My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CITY PROJECT - 1821 & 1823 E Chestnut Ave - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Chestnut Ave
>
1821 E Chestnut Ave
>
CITY PROJECT - 1821 & 1823 E Chestnut Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 11:14:23 AM
Creation date
2/24/2026 11:13:50 AM
Metadata
Fields
Template:
Plan
Permit Number
20184680
20184681
30148144
30148145
40139793
40139794
101121878
101121879
Full Address
1821 E Chestnut Ave
1823 E Chestnut Ave
Street Number
1823
Street Direction
E
Street Name
Chestnut
Street Suffix
Ave
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
333
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
KPFF Consulting Engineers Project : <br />700 South Flower Street, Suite 2100 Job no. : <br />Los Angeles, CA 90017 Date : <br />(213) 418-0201 S4-1 (WEST)By : <br />SAZ <br />D. DETAILED DESIGN INFORMATION <br />D.1 SHEAR WALL DESIGN DETAILS (AWC SDPWS 2015, Section 4.3) <br />SEISMIC WIND <br />Wall Unit Shear:280 lb/ft 0 lb/ft <br />=N/A <br />Aspect Ratio Factor <br />Wood Structural Panel =1 <br />Structural Fiberboard =N/A <br />Wall Capacities SEISMIC WIND <br />Wall Nominal Unit Shear Capacity =680 lb/ft 950 lb/ft <br />Wall Design Unit Shear Capacity =340 lb/ft 475 lb/ft <br />Wall DCR =0.82 OK 0.00 OK <br />D.2 WALL POST AND HOLDDOWN DESIGN DETAIL <br />POST DESIGN <br />Design Post Compression = <br />5323 lb <br />B.E. Species: <br />Post Size: <br />2 in Fc = <br />9 in Emin = <br />1.00 c = 1.00 <br />Post Grade: <br />Strong Direction Un-braced Length: <br />Weak Direction Un-braced Length: <br />Adjustment Factors:CD 1.6 <br />CM 1.0 <br />Ct 1.0 <br />CF 1.1 <br />Ci 1.0 <br />Cp 0.2 <br />Buckling Length Coefficients: <br />Strong-Direction, Ke1 =1.0 <br />Weak-Direction, Ke2 =1.0 <br />Post Capacity =9793 lb <br />Post Compression DCR =0.54 OK <br />HOLD DOWN DESIGN <br />Design Holdown Tension = <br />2198 lb <br />Hold Down Type:SIMPSON- <br />Holdown Capacity =3075 lb <br />Holdown DCR =0.71 OK <br /> <br />2198 lb/ft <br />HDU2-SDS2.5 <br />Douglas Fir-Larch <br />DESIGN VALUE FOR LOAD COMBO OF INTEREST : 5) <br />0.6D+0.7E <br />280 lb/ft <br />Actual Depth = <br />4x6 <br />Actual Width = <br />DESIGN VALUE FOR LOAD COMBO OF INTEREST : 5) <br />0.6D+0.7E <br />4962 lb/ft <br />620000 psi <br />1350 psi <br />Select Structural <br />15 ft <br />0 ft <br />DESIGN VALUE FOR LOAD COMBO OF INTEREST : 5) <br />0.6D+0.7E <br />Unblocked Shear Wall Adjustment <br />YES <br />16 <br />Wood Structural Panels - Structural 1 <br />Stud Spacing: <br />Blocking Provided When Required? <br />Panel Edge Fastener Spacing (in.): <br />Sheathing Material: <br />Minimum Nominal Panel Thickness (in.): <br />6 <br />15/32 <br />10dFastener Size: <br />Fc Size Factor, CF =
The URL can be used to link to this page
Your browser does not support the video tag.