERVED BY THE ELEVATOR, THE CORRESPONDING CHARACTER SHALL <br />ILLUMINATE. DESTINATION-ORIENTED ELEVATORS SHALL NOT BE REQUIRED TO <br />COMPLY WITH SECTION 11B-407.4.8.1.3 PROVIDED THAT THE VISIBLE INDICATORS <br />EXTINGUISH WHEN THE CALL HAS BEEN ANSWERED. <br />v. DESTINATION INDICATOR. IN DESTINATION-ORIENTED ELEVATORS, A DISPLAY <br />SHALL BE PROVIDED IN THE CAR WITH VISIBLE INDICATORS TO SHOW CAR <br />DESTINATIONS. <br />d. AUDIBLE INDICATORS. AUDIBLE INDICATORS SHALL COMPLY WITH SECTION <br />11B-407.4.8.2. <br />i. SIGNAL TYPE. THE SIGNAL SHALL BE AN AUTOMATIC VERBAL ANNUNCIATOR <br />WHICH ANNOUNCES THE FLOOR AT WHICH THE CAR IS ABOUT TO STOP. FOR <br />ELEVATORS OTHER THAN DESTINATION-ORIENTED ELEVATORS THAT HAVE A RATED <br />SPEED OF 200 FEET PER MINUTE (1 M/S) OR LESS, A NON-VERBAL AUDIBLE SIGNAL <br />WITH A FREQUENCY OF 1500 HZ MAXIMUM WHICH SOUNDS AS THE CAR PASSES OR <br />IS ABOUT TO STOP AT A FLOOR SERVED BY THE ELEVATOR SHALL BE PERMITTED. <br />ii. SIGNAL LEVEL. THE VERBAL ANNUNCIATOR SHALL BE 10 DB MINIMUM ABOVE <br />AMBIENT, BUT SHALL NOT EXCEED 80 DB, MEASURED AT THE ANNUNCIATOR. <br />iii. FREQUENCY. THE VERBAL ANNUNCIATOR SHALL HAVE A FREQUENCY OF 300 <br />HZ MINIMUM TO 3000 HZ MAXIMUM. <br />8. EMERGENCY COMMUNICATION. EMERGENCY TWO-WAY COMMUNICATION <br />SYSTEMS SHALL COMPLY WITH SECTION 11B-308. RAISED SYMBOLS OR <br />CHARACTERS, WHITE ON A BLACK BACKGROUND, AND BRAILLE SHALL BE PROVIDED <br />ADJACENT TO THE DEVICE AND SHALL COMPLY WITH SECTIONS 11B-703.2 AND <br />11B-703.3. EMERGENCY TWO-WAY COMMUNICATION SYSTEMS BETWEEN THE <br />ELEVATOR AND A POINT OUTSIDE THE HOISTWAY SHALL COMPLY WITH ASME A17.1. <br />9. SUPPORT RAIL. SUPPORT RAILS SHALL BE PROVIDED ON AT LEAST ONE WALL OF <br />THE CAR. <br />a. LOCATION. CLEARANCE BETWEEN SUPPORT RAILS AND ADJACENT <br />SURFACES SHALL BE 1½ INCHES (38 MM) MINIMUM. TOP OF SUPPORT RAILS SHALL BE <br />31 INCHES (787 MM) MINIMUM TO 33 INCHES (838 MM) MAXIMUM ABOVE THE FLOOR OF <br />THE CAR. THE ENDS OF THE SUPPORT RAIL SHALL BE 6 INCHES (152 MM) MAXIMUM <br />FROM ADJACENT WALLS. <br />b. SURFACES. SUPPORT RAILS SHALL BE SMOOTH AND ANY SURFACE <br />ADJACENT TO THEM SHALL BE FREE OF SHARP OR ABRASIVE ELEMENTS. <br />c. STRUCTURAL STRENGTH. ALLOWABLE STRESSES SHALL NOT BE EXCEEDED <br />FOR MATERIALS USED WHEN A VERTICAL OR HORIZONTAL FORCE OF 250 POUNDS <br />(1112 N) IS APPLIED AT ANY POINT ON THE SUPPORT RAIL, FASTENER, MOUNTING <br />DEVICE, OR SUPPORTING STRUCTURE. <br />10. EMERGENCY SIGNS: AN APPROVED PICTORIAL SIGN OF A STANDARDIZED DESIGN <br />SHALL BE POSTED ADJACENT TO EACH ELEVATOR CALL STATION ON ALL FLOORS <br />INSTRUCTING OCCUPANTS TO USE THE EXIT STAIRWAYS AND NOT TO USE THE <br />ELEVATORS IN CASE OF FIRE. THE SIGN SHALL READ: “IN CASE OF FIRE, ELEVATORS <br />ARE OUT OF SERVICE, USE EXIT STAIRS”. THE EMERGENCY SIGN SHALL NOT BE <br />REQUIRED FOR ELEVATORS THAT ARE PART OF AN ACCESSIBLE MEANS OF EGRESS <br />COMPLYING WITH CBC SECTION 1007.4. THE EMERGENCY SIGN SHALL NOT BE <br />REQUIRED FOR ELEVATORS THAT ARE USED FOR OCCUPANT SELF-EVACUATION IN <br />ACCORDANCE WITH CBC SECTION 3006. <br />11. FIRE FIGHTER’S EMERGENCY OPERATION. ELEVATORS SHALL BE PROVIDED <br />WITH PHASE I EMERGENCY RECALL OPERATION AND PHASE II EMERCENCY IN-CAR <br />OPERATION IN ACCORDANCE WITH CALIFORNIA COED OF REGULATIONS, TITLE 8, <br />DIVISION 1, CHAPTER 4, SUBCHAPTER 6, ELEVATOR SAFETY ORDERS. <br />a. FLOOR NUMBERS. ELEVATOR HOISTWAYS SHALL HAVE A FLOOR NUMBER <br />NOT LESS THAN 4 INCHES IN EHIGHT, PLACED ON THE WALLS AND/OR DOORS OF THE <br />HOISTWAY AT INTERVALS SUCH THAT A PERSON IN A STALLED ELEVATOR, UPON <br />OPENING THE CAR DOOR, CAN DETERMINE THE FLOOR POSITION. <br />b. FIRE SIGNS. ALL AUTOMATIC ELEVATORS SHALL HAVE NOT LESS THAN ONE <br />SIGN AT EACH LANDING PRINTED ON A CONTRASTING BACKGROUND IN LETTERS NOT <br />LESS THAN ½ INCH HIGH TO READ: “IN CASE OF FIRE USE STAIRWAY FOR EXIT. DO <br />NOT USE ELEVATOR”. <br />c. CALL AND CAR OPERATION BUTTONS. AUTOMATIC PASSENGER ELEVATORS <br />SHALL HAVE CALL AND OPERATION BUTTONS WITHIN 60 INCHES OF THE FLOOR. <br />EMERGENCY TELEPHONES SHALL ALSO BE WITHIN 60 INCHES OF THE FLOOR. <br />12. STANDARDIZED FIRE SERVICE ELEVATOR KEYS. ALL ELEVATORS SHALL BE <br />EQUIPPED TO OPERATE WITH A STANDARDIZED FIRE SERVICE KEY IN ACCORDANCE <br />WITH THE CALIFORNIA FIRE CODE. <br />1. PERIMETER PROTECTION BMPS MUST BE INSTALLED AND MAINTAINED TO COMPLY WITH <br />CONSTRUCTION STORM WATER BMP PERFORMANCE STANDARDS. <br />2. SEDIMENT CONTROL BMPS MUST BE INSTALLED AND MAINTAINED TO COMPLY WITH <br />CONSTRUCTION STORM WATER BMP PERFORMANCE STANDARDS. <br />3. BMPS TO CONTROL SEDIMENT TRACKING MUST BE INSTALLED AND MAINTAINED AT <br />ENTRANCES/EXITS TO COMPLY WITH CONSTRUCTION STORM WATER BMP PERFORMANCE <br />STANDARDS. <br />4. MATERIALS NEEDED TO INSTALL STANDBY BMPS NECESSARY TO COMPLETELY PROTECT THE <br />EXPOSED PORTIONS OF THE SITE FROM EROSION, AND TO PREVENT SEDIMENT DISCHARGES, MUST <br />BE STORED ON SITE. AREAS ALREADY PROTECTED FROM EROSION THROUGH IMPLEMENTATION <br />OF PHYSICAL STABILIZATION OR ESTABLISHED VEGETATION STABILIZATION BMPS (AS DESCRIBED <br />BELOW) ARE NOT CONSIDERED TO BE “EXPOSED”FOR PURPOSES OF THIS REQUIREMENT. <br />5. DEPLOYMENT OF PHYSICAL OR VEGETATION EROSION CONTROL BMPS MUST COMMENCE AS SOON <br />AS GRADING AND/OR EXCAVATION IS COMPLETED FOR ANY PORTION OF THE SITE. THE PROJECT <br />PROPONENT MAY NOT CONTINUE TO RELY ON THE ABILITY TO DEPLOY STANDBY BMP MATERIALS <br />TO PREVENT EROSION OF GRADED AREAS THAT HAVE BEEN COMPLETED. <br />6. PROTECT AND STABILIZE ALL SLOPES DURING RAIN EVENTS. <br />7. A WASHOUT AREA SHALL BE DESIGNATED AND MAINTAINED FOR MATERIALS SUCH AS CONCRETE, <br />STUCCO, PAINT, CAULKING, SEALANTS, DRYWALL PLASTER, ETC. <br />8. PROPERLY PROTECTED DESIGNATED STORAGE AREAS ARE REQUIRED FOR MATERIALS AND <br />WASTES. <br />9. TRASH AND DEBRIS SHALL BE REMOVED AND PROPERLY STORED OR DISPOSED OF DAILY. <br />10. STORAGE, SERVICE, CLEANING AND MAINTENANCE AREAS FOR VEHICLES AND EQUIPMENT SHALL <br />BE IDENTIFIED AND PROTECTED ACCORDINGLY. <br />11. MATERIALS FOR SPILL CONTROL/CONTAINMENT MUST BE STOCKPILED ONSITE. <br />12. NON-STORM WATER DISCHARGES MUST BE ELIMINATED OR CONTROLLED TO THE MAXIMUM <br />EXTENT PRACTICABLE. <br />MAX OCCUPANT LOAD SIGNAGE <br />EMERGENCY COMMUNICATIONS <br />EMERGENCY ELEVATOR COMMUNICATION SYSTEMS FOR THE DEAF, HARD OF HEARING AND SPEECH <br />IMPAIRED. CBC 3001.2 <br />AN EMERGENCY TWO-WAY COMMUNICATION SYSTEM SHALL BE PROVIDED THAT: <br />1. IS A VISUAL AND TEXT-BASED AND A VIDEO-BASED 24/7 LIVE INTERACTIVE SYSTEM. <br />2. IS FULLY ACCESSIBLE BY THE DEAF, HARD OF HEARING AND SPEECH IMPAIRED, AND SHALL <br />INCLUDE VOICE-ONLY OPTIONS FOR HEARING INDIVIDUALS. <br />3. HAS THE ABILITY TO COMMUNICATE WITH EMERGENCY PERSONNEL UTILIZING EXISTING VIDEO <br />CONFERENCING TECHNOLOGY, CHAT/TEXT SOFTWARE OR OTHER APPROVED TECHNOLOGY. <br />STAIRWAY COMMUNICATION SYSTEM. CBC 403.5.3.1 <br />1. A TELEPHONE OR OTHER TWO-WAY COMMUNICATIONS SYSTEM CONNECTED TO AN APPROVED <br />CONSTANTLY ATTENDED STATION SHALL BE PROVIDED AT NOT LESS THAN EVERY FIFTH FLOOR IN <br />EACH STAIRWAY WHERE THE DOORS TO THE STAIRWAY ARE LOCKED. <br />LUMINOUS EGRESS PATH MARKINGS. Approved luminous egress path markings delineating the exit path shall be <br />provided with exception of the level of exit discharge in lobbies that serve as part of the exit path in accordance with <br />Section 1028.1, Exception 1. <br />MARKINGS WITHIN EXIT COMPONENTS. Egress path markings shall be provided in interior exit stairways, interior <br />exit ramps and exit passageways, in accordance with Sections 1025.2.1 through 1025.2.6. <br />UNIFORMITY. Placement and dimensions of markings shall be consistent and uniform throughout the same <br />enclosure. <br />SELF-LUMINOUS AND PHOTOLUMINESCENT. Luminous egress path markings shall be permitted to be made of <br />any material, including paint, provided that an electrical charge is not required to maintain the required luminance. <br />Such materials shall include, but not be limited to, self-luminous materials and photoluminescent materials. Materials <br />shall comply with either of the standards as indicated in Section 1025.4. <br />ILLUMINATION. Where photoluminescent exit path markings are installed, they shall be provided with not less than 1 <br />footcandle (11 lux) of illumination for not less than 60 minutes prior to periods when the building is occupied and <br />continuously during occupancy. <br />FIRE SERVICE ACCESS ELEV. SYMBOL <br />09/21/2021 Issue for Plan Check <br />A 12/10/2021 Reissue for Plan Check <br />D 05/10/2022 Reissue for Plan Check <br />F 07/11/2022 Reissue for Plan Check <br />G 08/30/2022 Reissue for Plan Check <br />H 06/17/2024 Revision to Permit <br />J 11/22/2024 Reissue for Plan Check <br />J <br />1/7/25