Laserfiche WebLink
REF <br />DN <br />W/D W/D <br />W/D W/D <br />W/D W/D <br />DN <br />REF <br />REF <br />REF <br />REF <br />REF <br />(E) WALL TO REMAIN <br />1 HR FIRE RATED WALL <br />DOOR REFERENCE <br />WOOD STUD WALL: WOOD STUDS @ 16" O.C., UNLESS <br />OTHERWISE NOTED. <br />MILLWORK, SEE MILLWORK DETAILS <br />DOOR TAG SEE A6-1.1 <br />AT PLAM SURFACE: PROVIDE TOP MOUNT SINK <br />AT SOLID SURFACE: PROVIDE UNDER-MOUNT SINK <br />SINK: <br />0000A <br />(TYPICAL WALL TYPE A UNLESS OTHERWISE NOTED) SEE <br />WALL REFERENCE <br />1/A9-1.1 <br />A 6" <br />6'-0" <br />STUD SIZE <br />LOW PARTITION HEIGHT (WHERE OCCURS) <br />WALL TYPE <br />A <br />ACOUSTIC BATT INSULATION <br />4' <br /> <br />- <br /> <br />0 <br />" <br />7' <br /> <br />- <br /> <br />9 <br />" <br />536 SF <br />UNIT 201 <br />548 SF <br />UNIT 202 <br />534 SF <br />UNIT 203 <br />539 SF <br />UNIT 204 <br />544 SF <br />UNIT 205 <br />534 SF <br />UNIT 206 <br />002 <br />002 <br />002 <br />002 <br />003 <br />002 <br />002 <br />003 <br />003 <br />002 <br />002 <br />003 <br />002 <br />003 <br />002 <br />002 <br />002 <br />003 <br />004 <br />004 004 <br />004 <br />004004 <br />001 <br />001 <br />001 001 <br />001 <br />001 <br />13' - 2" <br />12' - 7" <br />3 <br />A4-2.1 <br />1 <br />A4-2.1 <br />LIVING & DINING <br />ROOM <br />BEDROOM <br />BATHROOM <br />KITCHEN <br />A <br />B <br />B <br />B <br />A <br />B <br />B <br />C <br />B <br />B <br />C <br />B <br />B <br />B <br />B <br />B <br />A <br />C <br />C <br />B <br />B <br />BEDROOM <br />B <br />A <br />B <br />B <br />C <br />B <br />BB <br />B <br />A <br />A <br />B <br />B <br />C C <br />B B <br />B <br />A <br />B <br />B <br />A <br />C <br />BEDROOM <br />BEDROOM <br />BEDROOM <br />BEDROOM <br />BEDROOM <br />BEDROOM <br />BEDROOM <br />BEDROOM <br />BEDROOM <br />BEDROOM <br />LIVING & DINING <br />ROOM <br />LIVING & DINING <br />ROOM <br />LIVING & DINING <br />ROOM LIVING & DINING <br />ROOM <br />LIVING & DINING <br />ROOM <br />BATHROOM <br />BATHROOM BATHROOM <br />BATHROOM <br />BATHROOM <br />KITCHEN <br />KITCHENKITCHEN <br />KITCHEN KITCHEN <br />14' - 6 1/4"12' - 2" <br />12 <br />' <br /> <br />- <br /> <br />3 <br />" <br />9' <br /> <br />- <br /> <br />1 <br /> <br />1 <br />/ <br />4 <br />" <br />8' <br /> <br />- <br /> <br />1 <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br />12 <br />' <br /> <br />- <br /> <br />6 <br />" <br />9' <br /> <br />- <br /> <br />0 <br />" <br />12 <br />' <br /> <br />- <br /> <br />8 <br /> <br />1 <br />/ <br />2 <br />" <br />12' - 2"15' - 1 1/4"14' - 9 3/4"12' - 5 1/2" <br />12 <br />' <br /> <br />- <br /> <br />3 <br />" <br />8' <br /> <br />- <br /> <br />1 <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br />12 <br />' <br /> <br />- <br /> <br />6 <br /> <br />1 <br />/ <br />2 <br />" <br />9' <br /> <br />- <br /> <br />0 <br /> <br />3 <br />/ <br />4 <br />" <br />8' <br /> <br />- <br /> <br />1 <br />1 <br /> <br />1 <br />/ <br />4 <br />" <br />12 <br />' <br /> <br />- <br /> <br />9 <br /> <br />1 <br />/ <br />4 <br />" <br />11' - 10 1/2"14' - 9 3/4" <br />9' <br /> <br />- <br /> <br />5 <br />" <br />4' <br /> <br />- <br /> <br />7 <br /> <br />1 <br />/ <br />4 <br />" <br />7' <br /> <br />- <br /> <br />0 <br /> <br />1 <br />/ <br />2 <br />" <br />9' <br /> <br />- <br /> <br />8 <br /> <br />1 <br />/ <br />2 <br />" <br />9' <br /> <br />- <br /> <br />5 <br />" <br />4' <br /> <br />- <br /> <br />6 <br /> <br />3 <br />/ <br />4 <br />" <br />4' <br /> <br />- <br /> <br />1 <br />1 <br /> <br />1 <br />/ <br />4 <br />" <br />9' <br /> <br />- <br /> <br />8 <br /> <br />1 <br />/ <br />2 <br />" <br />2 <br />A4-2.1 <br />SEE A5-1.5 <br />FOR ENLARGED <br />UNIT PLANS <br />SEE A5-1.5 <br />FOR ENLARGED <br />UNIT PLANS <br />SEE A5-1.5 <br />FOR ENLARGED <br />UNIT PLANS <br />SEE A5-1.5 <br />FOR ENLARGED <br />UNIT PLANS <br />SEE A5-1.5 <br />FOR ENLARGED <br />UNIT PLANS <br />SEE A5-1.5 <br />FOR ENLARGED <br />UNIT PLANS <br />6' - 0"6' - 11 3/4"8' - 3"6' - 2" <br />4' <br /> <br />- <br /> <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br />7' - 4 1/4"6' - 10" <br />4' <br /> <br />- <br /> <br />5 <br /> <br />1 <br />/ <br />2 <br />" <br />7' <br /> <br />- <br /> <br />1 <br />" <br />4' <br /> <br />- <br /> <br />1 <br />1 <br /> <br />1 <br />/ <br />4 <br />" <br />4' <br /> <br />- <br /> <br />5 <br /> <br />1 <br />/ <br />2 <br />" <br />8' - 1" <br />3' <br /> <br />- <br /> <br />8 <br />" <br />KG <br />K <br />B <br />M <br />B <br />B <br />K <br />HG <br />N <br />N <br />N <br />N <br />GK <br />B <br />M <br />B <br />B <br />K <br />GH5' - 7" <br />K <br />OO <br />RR <br />TYP.SN.02 <br />TYP.SN.02 <br />TYP.SN.02 <br />TYP.SN.02 <br />TYP.SN.02 <br />TYP.SN.02 <br />TYP.SN.02 <br />TYP.SN.02 <br />TYP.SN.02 <br />TYP.SN.02 <br />TYP.SN.02 <br />TYP.SN.02 <br />TYP.SN.02 <br />TYP.SN.02 <br />Renewal Date <br />LICENSED ARCHITECT <br />STATE OF C A L I FORNI <br />AEXP. 05/31/25 <br />J <br />C32284 <br />HOSHUAJAMESSMIT <br />WD PROJ. # DRAWN BY: CHECKED DATE <br />WESTGROUP DESIGNS, INC.© <br />ISSUED FOR: <br />REGISTRATION/SIGNATURE: <br />SHEET TITLE: <br />SHEET NUMBER: <br />REVISIONS: <br />23411 Yas Josh <br />2ND FLOOR <br />IMPROVEMENT PLAN <br />A2-1.2 <br />PLAN CHECK -10/23/2023 <br />2/18/25 <br />BEWLEY STREET <br />RESIDENCE <br />ILLUMINATION <br />FOUNDATION <br />914, 916, 918 N BEWLEY <br />STREET <br />SANTA ANA, CA 92703 <br />LEGEND <br />GENERAL NOTES <br />1. ALL WALLS FINISHED TO BE DRYWALL LEVEL 4 U.N.O. <br />2. GENERAL CONTRACTOR TO LAYOUT ALL CHALK LINES PRIOR TO PARTITION CONSTRUCTION. <br />SHOULD ANY DISCREPANCIES OCCUR, GENERAL CONTRACTOR IS TO REVIEW WITH THE <br />ARCHITECT IN THE FIELD TO RESOLVE PRIOR TO COMMENCEMENT OF CONSTRUCTION. <br />3. USE MOISTURE RESISTANT GYPSUM BOARD ON ALL RESTROOMS AND WET WALLS. <br />4. PROVIDE MINIMUM GYPSUM BOARD FURRING AROUND ALL EXPOSED COLUMNS TO 6" ABOVE <br />SUSPENDED CEILING. <br />5. PREPARE EXISTING AND NEW SURFACES FOR INSTALLATION OF SPECIFIED FINISHES. ALL <br />SURFACES SHALL BE FREE FROM ADHESIVE, BUMPS, CRACKS, AND MEET THE REQUIREMENTS <br />OF THE FINISH MANUFACTURERS INSTALLATION INSTRUCTIONS. <br />6. PROVIDE METAL TRIM OR CASING AT ALL EDGES OF CEMENT PLASTER AND GYPSUM BOARD <br />SURFACES WHERE IT TERMINATES OR MEETS ANY OTHER MATERIAL, U.N.O. <br />7. PROVIDE METAL CORNER BEAD AT ALL OUTSIDE CORNERS OF CEMENT PLASTER OR GYPSUM <br />BOARD SURFACES UNLESS NOTED OTHERWISE. <br />8. PRIOR TO INSTALLATION, FIRE AUTHORITY HAVING JURISDICTION SHALL BE CALLED TO FIELD <br />VERIFY LOCATIONS AND TYPES OF FIRE EXTINGUISHERS AND KNOX BOXES. <br />9. PROVIDE BACKING FOR ALL WALL MOUNTED EQUIPMENT AND MILLWORK PER DETAIL ##/A9-1.2. <br />COORDINATE WITH ARCHITECT FOR ANY UNFORSEEN CONDITIONS. <br />1/4" = 1'-0" <br />2nd FLOOR - IMPROVEMENT PLAN 1 <br />NORT <br />H <br />3 <br />2 PLAN CHECK CORRECTIONS 03/14/2025 <br />3 PLAN CHECK CORRECTIONS 04/09/2025 <br />SN# DESCRIPTION <br />SN.02 PROVIDE AND INSTALL R-13 INSULATION AT ALL EXTERIOR WALLS <br />SHEET KEYNOTES <br />PLAN CHECK - 04/09/2025 <br />4/09/25 <br />3 <br />3 <br />33 <br />3 <br />3 <br />914-918 N Bewley <br />St5/8/2025