Laserfiche WebLink
REF <br />W/D <br />W/D <br />REF <br />REF <br />W/D <br />A5-1.22D 2A <br />2B <br />A5-1.21A <br />1B <br />1C <br />002 <br />003 <br />002 <br />004 <br />001 <br />7' <br /> <br />- <br /> <br />8 <br />" <br />3' <br /> <br />- <br /> <br />8 <br />" <br />3' <br /> <br />- <br /> <br />6 <br />" <br />2' <br /> <br />- <br /> <br />6 <br /> <br />1 <br />/ <br />4 <br />" <br />11' - 10 1/4"15' - 4 3/4" <br />9' <br /> <br />- <br /> <br />6 <br /> <br />3 <br />/ <br />4 <br />" <br />15 <br />' <br /> <br />- <br /> <br />0 <br />" <br />24 <br />' <br /> <br />- <br /> <br />6 <br /> <br />3 <br />/ <br />4 <br />" <br />27' - 3" <br />BEDROOM <br />LIVING ROOM <br />BEDROOM <br />BATHROOM <br />KITCHEN <br />B <br />B <br />C <br />B <br />B <br />B <br />UNIT 102 <br />101 <br />11' - 9 3/4" <br />3' <br /> <br />- <br /> <br />8 <br />" <br />3' <br /> <br />- <br /> <br />3 <br /> <br />1 <br />/ <br />4 <br />" <br />7' <br /> <br />- <br /> <br />1 <br /> <br />3 <br />/ <br />4 <br />" <br />8' - 0 1/4"3' - 6" <br />3' - 2 1/2" <br />P1 <br />C1 <br />B1 <br />P1 <br />RF1 <br />B1 <br />P1 <br />T1 <br />P1 <br />C1 <br />B1 <br />A5-1.1 <br />BEDROOM <br />BATHROOM <br />KITCHEN <br />LIVING ROOM <br />WASHER/D <br />RYER <br />BEDROOM <br />UNIT 102 <br />101 <br />2' <br /> <br />- <br /> <br />4 <br /> <br />1 <br />/ <br />2 <br />" <br />2' - 6"EQ EQ 2' - 6" <br />2' <br /> <br />- <br /> <br />5 <br /> <br />1 <br />/ <br />2 <br />" <br />2' <br /> <br />- <br /> <br />6 <br />" <br />EQ <br />EQ <br />2' - 6"2' - 6"EQ EQ <br />P2 <br />TYP. <br />U.N.O <br />2' <br /> <br />- <br /> <br />6 <br />" <br />2' <br /> <br />- <br /> <br />6 <br />" <br />EQ <br />EQ <br />1' - 3"5' - 8" <br />8' -0" <br />8' -0" <br />1' <br /> <br />- <br /> <br />6 <br />" <br />1' <br /> <br />- <br /> <br />6 <br />" <br />EQ <br />EQ <br />2' - 0"2' - 0"EQ EQ <br />2' - 6"3' - 8"4' <br /> <br />- <br /> <br />1 <br />0 <br />" <br />2' <br /> <br />- <br /> <br />2 <br />" <br />EQ EQ <br />3' <br /> <br />- <br /> <br />0 <br />" <br />1' <br /> <br />- <br /> <br />6 <br />" <br />9' -0" <br />8' -6" <br />9' -0" <br />9' -0" <br />8' -0" <br />9' -0" <br />A9-2.1 <br />8 <br />A9-2.1 <br />8 <br />A9-2.1 <br />1 <br />SN.01 <br />1' - 3" <br />CLR <br />3' - 0" <br />9' <br /> <br />- <br /> <br />0 <br />" <br />3' <br /> <br />- <br /> <br />2 <br />" <br />1' <br /> <br />- <br /> <br />6 <br />" <br />4" <br />3' <br /> <br />- <br /> <br />0 <br />" <br />PL1 <br />PL1 <br />P1 <br />S1 <br />1' - 3" <br />A9-2.1 <br />8 <br />A9-2.1 <br />7 <br />A9-2.1 <br />4 <br />SN.01 <br />E-2 <br />E-3 <br />3' <br /> <br />- <br /> <br />2 <br />" <br />1' <br /> <br />- <br /> <br />6 <br />" <br />4" <br />2' <br /> <br />- <br /> <br />8 <br />" <br />4" <br />1' - 0 1/2"9"F.P1' - 5" <br />VERIFY <br />2' - 6" <br />F.P1' - 5" <br />VERIFY <br />2' - 6" <br />2 EQ. <br />1' - 8"1' - 0" <br />S1 <br />PL1 <br />PL1 <br />A9-2.1 <br />8 <br />A9-2.1 <br />7 <br />A9-2.1 <br />4 <br />SN.01 <br />E-4 <br />4" <br />2' <br /> <br />- <br /> <br />8 <br />" <br />4" <br />1' <br /> <br />- <br /> <br />6 <br />" <br />3' <br /> <br />- <br /> <br />2 <br />" <br />2 EQ. <br />2' - 6"1' - 0" <br />1' - 6" <br />1' - 1 1/2"VERIFY <br />3' - 2" <br />AL <br />I <br />G <br />N <br />S1 <br />PL1 <br />PL1 <br />P1 <br />1" <br />3' <br /> <br />- <br /> <br />1 <br />1 <br />" <br />4" <br />3' <br /> <br />- <br /> <br />0 <br />" <br />2" <br />SN.03 <br />2' - 0" <br />R-5 <br />R-7 <br />P1 <br />SN.04 <br />G <br />R-2 <br />A <br />A9-2.1 <br />1 <br />L3 <br />P1 <br />S1 <br />F.P <br />2 EQ. <br />2' - 11" <br />PL1 <br />3' <br /> <br />- <br /> <br />0 <br />" <br />4" <br />3' <br /> <br />- <br /> <br />1 <br />1 <br />" <br />3" <br />EQ EQ <br />2' - 4" <br />SN.052' - 6" <br />T4 <br />2' <br /> <br />- <br /> <br />8 <br />" <br />SN.01 <br />A5-1.22D 2A <br />2B <br />003 <br />2' <br /> <br />- <br /> <br />0 <br />" <br />6' <br /> <br />- <br /> <br />3 <br />" <br />B <br />B <br />C <br />BATHROOM <br />UNIT 102 <br />101 <br />1' - 6"1' - 6" <br />1' - 6" <br />6' <br /> <br />- <br /> <br />7 <br /> <br />3 <br />/ <br />4 <br />" <br />R-3 <br />4' <br /> <br />- <br /> <br />1 <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br />A5-1.22D <br />A5-1.21A <br />1B <br />1C <br />003 <br />004 <br />3' - 2"2' - 0"2' - 6" <br />2' - 0"1' - 8"2' - 6"1' - 6"3' - 2 1/2" <br />B <br />B <br />B <br />B <br />F <br />KITCHEN <br />UNIT 102 <br />101 <br />11' - 4" <br />9' <br /> <br />- <br /> <br />4 <br /> <br />3 <br />/ <br />4 <br />" <br />2' <br /> <br />- <br /> <br />0 <br />" <br />1' <br /> <br />- <br /> <br />3 <br /> <br />1 <br />/ <br />4 <br />" <br />2' <br /> <br />- <br /> <br />9 <br />" <br />1' <br /> <br />- <br /> <br />3 <br /> <br />1 <br />/ <br />4 <br />" <br />2' <br /> <br />- <br /> <br />0 <br />" <br />E-1 <br />E-4 <br />E-3 <br />E-2 <br />INDICATES HEIGHT OF CEILING ABOVE FINISH FLOOR <br />GYPSUM BOARD CEILING <br />X'-X" <br />CEILING LIGHT FIXTURES <br />CEILING FAN <br />(E) 1 HR FIRE RATED WALL <br />WINDOW OR LOUVER REFERENCE <br />EA <br />X <br />Window Covering Reference <br />H=Horizontal Blinds <br />V=Vertical Blinds <br />D=Darkening Drapes <br />LS=Light Proof Shades <br />DOOR REFERENCE <br />WOOD STUD WALL <br />MILLWORK, SEE MILLWORK DETAILS <br />DOOR TAG SEE (add in view ref.) <br />AT PLAM SURFACE: PROVIDE TOP MOUNT SINK <br />AT SOLID SURFACE: PROVIDE UNDER-MOUNT SINK <br />SINK: <br />0000A <br />(TYPICAL WALL TYPE A UNLESS OTHERWISE NOTED) SEE <br />WALL REFERENCE <br />(add in view ref.) <br />A 6" <br />6'-0" <br />STUD SIZE <br />LOW PARTITION HEIGHT (WHERE OCCURS) <br />WALL TYPE <br />A <br />ACOUSTIC BATT INSULATION <br />6' - 2 1/2" <br />T4 SN.05 <br />5' - 0" <br />5' <br /> <br />- <br /> <br />0 <br />" <br />Renewal Date <br />LICENSED ARCHITECT <br />STATE OF C A L I FORNI <br />AEXP. 05/31/25 <br />J <br />C32284 <br />HOSHUAJAMESSMIT <br />WD PROJ. # DRAWN BY: CHECKED DATE <br />WESTGROUP DESIGNS, INC.© <br />ISSUED FOR: <br />REGISTRATION/SIGNATURE: <br />SHEET TITLE: <br />SHEET NUMBER: <br />REVISIONS: <br />23411 Yas Josh <br />UNIT 102 ENLARGED <br />PLANS AND <br />ELEVATIONS <br />A5-1.2 <br />PLAN CHECK -10/23/2023 <br />2/18/25 <br />BEWLEY STREET <br />RESIDENCE <br />ILLUMINATION <br />FOUNDATION <br />914, 916, 918 N BEWLEY <br />STREET <br />SANTA ANA, CA 92703 <br />LEGEND <br />SHEET KEYNOTES SN.## <br />SN# DESCRIPTION <br />SN.01 PROVIDE 2x8 BACKING FOR FUTURE GRAB BAR PER R327.1.1 <br />SN.02 36" X36" ONE -PIECE ACRLIC SHOWER W/ IN PLACE BACKING <br />SN.03 (N) LIGHTING FIXTURE <br />1/4" = 1'-0" <br />UNIT 102 ENLARGED FLOOR PLAN 1 <br />1/4" = 1'-0" <br />UNIT 102 REFLECTED CEILING PLAN 2 <br />1/4" = 1'-0" <br />1A <br />1/4" = 1'-0" <br />1B <br />1/4" = 1'-0" <br />1C <br />1/4" = 1'-0" <br />2A <br />1/4" = 1'-0" <br />2B <br />1/4" = 1'-0" <br />2C <br />1/4" = 1'-0" <br />1D <br />FINISH SCHEDULE <br />TAG ITEM MANUFACTURER SPEC SIZE COLOR INSTALLATION NOTES CONTACT <br />B1 WALL BASE BY CONTRACTOR PAINT-GRADE FLAT STOCK MDF 4"H PAINT TO MATCH P1 - <varies> <varies> <br />C1 CARPET <varies> <varies> <varies> <varies> - - - <br />P1 PAINT SHERWIN WILLIAMS INTERIOR LATEX PAINT - SW7636 ORIGAMI WHITE - 1,2 ROCKY BERLANGA rocky.m.berlanga@sherwin.com <br />P2 PAINT DUNN EDWARDS INTERIOR LATEX PAINT - DEW380 WARM WHITE - 1,3 KIM HAMPTON kim.hampton@dunnedwards.com <br />P3 EXTERIOR PAINT DUNN EDWARDS ACRI-HUES EXTERIOR (ACHS10) - DE6213 FINE GRAIN - 1,4 KIM HAMPTON kim.hampton@dunnedwards.com <br />PL1 PLASTIC LAMINATE BY OWNER - - - - - <varies> <br />RF1 LUXURY VINYL TILE <varies> <varies> TBD. <varies> STAGGER - - <br />S1 QUARTZ PENTAL QUARTZ QUARTZ 65"X130" BQ8815P MISTERIO POLISHED - - KIM CLAYBORNE kim.clayborne@arcsurfaces.com <br />T1 PORCELAIN TILE BY OWNER - - - - - <br />T2 EXTERIO PORCELAIN TILE BY OWNER - - - - - <br />T3 EXTERIOR PAINT DUNN EDWARDS ACRI-HUES EXTERIOR (ACHS10) - DE6213 FINE GRAIN - 1,4 KIM HAMPTON kim.hampton@dunnedwards.com <br />T4 WALL TILE BY OWNER - - - - - <br />RESTROOM ACCESSORY SCHEDULE <br />TAG MANUFACTURER MODEL DESCRIPTION <br />A KOHLER BY OWNER WHITE ELONGATED TOILET <br />B KOHLER BY OWNER WHITE ELONGATED TOILET <br />C KOHLER BY OWNER LEVEL TOILET PAPER HOLDER <br />D KOHLER BY OWNER TOWEL BAR <br />E KOHLER BY OWNER TOWEL HOOK RACK <br />F KOHLER BY OWNER OVAL CERAMIC SINK <br />G BY OWNER BY OWNER 2'4" x 3'6" FRAMELESS MIRROR <br />H BY OWNER BY OWNER FRAMELESS RECESSED BATHROOM MEDICINE CABINET <br />WITH MIRROR <br />I BY OWNER BY OWNER 2'4" x 3'0" FRAMELESS MIRROR <br />EQUIPMENT SCHEDULE <br />TAG DESCRIPTION MANUFACTURER PRODUCT NUMBER <br />E-1 FRONT LOAD WASHER / DRYER BY OWNER BY OWNER <br />E-2 RANGE BY OWNER BY OWNER <br />E-3 RANGE HOOD BY OWNER BY OWNER <br />E-4 REFRIDGERATOR BY OWNER BY OWNER <br />FINISH SCHEDULE NOTES <br />1. PRIOR TO FABRICATION PROVIDE DRAW DOWN FOR ARCHITECTS REVIEW AND APPROVAL. <br />2. PROVIDE 2 COATS, SEMI-GLOSS FINISH AT ALL RESTROOMS, JANITOR CLOSETS, AND <br />WASHER/DRYER CLOSETS. FOR ALL OTHER LOCATIONS, PROVIDE 2 COATS, EGGSHELL FINISH. <br />3. AT CEILINGS AND SOFFITS, PROVIDE 2 COATS, FLAT FINISH. <br />4. AT EXTERIOR WALLS, PROVIDE 2 COATS, FLAT FINISH, IN LAYOUT AS SHOWN IN ELEVATIONS. <br />5. GROUT SIZE AS INDICATED ON FINISH SCHEDULE, GROUT COLOR TO BE SELECTED BY ARCHITECT <br />FROM MFR'S STANDARD COLORS. BASIS OF DESIGN: CUSTOM BUILDING PRODUCTS PRISM ULTIMATE <br />PERFORMACE GROUT, OR EQUAL. <br />6. INSTALL AT ALL EXPOSED SURFACES. <br />7. MITER ALL INTERIOR AND EXTERIOR CORNERS. <br />8. WOOD GRAINS TO RUN VERTICAL. <br />9. ADHERE TO SUBSTRATE PER MANUFACTURER'S RECOMMENDED ADHESIVE. <br />10. INSTALL AS SHOWN IN EXTERIOR ELEVATIONS. <br />2 PLAN CHECK CORRECTIONS 03/14/2025 <br />3 PLAN CHECK CORRECTIONS 04/09/2025 <br />1/4" = 1'-0" <br />2D <br />GENERAL NOTES <br />BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT SHALL BE CONTINUOUS ON EACH END <br />OF THE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK WALL REINFORCEMENT FOR A LOWER GRAB <br />BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE LOCATED NO MORE THAN 6 INCHES ABOVE THE <br />BATHTUB RIM <br />ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS INTENDED TO BE USED BY OCCUPANTS <br />SHALL BE LOCATED NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE OUTLET BOX AND NOT <br />LESS THAN 15 INCHES MEASURED FROM THE BOTTOM OF THE OUTLET BOX ABOVE THE FINISH FLOOR <br />UNLESS EXCEPTION MET. (R327.1.2) <br />INTERIOR DOOR WIDTH (AT LEAST ONE BEDROOM DOOR AND ONE BATHROOM DOOR WITH 32" CLEAR <br />OPENING), EFFECTIVE JULY 1, 2024 (R327.1.3) <br />DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL NOT EXCEED 48 INCHES ABOVE EXTERIOR <br />FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON ASSEMBLY. WHERE <br />DOORBELL HEIGHT REQUIREMENT CANNOT BE MET FOR INTEGRATED DOORBELL FEATURES, A <br />STANDARD DOORBELL BUTTON OR CONTROL SHALL ALSO BE PROVIDED AT A HEIGHT NOT EXCEEDING 48 <br />INCHES ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON <br />OR CONTROL. (R327.1.4) <br />3 <br />PLAN CHECK - 04/09/2025 <br />4/09/25 <br />914-918 N Bewley <br />St5/8/2025