515 E Dyer Rd-EV Chargers & Parking lot - Plan
PBA
>
Building
>
ProjectDox
>
D
>
Dyer Rd
>
515 E Dyer Rd
>
515 E Dyer Rd-EV Chargers & Parking lot - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 10:50:41 AM
Creation date
2/24/2026 10:50:27 AM
Metadata
Fields
Template:
Plan
Permit Number
20186473
101124420
101124421
Full Address
515 E Dyer Rd
Street Number
515
Street Direction
E
Street Name
Dyer
Street Suffix
Rd
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
2L3 <br />1L2 <br />1L2 <br />1L2 <br />1L2 <br />2L3 <br />XFMR <br />PWR PNL <br />XFMR <br />PWR PNL <br />2L2 <br />2L2 <br />XFMR <br />PWR PNL1L2 <br />XFMR <br />PWR PNL1L2 2L2 <br />2L2 <br />2L2 <br />2L2 <br />2L2 <br />2025 LC DESIGNS INTELLECTUAL <br />PROPERTY NOTICE: <br />This drawing is the sole property of LC Designs. It <br />is loaned to the recipient for his/her confidential use <br />only; and in consideration of the loan of this <br />drawing, the recipient agrees that this drawing shall <br />not be reproduced, copied, loaned, nor used for any <br />purpose other than for which it is specifically <br />intended without the express consent of <br />LC Designs. <br />LC Designs, 2205 E Dory St, Goddard, KS 67052 <br />316-816-0771 <br />LC Designs <br />IDBA <br />R <br />MEMBER <br />AMERICAN INSTITUTE of <br />BUILDING DESIGN <br />KITTY HAWK ENGINEERING <br />BARRETT CROOK, PE, LEED AP <br />5306 MULHOLLAND DRIVE <br />SUMMERVILLE, SC 29485 <br />252-655-1056 <br />DT1.0 <br />EVSA INSTALLATION @ SINGLE PARKING & 2 <br />LVL 3 CHARGER <br />SCALE: NTS <br />EVSA INSTALLATION @ DUAL PARKING & <br />(1) LVL 2 CHARGER EACH SIDE <br />SCALE: NTS <br />6" BOLT DOWN <br />BOLLARD <br />(SEE DTL 18 CV5.0) <br />(2) LVL 3 CHARGER ON <br />(1) PEDESTAL <br />6" BOLT DOWN <br />BOLLARD <br />(SEE DTL 18 CV5.0) <br />(2) LVL 2 CHARGERS ON <br />(1) PEDESTAL <br />PNL 1 & XFRAM INSTALLATION IN PARKING AREA <br />SCALE: NTS <br />6" BOLT DOWN <br />BOLLARD <br />(SEE DTL 18 CV5.0) <br />EVSA INSTALLATION @ SINGLE PARKING & <br />(2) LVL 2 CHARGERS @ CURB <br />SCALE: NTS <br />(2) LVL 2 CHARGERS ON <br />(1) PEDESTAL <br />6" BOLT DOWN <br />BOLLARD <br />(SEE DTL 18 CV5.0) <br />PNL 1 & XFRAM INSTALLATION <br />@ CURB AREA A6 <br />SCALE: NTS <br />6" BOLT DOWN <br />BOLLARD <br />(SEE DTL 18 CV5.0) <br />PARKING <br />STALL <br />PARKING <br />STALL <br />PARKING <br />STALL PARKING <br />STALL <br />EVSA INSTALLATION @ DUAL PARKING & <br />(4) LVL 2 CHARGERS <br />SCALE: NTS <br />6" BOLT DOWN <br />BOLLARD <br />(SEE DTL 18 CV5.0) <br />PARKING <br />STALL <br />11'X27'(TYP) <br />(2) LVL 2 CHARGERS ON <br />(1) PEDESTAL <br />GENERAL NOTES: <br />1. ELECTRICAL ENGINEER TO DETERMINE CONDUIT SIZING AND SPACING. <br />2. BOLLARD PLACEMENT SHALL BE DETERMINED BY CONTRACTOR TO <br />PROTECTS EV CHARGING EQUIPMENT. REFER TO DETAIL ON DT1.0 FOR <br />SIZE AND DEPTH. <br />3. EXISTING ADA CURBS AND RAMPS TO REMAIN AND BE PROTECTED. <br />4. EXISTING SIGNS, LIGHT POLES, BOLLARDS TO REMAIN AND BE <br />PROTECTED. <br />5. CONTRACTOR TO RETURN ALL AREAS OF DISTURBANCE BACK TO <br />ORIGINAL OR BETTER CONDITIONS. <br />6. PARKING STALLS ARE 11FT WIDE BY 27FT LONG UNLESS NOTED <br />OTHERWISE. <br />PARKING <br />STALL <br />11'X27'(TYP) <br />PARKING <br />STALL <br />11'X27'(TYP) <br />PARKING <br />STALL <br />11'X27'(TYP) <br />PARKING <br />STALL <br />11'X27'(TYP) <br />PARKING <br />STALL <br />11'X27'(TYP) <br />PARKING <br />STALL <br />11'X27'(TYP) <br />PARKING <br />STALL <br />11'X27'(TYP) <br />PARKING <br />STALL <br />11'X27'(TYP) <br />PARKING <br />STALL <br />11'X27'(TYP) <br />PARKING <br />STALL <br />11'X27'(TYP) <br />PARKING <br />STALL <br />11'X27'(TYP) <br />PARKING <br />STALL <br />11'X27'(TYP) <br />PARKING <br />STALL <br />11'X27'(TYP) <br />PARKING <br />STALL <br />11'X27'(TYP) <br />PARKING <br />STALL <br />11'X27'(TYP) <br />PARKING <br />STALL <br />11'X27'(TYP) <br />PARKING <br />STALL <br />11'X27'(TYP) <br />PARKING <br />STALL <br />11'X27'(TYP) <br />PARKING <br />STALL <br />11'X27'(TYP) <br />PARKING <br />STALL <br />11'X27'(TYP) <br />PARKING <br />STALL <br />11'X27'(TYP) <br />PARKING <br />STALL <br />11'X27'(TYP) <br />PARKING <br />STALL <br />11'X27'(TYP) <br />ELECTRICAL EQUIPMENT BY OTHERS <br />5'-2"12 <br />" <br />9" <br />PARKING <br />STALL <br />11'X27'(TYP) <br />PARKING <br />STALL <br />11'X27'(TYP) <br />3'-4" <br />12 <br />" <br />9" <br />PARKING <br />STALL <br />11'X27'(TYP) <br />PARKING <br />STALL <br />11'X27'(TYP) <br />8' <br />6" <br />6" <br />3' <br />- <br />9 <br />" <br />3'-4" <br />3' <br />- <br />9 <br />" <br />9" <br />6" <br />PARKING <br />STALL <br />11'X27'(TYP) <br />PARKING <br />STALL <br />11'X27'(TYP) <br />PARKING <br />STALL <br />11'X27'(TYP) <br />PARKING <br />STALL <br />11'X27'(TYP) <br />TRANSFORMER <br />PANEL <br />6'-4" <br />8' <br />- <br />8 <br />" <br />1' <br />- <br />6 <br />" <br />2' <br />1' <br />- <br />9 <br />" <br />1'-9" <br />TRANSFORMER <br />PANEL <br />5' <br />- <br />1 <br />0 <br />" <br />5' <br />- <br />1 <br />0 <br />" <br />5' <br />- <br />1 <br />0 <br />" <br />5' <br />- <br />1 <br />0 <br />" <br />5' <br />- <br />1 <br />0 <br />" <br />5' <br />- <br />1 <br />0 <br />" <br />5' <br />- <br />1 <br />0 <br />" <br />1'-9" <br />7" <br />10 <br />" <br />2'-11"2'-11"