Laserfiche WebLink
A I B C I D I E <br />F <br />Planning and Buil <br />inQLAgenc <br />N <br />O <br />NI <br />ry <br />Q <br />(N� <br />_`e <br />N <br />m <br />U <br />a� <br />L <br />0 <br />4-- <br />0 <br />a) <br />cn <br />a) <br />U <br />O <br />0 <br />0 <br />5 <br />N <br />m LOCAL FIRE ACCESS PLAN <br />SCALE: 1" = 30'-0" <br />0 15 30 60 <br />SCALE: 1" = 30' <br />MCFADDEN AVENUE <br />W <br />Z <br />a <br />J <br />cn <br />cn <br />W <br />/V <br />V <br />a <br />W <br />W <br />`000 <br />GENERAL FIRE ACCESS NOTES <br />NOTE: <br />FIRE DEPARTMENT ACECSS, EGRESS AND GATE ENTRANCES HAVE BEEN REVIEWED FOR COMPLIANCE WITH SECTION 3.05 AND 3.16 TITLE 19 <br />FIRE FLOW AND FIRE HYDRANTS HAVE BEEN REVIEWED FOR COMPLIANCE WITH STATE APPENDICES 111-AA, 111-BB, PART 9, TITLE 24. <br />FIRE FLOW: <br />TYPE OF CONSTRUCTION PER THE BUILDING CODE: TYPE VB WITH SPRINKLERS <br />FIRE -FLOW CALCULATION AREA: AREA 12,875 SF <br />FIRE FLOW BASED ON THE FIRE -FLOW CALCULATION AREA: 3,000 GPM <br />REDUCTION FOR FIRE SPRINKLERS (MAXIMUM 50%): 1,000 GPM <br />TOTAL FIRE FLOW REQUIRED: 2,000 GPM <br />MIN. FIRE FLOW REQUIREMENT: 1,250 GPM <br />FIRE ACCESS NOTES: <br />1. FIRE DEPARTMENT VEHICULAR ACCESS ROADS MUST BE INSTALLED AND MAINTAINED IN A SERVICEABLE CONSTRUCTION. FIRE CODE 501.4. <br />2. APPROVED VUILDING ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION SHALL BE PROVIDED AND MAINTAINED <br />SO AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET FRONTING THE PROPERTY. THE NUMBERS SHALL CONTRAST WITH THEIR <br />BACKGROUND, BE ARABIC NUMERALS OR ALPHABET LETTERS, AND BE A MINIMUM OF 4 INCHES HIGH WITH A MINIMUM STROKE WIDTH OF 0.5 <br />INCH. FIRE CODE 505.1. <br />3. A KEY BOX SHALL BE PROVIDED AND MAINTAINED PER SITE PLAN LOCATIONS IN ACCORDANCE WITH FIRE CODE 506, AND AS SET FORTH IN FIRE <br />DEPARTMENT REGULATION 5. <br />4. THE REQUIRED FIRE FLOW FOR PUBLIC FIRE HYDRANTS AT THIS LOCATION IS 3,500 GPM, AT 20 PSI RESIDUAL PRESSURE FOR A DURATION OF 3 <br />HOURS OVER AND ABOVE MAXIMUM DAILY DOMESTIC DEMAND. FIRE CODE 508.3 AND FIRE DEPARTMENT REGULATION-8. <br />5. THE REQUIRED FIRE FLOW FOR ON -SITE FIRE HYDRANTS AT THIS LOCATION IS 1,250 GPM AT 20 PSI RESIDUAL PRESSURE. WHEN TWO OR MORE <br />ON SITE HYDRANTS REQUIRED, THE FIRE FLOW SHALL BE 2,500 GPM, WITH EACH ON -SITE FIRE HYDRANT BEING CAPABLE OF FLOWING 1,250 GPM <br />AT 20 PSI RESIDUAL PRESSURE FIRE CODE 508.1 AND FIRE DEPARTMENT REGULATION-8. <br />6. ALL FIRE HYDRANTS SHALL MEASURE 6" X 4" X 2-112", BRASS OR BRONZE, CONFORMING TO AMERICAN WATER WORKS ASSOCIATTION <br />STANDARD C503, OR APPROVED EQUAL; AND SHALL BE INSTALLED IN ACCORDANCE WITH THE COUNTY OF LOS ANGELES FIRE DEPARTMENT <br />REGULATION-8. <br />7. PLANS SHOWING UNDERGROUND PIPING OF ON -SIDE FIRE HYDRANTS SHALL BE SUBMITTED TO SPRINKLER PLAN CHECK UNIT FOR REVIEW <br />AND APPROVAL PRIOR TO INSTALLATION. FIRE CODE 901.2. <br />8. THE INSPECTION, HYDROSTATIC TEST AND FLUSHING OF THE UNDEDRGROUND FIRE PROTECTION PIPING SHALL BE WITNESSED BY AN <br />AUTHORIZED FIRE DEPARTMENT REPRESENTATIVE AND NO UNDERGROUND PIPING OR THRUST BLOCKS SHAKLL BE COVERED WITH EARTH OR <br />HIDDEN FROM VIEW UNTIL THE FIRE DEPARTMENT REPRESENTATIVE HAS BEEN NOTIFIED AND GIVEN NOT LESS THAN 48 HOURS IN WHICH TO <br />INSPECT S\UCH INSTALLATIONS. FIRE CODE 901.5. <br />9. PROVIDE AN APPROVED AUTOMATIC FIRE SPRINKLER SYSTEM AS SET FORTH BY BUILDING CODE 903 AND FIRE CODE 903. PLANS SHALL BE <br />SUBMITTED TO THE SPRINKLER PLAN CHECK UNIT FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. <br />REASON: CFC-CHAPTER 9, SECTION 903.2.3. <br />TYPE OF FIRE SPRINKLER SYSTEM: 903.3.1.1. <br />10. EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR <br />EFFORT. BUILDING CODE 1008.1.9. <br />11. PORTABLE FIRE EXTINGUISHERS SHALL BE INSTALLED IN LOCATIONS AS REQUIRED BY FIRE CODE 906. <br />12. DUMPSTERS AND CONTAINERS WITH AN INDIVIDUAL CAPACITY OF 1.5 CUBIC YARDS OR MORE SHALL NOT BE STORED IN BUILDINGS OR <br />PLACED WITHIN 5 FEET OF COMBUSTIBLE WALLS, OPENINGS OR COMBUSTIBLE ROOF EAVES, UNLESS AREAS CONTAINING DUMPSTERS OR <br />CONTAINERS ARE PROTECTED BY AN APPROVED AUTOMATIC FIRE SPRINKLEY SYSTEM. FIRE CODE 304.3.3. <br />13. PROVIDE APPROVED SIGNS OR OTHER APPROVED NOTICES OR MARKINGS THAT INCLUDE THE WORDS "NO PARKING - FIRE LANE." SIGNS <br />SHALL HAVE A MINIMUM DIMENSION OF 12 INCHES WIDE BY 18 INCHES HIGH AND HAVE RED LETTERS ON A WHITE REFLECTIVE BACKGROUND. <br />SIGNS SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS, TO CLEARLY INDICATE THE ENTRANCE TO SUCH ROAD, OR PROHIBIT THE <br />OBSTRUCTION THEREOF AND AT INTERVALS AS REQUIRED BY THE FIRE INSPECTOR. FIRE CODE 503.3. <br />14. THE MAIN EXIT SHALL COMPLY WITH TITLE 24, SECTION 1007.2.1. <br />15. THE MAXIMUM OCCUPANT LOAD FOR AN ASSEMBLY USE SHALL NOT EXCEED THE OCCUPANT LOAD AS DETERMINED IN ACCORDANCE WITH <br />TITLE 24, SECTION 1004.1.2, AND TABLE 1004.1.2. <br />16. PROVIDE APPROVED PANIC HARDWARE ON REQUIRED EXIT DOORS, TITLE 24, SECTIONS 1007.2.5 & 1003.3.1.9. <br />17. COMPLY WITH POSTING OF ROOM CAPAICTY. FIRE CODE 2501.16.1 TITLE 24, SECTION 1007.2.6. (SUBJECT TO FIELD INSPECTION APPROVAL). <br />18. THE FIRE SPRINKLER SYSTEM SHALL BE CALCULATED PER CFC: CHAPTER 9, SECTION 903.1.1. <br />19. PROVIDE A MINIMUM UNOBSTRUCTED WIDTH OF 26 FEET, EXCLUSIVE OF SHOULDERS, EXCEPT FOR APPROVED SECURITY GATES IN <br />ACCORDANCE WITH SECTION 503.6, AND AN UNOBSTRUCTED VERTICAL CLEARANCE "CLEAR TO SKY" FIRE DEPARTMENT VEHICULAR ACCESS TO <br />WITHIN 150 FEET OF ALL PORTIONS OF THE EXTERIOR WALLS OF THE FIRST STORY OF THE BUILDING. AS MEASURED BY AN APPROVED ROUTE <br />AROUND THE EXTERIOR OF THE BUILDING FIRE CODE 503.1.1 & 503.2.2. <br />Approv�e� <br />OR PERMIT ISS N <br />Master ID: <br />Hate: <br />�SE� ARCy <br />o.-C 306 <br />N9TFFN 10 3N �Q`, <br />0 F C <br />REFERENCE KEYNOTES <br />O SHEET NOTES <br />1 PLAN SHEET NOTE 1 <br />2 PLAN SHEET NOTE 2 <br />3 PLAN SHEET NOTE 3 <br />SITE SYMBOLS <br />EXISTING BUILDING - NOT IN CONTRACT <br />NEW ASPHALTIC PAVING <br />[E]NEW CONCRETE <br />NEW LANDSCAPE <br />O <br />O <br />RUBBERIZED SURFACE FOR PLAYGROUND <br />U <br />C) <br />(E) CHAIN LINK FENCE <br />U_ <br />(E) DOUBLE SWING GATE <br />■ <br />O <br />� <br />E <br />( ) SINGLE SWING GATE <br />co <br />co <br />(E) ROLLING GATE <br />LL I <br />- <br />(E) PATH OF TRAVEL <br />73 <br />LL1 <br />> <br />- - - <br />PATH OF TRAVEL <br />(10 <br />0 <br />ry <br />(E) LIGHT POST75 <br />tiV <br />Y <br />(N) LIGHT POST <br />M <br />O <br />■ <br />-oo- <br />(E) STREET LIGHT <br />_II._j <br />rVn, <br />w <br />� <br />(D (E) TREES <br />(N) TREES <br />(N) ORNAMENTAL FENCING <br />CONSTRUCTION <br />DOCUMENTS <br />Issue Date <br />REVISIONS <br />75-24272-01 <br />LOCAL FIRE <br />ACCESS PLAN <br />7 <br />Lo <br />O <br />N <br />N <br />Lo <br />N <br />O <br />N <br />