Laserfiche WebLink
Job Name: 8824VL <br />Date: 4/23/24 <br />SEISMIC LOAD AT 1st FLOOR <br />LONGITUDINAL DIRECTION : <br />Wall Trib. Area Fabv. Ftrib. Ftotal L Q Mark Allow <br />(sqr ft) (lb) (lb) (lb) (ft) (plf) (plf) <br />1 120 0 445 445 4 111 10 260 <br />2 555.5 0 2062 2062 5 412 12 490 <br />TRANSVERSE DIRECTION : <br />Wall Trib. Area Fabv. Ftrib. Ftotal L Q Mark Allow <br />(sqr ft) (lb) (lb) (lb) (ft) (plf) (plf) <br />3 561 0 2082 2082 5 416 12 490 <br />` <br />TMC ENGINEER INC. <br />9542 Pacific Ave, Anaheim, CA 92804 <br />Phone: (714)-829-5053; Email: Tienchu.pe@gmail.com.