Laserfiche WebLink
St. Barbara Catholic School <br />Project No.: D-6289-01 <br />CITY OF SANTA ANA <br />Planning and Building Agency <br />may, lS. <br />Approved <br />FOR PERMIT ISSUANCE <br />Mat footing should be provided with reinforcement of #4 bars 12 inches center to center <br />each way cross pattern. Total settlement of the new structure will be less iiat Me 2:inches <br />Date: <br />and differential settlement will be less than 1/4 of an inch over a horizontal distance of <br />about 30 feet. <br />Other aspects of the design, including rigid mat thickness and reinforcement should be <br />determined by the project structural engineer. <br />New Solid Wall Signage <br />New solid wall signage structure may be supported by conventional continuous footing <br />12" wide and 18 inches deep continuous footings or 3'x3'x24 inches deep spread footing <br />bearing on competent compacted subgrade soil under the footing and may be designed <br />for an allowable bearing value of 2,000 pounds per square foot. <br />The basic allowable bearing values may be increased by 200 psf for each additional foot <br />of depth and 100 psf for each additional increase in width to a maximum of 2,500 pounds <br />per square foot. <br />Recommended bearing values are for dead plus live loads and may be increased one-third <br />for combined dead, live, and transient forces such as wind load and seismic forces. <br />Footings should be embedded 24 inches or more below the finish grade and should have <br />minimum reinforcement of 2#4 bars at top and 2#4 bars at the bottom. It is recommended <br />however, that all foundations be reinforced as per structural design. Isolated column <br />footings should be connected to other foundation elements with reinforced grade beams. <br />It is estimated that provided all footings are bearing on properly compacted subgrade soil <br />total settlement will be less than 1/2" and differential settlement will be less than 1/4" <br />over a horizontal distance of 30 feet. <br />IN <br />