My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5306 W McFadden Ave - Plan
PBA
>
Building
>
ProjectDox
>
M
>
McFadden Ave
>
5306 W McFadden Ave
>
5306 W McFadden Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 10:50:47 AM
Creation date
2/24/2026 10:50:27 AM
Metadata
Fields
Template:
Plan
Permit Number
101122413
101122414
Full Address
5306 W McFadden Ave
Street Number
5306
Street Direction
W
Street Name
McFadden
Street Suffix
Ave
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
447
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ST. BARBARA CATHOLIC SCHOOL TASK 2 75-24272-01 <br />DIOCESE OF ORANGE SEPTEMBER 12TH, 2024 <br />SANTA ANA, CA BID & PERMIT SET <br /> <br />STORM DRAINAGE 334100 - 5 <br />3. Perforations: Perforations in ABS and PVC pipe shall be circular, no more than <br />5/16" or less than 3/16" in diameter, and arranged in rows parallel to the longitu- <br />dinal axis of the pipe. Perforations shall be approximately 3 inches cen- <br />ter-to-center, along rows. The rows shall be approximately 1-1/2" inches apart <br />and arranged in a staggered pattern so that all perforations lie at the mid-point be- <br />tween perforations in adjacent rows. The rows shall be spaced over not more than <br />90 degrees of circumference. The spigot or tongue end of the pipe shall not be <br />perforated for a length equal to the depth of the socket and perforations shall con- <br />tinue at uniform spacing over the entire width of the pipe. Manufacturer's stand- <br />ard ABS or PVC pipe essentially meets these requirements and may be substitut- <br />ed upon approval. Wall thickness as required for earth loads and as approved by <br />Soils Engineer, 4" diameter, SDR35 minimum. <br />4. Acrylonitrile-butadiene-styrene (ABS) pipe shall be joined using solvent cement <br />or elastomeric joints and shall be in accordance with ASTM D 2751. <br />5. Polyvinyl Chloride (PVC) pipe joints shall be in accordance with ASTM D 3212. <br />6. Furnish subsoil drainage pipe prewrapped or wrap pipe with Mirafi 140N Filter <br />Fabric, or Bidim C22 or C28 fabric manufactured by Monsanto; or equal. <br />2.5 2.6 MANHOLES <br />A. Standard Precast Concrete Manholes: ASTM C 478, precast, reinforced concrete, of depth <br />indicated, with provision for sealant joints. <br />1. Diameter: 48 inchesminimum, unless otherwise indicated. <br />2. Ballast: Increase thickness of precast concrete sections or add concrete to base section, <br />as required to prevent flotation. <br />3. Base Section: 6-inchminimum thickness for floor slab and 4-inchminimum thickness for <br />walls and base riser section and having separate base slab or base section with integral <br />floor. <br />4. Riser Sections: 4-inchminimum thickness, and of length to provide depth indicated. <br />5. Top Section: Eccentric-cone type unless concentric-cone or flat-slab-top type is <br />indicated. Top of cone of size that matches grade rings. <br />6. Joint Sealant: ASTM C 990 bitumen or butyl rubber. <br />7. Resilient Pipe Connectors: ASTM C 923, cast or fitted into manhole walls, for each pipe <br />connection. <br />8. Steps: Individual FRP steps, FRP ladder, or ASTM A 615/A 615M, deformed, 1/2- <br />inchsteel reinforcing rods encased in ASTM D 4101, PP wide enough to allow worker to <br />place both feet on 1 step and designed to prevent lateral slippage off of step. Cast or <br />anchor steps into sidewalls at 12- to 16-inchintervals. Omit steps if total depth from floor <br />of manhole to finished grade is less than 60 inches <br />9. Adjusting Rings: Interlocking rings with level or sloped edge in thickness and diameter <br />matching manhole frame and cover. Include sealant recommended by ring manufacturer. <br />10. Grade Rings: Reinforced-concrete rings, 6- to 9-inchtotal thickness, to match diameter of <br />manhole frame and cover. <br />11. Manhole Frames and Covers: Ferrous; 24-inchID by 7- to 9-inchriser with 4-inch- <br />minimum width flange and 26-inch-diameter cover. Include indented top design with <br />lettering cast into cover, using wording "STORM DRAIN."
The URL can be used to link to this page
Your browser does not support the video tag.