POST-INSTALLED ANCHOR NOTES <br />1. DESIGN CRITERIA IS BASED ON THE CONTROLLING GEOGRAPHICAL LOADINGS CONSIDERING <br />CLIENT-PROVIDED PROJECT LOCATIONS IN THE UNITED STATES. <br />2.THE DESIGN CRITERIA PERTAINING TO EACH SPECIFIC SITE WILL DIFFER FROM THE DESIGN CRITERIA <br />LISTED BELOW. THE DESIGN CRITERIA LISTED BELOW IS CONSERVATIVE RELATIVE TO THE SITE SPECIFIC <br />DESIGN WITH THE CONSIDERATION OF PROJECT GENERAL NARRATIVE AND REQUIREMENTS OF NOTE 4, <br />ABOVE. <br />3.BUILDING CODE: <br />2021 INTERNATIONAL BUILDING CODE <br />4.DESIGN LOADS <br />RISK CATEGORY = II <br />DEAD LOAD: <br />SELF WEIGHT OF MATERIAL <br />WIND: <br />DESIGN WIND SPEED (3 SEC. GUST) = 96 MPH (ULTIMATE) <br />WIND EXPOSURE = C <br />SEISMIC: <br />SEISMIC IMPORTANCE FACTOR, IE = 1.0 <br />MAPPED SPECTRAL RESPONSE ACCELERATION PARAMETERS: <br />SS = 1g <br />SI = 0.354g <br />SITE CLASS = D, DEFAULT <br />DESIGN SPECTRAL RESPONSE ACCELERATION PARAMETERS: <br />SDS = 0.733g <br />SDI = N/Ag <br />SEISMIC DESIGN CATEGORY = D <br />RESPONSE MODIFICATION COEFFICIENT (Ra) = 3.0 <br />FROST DEPTH = 0" <br />1.UNLESS OTHERWISE INDICATED ON PLANS, POST-INSTALLED ANCHORS SHOULD CONSIST OF THE FOLLOWING ANCHOR TYPES, <br />OR APPROVED EQUAL: <br />HILTI KH-EZ SS316 <br />2.SUBSTITUTION REQUESTS FOR ALTERNATE PRODUCTS MUST BE APPROVED IN WRITING BY THE STRUCTURAL ENGINEER OF <br />RECORD PRIOR TO USE. CONTRACTOR SHOULD PROVIDE CALCULATIONS DEMONSTRATING THAT THE SUBSTITUTED PRODUCT IS <br />CAPABLE OF ACHIEVING THE PERFORMANCE VALUES OF THE SPECIFIED PRODUCT. SUBSTITUTIONS WILL BE EVALUATED BY <br />THEIR HAVING AN ICC ESR SHOWING COMPLIANCE WITH THE RELEVANT AND CURRENT BUILDING CODE. <br />CONCRETE AND REINFORCEMENT <br />1.CAST-IN-PLACE CONCRETE SHOULD BE F'C = 4,500 PSI MIN (CLASS F2), W/C = 0.45 MAX, AND TARGET AIR CONTENT OF 6% ± 1.5%, <br />UNLESS NOTED OTHERWISE. MAXIMUM AGGREGATE SIZE IS 1". <br />2.REINFORCING SHOULD CONFORM TO ASTM A615, GRADE 60, Fy = 60,000 PSI. <br />3.HOOKS AND BENDS FOR REINFORCING BARS SHOULD CONFORM TO THE REQUIREMENTS OF THE ADOPTED ACI 318. <br />4. ALL BEND DIMENSIONS FOR REINFORCING STEEL SHOULD BE OUT-TO-OUT OF BARS. ALL PLACEMENT DIMENSIONS FOR <br />REINFORCING STEEL SHOULD BE TO CENTER OF BARS UNLESS NOTED OTHERWISE. <br />5.ALL REINFORCING SHOULD HAVE 2" CLEAR COVER UNLESS NOTED OTHERWISE. <br />6.ALL EXPOSED CONCRETE CORNERS SHOULD BE CHAMFERED3 4". <br />7. TRIM ALL REINFORCING 2" CLEAR OF OPENINGS. USE #4X4 CENTERED ON CORNER OF OPENINGS. <br />1. FOUNDATIONS ARE DESIGNED USING PRESUMPTIVE SOIL VALUES IN ACCORDANCE WITH THE 2021 INTERNATIONAL BUILDING <br />CODE. <br />2. ALL FOOTING EXCAVATIONS SHOULD BE INSPECTED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACING CONCRETE. <br />3.IBC PRESUMPTIVE VERTICAL BEARING CAPACITY:1,500PSF <br />4. IBC PRESUMPTIVE LATERAL BEARING CAPACITY: 100 PCF <br />5.CONTRACTOR SHOULD ENGAGE A GEOTECHNICAL TESTING LABORATORY LICENSED IN THE STATE OF THE PROJECT TO CONFIRM <br />SOIL PREPARATION AND SPECIFY PROCEDURES AND SPECIFY COMPACTING REQUIREMENTS NECESSARY TO OBTAIN THE DESIGN <br />SOIL PROPERTIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT ENGINEER OF RECORD IF ASSUMED SOIL <br />PROPERTIES CANNOT BE OBTAINED ON SITE. <br />FOUNDATIONS <br />1.THESE CONSTRUCTION DOCUMENTS ARE SPECIFICALLY APPLICABLE TO FOUNDATIONS SUPPORTING THE COMPONENTS LISTED <br />BELOW. THE INFORMATION IN THIS TABLE MAY VARY DEPENDING ON FINAL CLIENT PROCUREMENT DECISIONS. CONTRACTOR AND <br />CLIENT TO CONFIRM FINAL PROCUREMENT SELECTIONS WITH ENGINEER PRIOR TO CONSTRUCTION. <br />2.EQUIPMENT YIELDING MAXIMUM EQUIVALENT UNIFORM AREA LOAD WAS USED IN DESIGN OF EQUIPMENT PADS. <br />3.FOUNDATION DESIGN IS BASED ON THE DESIGN CRITERIA. <br />4.IF THE PROJECT IS LOCATED IN AN AREA CLASSIFIED AS SITE CLASS E OR F, A SITE-SPECIFIC GEOTECHNICAL ANALYSIS IS <br />REQUIRED AND THE ENGINEER OF RECORD SHOULD BE CONTACTED IMMEDIATELY. <br />5.THE CONTRACTOR'S SCOPE OF WORK FOR THIS PROJECT SHOULD INCLUDE ALL COORDINATION, MATERIALS, LABOR, AND <br />OVERHEAD NECESSARY FOR COMPLETION OF THE FOLLOWING: <br />A. ALL STRUCTURES ARE DESIGNED TO ACT AS A STRUCTURAL UNIT UPON COMPLETION. CONTRACTOR SHOULD DESIGN AND <br />PROVIDE NECESSARY BRACING, TEMPORARY SUPPORTS, AND SHORING TO RESIST FORCES ON THE STRUCTURE DURING <br />CONSTRUCTION. <br />B. VERIFY ALL DIMENSIONS AND ELEVATIONS PRIOR TO STARTING WORK. NOTIFY THE ENGINEER OF ANY DISCREPANCIES. <br />C. VERIFY LOCATIONS OF ALL EXISTING UTILITIES PRIOR TO STARTING WORK. <br />D. CONTRACTOR MUST EXERCISE EXTREME CARE DURING THE EXCAVATION AND CONSTRUCTION FOR NEW STRUCTURE TO <br />AVOID DAMAGE TO EXISTING STRUCTURES. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL MEANS AND METHODS <br />REQUIRED TO FACILITATE CONSTRUCTION OF THE WORK AND ENSURING THE SAFETY, STABILITY AND INTEGRITY OF <br />ADJACENT STRUCTURES AND FACILITIES. <br />E. CONTRACTOR MUST ENGAGE A GEOTECHNICAL ENGINEER TO FIELD VERIFY SOIL PARAMETERS NOTED IN THE FOUNDATION <br />NOTES AND CONCRETE CLASS NOTED UNDER CONCRETE NOTES.DESIGN CRITERIA: <br />PROJECT GENERAL NARRATIVE AND REQUIREMENTS: <br />COMPONENT NAME COMPONENT DIMENSIONS <br />(WxHxD, FT) <br />COMPONENT WEIGHT <br />(LBS) <br />EQUIVALENT UNIFORM <br />AREA LOAD (PSF) <br />SWITCHGEAR 19'-6"x8'-9"x6'-0"17,900 152.99 <br />MV TAP SWITCH 8'-8 1/2"x4'-8 1 2"x6'-4 1/2"6,400 115.43 <br />MV TRANSFORMER 6'-0"x6'-1"x8'-3"14,500 292.93 <br />NOT TO SCALE2FOUNDATION FOR SWITCHGEAR AND MV TRANSFORMER <br />NOT TO SCALE1FOUNDATION FOR LV TRANSFORMER AND LVSB <br />TOP OF FOUNDATION <br />TOP OF PAD <br />NOTE: <br />-FOUNDATION DIMENSIONS ARE BASED ON STANDARD EQUIPMENT SIZING AND WILL <br />REQUIRE 6" CLEAR FROM EDGE OF EQUIPMENT TO EDGE OF PAD ON ALL SIDES. IF <br />THE PROCURED EQUIPMENT IS LARGER IN SIZE THAN WHAT THE PAD WILL ALLOW, <br />ENGINEER OF RECORD SHOULD BE CONTACTED AND LARGER PAD WILL BE <br />REQUIRED. <br />-TOP OF EQUIPMENT PAD IS INTENDED TO BE LEVEL. GC TO COORDINATE PAD <br />EMBEDMENT DEPTH WITH ACTUAL SITE GRADING PLANS. <br />-SOIL COMPACTION AND SUBBASE REQUIREMENTS TO BE COMPLETED BASED ON <br />THE LATEST GEOTECHNICAL REPORT WHICH WAS NOT PROVIDED TO THE ENGINEER <br />AS PART OF THIS DESIGN <br />10 <br />" <br />NOTE: <br />1) WHEN EMBEDDED BOLLARDS ARE REQUIRED PER SITE LAYOUT, BOLLARD TO BE PLACED IN ACCORDANCE <br />WITH PROVISIONS ON SHEET C5.1 DETAIL 17. FOUNDATIONS TO BE SPACED WITH A MINIMUM OF 6" BETWEEN <br />EDGE OF FOUNDATION. <br />14" <br />NOTE: <br />1) WHEN EMBEDDED BOLLARDS ARE REQUIRED PER SITE LAYOUT, BOLLARD TO BE PLACED IN ACCORDANCE <br />WITH PROVISIONS ON SHEET C5.1 DETAIL 17. FOUNDATIONS TO BE SPACED WITH A MINIMUM OF 6" BETWEEN <br />EDGE OF FOUNDATION. <br />6" <br />TYP 2"CLR <br />TYP. <br />EQUIPMENT WIDTH + 1'-0" <br />OR MINIMUM DIMENSIONS PER NOTES <br />14" <br />1'-0" TYP. <br />10 <br />" <br />EQUIPMENT WIDTH + 1'-0" <br />OR MINIMUM DIMENSIONS PER NOTES <br />6" <br />TYP <br />1'-0" TYP. <br />1'-0" TYP.1'-0" TYP. <br />EQUIPMENT <br />FREE DRAINING, NON-FROST <br />SUSCEPTIBLE AGGREGATE <br />FILL BELOW SPREAD FOOTING <br />FINISHED <br />GRADE <br />FINISHED GRADE <br />FREE DRAINING, NON-FROST <br />SUSCEPTIBLE AGGREGATE <br />FILL BELOW SPREAD FOOTING <br />EQUIPMENT <br />#7 AT 6" OC TO BE <br />CENTERED IN PAD <br />EACHWAY <br />#7 AT 6" OC TO BE <br />CENTERED IN PAD <br />EACHWAY <br />2024 LC DESIGNS INTELLECTUALPROPERTY NOTICE: <br />This drawing is the sole property of LC Designs. Itis loaned to the recipient for his/her confidential use <br />only; and in consideration of the loan of thisdrawing, the recipient agrees that this drawing shall <br />not be reproduced, copied, loaned, nor used for anypurpose other than for which it is specifically <br />intended without the express consent of <br />LC Designs. <br />LC Designs, 2205 E Dory St, Goddard, KS 67052316-816-0771 <br />LC Designs <br />IDBA <br />R <br />MEMBER <br />AMERICAN INSTITUTE of <br />BUILDING DESIGN <br />KITTY HAWK ENGINEERING <br />BARRETT CROOK, PE, LEED AP <br />5306 MULHOLLAND DRIVE <br />SUMMERVILLE, SC 29485 <br />252-655-1056 <br />C6.0