Laserfiche WebLink
1 ELECTRIC PLAN <br />1/4"=1'-0" <br />·ALL RECEPTACLES AT KITCHEN COUNTER TOP <br />SHALL BE AFCI & GFCI. <br />1.1 <br />AFCI <br />CR <br />GFCI <br />AFCI <br />R <br />+48" GFCI <br />+48" GFCI <br />H <br />WP <br />GFCIAFCI <br />AFCI <br />AFCI <br />GFCI <br />GFCI.240V <br />REF. <br />TV <br />TV <br />TV <br />AFCI <br />AFCI <br />GFCI +65 <br />GFCI <br />+48" GFCI <br />+48" GFCI <br />GFCI <br />CTV <br />GFCI +66" <br />AFCI <br />AFCI <br />CTV <br />GFCI +66" <br />GFCI +66"CTV <br />AFCIAFCI <br />AFCI <br />AFCI <br />+48" GFCI <br />GFCI 240V <br />100 AMP <br />240V-GFCI <br />WP <br />RA <br />N <br />G <br />E <br />SI <br />N <br />K <br />GFCI <br />WP <br />240V- GFCI <br />1.2 <br />1.2 <br />1.3 <br />1.4 <br />1.5 <br />1.6 <br />1.7 <br />1.8 <br />1.9 <br />1.10 <br />2.6 <br />2.6 <br />1.CONTRACTOR SHALL COMPLY WITH APPLICABLE LOCAL, STATE <br />AND FEDERAL CODES AND REGULATIONS PERTAINING TO <br />SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL <br />PROTECTION. <br />2.ALL ELECTRICAL OUTLET TO BE MOUNTED @ 15" A.F.F. <br />3.ALL APPLIANCES TO BE "ENERGY STAR". <br />4.PROVIDE TAMPER-RESISTANT FOR ALL 15 & 20 AMP <br />RECEPTACLES IN NEW CONSTRUCTION AREA PER CEC 406.12. <br />5.PROVIDE IN KITCHEN LOCAL EXHAUST SYSTEM VENTED TO <br />OUTDOOR WITH RATE = 280 CFM. <br />2.1 <br />FLUSH WALL MOUNTED PHONE RECEPTACLE <br />CTV FLUSH WALL MOUNTED CABLE TV RECEPTACLE <br />FLUSH WALL MOUNTED DUPLEX RECEPTACLE, TAMPER <br />RESISTANT <br />FLUSH WALL MOUNTED DEDICATED DUPLEX RECEPTACLE <br />FLUSH WALL MOUNTED HALF-SWITCHED DUPLEX RECEPTACLE <br />FLUSH WALL MOUNTED QUADRAPLEX RECEPTACLE <br />GROUND FAULT CIRCUIT INTERRUPTERGFCI <br />WATERPROOF RECEPTACLEWP <br />R <br />H <br />CR <br />RANGE HOOD WITH A MIN. EXHAUST RATE OF 100 <br />CFM - VENTED TO OUTSIDE <br />ELECTRICAL COOKING RANGE <br />REFRIGERATOR - PROVIDE WATER LINE <br />FAU <br />EP2 100AMP ELECTRICAL SUB-PANEL FOR ADU - MAINTAIN <br />36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION <br />W/H <br />NEW 100AMP ELECTRICAL SUB-PANEL FOR ADU. PROVIDE MIN <br />20 FEET UFER GROUND FOR MAIN PANEL- 100 AMP. <br />FAU LOCATED IN ATTIC WITH VERTICAL DUCT VENT TO <br />EXTERIOR. PROVIDE POWER CONNECTION . PROVIDE MINIMUM <br />36"x36" CLEAR WORKING SPACE PLATFORM IN FRONT OF UNIT. <br />2.2 <br />OUTDOOR RECEPTACLES SHALL BE LISTED AS <br />WEATHER RESISTANT PER SECTION 406.9(B) (1). <br />1.1 <br />PROVIDE A MINIMUM OF (1) 20-AMP CIRCUIT FOR BATHROOM <br />OUTLET. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. <br />THIS CIRCUIT MAY SERVE MORE THAN ONE BATHROOM, PER <br />CEC 210-52(C) (1). <br />1.2 <br />PROVIDE A MINIMUM OF (2) 20-AMP SMALL APPLIANCE <br />CIRCUITS FOR KITCHEN COUNTER TOPS. SUCH CIRCUIT <br />SHALL HAVE NO OTHER OUTLETS. LOAD SHALL BE BALANCED, <br />PER CEC 210-52(B) (2). <br />1.3 <br />CEILING MOUNTED SMOKE DETECTOR IN EACH BEDROOM & KITCHEN. <br />INSTALL +30" FROM AIR INTAKE SMOKE DETECTOR SYSTEM SHALL <br />DIRECT WIRED, INTERCONNECTED, SHALL BE EQUIPPED WITH A <br />BATTERY BACKUP AND SHALL EMIT A SIGNAL WHEN THE BATTERY IS <br />LOW. <br />A.AMINIMUM OF 20 FT. FROM PERMENANT COOKING EQUIPMENT <br />(OR 10 FT WITH PHOTO ELECTRIC TYPE.) <br />B.A MINIMUM OF 3 FT. FROM BATHROOM. <br />CEILING MOUNTED CARBON MONOXIDE ALARM, TO BE <br />INTERCONNECTED, SHALL BE EQUIPPED WITH A BATTERY BACKUP <br />RECESSED LED DOWN LIGHT FIXTURE <br />WALL MOUNTED EXTERIOR LED LIGHT FIXTURE, HIGH EFFICACY AND <br />CONTROL BY MOTION SENSOR AND PHOTO-SENSOR COMBINATIONS. <br />D / VS <br />LIGHT SWITCH. ALL SWITCHES TO HAVE DIMMER CONTROL, EXCEPT, <br />UTILITY & LAUNDRY RM, GARAGE <br />WALL MOUNTED BATHROOM LED LIGHT FIXTURE <br />EF <br />SD <br />CM <br />D INDICATE DIMMER <br />VS INDICATE OCCUPANCY SENSOR <br />WHOLE-BUILDING MECHANICAL VENTILATION SYSTEM WITH CFM <br />PER T24 - PANASONIC OR EQUAL. SYSTEM MUST DELIVER <br />CONTINUOUS VENTILATION AIRFLOW AT A RATE GREATER THAN <br />OR EQUAL TO THE SPECIFIED AND FAN SOUND RATING MUST <br />NOT EXCEED 1.0 FOR DWELLING OCCUPANT DENSITIES KNOW <br />TO BE GREATER THAN (NUMBER OF BEDROOM + 1), THE RATE <br />SHALL BE INCREASED BY 7.5 FOR EACH ADDITIONAL PERSON. <br />V <br />#FINISHED CEILING HEIGHT <br />CEILING MOUNTED EXHAUST FAN/FLUORESCENT LIGHT COMBINATION. <br />EXHAUST FAN TO EXTERIOR WITH RATE = 50 CFM. EXHAUST FAN MUST <br />BE CONTROLLED BY A HUMIDISTAT WHICH SHALL BE CAPABLE <br />ADJUSTMENT BETWEEN RELATIVE HUMINITY RANGE OF 50% TO 80%. <br />PROVIDE GARBAGE DISPOSAL CONNECTED TO HALF <br />-SWITCHED OUTLET UNDER KITCHEN SINK WITH ADJACENT <br />CONTROL SWITCH ABOVE CONTERTOP. <br />1.4 <br />SMOKE ALARMS WITHIN 20 FEET OF COOK TOP SHALL BE <br />IONIZED OR PHOTOELECTRIC TYPE. <br />2.3 <br />WHOLE-BUILDING VENTILATION SYSTEM LOCATION.2.4 <br />PROVIDE A MINIMUM 4" DIA. MOISTER EXHAUST DUCT (WITH <br />SMOOTH INTERIOR FINISH) TO OUTSIDE, EQUIPPED WITH <br />BACK-DRAFT DAMPER. DUCT LENGTH IS LIMITED OR REQUIRED <br />BY THE MANUFACTUER'S INSTALLATION INSTRUCTIONS AND <br />APPROVED BY THE BUILDING OFFICIAL. <br />2.5 <br />2.6 <br />PROVIDE KITCHEN LOCAL EXHAUST SYSTEM VENTED TO <br />OUTDOOR WITH RATE = 280 CFM . <br />PROVIDE LIGHTING WITH CONTROLLED BY VACANCY SENSOR <br />IN BATHROOM, W.I. CLOSET. <br />NEW 100AMP ELECTRICAL METER SUB PANEL FOR ADU. <br />PROVIDE MINIMUM 20 FEET UFER GROUND FOR NEW PANEL. <br />1.5 <br />1.6 <br />2.7 <br />2.8 <br />2.9 <br />6. AT LEAST ONE OF THE FOLLOWING SHALL BE PROVIDED: <br /> A. ESS READY INTERCONNECTION EQUIPMENT WITH A MINIMUM <br />BACKED-UP CAPACITY OF 60 AMPS AND A MINIMUM OF FOUR <br />ESS-SUPPLIED BRANCH CIRCUITS; OR <br /> B. A DEDICATED RACEWAY FROM THE MAIN SERVICE TO A <br />PANELBOARD (SUBPANEL) THAT SUPPLIES THE BRANCH CIRCUITS <br />IN SEC. 150.0(S)(2). ALL BRANCH CIRCUITS ARE PERMITTED TO BE <br />SUPPLIED BY THE MAIN SERVICE PANEL PRIOR TO THE <br />INSTALLATION OF AN ESS. THE TRADE SIZE OF THE RACEWAY <br />SHALL BE NOT LESS THAN 1 INCH. THE PANELBOARD THAT <br />SUPPLIES THE BRANCH CIRCUITS (SUBPANEL) MUST BE LABELED <br />“SUBPANEL SHALL INCLUDE ALL BACKED-UP LOAD CIRCUITS.” <br />7.A MINIMUM OF FOUR BRANCH CIRCUITS SHALL BE IDENTIFIED AND <br />HAVE THEIR SOURCE OF SUPPLY COLLOCATED AT A SINGLE <br />PANELBOARD SUITABLE TO BE SUPPLIED BY THE ESS. AT LEAST <br />ONE CIRCUIT SHALL SUPPLY THE REFRIGERATOR, ONE LIGHTING <br />CIRCUIT SHALL BE LOCATED NEAR THE PRIMARY EGRESS AND AT <br />LEAST ONE CIRCUIT SHALL SUPPLY A SLEEPING ROOM <br />RECEPTACLE OUTLET. <br />8.THE MAIN PANELBOARD SHALL HAVE A MINIMUM BUSBAR RATING <br />OF 225 AMPS. <br />9.SUFFICIENT SPACE SHALL BE RESERVED TO ALLOW FUTURE <br />INSTALLATION OF A SYSTEM ISOLATION EQUIPMENT/ TRANSFER <br />SWITCH WITHIN 3 FT. OF THE MAIN PANELBOARD. RACEWAYS <br />SHALL BE INSTALLED BETWEEN THE PANELBOARD AND THE <br />SYSTEM ISOLATION EQUIPMENT/TRANSFER SWITCH LOCATION TO <br />ALLOW THE CONNECTION OF BACKUP POWER SOURCE. <br />10.ALL INSTALLED LUMINARIES MUST BE HIGH EFFICACY IN <br />ACCORDANCE WITH TABLE 150.0-A. <br />11.EXHAUST FANS MUST BE SWITCHED SEPARATELY FROM <br />LIGHTING SYSTEMS. <br />12.IN BATHROOMS, GARAGE, LAUNDRY ROOM, UTILITY ROOM, AT <br />LEAST ONE LUMINARIES IN EACH OF THESE SPACES MUST BE <br />CONTROLLED BY VACANCY SENSOR. <br />13.OUTDOOR LIGHTING PERMANENTLY MOUNTED TO BUILDING <br />MUST MEET THE REQUIREMENT IN ITEM 150.0(k)3Ai (ON AND OFF <br />SWITCH) AND THE REQUIREMENTS IN EITHER ITEM 150.0(k)3Aii <br />(PHOTOCELL AND MOTION SENSOR) OR ITEM 150.0(k)3Aiii <br />(PHOTO CONTROL AND AUTOMATIC TIME SWITCH CONTROL, <br />ASTRONOMICAL TIME CLOCK, OR EMCS). <br />14.SHOW COMPLIANCE WITH THE FOLLOWING LIGHTING MEASURES: <br />[150.0(K) / 160.5(A)] <br />A.KITCHENS. ALL INSTALLED WATTAGE OF LUMINARIES IN <br />KITCHENS SHALL BE HIGH EFFICACY. <br />B.LIGHTING IN BATHROOMS, GARAGES, LAUNDRY ROOMS, <br />WALK-IN CLOSETS AND UTILITY ROOMS. ALL LUMINAIRES <br />SHALL BE HIGH EFFICACY AND SHALL BE CONTROLLED BY AN <br />OCCUPANCY OR VACANCY SENSOR. <br />C.HABITABLE SPACES. ALL LUMINAIRES SHALL BE HIGH <br />EFFICACY AND SHALL BE CONTROLLED BY A VACANCY/ <br />OCCUPANCY SENSOR OR DIMMER. <br />D.OUTDOOR LIGHTING. ALL LUMINAIRES MOUNTED TO THE <br />BUILDING OR TO OTHER BUILDINGS ON THE SAME LOT SHALL <br />BE HIGH EFFICACY LUMINAIRES AND SHALL BE CONTROLLED <br />BY A PHOTOCONTROL/MOTION SENSOR COMBINATION (WITH <br />OVERRIDE). SEE 150(K)3 FOR REQUIREMENTS. <br />FOR HEAT PUMP WATER HEATER: PROVIDE A DEDICATED <br />125V, 20A ( 10 AWG COPPER BRANCH CIRCUIT) ELECTRIC <br />RECEPTACLE THAT WITHIN 3 FEET FROM THE WATER HEATER <br />AND ACCESSIBLE TO THE WATER HEATER WITH NO <br />OBSTRUCTIONS. THERE SHALL BE A RESERVED SINGLE POLE <br />CIRCUIT BREAKER SPACE IN THE ELECTRICAL PANEL <br />LABELED "240V USE". BOTH ENDS OF CONDUCTOR SHALL BE <br />LABELED WITH WORD "WATER HEATER" AND BE <br />ELECTRICALLY ISOLATED. <br />HEAT PUMP WATER HEATER WITH 18''H. SHELF & METAL <br />PAN. HP WATER HEATER SHALL BE STRAPPED TO <br />STRUCTURE WITH 1 1 2" x 16GA STRAPS AT TOP & <br />BOTTOM WITH 3 8"DIA. x 3" LONG LAG BOLT - PROVIDE <br />DRAIN LINE WATER SHUT-OFF VALVE, POWER, GAS LINE. <br />A CONDENSATE DRAIN THAT IS NO MORE THAN 2" <br />HIGHER THAN THE BASE OF INSTALLED WH, AND <br />ALLOWS NATURAL DRAINING WITHOUT PUMP <br />ASSISTANCE. HP WATER HEATER SHALL BE INSTALLED <br />ACCORDING TO MANUFACTURER'S REQUIREMENTS. <br />HP <br />HP <br />HEAT PUMP FURNACE LOCATED IN ATTIC WITH <br />VERTICAL DUCT VENT TO EXTERIOR. PROVIDE POWER <br />CONNECTION . PROVIDE MINIMUM 36"x36" CLEAR <br />WORKING SPACE PLATFORM IN FRONT OF UNIT. <br />PROVIDE ACCESS DOOR . OPENING SHALL BE 30" x 30" WITH <br />30" MIN. HEADROOM. ACCESS DOOR MUST BE WITHIN 20 FEET <br />OF FURNACE UNIT AND SHOULD HAVE A CONTINUOUS SOLID <br />PATHWAY 24" MIN. WIDE. PROVIDE A SWITCH CONTROLLED <br />LIGHT. [CMC. 304.4.1] <br />FOR ELECTRIC CLOTHES DRYER READY: A DEDICATED 240 V <br />BRANCH CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3 FEET <br />FROM THE CLOTHES DRYER LOCATION AND ACCESSIBLE <br />WITH NO OBSTRUCTION. THE THE BRANCH CIRCUIT <br />CONDUCTORS SHALL BE RATED AT 30AMPS MIN. THE BLANK <br />COVER SHALL BE IDENTIFIED AS "240V READY". THERE SHALL <br />BE A RESERVED DOUBLE POLE CIRCUIT BREAKER SPACE IN <br />THE ELECTRICAL PANEL LABELED "240V DRYER". <br />FOR HEAT PUMP HEATER: IN ATTIC SPACE, PROVIDE A <br />DEDICATED 240 VOLT BRANCH CIRCUIT WIRING SHALL BE <br />INSTALLED WITHIN 3 FT. FROM THE FURNACE AND ACCESSIBLE <br />TO THE FURNACE WITH NO OBSTRUCTIONS.THERE SHALL BE A <br />RESERVED SINGLE POLE BREAKER SPACE IN THE ELECTRICAL <br />PANEL LABELED "240V FURNACE". <br />FOR ELECTRIC COOKTOP: A DEDICATED 240 V BRANCH <br />CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3 FEET FROM <br />THE CLOTHES DRYER LOCATION AND ACCESSIBLE WITH NO <br />OBSTRUCTION. THE THE BRANCH CIRCUIT CONDUCTORS <br />SHALL BE RATED AT 30AMPS MIN. THE BLANK COVER SHALL <br />BE INDENTIFIED AS "240V READY". THERE SHALL BE A <br />RESERVED DOUBLE POLE CIRCUIT BREAKER SPACE IN THE <br />ELECTRICAL PANEL LABELED "240V COOKTOP". <br />1.7 <br />1.8 <br />1.9 <br />1.10 SERVICE DISCONNECTING FOR ADU SHALL BE INSTALLED ADJ <br />ACENT TO SUB-PANEL OUTSIDE OF BUILDING. [CEC 230.70] <br />EXHAUST FAN WITH 50 CFM IN BATHROOM & LAUNDRY MUST <br />BE SWITCHED SEPARATELY FROM LIGHTING SYSTEMS. AND <br />SHOULD BE HUMIDISTAT FAN. <br />ELECTRICAL RECEPTACLE OUTLET, SWITCH & CONTROL HEIGHT <br />[R327.1.2] ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND <br />CONTROLS (INCLUDING CONTROLS FOR HEATING, VENTILATION <br />AND AIR CONDITIONING) INTENDED TO BE USED BY OCCUPANTS <br />SHALL BE LOCATED NO MORE THAN 48" MEASURED FROM THE TOP <br />OF THE OUTLET BOX AND NOT LESS THAN 15" MEASURED FROM <br />THE BOTTOM OF THE OUTLET BOX ABOVE THE FINISH FLOOR. <br />2 CEILING / LIGHTING PLAN <br />1/4"=1'-0" <br />REF. <br />TV <br />TV <br />TV <br />EF <br />D <br />280 CFM <br />50 CFM <br />SD <br />V <br />vs <br />EF <br />50 CFM <br />SD <br />SDCM <br />SDCM <br />SL <br />O <br />P <br />E <br />D <br />CE <br />I <br />L <br />I <br />N <br />G <br />9'-0" CLG. <br />9'-0" CLG. <br />5'-0" <br />SL <br />O <br />P <br />E <br />D <br />CE <br />I <br />L <br />I <br />N <br />G <br />SL <br />O <br />P <br />E <br />D <br />CE <br />I <br />L <br />I <br />N <br />G <br />SL <br />O <br />P <br />E <br />D <br />CE <br />I <br />L <br />I <br />N <br />G <br />9'-0" CLG. <br />5'-0" <br />vs <br />D <br />D <br />vs <br />D <br />VS <br />2.1 <br />2.2 <br />2.32.4 <br />2.5 <br />2.7 <br />2.7 <br />2.8 <br />2.8 <br />2.9 <br />2.1 <br />2.7 <br />2.6 <br />2.6 <br />2.8 <br />doorbell <br />48 <br />" <br /> <br />M <br />A <br />X <br />1' <br />- <br />3 <br />" <br />MI <br />N <br />4' <br />- <br />0 <br />" <br /> <br />M <br />A <br />X <br />provide additional backing for <br />fold away grab bar. <br />verify requirement with <br />selected manufacturer <br />grab bar reinforcement for <br />water closets <br />back wall side wall <br />2' <br />- <br />8 <br />" <br /> <br />M <br />A <br />X <br />2' <br />- <br />8 <br />" <br /> <br />M <br />A <br />X <br />3' <br />- <br />2 <br />" <br /> <br />M <br />I <br />N <br />3'-6" MIN1'-0" <br />MAX <br />3' <br />- <br />2 <br />" <br /> <br />M <br />I <br />N <br />2'-2" <br />MIN <br />3'-4" MIN <br />1' <br />- <br />4 <br />" <br />MI <br />N <br />1'-4" <br />32 <br />" <br />full width at all <br />shower stall walls <br />electrical receptacle outlet, switch & <br />control mounting heights <br />push button <br />doorbell heights <br />finish floor <br />side wallback wall grab bar reinforcement <br />for shower <br />39 <br /> <br />1 <br />/ <br />4 <br />" <br />full width at all <br />shower stall walls <br />Reinforcement shall not be <br />less than 2x8 or other <br />construction material providing <br />equal height and load capacity <br />AGING-IN-PLACE/FALL PREVENTION FEATURES <br /> C <br />O <br />V <br />E <br />R <br />E <br />D <br /> <br />P <br />A <br />T <br />I <br />O <br /> <br />D <br />E <br />M <br />O <br />L <br />I <br />T <br />I <br />O <br />N <br />31 <br />0 <br />9 <br /> <br />S <br /> <br />A <br />r <br />t <br />e <br />s <br />i <br />a <br /> <br />S <br />t <br /> <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br /> <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />NE <br />W <br /> <br />D <br />E <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br />31 <br />0 <br />9 <br /> <br />S <br /> <br />A <br />r <br />t <br />e <br />s <br />i <br />a <br /> <br />S <br />t <br /> <br />U <br />n <br />i <br />t <br /> <br /># <br />2 <br /> <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br /> <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />11 <br />8 <br />8 <br />1 <br /> <br />s <br />t <br />k <br /> <br />r <br />a <br /> <br />a <br />r <br />e <br />n <br /> <br />r <br />v <br />e <br /> <br /> <br />C <br />A <br /> <br /> <br />9 <br />2 <br />8 <br />4 <br />0 <br /> <br /> <br /> <br /> <br /> <br />T <br />: <br /> <br />7 <br />1 <br />4 <br />. <br />6 <br />5 <br />1 <br />. <br />9 <br />9 <br />4 <br />5 <br /> <br /> <br /> <br />E <br />: <br /> <br />e <br />s <br />i <br />n <br />2 <br />i <br />@ <br />a <br />. <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1