TJI BLKG AT 24" OC <br />SEE <br />TJI FRAMING <br />SEE PLAN <br />STUD WALL <br />SEE PLAN <br />(2) 2x4 TOP PLATES <br />(1) 10d EA SIDE <br />STUDS, SEE <br />PLAN <br />TJI BLKG <br />AT 24" OC <br />SEE <br />(2) 16d AT EACH <br />BLKG PANEL <br />FINISH PER ARCH OVER <br />PLYWOOD SHEATHING & <br />TJI JOISTS SEE PLAN <br />WALL ABOVE <br />WHERE IT <br />OCCURS <br />SEE PLAN CONTINUOUS <br />2x SOLE PLATE <br />W/ (2) 16d AT <br />EACH BLKG <br />PANEL <br />/5 S6.21/5 S6.21 <br />3 <br />3 <br />3 <br />STUDS, <br />SEE PLAN <br />CONTINUOUS <br />2x SOLE <br />PLATE W/ 16d <br />AT 8" OC <br />STAGGERED <br />16d AT 8" OC <br />CONTINUOUS <br />TJI ABOVE <br />WALL <br />W/ 10d TOE <br />NAIL AT 6" OC <br />TO TOP PLATE <br />DBL TJI'S <br />BELOW WALL <br />SEE PLAN <br />10d AT 4" OC TO <br />TJI BLKG PANEL <br />TJI BLKG AT 48" OC <br />SEE <br />STUD WALL <br />SEE PLAN <br />FINISH PER ARCH OVER <br />PLYWOOD SHEATHING & <br />TJI JOISTS SEE PLAN <br />WALL <br />ABOVE <br />WHERE IT <br />OCCURS <br />SEE PLAN <br />/5 S6.21 3 <br />3 <br />WINDOW, S.A.D. <br />OPENING, S.A.D. <br />STUD WALL, SEE PLAN <br />SILL, SEE SCHEDULE <br />HDR, SEE SCHEDULE & PLAN <br />CRIPPLE STUDS <br />FINISH PER ARCH OVER <br />PLYWOOD SHEATHING <br />& TJI JOISTS, SEE PLAN <br />EDGE NAIL <br />EDGE NAIL <br />PLYWOOD SHEATHING <br />SEE PLAN & SCHED <br />NOTE: <br />FOR INFO NOT SHOWN <br />SEE DETAIL 4/-. <br />S.A.D. <br />PLYWOOD SHEATHING <br />SEE PLAN & SCHED <br />3 <br />1 3/4" LSL RIM BOARD <br />TJI BLOCKING PANEL <br />(1) 10d EACH SIDE TO <br />TOP PLATE, TYPICAL <br />PLYWOOD <br />SHEATHING <br />PLYWOOD <br />SHEATHING <br />PLYWOOD JT ON <br />RIM BOARD <br />PLYWOOD <br />SHEATHING <br />TJI JOIST, SEE PLAN <br />EDGE NAIL <br />3/4" MIN PLYWOOD JOINT, S.A.D. <br />STUDS, SEE PLAN <br />SQUASH BLOCK UNDER POST OR DBL <br />JAMB STUDS, SOLID BLOCK AT TIEDOWNS <br />PLYWOOD SHEATHING & TJI <br />JOISTS SEE PLAN <br />PLYWOOD SHEATHING <br />SEE PLAN & SCHEDULE <br />STUDS, SEE PLAN <br />CONTINUOUS (2) 2x TOP PLATES <br />10d AT 4" OC TO <br />TJI BLKG PANEL <br />EDGE NAIL <br />TJI BLKG AT 48" OC <br />A35'S PER <br />SHEARWALL SEE SCHEDULE <br />CONT 1 3/4" LSL RIM BOARD <br />PARAPET DETAIL, <br />SEE , TYP/5 S6.22 <br />CONT FRT SOLE PLATE <br />FLUSHED HEADER <br />SEE SCHEDULE & PLAN <br />EDGE NAIL <br />NOTE: <br />FOR INFO NOT SHOWN SEE DETAIL 7/-. <br />PARAPET DETAIL, <br />SEE , TYP/5 S6.22 <br />STUDS, SEE PLAN <br />FRAMING ANCHOR, SEE <br />SHEAR WALL SCHEDULE <br />EDGE NAIL <br />3 1/2" LSL BLOCKING, TYPICAL <br />LSL BLKG <br />PLYWOOD <br />SHEATHING <br />PLYWOOD SHEATHING <br />SEE PLAN & SCHEDULE <br />FINISH PER ARCH OVER <br />PLYWOOD SHEATHING <br />& TJI JOISTS SEE PLAN <br />(1) 10d EACH SIDE <br />TO TOP PLATE, <br />TYPICAL <br />CONTINUOUS (2) 2x TOP PLATES <br />(W/ (1) ADDL SHAPED TOP <br />PLATE, MATCHING ROOF SLOPE <br />PER ARCH) <br />PLYWOOD SHEATHING <br />3 <br />B.N. <br />PLYWOOD <br />SHEATHING <br />PLYWOOD SHEATHING <br />PLYWOOD SHEATHING <br />SEE PLAN & SCHEDULE <br />E.N. <br />1 3/4" LSL RIM BOARD <br />TJI BLOCKING PANEL <br />(1) 10d EACH SIDE TO <br />TOP PLATE, TYPICAL <br />TJI JOISTS <br />SEE PLAN <br />FINISH PER ARCH OVER <br />PLYWOOD SHEATHING <br />& TJI JOISTS SEE PLAN <br />10d AT 4" OC TO <br />TJI BLOCKING PANEL <br />TJI BLKG AT 48"o.c. <br />CONT SHAPED 1 3/4" PSL <br />STUDS, SEE PLAN <br />CONTINUOUS (2) 2x TOP PLATES <br />E.N.A35 PER SHEAR WALL <br />SCHEDULE <br />3 <br />PLYWOOD <br />SHEATHING <br />CONTINUOUS <br />2x SOLE PLATE <br />W/ 16d AT 8" OC <br />(1) 10d EACH SIDE TO <br />TOP PLATE, TYPICAL <br />STUD WALL, SEE PLAN <br />FINISH PER ARCH OVER <br />PLYWOOD SHEATHING <br />& TJI JOISTS SEE PLAN <br />CONTINUOUS <br />(2) 2x TOP PLATES <br />(1) 10d EACH SIDE TO <br />TOP PLATE, TYPICAL <br />CONTINUOUS <br />JOIST <br />DO NOT SPLICE <br />WALL ABOVE <br />WHERE IT OCCURS <br />SEE PLAN <br />TJI BLKG <br />WHERE WALL <br />ABOVE OCCURS <br />STUDS, SEE PLAN <br />CONTINUOUS <br />2x SOLE PLATE <br />W/ 16d AT 8" OC <br />TJI BLKG <br />SEE <br />TJI BLKG AT <br />WALL ABOVE <br />/5 S6.21 <br />3 <br />3 <br />EDGE NAIL <br />3/4" MIN PLYWOOD JOINT, S.A.D. <br />CONTINUOUS 2x SOLE PLATE <br />W/ 16d AT 8" OC, TYP U.N.O. <br />AT SHEARWALLS SEE SCHED <br />STUDS, SEE PLAN <br />PLYWOOD <br />SHEATHING <br />RIM BOARD <br />TJI JOISTS, SEE PLAN <br />PLYWOOD <br />SHEATHING <br />PLYWOOD JT ON <br />RIM BOARD <br />PLYWOOD <br />SHEATHING <br />SQUASH BLOCK UNDER POST OR DBL <br />JAMB STUDS, SOLID BLOCK AT TIEDOWNS <br />PLYWOOD <br />SHEATHING & TJI JOISTS <br />SEE PLAN <br />PLYWOOD SHEATHING <br />SEE PLAN & SCHEDULE <br />STUDS, SEE PLAN <br />CONTINUOUS (2) 2x TOP PLATES <br />(1) 10d EACH SIDE TO <br />TOP PLATE, TYPICAL <br />PLYWOOD SHEATHING <br />SEE PLAN & SCHEDULE <br />EDGE NAIL <br />EDGE NAIL <br />WEB STIFFENER, SEE <br />A35'S PER SHEARWALL <br />SCHEDULE <br />CONT 1 3/4" LSL RIM BOARD <br />PARAPET DETAIL, <br />SEE , TYP/5 S6.22 <br />CONT FRT <br />SOLE PLATE2x6 FRT STUD, TYP <br />FLUSHED HEADER <br />SEE SCHEDULE & <br />PLAN <br />PLYWOOD SHEATHING <br />& TJI JOISTS, SEE PLAN <br />NOTE: <br />FOR INFO NOT SHOWN <br />SEE DETAIL 4/-. <br />EDGE NAIL <br />PLYWOOD SHEATHING <br />SEE PLAN & SCHED <br />PER ARCH, <br />1' - 3" MAX <br />SHEATHING TYPE (A) <br />PER SHEARWALL <br />SCHED, TYP <br />EN <br />1/2" LAG SCREW <br />@ 8" OC, <br />STAGGERED <br />PLYWOOD <br />SHEATHING <br />SEE PLAN <br />WINDOW, S.A.D. <br />OPENING, S.A.D. <br />STUD WALL, SEE PLAN <br />HDR, SEE SCHEDULE <br />CRIPPLE STUDS <br />SILL, SEE SCHEDULE <br />FINISH PER ARCH OVER <br />PLYWOOD SHEATHING <br />& TJI JOISTS, SEE PLAN <br />NOTE: <br />FOR INFO NOT SHOWN <br />SEE DETAIL 7/-. <br />S.A.D. <br />3 <br />PROJECT <br />COPYRIGHT LOC, INC <br />ORIGINAL SHEET SIZE: 42" X 30" <br />LOC <br />CLIEN <br />ARCHITEC <br />CONSULTANT <br />AC <br />C <br /> <br />R <br />e <br />v <br />i <br />t <br /> <br />2 <br />0 <br />2 <br />2 <br /> <br />h <br />o <br />s <br />t <br />e <br />d <br /> <br />b <br />y <br /> <br />L <br />O <br />C <br />2/12/2025 12:03:35 PM <br />Autodesk Docs://2308_SAZ_Hive/2300175_SAZ_KPFF_R22.rvt <br />2308 <br />TJI-SHEAR <br />WALL <br />TRANSFER <br />DETAILS <br />FEBRUARY 13, 2025 <br />PLAN CHECK <br />SUBMITTAL 02 <br />S6.22 <br />SANTA ANA ZOO <br />1801 E CHESTNUT AVE, SANTA ANA, CA <br />92701 <br />KPFF <br />STRUCTURAL ENGINEER <br />LOC ARCHITECTS <br />KPFF <br />CIVIL ENGINEER <br />BORDER <br />LANDSCAPE ARCHITECT <br />ABRARI AND ASSOCIATES <br />MEP ENGINEER <br />ASSOCIATED SOILS ENGINEERING <br />GEOTECHNICAL ENGINEER <br />700 S. FLOWER, SUITE 2100 <br />LOS ANGELES, CA 90017 <br />213 372 5111 <br />Ramzi.hodali@kpff.com <br />700 S. FLOWER, SUITE 2100 <br />LOS ANGELES, CA 90017 <br />213 372 5111 <br />Sharad.Ganju@kpff.com <br />724 S. SPRING ST, SUITE 701 <br />LOS ANGELES, CA 90014 <br />213 372 5111 <br />Darren@border-la.com <br />1713 S. STANDARD AVE <br />GLENDALE, CA 91201 <br />818 956 1900 <br />Telma@abrari.com <br />2860 WALNUT AVE. <br />SIGNAL HILL, CA 90755 <br />562 897 2749 <br />Ted@associatedsoils.com <br />3203 E. 4TH ST <br />LOS ANGELES, CA 90063 <br />213 537 0480 <br />Office@loc-arch.com <br />1801 E. CHESTNUT AVE. <br />SANTA ANA, CA 92701 <br />714 647 6575 <br />Efisher@santa-ana.org <br />SANTA ANA ZOO <br />EDUCATION <br />HUB <br />SCALE : 1" = 1'-0"2 <br />NON-BEARING WALL - <br />JOIST PARALLEL <br />SCALE : 1" = 1'-0"3 <br />NON-BEARING WALL - <br />JOISTS PARALLEL <br />SCALE : 1" = 1'-0"6 <br />DROP HEADER - <br />JOIST PERPENDICULAR <br />SCALE : 1" = 1'-0"7 <br />EXTERIOR SHEAR WALL - <br />JOIST PARALLEL <br />SCALE : 1" = 1'-0"8 <br />TYPICAL EXTERIOR WALL - <br />JOIST PARALLEL <br />SCALE : 1" = 1'-0"10 <br />INTERIOR SHEAR WALL - <br />JOIST PERPENDICULAR <br />SCALE : 1" = 1'-0"11 <br />INTERIOR SHEAR WALL - <br />JOIST PARALLEL <br />SCALE : 1" = 1'-0"1 <br />NON-BEARING WALL - JOIST <br />PERPENDICULAR <br />SCALE : 1" = 1'-0"4 <br />EXTERIOR SHEAR WALL - <br />JOIST PERPENDICULAR <br />SCALE : 1" = 1'-0"5 <br />TYPICAL EXTERIOR WALL - <br />JOIST PERPENDICULAR <br />SCALE : 1" = 1'-0"9 DROP HEADER - JOIST PARALLEL <br />No. Description Date <br />3 PLAN CHECK SUBMITTAL 02 02-13-2025 <br />REGISTERED PROFESSIONAL ENGINEERRAMZI S . HODAL <br />I <br />STRUC T URALSTATE OF CAL IFORNIA <br />2/13/2025