My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
FLOOD ZONE - 4413 W Sunswept Ave & Unit #2 - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Sunswept Ave
>
4413 W Sunswept Ave Unit# 2
>
FLOOD ZONE - 4413 W Sunswept Ave & Unit #2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 10:50:38 AM
Creation date
2/24/2026 10:50:24 AM
Metadata
Fields
Template:
Plan
Permit Number
101122116
Full Address
4413 W Sunswept Ave Unit# 2
Street Number
4413
Street Direction
W
Street Name
Sunswept
Street Suffix
Ave
Unit Number
2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) <br />Member Reaction (lbs)182 @ 2 1/2"2231 (3.50")Passed (8%)--1.0 D + 1.0 Lr (All Spans) <br />Shear (lbs)166 @ 9"1238 Passed (13%)1.25 1.0 D + 1.0 Lr (All Spans) <br />Moment (Ft-lbs)741 @ 8' 6 1/2"1060 Passed (70%)1.25 1.0 D + 1.0 Lr (All Spans) <br />Live Load Defl. (in)0.696 @ 8' 6 1/2"0.833 Passed (L/287)--1.0 D + 1.0 Lr (All Spans) <br />Total Load Defl. (in)1.113 @ 8' 6 1/2"1.111 Passed (L/180)--1.0 D + 1.0 Lr (All Spans) <br />Member Length : 17' 1" <br />System : Ceiling <br />Member Type : Attic Joist <br />Building Use : Residential <br />Building Code : IBC 2021 <br />Design Methodology : ASD <br />Member Pitch : 0/12 <br />•Deflection criteria: LL (L/240) and TL (L/180). <br />•Allowed moment does not reflect the adjustment for the beam stability factor. <br />•A 15% increase in the moment capacity has been added to account for repetitive member usage. <br />•Applicable calculations are based on NDS. <br />• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br />Bearing Length Loads to Supports (lbs) <br />Supports Total Available Required Dead Roof Live Factored Accessories <br />1 - Stud wall - SPF 3.50"3.50"1.50"68 114 182 Blocking <br />2 - Stud wall - SPF 3.50"3.50"1.50"68 114 182 Blocking <br />•Maximum allowable bracing intervals based on applied load. <br />Lateral Bracing Bracing Intervals Comments <br />Top Edge (Lu)9' 10" o/c <br />Bottom Edge (Lu)17' 1" o/c <br />• Only vertical loads are available for Attic Joist member types. No tension loading will be considered in the design for these members. <br />Dead Roof Live <br />Vertical Load Location (Side)Spacing (0.90)(1.25)Comments <br />1 - Uniform (PSF)0 to 17' 1"16"6.0 10.0 Default Load <br />Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties <br />related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is <br />responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at <br />Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br />and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ <br />document-library. <br />The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator <br />Weyerhaeuser Notes <br />Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). <br />MEMBER REPORT PASSED <br />ADU, 2X6 C.J. @ 16" O.C. (MAX L=16'-6") <br />1 piece(s) 2 x 6 DF No.2 @ 16" OC <br />ForteWEB Software Operator Job Notes 11/5/2024 11:14:20 AM UTC <br />Alex Chang <br />N/A <br />(657) 331-1935 <br />alex.engineer2223@gmail.com <br />ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 <br />File Name: 24117- 4413 W. Sunsept Ave, Unit #2 Santa Ana, <br />CA 92703 <br />Page 3 / 5
The URL can be used to link to this page
Your browser does not support the video tag.