Anchor Fastening <br />CITY OF SANTA ANA <br />Planning and Building Agency <br />echnical Guide, Edition 22 <br />Table 6 - Load adjustment factors for 1/4-in. diameter Hilti KH-EZ, KH-EZ P, KH-EZ PM, KH�EZ PL anApproved <br />in uncracked concrete12 FOR PERMIT ISSUANCE <br />Edge distance in <br />hear <br />II t <br />and away <br />Spacing factor <br />Edge distance <br />Spacing factor <br />Conc. thickness fac- <br />1/4-in. KH-EZ <br />in tension <br />factor in tension <br />in shear' <br />_ toward edge <br />g10v��AI <br />for in shear <br />uncracked concrete <br />fAN <br />fRN <br />f av <br />f Rv <br />r <br />J RV. <br />f 1 11- <br />In. <br />1-5/8 <br />2-1/2 <br />1-5/8 <br />2-1/2 <br />1-5/8 <br />2-1/2 <br />1-5/8 <br />2-1/2 <br />1-5 <br />8 <br />=1/2 <br />1-5/8 <br />2-1/2 <br />Embedment h <br />(mm) <br />(41) <br />(64) <br />(41) <br />(64) <br />(41) <br />(64) <br />(41) <br />(64) <br />(4 <br />1-1/2 (38) <br />0.71 <br />0.63 <br />0.78 <br />0.65 <br />0.59 <br />0.56 <br />0.40 <br />0.21 <br />0.78 <br />0.42 <br />n/a <br />n/a <br />2 (51) <br />0.78 <br />0.67 <br />1.00 <br />0.77 <br />0.62 <br />0.58 <br />0.61 <br />0.33 <br />1.00 <br />0.65 <br />n/a <br />n/a <br />2-1/2 (64) <br />0.85 <br />0.72 <br />0.90 <br />0.65 <br />0.60 <br />0.86 <br />0.46 <br />0.90 <br />n/a <br />n/a <br />3 (76) <br />0.92 <br />0.76 <br />1.00 <br />0.68 <br />0.62 <br />1.00 <br />0.60 <br />1.00 <br />n/a <br />n/a <br />m <br />3-1/4 (83) <br />0.96 <br />0.78 <br />0.70 <br />0.63 <br />0.68 <br />0.88 <br />n/a <br />0 <br />3-1/2 (89) <br />0.99 <br />0.80 <br />0.71 <br />0.64 <br />0.76 <br />0.92 <br />n/a <br />4 (102) <br />1.00 <br />0.85 <br />0.74 <br />0.66 <br />0.92 <br />0.98 <br />n/a <br />m <br />4-1/8 (105) <br />0.86 <br />0.75 <br />0.66 <br />0.97 <br />1.00 <br />0.81 <br />. <br />ca <br />4-1/2 (114) <br />0.89 <br />0.77 <br />0.68 <br />1.00 <br />0.84 <br />N L <br />� y <br />5 (127) <br />0.93 <br />0.80 <br />0.70 <br />0.89 <br />m <br />5-1/2 (140) <br />0.98 <br />0.83 <br />0.72 <br />0.93 <br />� c <br />6 (152) <br />1.00 <br />0.86 <br />0.74 <br />0.97 <br />Q, <br />7 (178) <br />0.92 <br />0.78 <br />1.00 <br />c <br />E5 <br />co <br />8 (203) <br />0.98 <br />0.82 <br />cn <br />9 (229) <br />1.00 <br />0.86 <br />10 (254) <br />1 <br />1 <br />1 <br />1 <br />10.89 <br />11 (279) <br />0.93 <br />12 (305) <br />0.97 <br />14 (356) <br />1.00 <br />Table 7 - Load adjustment factors for 1/4-in. diameter Hilti KH-EZ, KH-EZ P, KH-EZ PM, KH-EZ PL and KH-EZ C <br />in cracked concrete',2 <br />Edge distance in shear <br />II to and away <br />Spacing factor <br />Edge distance <br />Spacing factor <br />Conc. thickness fac- <br />1/4-in. KH-EZ <br />in tension <br />factor in tension <br />in shear' <br />1. toward edge <br />from edge <br />for in shear' <br />cracked concrete <br />fAN <br />f RN <br />f Av <br />f Rv <br />f RV <br />f HV <br />in. <br />1-5/8 <br />2-112 <br />1-5/8 <br />2-1/2 <br />1-5/8 <br />2-1/2 <br />1-5/8 <br />2-112 <br />1-5/8 <br />2-1/2 <br />1-5/8 <br />2-1/2 <br />Embedment h <br />°°m (m m) <br />(41) <br />(64) <br />1 (41) <br />(64) <br />1 (41) <br />(64) <br />(41) <br />(64) <br />(41) <br />(64) <br />(41) <br />(64) <br />1-1/2 (38) <br />0.71 <br />0.63 <br />0.88 <br />0.65 <br />0.59 <br />0.56 <br />0.40 <br />0.21 <br />0.80 <br />0.43 <br />n/a <br />n/a <br />2 (51) <br />0.78 <br />0.67 <br />1.00 <br />0.77 <br />0.62 <br />0.58 <br />0.62 <br />0.33 <br />1.00 <br />0.66 <br />n/a <br />n/a <br />2-1/2 (64) <br />0.85 <br />0.72 <br />0.90 <br />0.65 <br />0.60 <br />0.87 <br />0.46 <br />0.90 <br />n/a <br />n/a <br />3 (76) <br />0.92 <br />0.76 <br />1.00 <br />0.68 <br />0.62 <br />1 1.00 <br />0.60 <br />1.00 <br />n/a <br />n/a <br />m <br />3-1/4 (83) <br />0.96 <br />0.78 <br />0.70 <br />0.63 <br />0.68 <br />0.89 <br />n/a <br />o <br />3-1/2 (89) <br />0.99 <br />0.80 <br />0.71 <br />0.64 <br />0.76 <br />0.92 <br />n/a <br />4 (102) <br />1.00 <br />0.85 <br />0.74 <br />0.66 <br />0.93 <br />0.98 <br />n/a <br />m <br />4-1/8 (105) <br />0.86 <br />0.75 <br />0.66 <br />0.97 <br />1.00 <br />0.81 <br />. <br />m - <br />4-1/2 (114) <br />0.89 <br />0.77 <br />0.68 <br />1.00 <br />0.85 <br />N L <br />a N <br />5 (127) <br />1 0.93 <br />0.80 <br />0.70 <br />1 <br />0.89 <br />o) a) <br />5-1/2 (140) <br />0.98 <br />0.83 <br />0.72 <br />1 0.93 <br />-d C <br />c2 <br />6 (152) <br />1.00 <br />0.86 <br />0.74 <br />0.98 <br />N <br />a� <br />7 (178) <br />0.92 <br />0.78 <br />1.00 <br />c <br />Ca <br />8 (203) <br />0.98 <br />0.82 <br />c) <br />9 (229) <br />1.00 <br />0.86 <br />10 (254) <br />1 <br />1 <br />1 <br />1 0.90 <br />11 (279) <br />0.94 <br />12 (305) <br />0.98 <br />14 (356) <br />1.00 <br />1 Linear interpolation not permitted. <br />2 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with thin concrete member) the design can become very conservative. To optimize the design, use <br />Hilti PROPS Engineering software or perform anchor calculation using design equations from ACI 318 Chapter 17. <br />3 Spacing factor reduction in shear, f_ assumes an influence of a nearby edge. If no edge exists, then fAv = fAN. <br />4 Concrete thickness reduction factor in shear, f. , assumes an influence of a nearby edge. If no edge exists, then f H = 1.0. <br />If a reduction factor value is in a shaded cell, this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa). <br />Check with table 5 and figure 2 of this section to calculate permissable edge distance, spacing and concrete thickness combinations. <br />Anchor Fastening Technical Guide Edition 22 13.0 ANCHORING SYSTEMS 1 3.3.6 KWIK HUS-EZ SCREW ANCHOR 335 <br />Hilti, Inc. 1-800-879-8000 1 en espanol 1-800-879-5000 1 www.hilti.com I Hilti (Canada) Corporation I www.hilti.ca 1 1-800-363-4458 <br />