Laserfiche WebLink
8'-0" O.C. MIN. (TYP.)CHANNEL <br />CONDUIT CLAMPS <br />HINGED BEAM CLAMP <br />CONDUIT CLAMPS <br />3" OR 2-1/2" CONDUIT <br />CENTER BETWEEN PANEL POINTS <br />OR ONE IN EACH PANEL POINT (TYP.) <br />SIDE VIEW <br />CONDUIT MOUNTING PARALLEL TO JOISTS CONDUIT MOUNTING PERPENDICUALR TO JOISTS <br />SECTION VIEW <br />SIDE VIEW SECTION VIEW <br />CENTER BETWEEN PANEL POINTS <br />OR ONE IN EACH PANEL POINT <br />HINGED BEAM CLAMP <br />(Ø1/2" THRD. ROD) <br />EXISTING STEEL BAR JOIST <br />3" OR 2-1/2" CONDUIT <br />CHANNEL <br />CHANNEL NUT <br />(Ø1/2" THRD. ROD) <br />CHANNEL <br />EXISTING STEEL BAR JOIST <br />HINGED BEAM CLAMP <br />EXISTING STEEL BAR JOIST <br />(Ø1/2" THRD. ROD)3" OR2-1/2" CONDUIT <br />CONDUIT CLAMPS <br />(N) MV TRANSFORMER <br />(N) LV SWITCHBOARD <br />(N) 208V <br />PANELBOARD <br />(N) 480V:208V <br />TRANSFORMER <br />(E) STEEL BAR JOIST <br />CONDUIT CLAMPS <br />3" OR 2-1/2" CONDUIT <br />HINGED BEAM CLAMP <br />(Ø1/2" THRD. ROD) <br />CHANNEL <br />NTS6SUSPENDED CONDUIT MOUNTING <br />VERTICAL CONDUIT RACK DETAIL <br />GROUND <br />3 1/2" <br />8" <br />2 3/4" <br />8". <br />NTS3 <br />STRUT CHANNEL <br />(2) 1-5/8" 12 GAUGE GALVANIZED STEEL CHANNEL <br />W/ 9/16"x1-1/8" SLOTS 2" ON CENTER <br />1" OR 1-1/4" CONDUIT ENTRANCE TO PANEL <br />PROVIDE FLEXIBLE METAL CONDUIT FROM EMT CONDUIT <br />RACK TO PANEL. FMC CONDUIT LENGTH SHALL BE LESS <br />THAN 4'0". IF DISTANCE IS GREATER, PROVIDE REQUIRED <br />SUPPORTS. <br />PROVIDE UL LISTED RAINTIGHT CONDUIT HUB CONNECTION <br />AT PANEL CONNECTION, PROVIDE APPROPRIATE SIZE <br />KNOCKOUT AS REQUIRED. MAINTAIN NEMA 3R RATING FOR <br />PANEL ENCLOSURE. <br />POST BASE <br />6" x 6" x 3-1/2"H <br />3-1/2" WEDGE ANCHOR 5/8" x 3-1/2" <br />STAINLESS STEEL WITH 2" THREAD LENGTH <br />W/ WASHER AND NUT <br />208V PANELBOARD <br />GROUND <br />600A OR 800A PANELBOARD RACK <br />NTS1EQUIPMENT CONDUIT ROUTING PROFILE VIEW <br />NTS2 <br />UL SYSTEM #C-AJ-1001 <br />CONCRETE WALL <br />METAL PIPE OR CONDUIT <br />1/4" (6MM) MIN. BEAD OF <br />CP 25N/S CAULK <br />METAL SLEEVE <br />DAMMING MATERIAL <br />CONDUIT PENETRATION-CONCRETE WALL <br />NTS7 <br />NTS8CONDUIT SUPPORT <br />CONCRETE CEILING, <br />WALL, OR COLUMN <br />CONDUIT <br />OPTION 1 <br />UNISTRUT 2-HOLE <br />CONDUIT STRAP <br />(TYPICAL) <br />3/8" HILTI KWIK-BOLT <br />TZ ANCHORS. <br />ESR-1917. <br />DETAIL 4 <br />DETAIL 8 <br />DETAIL 6 <br />DETAIL 3 DETAIL 1 <br />CONDUIT SUPPORT <br />REQUIRED EVERY 10' <br />WHETHER ON WALL, <br />CEILING, COLUMN <br />OR STRUT RACK. <br />OPTION 2 <br />CONDUIT HANGAR STRUT <br />CLAMP, MIN 12 GAUGE, HDG, <br />TYP. <br />1-1/2" X 1-1/2'" KINDORF <br />UNISTRUT OR EQUAL <br />1-1/2" X 1-1/2'" KINDORF <br />UNISTRUT OR EQUAL <br />FOR SOLID MASONRY OR <br />CONCRETE USE MINIMUM 3/8" <br />LAG BOLTS AND SHIELDS. <br />MINIMUM 2 PER CHANNEL. <br />FOR HOLLOW MANSONRY USE <br />MINIMUM 3/8" TOGGLE BOLTS. <br />MINIMUM 2 PER CHANNEL. <br />SURFACE EQUIPMENT MOUNTING <br />NTS5 LVSB-1 FRONT VIEW - PULL SECTION <br />NTS4 <br />MAIN <br />GENERATOR <br />CONTRACTOR TO REMOVE <br />SIDE PANEL AND/OR OTHER <br />BARRIERS TO ATTACH PULL <br />SECTION <br />MAIN LUGS TO <br />BE 20" AFF <br />DISTRIBUTION <br />NEW PULL <br />SECTION <br />AMAZON <br />PROVIDED <br />FINISHED FLOOR <br />FINISHED FLOOR <br />CONDUIT <br />PENETRATION <br />THROUGH EXTERIOR <br />WALL. <br />DETAIL 5 & 7 <br />DETAIL 4 <br />DETAIL 8 <br />NO GENERATOR IS TO BE <br />INSTALLED UNDER THIS <br />DESIGN. GENERATOR <br />CONNECTION MUST BE PER <br />FUTURE PERMIT. <br />C <br />PH: <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />DA <br />T <br />E <br />2/ <br />1 <br />9 <br />/ <br />2 <br />5 <br />Ci <br />t <br />y <br /> <br />o <br />f <br /> <br />C <br />a <br />r <br />l <br />s <br />b <br />a <br />d <br /> <br />C <br />o <br />m <br />m <br />e <br />n <br />t <br />s <br />A <br />45 <br />0 <br /> <br />L <br />A <br />M <br />B <br />E <br />R <br />T <br /> <br />A <br />V <br />E <br />, <br /> <br />P <br />A <br />L <br />O <br /> <br />A <br />L <br />T <br />O <br />, <br /> <br />C <br />A <br /> <br />9 <br />4 <br />3 <br />0 <br />6 <br />(8 <br />8 <br />8 <br />) <br /> <br />3 <br />4 <br />2 <br />- <br />7 <br />3 <br />8 <br />3 <br />ORIGINAL SIZE 24"X36" <br />REV: <br />PROJ: <br />DL <br />X <br />8 <br /> <br />E <br />L <br />E <br />C <br />T <br />R <br />I <br />C <br /> <br />V <br />E <br />H <br />I <br />C <br />L <br />E <br /> <br />C <br />H <br />A <br />R <br />G <br />I <br />N <br />G <br /> <br />S <br />T <br />A <br />T <br />I <br />O <br />N <br />S <br />51 <br />5 <br /> <br />E <br />A <br />S <br />T <br /> <br />D <br />Y <br />E <br />R <br /> <br />R <br />O <br />A <br />D <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />BSE14-2 <br />DLX8_EV_OSP <br />ALEXANDER SHORTS <br />PROFESSIONA L ENGINEER <br />ELECTRICALSTATE OF CALIFORNIA <br />E 21782 <br />7/ <br />1 <br />4 <br />/ <br />2 <br />5 <br />Ut <br />i <br />l <br />i <br />t <br />y <br /> <br />t <br />r <br />e <br />n <br />c <br />h <br /> <br />p <br />a <br />t <br />h <br />B <br />10/22/25 <br />SS <br />B <br />J <br /> <br />U <br />p <br />s <br />i <br />z <br />e <br />, <br /> <br />G <br />e <br />n <br />e <br />r <br />a <br />t <br />o <br />r <br /> <br />s <br />e <br />c <br />t <br />i <br />o <br />n <br />C <br />9/ <br />2 <br />2 <br />/ <br />2 <br />5 <br />ELECTRICAL DETAILS <br />E4.0 <br />IFP C