Laserfiche WebLink
2 <br />W.I CLOSET <br />UP <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br /> <br /> <br />5 <br />3 <br />. <br />2 <br />6 <br />' <br />PROPERTY LINE 114.08' <br />4' <br /> <br />A <br />D <br />U <br /> <br />R <br />E <br />A <br />R <br /> <br />S <br />E <br />T <br />B <br />A <br />C <br />K <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />31 <br />0 <br />9 <br /> <br />S <br />. <br /> <br />A <br />r <br />t <br />e <br />s <br />i <br />a <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />PROPERTY LINE 111.99' <br />4' ADU SIDE SETBACK <br />4' ADU SIDE SETBACK <br />EXIST. WATER LINE <br />OF MAIN HOUSE <br />EXIST. SEWER LATERAL <br />OF MAIN HOUSE <br />REF. <br />TV <br />TV <br />TV <br />W.I CLOSET <br />UP <br />ADU WATER LINE CONNECTED TO EXISTING <br />1" WATER LINE AT THE FRONT YARD <br />10' x 20' PARKING <br />SPACE FOR ADU <br />SEWER LINE TO TIE TO 4" LINE AT FRONT <br />YARD . MINIMUM SLOPE 1 <br />4"/12". <br />200 AMP <br />ELECTRICAL UNDERGROUND CONNECTION <br />FROM MAIN HOUSE TO ADU <br />19'-9" <br />4'-0"17'-9" <br />4' <br />- <br />0 <br />" <br />45 <br />' <br />- <br />3 <br />" <br />4' <br />- <br />0 <br />" <br />4'-0"17'-9" <br />12 <br />' <br />- <br />9 <br />" <br />14 <br />' <br />- <br />1 <br />" <br />18 <br />' <br />- <br />5 <br />" <br />15'-0"4'-9" <br />20 <br />22A <br />16 <br />TRASH AREA <br />TRASH AREA <br />FOR ADU <br />21 <br />19 <br />17 <br />: 1,586 SQ. FT. <br />ADU : 800 SQ.FT <br />88 SQ.FT <br />L1 <br />L2 <br />13 <br />25 <br />19'-9" <br />21'-6" <br />EXIST. <br />20'-1" <br />EXIST. <br />48 SQ. FT. <br />23 <br />1 <br />A12.00 <br />26 <br />7 <br />A12.00 <br />8 <br />A12.00 <br />8 <br />A12.00 <br />11 <br />22B 19 <br />14 <br />1 <br />A12.00 <br />1 <br />A12.00 <br />1 <br />W.I CLOSET <br />UP <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br /> <br /> <br />5 <br />3 <br />. <br />2 <br />6 <br />' <br />PROPERTY LINE 114.08' <br />4' <br /> <br />A <br />D <br />U <br /> <br />R <br />E <br />A <br />R <br /> <br />S <br />E <br />T <br />B <br />A <br />C <br />K <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />31 <br />0 <br />9 <br /> <br />S <br />. <br /> <br />A <br />r <br />t <br />e <br />s <br />i <br />a <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />PROPERTY LINE 111.99' <br />4' ADU SIDE SETBACK <br />4' ADU SIDE SETBACK <br />EXIST. WATER LINE <br />OF MAIN HOUSE <br />EXIST. SEWER LATERAL <br />OF MAIN HOUSE <br />1 <br />2 <br />3 <br />11 <br />4 <br />9 <br />10 <br />6 <br />7 <br />7 <br />7 <br />5 <br />8 <br />15 <br />2 <br />18 <br />944 SQ. FT. <br />514 SQ. FT. <br />128 SQ. FT. <br />15 24 <br />2 <br />310 SQ. FT. <br />48 SQ. FT. <br />EXISTING LANDSCAPE. <br />EXISTING CONCRETE DRIVEWAY.1 <br />2 <br />4 EXISTING CONCRETE PAVEMENT. <br />5 <br />6 <br />A.COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES <br />AND REGULATIONS PERTAINING TO SAFETY OF PERSONS, <br />PROPERTY AND ENVIRONMENTAL PROTECTION. <br />B.ALL SETBACKS ARE MEASURED FROM PROPERTY LINE TO FACE <br />OF BUILDING FINISH. <br />C.FIELD VERIFY EXISTING CONDITIONS AND ELEVATIONS. IF ANY <br />DISCREPANCIES ARE ENCOUNTERED, NOTIFY PROJECT <br />ENGINEER TEAM PRIOR TO PROCEEDING WITH CONSTRUCTION. <br />D.MAINTAIN MINIMUM OF 2% SLOPE AWAY FROM THE STRUCTURE. <br />E.VERIFY LOCATION OF EXISTING UTILITIES PRIOR TO <br />COMMENCEMENT OF ANY WORK. <br />F.VERIFY LOCATION OF WATER METERS, ELECTRIC METERS AND <br />GAS METERS ARE IN ACCORDANCE WITH SERVICING UTILITY <br />COMPANY REQUIREMENTS PRIOR TO FIELD INSPECTORS TO <br />REVIEW AND APPROVE UNDERGROUND SERVICES <br />REQUIREMENTS PRIOR TO CONCRETE PLACEMENT. <br />EXISTING STREET SIDEWALK. <br />EXISTING HOUSE. <br />7 <br />8 <br />9 <br />EXISTING 6'H. BLOCK WALL TO REMAIN. <br />12 <br />3 EXISTING CONCRETE STREET CURB. <br />10 <br />EXISTING ELECTRICAL PANEL OF MAIN HOUSE TO BE <br />UPGRADED TO 200 AMP. <br />11 <br />EXISTING GAS METER LOCATION. <br />13 <br />EXISTING OVERHEAD POWER LINE. <br />AREA NOT IN CONTRACT <br />EXISTING PATIO TO BE DEMOLISHED. <br />EXISTING WATER METER LOCATION. <br />NEW CONCRETE PAVING. <br />15 <br />16 <br />GAS METER FOR ADU WITH 1 1 <br />4" GAS LINE. <br />17 NEW ADU. <br />14 <br />18 <br />NEW DETACHED ADU : 800 S.F. <br />EXISTING LANDSCAPING TO BE DEMOLISHED. <br />19 <br />20 <br />21 <br />22A <br />FRONT LANDSCAPING CALCULATION <br />20' FRONT SITE AREA <br />L1 153 SQ. FT. <br />1,068 SQ. FT. <br />50% PROVIDED <br />381 SQ. FT. <br />534 SQ. FT.TOTAL LANDSCAPING AREA <br />50% LANDSCAPING REQUIRED 534 SQ. FT.50% PROVIDED <br />NEW WATER HEATER WITHIN PLASTER ENCLOSURE WITH <br />DOOR. PAINTED TO MATCH ADU EXTERIOR WALL. <br />EXISTING STORAGE TO BE RELOCATED. <br />OUTDOOR AIR CONDITIONER UNIT FOR ADU. <br />NEW ELECTRICAL SUB-PANEL 200AMP FOR ADU UNDERGROUND <br />FEED FROM NEW ELECTRICAL METER AT MAIN HOUSE. <br />23 <br />L2 <br />24 EXISTING 6"H. WOOD FENCE TO BE DEMOLISHED. <br />25 <br />PROVIDE 1-HR FIRE RATED EXTERIOR WALL AND EAVE <br />PROJECTION . PREFER TO DETAIL 1/ A12.00 AND DETAIL 7/A12.00 . <br />26 <br />NEW 6"H. WOOD GATE. <br />1-HR FIRE RATED CONSTRUCTION. <br />NEW 400AMP ELECTRICAL DUAL METER PANEL: 200 SOCKET <br />FOR MAIN HOUSE & 200 SOCKET FOR ADU. <br />SERVICE DISCONNECTING FOR ADU SHALL BE INSTALLED <br />ADJACENT TO SUB-PANEL OUTSIDE OF BUILDING. [CEC 230.70] <br />NEW 200AMP PANEL FOR MAIN HOUSE. MINIMUM SIZE ADU SUB-PANEL <br />BUS BAR RATING SHALL BE 225AMP [2022 CEnC 150.0 (S)]. PROVIDE <br />MINIMUM 20 FEET UFER GROUND FOR NEW PANEL. <br />NEW 200AMP PANEL SUPPLYING ADU SHALL BE PROVIDED WITH <br />TYPE 1 OR TYPE 2 SURGE-PROTECTIVE DEVICE (CEC 230.67). <br />22B <br />DN. <br />(E)5:12 SLOPE <br />5:12 SLOPE <br />(E <br />) <br />3: <br />1 <br />2 <br /> <br />S <br />L <br />O <br />P <br />E <br />(E <br />) <br />3: <br />1 <br />2 <br /> <br />S <br />L <br />O <br />P <br />E <br />1:12 SLOPE <br />1B <br />672 SQ. FT. <br /> C <br />O <br />V <br />E <br />R <br />E <br />D <br /> <br />P <br />A <br />T <br />I <br />O <br /> <br />D <br />E <br />M <br />O <br />L <br />I <br />T <br />I <br />O <br />N <br />31 <br />0 <br />9 <br /> <br />S <br /> <br />A <br />r <br />t <br />e <br />s <br />i <br />a <br /> <br />S <br />t <br /> <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br /> <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />NE <br />W <br /> <br />D <br />E <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br />31 <br />0 <br />9 <br /> <br />S <br /> <br />A <br />r <br />t <br />e <br />s <br />i <br />a <br /> <br />S <br />t <br /> <br />U <br />n <br />i <br />t <br /> <br /># <br />2 <br /> <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br /> <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />11 <br />8 <br />8 <br />1 <br /> <br />s <br />t <br /> <br />r <br />a <br /> <br />a <br />r <br />e <br />n <br /> <br />r <br />e <br /> <br /> <br />C <br />A <br /> <br /> <br />9 <br />2 <br />8 <br />4 <br />0 <br /> <br /> <br /> <br /> <br /> <br />T <br />: <br /> <br />7 <br />1 <br />4 <br />. <br />6 <br />5 <br />1 <br />. <br />9 <br />9 <br />4 <br />5 <br /> <br /> <br /> <br />E <br />: <br /> <br />e <br />s <br />i <br />n <br />2 <br />i <br />a <br />. <br />2 <br />2 <br />2 <br />2 <br />2 <br />2