Laserfiche WebLink
M-005 <br />SP <br />E <br />C <br />I <br />F <br />I <br />C <br />A <br />T <br />I <br />O <br />N <br />S <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />Z <br />O <br />O <br /> <br />E <br />D <br />U <br />C <br />A <br />T <br />I <br />O <br />N <br /> <br />H <br />U <br />B <br />18 <br />2 <br />1 E <br /> <br /> <br />C <br />H <br />E <br />S <br />T <br />N <br />U <br />T <br /> <br />A <br />V <br />E <br />N <br />U <br />E <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />CFOE OFILA <br />9-30-25 <br />TATS ACINAHCEMExp. No. <br />ARHAHS <br />EFORPDERETSI <br />E <br />G <br />R <br />AINR <br />REENIGNEL <br />M24912 NAZRAFM <br />ER <br />E <br />NIGNELANOISS <br />DATE: 6.12.2025 <br />SCALE: SEE PLANS <br />ISSUE DATE <br />REVISION DATE <br />SF <br /> <br />E <br />n <br />g <br />i <br />n <br />e <br />e <br />r <br />i <br />n <br />g <br />11 <br />0 <br />4 <br />1 <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />M <br />o <br />n <br />i <br />c <br />a <br /> <br />B <br />l <br />v <br />d <br />. <br />, <br /> <br />S <br />u <br />i <br />t <br />e <br /> <br />5 <br />0 <br />9 <br />LO <br />S <br /> <br />A <br />N <br />G <br />E <br />L <br />E <br />S <br />, <br /> <br />C <br />A <br /> <br />9 <br />0 <br />0 <br />2 <br />5 <br />Te <br />l <br />. <br /> <br />( <br />3 <br />1 <br />0 <br />) <br /> <br />3 <br />8 <br />6 <br /> <br />2 <br />4 <br />0 <br />0 <br />sp <br />f <br />a <br />r <br />z <br />a <br />n <br />@ <br />y <br />a <br />h <br />o <br />o <br />. <br />c <br />o <br />m <br />SECTION 232301 - VRV/VRF REFRIGERANT PIPING <br />PART 1 - GENERAL <br />1.1 SUMMARY <br />A. THIS SECTION INCLUDES REFRIGERANT PIPING USED FOR VRV/VRF AIR-CONDITIONING APPLICATIONS. <br />1.2 PERFORMANCE REQUIREMENTS <br />A. LINE TEST PRESSURE FOR REFRIGERANT R-410A: <br />1. SUCTION (LOW PRESSURE GAS) LINES: 550 PSIG, OR PER EQUIPMENT MANUFACTURERS <br />RECOMMENDATION. <br />2. HOT-GAS (HIGH PRESSURE GAS) AND LIQUID LINES: 550 PSIG, OR PER EQUIPMENT MANUFACTURERS <br />RECOMMENDATION. <br />1.3 SUBMITTALS <br />A. PRODUCT DATA: FOR EACH TYPE OF VALVE AND REFRIGERANT PIPING SPECIALTY INDICATED. <br />INCLUDE PRESSURE DROP BASED ON MANUFACTURER'S TEST DATA. <br />B. SHOP DRAWINGS: SHOW LAYOUT OF REFRIGERANT PIPING AND SPECIALTIES, INCLUDING PIPE, TUBE, <br />AND FITTING SIZES, VALVE ARRANGEMENTS AND LOCATIONS, WALL AND FLOOR PENETRATIONS, AND <br />EQUIPMENT CONNECTION DETAILS. SHOW INTERFACE AND SPATIAL RELATIONSHIPS BETWEEN PIPING AND <br />EQUIPMENT. <br />1. REFRIGERANT PIPING INDICATED ON DRAWINGS IS SCHEMATIC ONLY. SIZE PIPING AND DESIGN <br />ACTUAL PIPING LAYOUT, INCLUDING SPECIALTIES, AND PIPE AND TUBE SIZES TO ACCOMMODATE, AS A <br />MINIMUM, EQUIPMENT PROVIDED, ELEVATION DIFFERENCE BETWEEN COMPRESSOR AND EVAPORATOR, <br />AND LENGTH OF PIPING TO ENSURE PROPER OPERATION AND COMPLIANCE WITH WARRANTIES OF <br />CONNECTED EQUIPMENT. <br />C. FIELD QUALITY-CONTROL TEST REPORTS. <br />D. OPERATION AND MAINTENANCE DATA. <br />1.4 QUALITY ASSURANCE <br />A. COMPLY WITH ASHRAE 15, "SAFETY CODE FOR REFRIGERATION SYSTEMS." <br />B. COMPLY WITH ASME B31.5, "REFRIGERATION PIPING AND HEAT TRANSFER COMPONENTS." <br />C. INSTALLER QUALIFICATION: ONLY TRAINED INSTALLERS SKILLED IN REFRIGERATION PIPE <br />INSTALLATION AND BRAZING OF COPPER TUBING SHOULD BE USED. <br />1.5 PRODUCT STORAGE AND HANDLING <br />A. STORE PIPING IN A CLEAN AND PROTECTED AREA WITH END CAPS IN PLACE TO ENSURE THAT PIPING <br />INTERIOR AND EXTERIOR ARE CLEAN WHEN INSTALLED. <br />PART 2 - PRODUCTS <br />2.1 COPPER TUBE AND FITTINGS <br />A. COPPER TUBE: <br />1. STRAIGHT LENGTHS: ASTM B 75, UNS C12200, H55 TEMPER (LIGHT DRAWN), ACR BENDING QUALITY; <br />CLEANED, EDDY CURRENT TESTED, AND PLUGGED PER ASTM B 280. <br />a. REFTEKK "HHC" <br />2. COILED: ASTM B 280, UNS C12200, O60 TEMPER (SOFT ANNEALED), ACR, CLEANED AND CAPPED <br />a. REFTEKK "CCE" <br />B. BRAZING FILLER METALS: AWS A5.8. <br />a. REFTEKK "BRG" <br />C. FIELD SWAGED BRAZING CUPS: MSS-SP-73, ASME B 16.50 <br />D. FIELD BENDS (ALL ANGLES): ASME B31.5 <br />2.2 VALVES AND SPECIALTIES <br />A. SERVICE VALVES: <br />1. BODY: FORGED BRASS WITH BRASS CAP INCLUDING KEY END TO REMOVE CORE. <br />2. CORE: REMOVABLE BALL-TYPE CHECK VALVE WITH STAINLESS-STEEL SPRING. <br />3. SEAT: POLYTETRAFLUOROETHYLENE. <br />4. END CONNECTIONS: SOCKET ENDS. <br />5. WORKING PRESSURE RATING: 700 PSIG. <br />6. MAXIMUM OPERATING TEMPERATURE 250 DEG. F <br />7. VALVES MUST BE SPECIFICALLY RATED FOR R-410A. <br />2.3 REFRIGERANTS <br />A. AVAILABLE MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, MANUFACTURERS <br />OFFERING PRODUCTS THAT MAY BE INCORPORATED INTO THE WORK INCLUDE, BUT ARE NOT LIMITED TO, <br />THE FOLLOWING: <br />B. ASHRAE 34, R-410A: R-32/R-125 (50.0/50.0) <br />PART 3 - EXECUTION <br />3.1 PIPING APPLICATIONS <br />A. SUCTION (LOW PRESSURE GAS), HOT GAS (HIGH PRESSURE GAS) AND LIQUID LINES OD 5/8" AND <br />SMALLER FOR CONVENTIONAL AIR-CONDITIONING, HEAT PUMP, AND HEAT RECOVERY APPLICATIONS: <br />COPPER, TYPE ACR, O60 (SOFT ANNEALED)-TEMPER TUBING AND FIELD BENT FITTINGS WITH BRAZED <br />JOINTS. <br />B. SUCTION (LOW PRESSURE GAS), HOT GAS (HIGH PRESSURE GAS), AND LIQUID LINES OD 2-1/8" AND <br />SMALLER FOR ED CONVENTIONAL AIR-CONDITIONING, HEAT PUMP, AND HEAT RECOVERY APPLICATIONS: <br />STRAIGHT LENGTHS, COPPER, TYPE ACR TYPE L, H55 (LIGHT DRAWN)-TEMPER TUBING AND FIELD BENT <br />FITTINGS WITH BRAZED JOINTS. <br />3.2 VALVE AND SPECIALTY APPLICATIONS <br />A. INSTALL SERVICE VALVES AS SHOWN ON PLANS OR AS REQUIRED TO ISOLATE SYSTEM <br />COMPONENTS. <br />3.3 PIPING INSTALLATION <br />A. DRAWING PLANS, SCHEMATICS, AND DIAGRAMS INDICATE GENERAL LOCATION AND ARRANGEMENT <br />OF PIPING SYSTEMS; <br />INDICATED LOCATIONS AND ARRANGEMENTS WERE USED TO SIZE PIPE AND CALCULATE FRICTION LOSS, <br />EXPANSION, PUMP SIZING, AND OTHER DESIGN CONSIDERATIONS. INSTALL PIPING AS INDICATED UNLESS <br />DEVIATIONS TO LAYOUT ARE APPROVED ON SHOP DRAWINGS. <br />B. INSTALL REFRIGERANT PIPING ACCORDING TO ASHRAE 15. <br />C. INSTALL PIPING IN CONCEALED LOCATIONS UNLESS OTHERWISE INDICATED AND EXCEPT IN <br />EQUIPMENT ROOMS AND SERVICE AREAS. <br />D. INSTALL PIPING INDICATED TO BE EXPOSED AND PIPING IN EQUIPMENT ROOMS AND SERVICE AREAS <br />AT RIGHT ANGLES OR PARALLEL TO BUILDING WALLS. DIAGONAL RUNS ARE PROHIBITED UNLESS <br />SPECIFICALLY INDICATED OTHERWISE. <br />E. INSTALL PIPING ABOVE ACCESSIBLE CEILINGS TO ALLOW SUFFICIENT SPACE FOR CEILING PANEL <br />REMOVAL. <br />F. INSTALL PIPING ADJACENT TO MACHINES TO ALLOW SERVICE AND MAINTENANCE. <br />G. INSTALL PIPING FREE OF SAGS AND BENDS <br />. <br />H. FIELD BEND CHANGES IN DIRECTION. <br />I. SELECT SYSTEM COMPONENTS WITH PRESSURE RATING EQUAL TO OR GREATER THAN MAXIMUM <br />ALLOWABLE WORKING <br />PRESSURE. <br />J. INSTALL PIPING AS SHORT AND DIRECT AS POSSIBLE, WITH A MINIMUM NUMBER OF JOINTS, ELBOWS, <br />AND FITTINGS. <br />K. ARRANGE PIPING TO ALLOW INSPECTION AND SERVICE OF REFRIGERATION EQUIPMENT. INSTALL <br />VALVES AND SPECIALTIES IN ACCESSIBLE LOCATIONS TO ALLOW FOR SERVICE AND INSPECTION. INSTALL <br />ACCESS DOORS OR PANELS AS SPECIFIED IN DIVISION 08 SECTION "ACCESS DOORS AND FRAMES" IF <br />VALVES OR EQUIPMENT REQUIRING MAINTENANCE IS CONCEALED BEHIND FINISHED SURFACES. <br />L. INSTALL INSULATED REFRIGERANT PIPING IN WATER-TIGHT PROTECTIVE CONDUIT WHERE INSTALLED <br />BELOWGROUND. <br />M. PROVIDE JACKETED INSULATION IN LOCATIONS WHERE EXPOSED TO MECHANICAL INJURY. <br />N. WHEN BRAZING, REMOVE SOLENOID-VALVE COILS AND SIGHT GLASSES; ALSO, REMOVE <br />VALVE STEMS, SEATS, AND PACKING, AND ACCESSIBLE INTERNAL PARTS OF REFRIGERANT SPECIALTIES. <br />DO NOT APPLY HEAT NEAR EXPANSION-VALVE BULB. <br />O. INSTALL PIPING WITH ADEQUATE CLEARANCE BETWEEN PIPE AND ADJACENT WALLS AND HANGERS <br />OR BETWEEN PIPES FOR INSULATION INSTALLATION. <br />P. IDENTIFY REFRIGERANT PIPING AND VALVES ACCORDING TO DIVISION 23 SECTION "IDENTIFICATION <br />FOR HVAC PIPING AND EQUIPMENT." <br />Q. INSTALL SLEEVES FOR PIPING PENETRATIONS OF WALLS, CEILINGS, AND FLOORS. COMPLY WITH <br />REQUIREMENTS FOR SLEEVES SPECIFIED IN DIVISION 23 SECTION "SLEEVES AND SLEEVE SEALS FOR HVAC <br />PIPING." <br />R. INSTALL SLEEVE SEALS FOR PIPING PENETRATIONS OF CONCRETE WALLS AND SLABS. COMPLY WITH <br />REQUIREMENTS FOR SLEEVE SEALS SPECIFIED IN DIVISION 23 SECTION "SLEEVES AND SLEEVE SEALS FOR <br />HVAC PIPING." <br />S. INSTALL ESCUTCHEONS FOR PIPING PENETRATIONS OF WALLS, CEILINGS, AND FLOORS. COMPLY <br />WITH REQUIREMENTS FOR ESCUTCHEONS SPECIFIED IN DIVISION 23 SECTION "ESCUTCHEONS FOR HVAC <br />PIPING." <br />T. PROVIDE PROPER COMPENSATION FOR PIPE/TUBE EXPANSION AND CONTRACTION PER EQUIPMENT <br />MANUFACTURERS RECOMMENDATIONS. <br />3.4 PIPE JOINT CONSTRUCTION <br />A. BRAZED JOINTS: CONSTRUCT JOINTS ACCORDING TO AWS'S "BRAZING HANDBOOK," CHAPTER "PIPE <br />AND TUBE." <br />1. USE TYPE BCUP-5 (15% AG, 80% CU, 5% P), COPPER-PHOSPHORUS ALLOY PRE-FORMED BRAZING <br />RINGS FOR JOINING COPPER SWAGE FITTINGS AND COPPER SOCKET FITTINGS WITH COPPER PIPE. DO NOT <br />USE FLUX. <br />2. USE TYPE BAG-5 (45% AG), CADMIUM-FREE SILVER ALLOY FOR JOINING COPPER WITH BRONZE OR <br />STEEL. USE MANUFACTURERS RECOMMENDED FLUX. <br />B. FIELD SWAGED BRAZING CUPS: FABRICATE BRAZING CUP ON ONE TUBING END FOR EACH COUPLING. <br />ONLY O60 (SOFT ANNEALED) AND H55 (LIGHT DRAWN) MAY BE SWAGED. DO NOT SWAGE H58 (DRAWN <br />GENERAL PURPOSE). USE SWAGING TOOL DESIGNED TO PROVIDE A MINIMUM OF 0.0015" BRAZING GAP AND <br />A MAXIMUM OF 0.005" BRAZING GAP. BRAZING CUP DEPTH FOR EACH TUBE SIZE SHALL BE AS FOLLOWS. <br />C. FIELD BENDS: FABRICATE FIELD BENDS WITH A CENTER-LINE BEND RADIUS GREATER THAN OR <br />EQUAL TO 4 TIMES THE NOMINAL OD OF THE PIPE OR TUBE. TUBE SHALL BE BENT WITH A TUBING BENDER <br />SIZED FOR ACR OD TUBE SIZES AND SHALL NOT CAUSE CRACKS OR WRINKLES IN THE TUBE OR PIPE. DO <br />NOT USE A CONDUIT BENDER FOR BENDING <br />ACR COPPER. THE DIFFERENCE BETWEEN MAXIMUM AND MINIMUM DIAMETERS FOR PIPE BENDS SHOULD <br />NOT EXCEED 8% OF THE NOMINAL OUTSIDE DIAMETER OF THE PIPE. ONLY O60 SOFT ANNEALED-TEMPER <br />AND H55 LIGHT DRAWN-TEMPER SHALL BE FIELD BENT. DO NOT FIELD BEND H58 DRAWN GENERAL <br />PURPOSE-TEMPER COPPER TUBE. <br />D. BRAZING AND JOINING PROCEDURE <br />1. TUBE ENDS SHALL BE CUT WITH A CLEAN SHARP TUBING CUTTER. <br />2. DEBURR THE I.D. OF THE CUT TUBE END WITH A CLEAN DEBURRING TOOL. <br />3. VISUALLY INSPECT THE INTERIOR OF EACH TUBE FOR OBSTRUCTIONS AND DEBRIS BEFORE <br />ASSEMBLY. PROTECT THE JOINT FROM CONTAMINATION BEFORE BRAZING. <br />4. METHOD OF PRE-CLEANING: NON-SHEDDING ABRASIVE PADS (SCOTCH BRIGHT) TO REMOVE ALL <br />OXIDES IN THE BRAZING AREA FOLLOWED BY WIPING WITH A CLEAN LINT-FREE WHITE CLOTH. DO NOT <br />GROOVE THE SURFACES WHILE CLEANING. <br />5. PURGE ALL TUBING WITH OIL FREE NITROGEN WHILE BRAZING AND UNTIL COOL TO THE TOUCH. USE <br />AN OXYGEN ANALYZER TO VERIFY THE ABSENCE OF OXYGEN PRIOR TO BRAZING. THE OXYGEN CONTENT <br />SHALL BE LESS THAN 1% BEFORE START OF BRAZING. <br />6. USE A NEUTRAL TO SLIGHTLY REDUCING FLAME USING OXY/ACETYLENE OR OXY/PROPANE. <br />7. USE THE PROPER TORCH TIP BASED ON TUBE SIZE AS RECOMMENDED BY THE TORCH <br />MANUFACTURER. USE OF TURBO-TORCH OR ROSEBUD IS PERMITTED. <br />8. POST BRAZING CLEANING: EXTERIOR OF ALL COMPLETED JOINTS SHALL BE WASHED WITH A WATER <br />SOAKED RAG OR SPONGE, FOLLOWED BY BRUSHING WITH A STAINLESS-STEEL HAND WIRE BRUSH TO <br />REMOVE ANY RESIDUE FOR INSPECTION. <br />3.5 HANGERS AND SUPPORTS <br />A. HANGER, SUPPORT, AND ANCHOR PRODUCTS ARE SPECIFIED IN DIVISION 23 SECTION "HANGERS AND <br />SUPPORTS FOR HVAC PIPING AND EQUIPMENT." <br />B. INSTALL THE FOLLOWING PIPE ATTACHMENTS: <br />1. ADJUSTABLE STEEL CLEVIS HANGERS FOR INDIVIDUAL HORIZONTAL RUNS. <br />2. RIGID HIGH COMPRESSIVE STRENGTH FOAM INSULATING PIPE SUPPORT AT ALL SUPPORT POINTS. <br />COMPLY WITH SECTION 230719 "DX PIPING SYSTEM INSULATION". <br />3. DO NOT ATTACH HANGERS DIRECTLY TO PIPE OR TUBE. <br />C. INSTALL HANGERS FOR COPPER TUBING WITH THE FOLLOWING MAXIMUM SPACING AND MINIMUM <br />ROD SIZES: <br />1. UP TO 3/4" OD: MAXIMUM SPAN, 60 INCHES; MINIMUM ROD SIZE, 3/8 INCH. <br />2. GREATER THAN 3/4" THRU 1" OD: MAXIMUM SPAN, 72 INCHES; MINIMUM ROD SIZE, 3/8 INCH <br />3. GREATER THAN 1" THRU 2-1/8" OD: MAXIMUM SPAN, 96 INCHES; MINIMUM ROD SIZE, 3/8 INCH. <br />D. SUPPORT MULTI-FLOOR VERTICAL RUNS EVERY 10 FEET AND AT LEAST AT EACH FLOOR. <br />3.6 FIELD QUALITY CONTROL <br />A. PERFORM TESTS AND INSPECTIONS AND PREPARE TEST REPORTS. <br />B. TESTS AND INSPECTIONS: <br />1. COMPLY WITH ASME B31.5, CHAPTER VI. <br />2. TEST AS RECOMMENDED BY EQUIPMENT MANUFACTURERS INSTRUCTIONS. <br />3. TEST REFRIGERANT PIPING AND SPECIALTIES. ISOLATE COMPRESSOR, CONDENSER, EVAPORATOR, <br />AND SAFETY DEVICES FROM TEST PRESSURE IF THEY ARE NOT RATED ABOVE THE TEST PRESSURE. <br />a. FILL SYSTEM WITH 95/5 NITROGEN/HYDROGEN TO THE REQUIRED TEST PRESSURE. <br />b. SYSTEM SHALL MAINTAIN TEST PRESSURE AT THE MANIFOLD GAGE THROUGHOUT DURATION OF <br />TEST. <br />c. TEST ALL JOINTS AND FITTINGS WITH HYDROGEN LEAK DETECTOR, AT TEST PRESSURE. <br />d. REMAKE LEAKING JOINTS USING NEW MATERIALS, AND RETEST UNTIL SATISFACTORY RESULTS ARE <br />ACHIEVED. <br />3.7 SYSTEM CHARGING <br />A. CHARGE SYSTEM USING THE FOLLOWING PROCEDURES AND PER EQUIPMENT MANUFACTURERS <br />INSTRUCTIONS. <br />1. EVACUATE (TRIPLE EVACUATION PROCEDURE) ENTIRE REFRIGERANT SYSTEM WITH A VACUUM PUMP <br />TO OBTAIN A STEADY STATE VACUUM OF LESS THAN 500 MICROMETERS. IF VACUUM HOLDS FOR 12 HOURS, <br />SYSTEM IS READY FOR CHARGING. DO NOT EVACUATE THE SYSTEM THROUGH A CHARGING MANIFOLD. <br />USE ONLY SUCTION RATED HOSES AND CORE REMOVAL TOOLS. <br />2. BREAK VACUUM WITH REFRIGERANT GAS, ALLOWING PRESSURE TO BUILD UP TO 2 PSIG. <br />3. CHARGE SYSTEM AS RECOMMENDED BY EQUIPMENT MANUFACTURER.