Laserfiche WebLink
CONCRETE WALL <br />PER PLAN <br />DOWELS TO MATCH <br />T&B BAR SIZE AND <br />SPACING <br />STRINGER & LANDING REINFORCEMENT <br />PER SCHEDULE ON 2/- (NOSING BAR AND <br />TREAD BAR ARE NOT SHOWN FOR CLARITY <br />1' - 6" MIN, TYPADD'L (2) #5, TYP <br />SOG/PAVER PER CIVIL <br />12" MIN <br />12" MIN <br />TYP <br />2" CLR <br />#4 DOWEL INTO <br />SIDE WALLS <br />NOTE: SEE 1 & 2/S5.03 FOR ADDL INFO NOT SHOWN. <br />PER <br />ARCH <br />PE <br />R <br />AR <br />C <br />H <br />8" TREAD SLAB <br />#4 NOSING BAR, TYP <br />#5 @ 12" OC EA WAY, T&B <br />CONCRETE LANDING <br />WF BEAM PER PLAN <br />CONC FILLED <br />METAL DECK <br />PER PLAN <br />T.O.SLAB <br />PER PLAN <br />T.O. LANDING <br />PER PLAN <br />NOTE: <br />SEE ARCH DRAWINGS <br />FOR STAIR PROFILE. <br />1" CLR <br />2' - 6" <br />#3 @ 18" OC EACH TREAD <br />Ls <br />PER ARCH <br />10 <br />2 <br />S5.03 TYP <br />PROJECT <br />COPYRIGHT LOC, INC <br />ORIGINAL SHEET SIZE: 42" X 30" <br />LOC <br />CLIEN <br />ARCHITEC <br />CONSULTANT <br />AC <br />C <br /> <br />R <br />e <br />v <br />i <br />t <br /> <br />2 <br />0 <br />2 <br />2 <br /> <br />h <br />o <br />s <br />t <br />e <br />d <br /> <br />b <br />y <br /> <br />L <br />O <br />C <br />2/12/2025 12:03:27 PM <br />Autodesk Docs://2308_SAZ_Hive/2300175_SAZ_KPFF_R22.rvt <br />2308 <br />TYPICAL <br />CONCRETE <br />DETAILS <br />FEBRUARY 13, 2025 <br />PLAN CHECK <br />SUBMITTAL 02 <br />S5.03 <br />SANTA ANA ZOO <br />1801 E CHESTNUT AVE, SANTA ANA, CA <br />92701 <br />KPFF <br />STRUCTURAL ENGINEER <br />LOC ARCHITECTS <br />KPFF <br />CIVIL ENGINEER <br />BORDER <br />LANDSCAPE ARCHITECT <br />ABRARI AND ASSOCIATES <br />MEP ENGINEER <br />ASSOCIATED SOILS ENGINEERING <br />GEOTECHNICAL ENGINEER <br />700 S. FLOWER, SUITE 2100 <br />LOS ANGELES, CA 90017 <br />213 372 5111 <br />Ramzi.hodali@kpff.com <br />700 S. FLOWER, SUITE 2100 <br />LOS ANGELES, CA 90017 <br />213 372 5111 <br />Sharad.Ganju@kpff.com <br />724 S. SPRING ST, SUITE 701 <br />LOS ANGELES, CA 90014 <br />213 372 5111 <br />Darren@border-la.com <br />1713 S. STANDARD AVE <br />GLENDALE, CA 91201 <br />818 956 1900 <br />Telma@abrari.com <br />2860 WALNUT AVE. <br />SIGNAL HILL, CA 90755 <br />562 897 2749 <br />Ted@associatedsoils.com <br />3203 E. 4TH ST <br />LOS ANGELES, CA 90063 <br />213 537 0480 <br />Office@loc-arch.com <br />1801 E. CHESTNUT AVE. <br />SANTA ANA, CA 92701 <br />714 647 6575 <br />Efisher@santa-ana.org <br />SANTA ANA ZOO <br />EDUCATION <br />HUB <br />SCALE : 1" = 1'-0"2 TYPICAL EXTERIOR CONCRETE STAIR SECTION <br />SCALE : 1 1/2" = 1'-0"3 CONC STAIR STRINGER BOTTOM DETAIL <br />SCALE : 3/4" = 1'-0"1 CONC STAIR STRINGER BOTTOM DETAIL <br />3 <br />No. Description Date <br />3 PLAN CHECK SUBMITTAL 02 02-13-2025 <br />REGISTERED PROFESSIONAL ENGINEERRAMZI S . HODAL <br />I <br />STRUC T URALSTATE OF CAL IFORNIA <br />2/13/2025