My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CITY PROJECT - 1821 & 1823 E Chestnut Ave - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Chestnut Ave
>
1821 E Chestnut Ave
>
CITY PROJECT - 1821 & 1823 E Chestnut Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 11:14:23 AM
Creation date
2/24/2026 11:13:50 AM
Metadata
Fields
Template:
Plan
Permit Number
20184680
20184681
30148144
30148145
40139793
40139794
101121878
101121879
Full Address
1821 E Chestnut Ave
1823 E Chestnut Ave
Street Number
1823
Street Direction
E
Street Name
Chestnut
Street Suffix
Ave
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
333
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br /> <br />ASSOCIATED SOILS ENGINEERING, INC. Project No.: 7160.23 <br />2860 Walnut Avenue, Signal Hill CA 90755 January 23, 2024 <br />Tel: (562) 426 -7990 * Fax: (562) 426 -1842 Page 18 <br /> b) Allowable Soils Bearing Capacity: <br />For footings complying with the minimum dimension requirements stipulated in Section 5.3.2a) <br />above, the allowable soils bearing capacities, inclusive of both dead and live loads, should be as <br />per tabulated below: <br />Allowable Soils Bearing Capacity (psf) Increase per 12- <br />inch Increment in <br />Footing Width <br />(psf) <br />Increase per 12- <br />inch Increment in <br />Footing Depth <br />(psf) <br />Maximum <br />Composite <br />Ceiling Value <br />(psf) <br />Continuous <br />Spread Footing/ <br />Strip Footing <br />Isolated Pad <br />Footing <br />2,000 2,000 100 300 3,000 <br /> <br />The allowable bearing capacities tabulated above may be increased by one-third (1/3) when <br />subject to short-term, transient loading induced by wind or seismic activities. <br /> <br />For any new footings that are within a lateral distance from any existing building footing equal <br />to the depth of the new footing (D), the following tabulated reduction factors should be applied <br />to the corresponding allowable soils bearing capacity values. <br />Lateral Distance between New Footing and Existing <br />Building Footing expressed in Fraction of the New <br />Footing Depth, D <br /> 1D ½D <br /> <br />0 <br />Reduction Factor To Allowable Soils Bearing Capacity a 1.0 0.75 0.5 <br />a. Interpolation may be used for deriving reduction factor for other distance value. <br /> <br />c) Lateral Resistance: <br />Resistance to lateral loads can be assumed to be provided by passive lateral earth pressure and <br />by friction acting on structural components in permanent contact with the subgrade soils. <br /> <br />For site preparation implemented as per recommended in the above Section 5.2, lateral <br />resistance on the sides of foundations may be computed using a passive lateral earth pressure <br />of 200 pcf EFP for footings embedded into approved compacted fill soils, subject to a maximum <br />of 2,000 psf. An ultimate coefficient of friction on the order of 0.35 may also be used for <br />structural dead load acting between the footing bottom and the supporting soils, regardless of <br />the lateral distance between new footing and existing building footing. <br /> <br />The above passive lateral earth pressure may be used in conjunction with the ultimate <br />coefficient of friction in calculating composite lateral resistance, provided the passive lateral <br />earth pressure value is reduced by one-third (1/3). The composite lateral resistance may be <br />increased by one-third (1/3) under short term, transient wind or seismic loading. <br />
The URL can be used to link to this page
Your browser does not support the video tag.