My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5306 W McFadden Ave - Plan
PBA
>
Building
>
ProjectDox
>
M
>
McFadden Ave
>
5306 W McFadden Ave
>
5306 W McFadden Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 10:50:47 AM
Creation date
2/24/2026 10:50:27 AM
Metadata
Fields
Template:
Plan
Permit Number
101122413
101122414
Full Address
5306 W McFadden Ave
Street Number
5306
Street Direction
W
Street Name
McFadden
Street Suffix
Ave
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
447
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Project No.: D-6289-08 <br />St. Barbara Catholic School <br />Percolation -Infiltration Tests <br />• The borehole diameter was 8 inches. <br />• The bottom elevation of test holes is at or 12 inches below the <br />proposed invert of infiltration basin. <br />CITY OF SANTA ANA <br />Planning and Building Agency <br />may, lS. <br />Approved <br />FOR PERMIT ISSUANCE <br />• Groundwater observed was at 14 feet below the existing ground level. <br />• Infiltration basins are supposed to be at least 10 feet above the groundwater level. <br />• Rotate the auger until all the cuttings are removed. <br />• Sides of the hole were not smeared after drilling and there was no caving. <br />• The bottom of the test hole was covered with 2 inches of gravel prior to testing. <br />• Holes were filled with clear water to appropriate depths from the ground surface <br />(Minimum required is 5 x radius of the hole (5 x 4" = 20 inches) from the bottom. <br />• On these two locations, two consecutive measurements showed that more than 6 <br />inches of water seeped away in 25 minutes test (Pre -Percolation Data Sheets). No <br />pre-soaking overnight was required. Thus, the tests were run for at least an <br />additional hour (60 Minutes) with measurements taken every 10 minutes <br />(Percolation Test Results). The drop that occurs during the final reading is used to <br />calculate the percolation and then infiltration rate. Both Pre -Percolation data <br />Sheets and Field Percolation Test Results are presented on Plates 1 through 4 in <br />Appendix C, Infiltration calculations are presented on Plates 5 and 6 respectively <br />for PC-1 and PC-2 in Appendix D. Infiltration results using another method, <br />Reduction Factor Method, Rf are presented on Plates 7 and 8 for PC-1 and PC-2 <br />respectively in Appendix E. <br />• A sounder was used to determine the water level. <br />• Measurements were taken with a precision of 0.25 inches or better. <br />3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.