Laserfiche WebLink
1 <br />A4-2.1 <br />UNIT 101 <br />UNIT 100 <br />UNIT 100 <br />UNIT 102 <br />UNIT 105 <br />UNIT 103 <br />UNIT 101 <br />LIVING ROOM <br />BEDROOM <br />BATHROOM <br />BEDROOM <br />KITCHEN <br />BATHROOM <br />WASHER/ <br />DRYER <br />CLOSET <br />BEDROOM <br />BEDROOMBATHROOM <br />KITCHEN <br />LIVING ROOM <br />WASHER/ <br />DRYER <br />BEDROOM <br />LIVING ROOM <br />DINING <br />KITCHEN <br />BEDROOM BATHROOMCORRIDOR <br />WASHER/ <br />DRYER <br />KITCHEN <br />DINING <br />BATHROOM <br />CORRIDORBEDROOM <br />LIVING ROOM <br />LIVING ROOM <br />WASHER/ <br />DRYER <br />KITCHEN <br />BATHROOMBEDROOM <br />RESTROOM <br />HALLWAY <br />BEDROOM <br />BEDROOM <br />WASHER/ <br />DRYER <br />STORAGE <br />SEE A5-1.2 <br />FOR ENLARGED <br />UNIT PLANS <br />SEE A5-1.1 <br />FOR ENLARGED <br />UNIT PLANS <br />SEE A5-1.4 <br />FOR ENLARGED <br />UNIT PLANS <br />SEE A5-1.3 <br />FOR ENLARGED <br />UNIT PLANS <br />SEE A5-1.3 <br />FOR ENLARGED <br />UNIT PLANS <br />A0-3.1 <br />11 <br />SN.01 <br />SN.01 <br />SN.01 <br />SN.01 <br />SN.01 <br />1 <br />A8-1.1 <br />1 <br />A8-1.1 <br />9 <br />A9-1.1 <br />9 <br />A9-1.1 <br />9 <br />A9-1.1 <br />9 <br />A9-1.1 <br />SN.01 <br />SN.01 <br />12 <br />A6-2.1 <br />INDICATES HEIGHT OF CEILING ABOVE FINISH FLOOR <br />(1) HOUR FIRE RATED GYPSUM BOARD CEILING TYPE (X) <br />X'-X" <br />CEILING LIGHT FIXTURES <br />CEILING FAN <br />EXTERIOR LIGHT FIXTURES <br />EXTERIOR LIGHT FIXTURES <br />2 <br />Renewal Date <br />LICENSED ARCHITECT <br />STATE OF C A L I FORNI <br />AEXP. 05/31/25 <br />J <br />C32284 <br />HOSHUAJAMESSMIT <br />WD PROJ. # DRAWN BY: CHECKED DATE <br />WESTGROUP DESIGNS, INC.© <br />ISSUED FOR: <br />REGISTRATION/SIGNATURE: <br />SHEET TITLE: <br />SHEET NUMBER: <br />REVISIONS: <br />23411 Yas Josh <br />1ST FLOOR RCP <br />A3-2.1 <br />FO <br />R <br /> <br />C <br />O <br />N <br />S <br />T <br />R <br />U <br />C <br />T <br />I <br />O <br />N <br />PLAN CHECK -10/23/2023 <br />2/18/25 <br />BEWLEY STREET <br />RESIDENCE <br />ILLUMINATION <br />FOUNDATION <br />914, 916, 918 N BEWLEY <br />STREET <br />SANTA ANA, CA 92703 <br />1/4" = 1'-0" <br />1st FLOOR - IMPROVEMENT RCP 1 <br />SHEET KEYNOTES SN.## <br />LEGEND <br />GENERAL NOTES <br />1. CENTER CEILING TILE IN ROOM U.N.O. <br />2. AT TEGULAR TILES, ALL EDGES TO BE FACTORY FINISH. IF NOT ABLE TO HAVE FACTORY <br />FINISH, CUT EDGES TO BE PAINTED TO MATCH TILE. <br />3. ALL GYPSUM BOARD CEILINGS AND SOFFITS TO BE FINISHED LEVEL 5. <br />4. NOTIFY WESTGROUP DESIGNS OF ANY DISCREPANCIES BETWEEN ARCHITECTURAL AND <br />ELECTRICAL OR MECHANICAL DRAWINGS AND OBTAIN CLARIFICATION BEFORE COMMENCING <br />WITH CONSTRUCTION. <br />5. LOCATE RECESSED DOWNLIGHTS, WALL WASHERS AND SPOT LIGHTS IN THE CENTER OF 2'X2' <br />CEILING TILES, U.N.O. <br />6. ALL CONDUIT AND HVAC DUCTS SHALL BE INDEPENDENTLY SUSPENDED FROM SAME <br />SUSPENSION AS CEILING SYSTEM. <br />7. ALL EQUIPMENT IN PLENUM TO BE LOCATED AWAY FROM GYPSUM BOARD CEILINGS. NO <br />ACCESS HATCHES IN GYPSUM BOARD CEILING WITHOUT PRIOR APPROVAL FROM ARCHITECT. <br />8. LIGHT SENSOR LOCATIONS AS DETERMINED BY THE ELECTRICAL ENGINEER SHALL BE FIELD <br />APPROVED BY ARCHITECT PRIOR TO INSTALLATION. <br />9. VERIFY ALL CLEARANCES IN PLENUM AREA AND ADVISE ARCHITECT OF MECHANICAL <br />EQUIPMENT THAT REQUIRES RELOCATION. <br />10. ALL FIRE ALARM SYSTEM, SMOKE DETECTION, AND LIFE SAFETY EQUIPMENT SHALL MATCH <br />BUILDING STANDARD. <br />11. PROVIDE FLUSH SPRINKLER HEAD COVERS AT ALL GYPSUM BOARD AND DECORATIVE <br />SPECIALTY CEILINGS. GC TO CONFIRM COLOR AND FINISH WITH ARCHITECT PRIOR TO <br />PROCUREMENT. <br />SN# DESCRIPTION <br />SN.01 EXTERIOR LIGHTING FIXTURE <br />NORT <br />H <br />03/24/25 <br />914-918 N Bewley <br />St5/8/2025