My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
914-918 N Bewley St - REV 1 - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Bewley St
>
918 N Bewley St
>
914-918 N Bewley St - REV 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 10:50:54 AM
Creation date
2/24/2026 10:50:27 AM
Metadata
Fields
Template:
Plan
Permit Number
20182346
30147017
40138922
101118570
101118571
101118573
101124002
Full Address
918 N Bewley St
914 N Bewley St
916 N Bewley St
Street Number
918
Street Direction
N
Street Name
Bewley
Street Suffix
St
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
270
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SOLID WOODWD <br />PAINT*PT <br />FINISH <br />MATERIAL <br />* CONFIRM COLOR SELECTION WITH ARCHITECT, PROVIDE FINISH SAMPLES FOR REVIEW. <br />A <br />TY <br />P <br />. <br /> <br />A <br />L <br />L <br /> <br />D <br />O <br />O <br />R <br />S <br />10 <br />" <br /> <br />C <br />L <br />R <br />. <br /> <br />M <br />I <br />N <br />. <br />B C <br />D <br />7' <br /> <br />- <br /> <br />0 <br />" <br />3' - 0" <br />13 <br />A6-1.1 <br />10 <br />A6-1.1 <br />14 <br />A6-1.1 <br />9 <br />A6-1.1 <br />9 <br />A6-1.1 <br />9 <br />A6-1.1 <br />14 <br />A6-1.1 <br />DOOR FRAME PER <br />DOOR SCHEDULE <br />SCHEDULED DOOR <br />WALL FRAMING PER <br />STRUCTURAL <br />PE <br />R <br /> <br />P <br />L <br />A <br />N <br />WA <br />L <br />L <br /> <br />T <br />Y <br />P <br />E <br />CEILING WHERE OCCURS <br />ALUMINUM DOOR FRAME <br />DOOR PER SCHEDULE <br />PER PLAN <br />WALL TYPE <br />HEADER PER STRUCTURAL <br />1/ <br />4 <br />" <br /> <br />M <br />A <br />X <br />. <br />1 <br />2 <br />1 <br />2 <br />1/ <br />2 <br />" <br /> <br />M <br />A <br />X <br />. <br />.. <br />1/ <br />4 <br />" <br /> <br />M <br />A <br />X <br /> 1 <br />/ <br />4 <br />" <br /> <br />M <br />A <br />X <br />10 <br />" <br />MI <br />N <br />JAMB BEYOND <br />DOOR PER SCHEDULE <br />ALUMINUM <br />THRESHOLD <br />ALUMINUM <br />THRESHOLD SET <br />IN FULL BED OF <br />MASTIC <br />TREX DECKING <br />TYP. AT ALL <br />DOOR THRESHOLDS <br />JAMB BEYOND <br />DOOR PER SCHEDULE <br />FLOOR FINISH MATERIAL TRANSITION <br />FLOOR FINISH <br />RESILIENT <br />TRANSITION STRIP <br />CL <br />01 - PASSAGE LATCHSET <br />QTY.ITEM <br />3 EA. BUTT HINGE <br />1 EA. PASSAGE LATCHSET <br />1 EA. SURFACE CLOSER <br />1 EA. FLOOR STOP <br />NOTE:SEE DOOR NOTES AND DOOR CODE COMPLIANCE NOTES FOR ADDITIONAL INFORMATION. <br />HARDWARE FINISH COLOR BASIS OF DESIGN:STAINLESS STEEL - BRUSHED #4 <br />3 EA. DOOR SILENCER <br />HARDWARE MANUFACTURER BASIS OF DESIGN:SCHLAGE <br />LATCHBOLT RETRACTED BY LEVER FROM EITHER SIDE AT ALL TIMES. <br />03 - PRIVACY LOCKSET <br />QTY. ITEM <br />3 EA. BUTT HINGE <br />1 EA. SURFACE CLOSER <br />1 EA. FLOOR STOP <br />3 EA. DOOR SILENCER <br />LATCHBOLT RETRACTED BY LEVER FROM EITHER SIDE UNLESS <br />SECURED FROM EXTERIOR WITH INTERIOR THUMBTURN. <br />TURNING INSIDE LEVER OR CLOSING DOOR UNLOCKS, UNLOCK FROM <br />EXTERIOR BY EMERGENCY ACCESS HOLE. <br />1 EA. PRIVACY LOCKSET <br />1 SET SOUND SEALS <br />02 - UNIT LOCKSET <br />QTY. ITEM <br />3 EA. BUTT HINGE <br />1 EA. INTERCHANGEABLE CORE CYLINDER <br />1 EA. SURFACE CLOSER <br />1 EA. FLOOR STOP <br />INTERCONNECTED LOCK WITH LEVER SET AND DEADBOLT. <br />UNRESTRICTED EGRESS FROM INSIDE IN THE DIRECTION OF EGRESS. <br />LATCHBOLT RETRACTED FROM EITHER SIDE UNLESS DEADBOLT IS <br />SECURED FROM INSIDE WITH INTERIOR THUMB TURN. DEADBOLT CAN <br />BE SECURED OR RETRACTED BY KEY FROM OUTSIDE. <br />1 EA. INTERCONNECTED DEADBOLT LOCK <br />1 EA. DOOR SILENCER <br />1 EA. SMOKE SEALS <br />Renewal Date <br />LICENSED ARCHITECT <br />STATE OF C A L I FORNI <br />AEXP. 05/31/25 <br />J <br />C32284 <br />HOSHUAJAMESSMIT <br />WD PROJ. # DRAWN BY: CHECKED DATE <br />WESTGROUP DESIGNS, INC.© <br />ISSUED FOR: <br />REGISTRATION/SIGNATURE: <br />SHEET TITLE: <br />SHEET NUMBER: <br />REVISIONS: <br />23411 Yas Josh <br />DOOR SCHEDULE <br />AND DETAILS <br />A6-1.1 <br />PLAN CHECK -10/23/2023 <br />2/18/25 <br />BEWLEY STREET <br />RESIDENCE <br />ILLUMINATION <br />FOUNDATION <br />914, 916, 918 N BEWLEY <br />STREET <br />SANTA ANA, CA 92703 <br />TYPICAL UNIT DOOR SCHEDULE <br />ID ROOM NAME TYPE <br />HW <br />GROUP <br />DOOR FRAME RATING <br />(MIN.) <br />PANIC <br />HW NOTESWIDTH HEIGHT THK MATERIAL FINISH MATERIAL FINISH JAMB HEAD SILL <br />000 STORAGE B - 2' - 8" 6' - 8" 0' - 1 1/2" <br />001 UNIT ENTRY A 02 3' - 0" 7' - 0" 0' - 1 3/4" WD PT WD PT 10/A6-1.1 9/A6-1.1 13/A6-1.1 <br />002 BEDROOM B 03 2' - 8" 6' - 8" 0' - 1 1/2" WD PT WD PT 10/A6-1.1 9/A6-1.1 14/A6-1.1 <br />003 BATHROOM B 03 2' - 8" 6' - 8" 0' - 1 1/2" WD PT WD PT 10/A6-1.1 9/A6-1.1 14/A6-1.1 <br />004 WASHER/DRYER C 01 2' - 0" 6' - 8" 0' - 1 1/2" WD PT WD PT 10/A6-1.1 9/A6-1.1 14/A6-1.1 <br />005 CLOSET C 02 2' - 0" 6' - 8" 0' - 1 1/2" WD PT WD PT 10/A6-1.1 9/A6-1.1 14/A6-1.1 <br />006 BATHROOM Q 03 2' - 8" 6' - 8" 0' - 1 1/2" WD PT WD PT 10/A6-1.1 9/A6-1.1 14/A6-1.1 <br />007 WASHER/DRYER D - 4' - 6" 6' - 8" 0' - 1 1/2" WD PT WD PT -- - <br />DOOR NOTES <br />LEGEND <br />DOOR CODE COMPLIANCE NOTES <br />1. ALL RATED DOORS TO BE POSITIVE LATCHING AND SELF-CLOSING. <br />2. FIRE DOOR ASSEMBLIES SHALL BE LABELED IN ACCORDANCE WITH THE CBC. <br />3. FIRE DOORS SHALL HAVE AN APPROVED LABEL OR LISTING MARK INDICATING THE FIRE <br />PROTECTION RATING WHICH IS PERMANENTLY AFFIXED AT THE FACTORY WHERE FABRICATION <br />AND ASSEMBLY ARE DONE. <br />4. ALL FIRE RATED ASSEMBLIES ARE TO BE PROVIDED WITH AN APPROVED SMOKE GASKET. INSTALL <br />TO PROVIDE A CONTINUOUS SEAL WHERE THE DOOR MEETS THE STOP ON THE HEAD AND BOTH <br />JAMBS. <br />5. EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL <br />KNOWLEDGE OR EFFORT. <br />6. FIRE RATED DOOR FRAMES SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S <br />INSTRUCTIONS. MANUFACTURER'S INSTRUCTIONS SHALL BE MADE AVAILABLE TO INSPECTING <br />AUTHORITIES. <br />7. INSTALL FLOOR STOPS IN LOCATION NOT TO CAUSE TRIPPING HAZARD IN PATH OF TRAVEL, 4" MAX <br />FROM WALL. <br />8. DOOR AND GATE OPENING FORCE: THE FORCE REQUIRED FOR PUSHING OR PULLING OPEN A <br />DOOR OR GATE SHALL BE A MAXIMUM 5 LBS. FOR HINGED DOORS, SLIDING AND FOLDING DOORS. <br />9. OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT <br />GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE <br />OPEARABLE PARTS SHALL BE 5 LBS. MAXIMUM. <br />10. THE BOTTOM 10" OF ALL DOORS TO HAVE SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE <br />DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS <br />CONDITION. <br />11. DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR <br />ANY SPECIAL KNOWLEDGE OR EFFORT. <br />12. FLOOR OR GROUND SURFACE WITHIN THE REQUIRED MANEUVERING CLEARANCES PER DETAIL <br />7/G-1.1, SHALL NOT HAVE A VERTICAL CHANGE IN LEVEL GREATER THAN 1/4" HIGH WITHOUT EDGE <br />TREATMENT. <br />HARDWARE GROUPS <br />DOOR TYPES <br />3" = 1'-0" <br />DOOR JAMB 10 <br />3" = 1'-0" <br />DOOR HEAD 9 <br />3" = 1'-0" <br />EXTERIOR DOOR SILL 13 <br />3" = 1'-0" <br />DOOR SILL 14 <br />1. THE HARDWARE SCHEDULE IS INTENDED TO COVER ALL DOORS IN THE PROJECT AND ESTABLISH A <br />TYPE AND STANDARD OF QUALITY. FURNISH AND INSTALL A COMPLETE AND OPERATIONAL SYSTEM <br />OF DOOR FINISH HARDWARE ITEMS ENCOMPASSING ALL OPENINGS WITHIN THE PROJECT AREA AS <br />REQUIRED TO MEET CODE AND FUNCTIONAL REQUIREMENTS. THE HARDWARE SPECIFICATION IS <br />PROVIDED AS A BASIS FOR A COMPLETE HARDWARE SUBMITTAL WHICH INDICATES THE QUANTITY, <br />TYPE, NUMBER, MANUFACTURER, AND LOCATION OF EACH ARTICLE OF HARDWARE REQUIRED. <br />HARDWARE LIST SHALL BE SUBMITTED NO LATER THAN 30 DAYS BEFORE THE ORDER DATE <br />NECESSARY TO MEET THE PROJECT SCHEDULE. REVIEW OF THE HARDWARE LIST DOES NOT <br />REPRESENT CERTIFICATION THAT THE LIST IS COMPLETE AND DOES NOT RELIEVE THE CONTRACTOR <br />FROM PROVIDING A COMPLETE PROJECT. <br />2. CLOSET DOORS, RESTROOM DOORS, ETC. IN THE ONE-HOUR CORRIDOR ARE 20 MINUTE RATED <br />DOORS. ALL HARDWARE IN RATED DOORS MUST MAINTAIN DOOR FIRE RATING AND GASKETING MUST <br />BE PROVIDED. <br />3. COORDINATE HARDWARE QUANTITIES WITH DOUBLE DOORS WHERE OCCURS AND PROVIDE <br />ADDITIONAL HARDWARE AS NEEDED. <br />4. DOOR HARDWARE MANUFACTURE AND FINISH TO MATCH BUILDING STANDARDS WHERE APPLICABLE. <br />5. ALL CORRIDOR DOOR ASSEMBLIES TO HAVE FINISH TO MATCH BUILDING STANDARD. <br />6. ALL LOCKSETS SHALL BE CODED AND/OR KEYED IN ACCORDANCE WITH OWNER'S REQUIREMENTS. <br />CODES AND/OR KEYS ARE TO BE DELIVERED TO OWNER PROPERLY TESTED AND/OR TAGGED. THE <br />NUMBER OF KEYS TO BE COORDINATED WITH OWNER. <br />7. HARDWARE SUPPLIER SHALL PROVIDE GRANDMASTER KEY, MASTER KEY, KEY-ALIKE AND/OR KEY- <br />DIFFERENT ALL LOCKS IN ACCORDANCE WITH KEYING SCHEDULE AS PROVIDE BY OWNER. <br />8. ALL HARDWARE SHALL BE OF LEVER TYPE TO COMPLY WITH ACCESSIBILITY REQUIREMENTS. <br />REPLACE ALL DOOR HARDWARE ITEMS NOT IN COMPLIANCE WITH APPLICABLE ACCESSIBILITY <br />REQUIREMENTS TO THE SATISFACTION OF THE BUILDING AUTHORITY. <br />9. DOOR OPENINGS IN PARTITIONS NOT DIMENSIONED SHALL BE 4”FROM ADJOINING PARTITION. <br />10. VERIFY AND COORDINATE THE THICKNESS OF FLOOR FINISH WITH UNDERCUT DIMENSION AT DOOR. <br />11. EACH ARTICLE OF HARDWARE SHALL BE INDIVIDUALLY PACKAGED IN ITS ORIGINAL MANUFACTURER'S <br />CONTAINER AND PROPERLY LABELED IN CONFORMANCE WITH THE APPROVED HARDWARE LIST. <br />12. FURNISH (3) BUTT HINGES FOR DOORS UP TO 7'-0' HIGH AND (1) HINGE FOR EACH ADDITIONAL 2'-6". <br />13. PROVIDE STANDARD STRIKE PLATE WITH EXTENDED LIP WHERE REQUIRED TO PROTECT TRIM FROM <br />BEING MARRED OR DAMAGED BY THE LATCH BOLT. <br />14. PROVIDE DUST COVERS AT ALL STRIKE PLATES. <br />15. DOORS SHALL BE INSTALLED IN FRAME WITH 1/8" MAX. TOLERANCE AT HEAD HINGES, AND <br />STRIKE/JAMB. <br />16. ALL EXTERIOR AND RESTROOM DOORS ARE TO BE SELF-CLOSING. PROVIDE GASKETING AND DOOR <br />SWEEP AT ALL COMMON DOORS. <br />17. ALL DOOR LOCKSETS/LATCHSETS TO BE MORTISE STYLE WITH MODERN LEVER, U.N.O. ALL LEVER <br />ACCESS FROM THE INTERIOR SHALL ALWAYS BE FREE TO PROVIDE IMMEDIATE EGRESS AND SHALL <br />UNLATCH WITH ONE OPERATION. <br />18. ALL NEW HARDWARE ON DOORS TO HAVE SIMILAR FINISHES U.N.O., ALL FASTENERS SHALL MATCH <br />THE HARDWARE MATERIAL AND FINISH. <br />19. DOOR WOOD VENEER QUALITY, SHEEN, AND STAIN FINISH ARE TO BE CONFIRMED BY THE <br />ARCHITECT. <br />ADU SCHEDULE <br />ID ROOM NAME TYPE <br />HW <br />GROU <br />P <br />DOOR FRAME <br />RATING <br />(MIN.) <br />PANIC <br />HW NOTESWIDTH HEIGHT THK MATERIAL FINISH <br />MATERIA <br />L FINISH JAMB HEAD SILL <br />021 K 3' - 0" 6' - 8" 0' - 1 3/4" <br />022 K 3' - 0" 6' - 8" 0' - 1 3/4" <br />023 K 3' - 0" 6' - 8" 0' - 1 3/4" <br />025 K 3' - 0" 6' - 8" 0' - 1 3/4" <br />028 S 8' - 0" 10' - 0" 0' - 1 3/4" <br />FO <br />R <br /> <br />C <br />O <br />N <br />S <br />T <br />R <br />U <br />C <br />T <br />I <br />O <br />N <br />03/24/25 <br />914-918 N Bewley <br />St5/8/2025
The URL can be used to link to this page
Your browser does not support the video tag.