My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3430 S Sheffield Rd - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Sheffield Rd
>
3430 S Sheffield Rd
>
3430 S Sheffield Rd - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 11:05:50 AM
Creation date
2/24/2026 11:05:47 AM
Metadata
Fields
Template:
Plan
Permit Number
20187734
Full Address
3430 S Sheffield Rd
Street Number
3430
Street Direction
S
Street Name
Sheffield
Street Suffix
Rd
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CONDUIT SCHEDULE <br />TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT <br />1 Inverter Input (2) 10 AWG (PV WIRE)N/A 6 AWG (BARE)Open Air <br />2 Inverter Input (4) 10 AWG <br />THHN/THWN-2 N/A 8 AWG THHN/THWN-2 3/4 EMT <br />3 Inverter Output (2) 6 AWG <br />THHN/THWN-2 <br />(1) 6 AWG <br />THHN/THWN-2 8 AWG THHN/THWN-2 3/4 EMT <br />4 Backup Panel Feeder (2) 1 AWG <br />THHN/THWN-2 <br />(1) 1 AWG <br />THHN/THWN-2 6 AWG THHN/THWN-2 1 1/4 EMT <br />5 Gateway Feeder (2) 1 AWG <br />THHN/THWN-2 <br />(1) 1 AWG <br />THHN/THWN-2 6 AWG THHN/THWN-2 1 1/4 EMT <br />6 BackUp Loads <br />(2) 12 AWG <br />THHN/THWN-2 <br />(2) 12 AWG <br />THHN/THWN-2 8 AWG THHN/THWN-2 <br />2-1/2EMT <br />(17) 10 AWG <br />THHN/THWN-2 <br />(17) 10 AWG <br />THHN/THWN-2 8 AWG THHN/THWN-2 <br />(6) 8 AWG <br />THHN/THWN-2 <br />(3) 8 AWG <br />THHN/THWN-2 8 AWG THHN/THWN-2 <br />(2) 4 AWG <br />THHN/THWN-2 <br />(1) 4 AWG <br />THHN/THWN-2 8 AWG THHN/THWN-2 <br />INSTALLER MUST CHECK THE CONDITION, <br />INSTALLABILITY AND CODE COMPLIANCE OF <br />EXISTING EQUIPMENT. <br />General Notes: <br />• CITY REQUIRES TWO SOURCES OF GROUND - UFER, TWO GROUNDS RODS OR <br />COLD WATER GAS BOND <br />• INSTALL THE BACKED UP LOAD CONDUCTORS AND THE MICROGRID <br />INTERCONNECTION DEVICE BREAKER CONDUCTORS IN TWO SEPARATE <br />CONDUITS. <br />PAGE <br />REV: B 2/18/2026 <br />SUSAN GARCIA <br />3430 S SHEFFIELD RD, SANTA <br />ANA, CA, 92704 <br />PROJECT NUMBER: <br /> 109R-430GARC2 PR-3004702971 <br />SHEET <br />DESIGNER: <br />ASHIK <br />CUSTOMER RESIDENCE: <br />TEL. (714) 421-8080 <br />APN: 412-531-77 <br />(415) 580-6920 ex3 <br />PV-4.1 <br />#ESTAMP#SSTAMP <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />ELECTRICAL CONT. <br />MODULE CHARACTERISTICS <br />SILFAB: SIL-440QD 440 W <br />OPEN CIRCUIT VOLTAGE 38.97 V <br />MAX POWER VOLTAGE 33.41 V <br />SHORT CIRCUIT CURRENT 14.29 A <br />IF THE RELOCATED LOADS EXTEND MORE THAN 6 FEET, AFCI PROTECTION APPLIES PER 2025 CEC 210.12 <br />ANY MULTIWIRE BRANCH CIRCUITS RELOCATED ARE TO BE IDENTIFIED, GROUPED, AND EQUIPPED WITH A <br />2-POLE OCPD BREAKER PER CEC 210.4(B,D).
The URL can be used to link to this page
Your browser does not support the video tag.