Laserfiche WebLink
REF <br />REF <br />REF <br />REF <br />W/D <br />W/D <br />W/D <br />W/D <br />W/D <br />REF <br />RE <br />F <br />WH <br />WH <br />FINISH TAG - WALLS, FLOORS, BASE, MILLWORK <br />FINISH - TOP SURFACE <br />MILLWORK TAG <br />FINISH - FACE SURFACE <br />FLOOR FINISH 1 <br />FLOOR FINISH 2 <br />FLOOR MATERIAL TRANSITION, <br />SEE WHERE OCCURS. <br />X1 <br />T1 <br />F1 <br />/15 A9-1.1 <br />SEE A5-1.2 <br />FOR ENLARGED <br />UNIT PLANS <br />SEE A5-1.1 <br />FOR ENLARGED <br />UNIT PLANS <br />SEE A5-1.4 <br />FOR ENLARGED <br />UNIT PLANS <br />SEE A5-1.3 <br />FOR ENLARGED <br />UNIT PLANS <br />SEE A5-1.3 <br />FOR ENLARGED <br />UNIT PLANS <br />C1 <br />RF1 <br />C1T1 <br />C1 <br />C1 <br />RF1 <br />C1 <br />T1 <br />T1 <br />RF1 <br />RF1 <br />C1 <br />C1 <br />RF1 <br />C1 <br />C1 <br />C1 <br />T1 <br />T1 <br />T1 <br />C1 <br />C1 <br />RF1 <br />T1 <br />T1 <br />4 <br />1 <br />/ <br />2 <br />" <br />RF1 <br />P1 <br />B1 <br />P1 <br />B1 <br />P1 <br />B1 <br />P1 <br />Renewal Date <br />LICENSED ARCHITECT <br />STATE OF C A L I FORNI <br />AEXP. 05/31/25 <br />J <br />C32284 <br />HOSHUAJAMESSMIT <br />WD PROJ. # DRAWN BY: CHECKED DATE <br />WESTGROUP DESIGNS, INC.© <br />ISSUED FOR: <br />REGISTRATION/SIGNATURE: <br />SHEET TITLE: <br />SHEET NUMBER: <br />REVISIONS: <br />23411 Yas Josh <br />1ST FLOOR FINISH <br />PLAN <br />A2-2.1 <br />FO <br />R <br /> <br />C <br />O <br />N <br />S <br />T <br />R <br />U <br />C <br />T <br />I <br />O <br />N <br />PLAN CHECK -10/23/2023 <br />2/18/25 <br />BEWLEY STREET <br />RESIDENCE <br />ILLUMINATION <br />FOUNDATION <br />914, 916, 918 N BEWLEY <br />STREET <br />SANTA ANA, CA 92703 <br />LEGEND <br />FINISH SCHEDULE <br />TAG ITEM MANUFACTURER SPEC SIZE COLOR INSTALLATION NOTES CONTACT <br />B1 WALL BASE BY CONTRACTOR PAINT-GRADE FLAT STOCK MDF 4"H PAINT TO MATCH P1 - <varies> <varies> <br />C1 CARPET <varies> <varies> <varies> <varies> - - - <br />P1 PAINT SHERWIN WILLIAMS INTERIOR LATEX PAINT - SW7636 ORIGAMI WHITE - 1,2 ROCKY BERLANGA rocky.m.berlanga@sherwin.com <br />P2 PAINT DUNN EDWARDS INTERIOR LATEX PAINT - DEW380 WARM WHITE - 1,3 KIM HAMPTON kim.hampton@dunnedwards.com <br />P3 EXTERIOR PAINT DUNN EDWARDS ACRI-HUES EXTERIOR (ACHS10) - DE6213 FINE GRAIN - 1,4 KIM HAMPTON kim.hampton@dunnedwards.com <br />PL1 PLASTIC LAMINATE BY OWNER - - - - - <varies> <br />RF1 LUXURY VINYL TILE <varies> <varies> TBD. <varies> STAGGER - - <br />S1 QUARTZ PENTAL QUARTZ QUARTZ 65"X130" BQ8815P MISTERIO POLISHED - - KIM CLAYBORNE kim.clayborne@arcsurfaces.com <br />T1 PORCELAIN TILE BY OWNER - - - - - <br />T2 EXTERIO PORCELAIN TILE BY OWNER - - - - - <br />T3 EXTERIOR PAINT DUNN EDWARDS ACRI-HUES EXTERIOR (ACHS10) - DE6213 FINE GRAIN - 1,4 KIM HAMPTON kim.hampton@dunnedwards.com <br />T4 WALL TILE BY OWNER - - - - - <br />FINISH SCHEDULE NOTES <br />1. PRIOR TO FABRICATION PROVIDE DRAW DOWN FOR ARCHITECTS <br />REVIEW AND APPROVAL. <br />2. PROVIDE 2 COATS, EGGSHELL FINISH. <br />3. AT CEILINGS AND SOFFITS, PROVIDE 2 COATS, FLAT FINISH. <br />4. GROUT JOINT TO BE 1/8”, BASIS OF DESIGN: CUSTOM BUILDING <br />PRODUCTS PRISM ULTIMATE PERFORMACE GROUT, OR EQUAL. <br />5. STRAIGHT BASE AT CARPET, COVED BASE AT RESILIENT FLOORING. <br />6. INSTALL AT ALL EXPOSED SURFACES. <br />7. MITER ALL EXTERIOR CORNERS. <br />GENERAL NOTES <br />1. PRODUCTS SCHEDULED ARE TO ESTABLISH THE BASES OF DESIGN. SUBSTITUTION OF EQUAL OR <br />BETTER PRODUCTS WILL BE CONSIDERED IN ACCORDANCE WITH THE PROVISIONS IN THE PROJECT <br />SPECIFICATIONS. <br />2. FIELD MEASURE FOR ALL GLAZING AND MILLWORK CONDITIONS PRIOR TO MANUFACTURING. <br />3. PROVIDE TEMPORARY PROTECTION FOR ALL INSTALLED FINISHES AS WORK PROGRESSES. <br />4. INSTALL WALL FINISH FOR THE FULL HEIGHT OF THE PARTITION WITHOUT BASE. THERE SHALL BE NO <br />UNFINISHED GAPS AT THE BASE OF GYPSUM BOARD <br />5. ALL EXISTING WALLS TO BE PAINTED, U.N.O. <br />6. ALL METAL ACCESS DOORS SHALL BE PAINTED TO MATCH ADJACENT WALL OR CEILING FINISH. <br />7. PREPARE ALL FLOORS TO RECEIVE NEW FINISHES IN ACCORDANCE WITH THE MANUFACTURERS <br />INSTALLATION REQUIREMENTS. <br />8. PRIOR TO INSTALLATION OF FLOORING, SUBMIT WRITTEN CERTIFICATION BY FLOORING <br />MANUFACTURER AND ADHESIVE MANUFACTURER THAT CONDITION OF SUB-FLOOR IS ACCEPTABLE. <br />CONTRACTOR TO COMPLETE MOISTURE TESTING PER PER ASTM F-710, ASTM-F 2170-11 AND ASTM <br />F-1869-10 RECOMMENDATIONS AND SUBMIT TO ARCHITECT FOR REVIEW. OBTAIN INSTRUCTIONS IF <br />TEST RESULTS ARE NOT WITHIN LIMITS RECOMMENDED BY FLOORING MATERIALS MANUFACTURER. <br />9. PROVIDE ALLOWANCE TO FLOAT FLOOR WHERE NECESSARY TO ACHIEVE TOLERANCE OF 1/4" MAX. <br />IN 10'-0" SPAN. <br />10. ALL CERAMIC, PORCELAIN, AND VCT TO BE INSTALLED WITH FULL TILE FROM TRANSITION AT DOOR <br />AND FULL TILE FROM WALL PERPENDICULAR TO DOOR, U.N.O. <br />11. COORDINATE THE INSTALLATION OF WALL BASE WITH ANY MILLWORK. DELETE BASE WHERE BUILT- <br />IN CABINETS ARE INDICATED. <br />1/4" = 1'-0" <br />1st FLOOR - FINISH PLAN 1 <br />NORT <br />H <br />03/24/25 <br />914-918 N Bewley <br />St5/8/2025